Thank you for choosing a De’Longhi product. Please take a
few minutes to read these instructions. This will avoid all
risks and damage to the appliance.
Symbols used in these instructions
Important warnings are identied by these symbols.
It is vital to respect these warnings. Failure to observe the instructions could result in electric shock, serious injury, burns,
re or damage to the appliance.
Danger!
Failure to observe the warning may result in life threatening
injury by electric shock.
Important!
Failure to observe the warning could result in injury or damage to the appliance.
Please note:
This symbol identies impor tant advice or information for
the user.
Troubleshooting and repairs
If the appliance requires repair, always contact the manufacturer’s Customer Services.
Always insist on original spare parts.
Repairs carried out by unauthorised personnel may be dangerous and invalidate the guarantee.
Designated use
This is a household appliance only. Use only as described in
these instructions.
IMPORTANT SAFEGUARDS
Fundamental safety warnings
Use this local air conditioner only as described in this instruction manual. As with all electrical equipment, whilst the
instructions aim to cover as many eventualities as possible,
caution and common sense should be applied when operating
and installing this appliance.
This appliance is designed for home air conditioning and must
not be used for other purposes.
Danger! This is an electrical appliance, it is therefore
important to respect the following safety warnings:
• It is dangerous to modify or alter the characteristics of the
appliance in any way.
• The appliance must be installed in conformity with national legislation regulating electrical equipment and
installations.
• If the appliance requires repair, contact a Service Centre
authorised by the manufacturer only. Repairs carried out
by unauthorised personnel may be dangerous.
• The appliance must be connected to an ecient earth
system. Have your electrical circuit checked by a qualied
electrician.
• Do not use extension cables.
• Before cleaning or maintenance, always unplug the ap-
pliance from the mains socket.
• Never unplug the appliance by pulling on the power cable.
• Do not install the appliance in rooms containing gas, oil
or sulphur. Do not install near sources of heat.
• Keep the appliance at least 50 cm away from ammable
substances (alcohol etc) or pressurised containers (eg.
aerosol cans).
• Do not rest heavy or hot objects on top of the appliance.
• Avoid using heating appliances near the air conditioner.
• If the power cable is damaged, it must be replaced by the
manufacturer or an authorised technical service centre in
order to avoid all risk.
Important!
by adults.
Important!
by people (including children) with psychological, physical
or sensory impairments or with insucient experience and
This appliance must be used exclusively
Never allow the appliance to be used
13
14
en
Guarantee/Technical specication
knowledge, unless closely supervised and instructed by someone responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance.
Please note:
Please note:
resting on one side. Before moving the appliance, empty
the internal circuit completely of water. After moving the
appliance, wait at least 1 hour before starting it.
Clean the air lter at least once a week.
Always transport the appliance upright or
TECHNICAL SPECIFICATION
Power supply voltage see rating plate
Max. absorbed power
during air conditioning “
Refrigerant “
Cooling capacity “
Limit conditions:
Room temperature for air conditioning 21 ÷ 35°C
Please note:
cover with plastic bags.
Please note:
recycled. You are therefore recommended to dispose of
them in special dierentiated waste collection containers.
Please note:
appliance to a specialist collection centre.
When putting the appliance away, do not
The materials used for packaging can be
At the end of its working life, consign the
Specic warnings for appliances with
R410A refrigerant gas
R410A refrigerant gas conforms to EC regulations on the environment. Avoid perforating the refrigerant circuit of the appliance.
ENVIRONMENTAL INFORMATION: This unit contains uorinated greenhouse gases covered by the Kyoto Protocol. Main-
tenance and disposal must be carried out by qualied person-
nel only (R410A, GWP=1975).
Please note:
your appliance on the rating plate.
Verify the type of refrigerant gas used in
DISPOSING OF THE APPLIANCE
In compliance with European directive 2002/96/EC,
the appliance must not be disposed of with household waste, but taken to an authorised waste separation and recycling centre.
Please note: Transport, lling, cleaning, recovery and disposal of refrigerant should be performed
by a technical service centre appointed by the manufacturer only. The appliance should be disposed of by
a specialist centre appointed by the manufacturer
only.
GUARANTEE AND TECHNICAL
ASSISTANCE
The conditions of the guarantee and technical assistance are
given on the certicate supplied with your appliance.
15
en
DESCRIPTION
2
1
1 air outlet grille
2 control panel
3 handles
4 castors
5 lter
6 evaporator air intake grille
7 air exhaust hose housing
8 condenser air intake grille
9 power cable
10 drain hose with 2 caps
11 ange with cap
12 air exhaust hose
13 hose adapter (2 pieces)
14 wall mounting accessory
15 window outlet
16 remote control unit (some models only)
USE
Electrical connections
Before plugging the appliance into the mains socket, check
that:
• The mains power supply corresponds to the value
indicated on the rating plate on the back of the
appliance;
• The mains socket and electrical circuit are adequate for
the appliance;
• The mains socket matches the plug. If this is not the
case, have the plug replaced;
• The mains socket is adequately earthed. Failure to
follow these important safety instruc tions absolves the
manufacturer of all liability.
Description/Use
• Fit the other adapter 13 to the air exhaust hose housing
7 at the back of the appliance (see g. A).
• Screw the end of the hose without adapter to the
adapter previously mounted on the appliance (see g.
A).
A
• Fit the window outlet 15 to the airexhaust hose 12 as
shown in g. B.
B
• Place the air conditioner near a window or French
window.
• Make sure the air exhaust hose is unobstructed.
• Open the window or French window slightly and
position the outlet 15 as shown in gure C.
Danger! The power cable must be replaced by a
qualied professional only.
Important! Before use, make sure the air intake
and outlet grilles are unobstructed.
The instructions below will enable you to prepare your air
conditioner for operation as eciently as possible.
Air-conditioning without installation
Just a few simple steps and your comfort isensured with your
air conditioner:
• Screw one of the hose adapters 13 to oneend of the air
exhaust hose 12.
C
Important! Keep the air hoses as short and free of
curves as possible to avoid constrictions.