DeLonghi EAM 3000 OPERATING INSTRUCTIONS testprocedure

TEST PROCEDURE FOR
EAM 3000 SERIES
The following procedure enables the operator to test, one by one, the functional parts of the machine.
Proceed as follows:
- machine off and plug detached from the socket,
- to enter the test mode: press simultaneously, “1 cup” and “Steam” buttons and insert the plug on socket,
- Release the buttons and the machine is on the “Test function”
- the “test” procedure will be disabled automatically after 2 minutes.
The operator can check the following function:
- Pressing “1cup”, the movement motor will go “up”till the “up-end switch” then 1 cup led on,
- Pressing “2cup”, the movement motor will go “down” till the “down-end switch” then 2 cups led on,
- While the movement motor is on, the “grounded coffee” led is flashing: means the Hall sensor is working,
- Pressing “grounded coffee” the grinder motor goes on,
- Pressing “steam” button, the pump goes on,
- While the pump is on the “steam” led is on: means the flowmeter is working,
- Pressing “cleaning and descaling” button, the thermoblock goes on (1 and 2 cups led
on),
- Opening the “service door” the “generic alarm” goes on,
- Removing the “coffee grounds” container, the the relative led goes on,
- Opening the steam valve the “cleaning and descaling led will go on,
- Removing the water tank, the relative led goes on,
- While thermoblock is “on”, “1 and 2 cups led are “on”,
- Pressing the “on/off” button and turning the “quantity of coffee” knob, the following:
- far left position: “1cup” led on,
- Central position: “2cups led on,
- Far right position: “steam”led on.
- pressing the “on/off” button and turning the “quantity of water” knob , the following:
- far left position: “no water” led on,
- Central position: “coffee ground tray” led on,
- Far right position: “generic alarm”led on.
To exit the test mode, unplug the machine (the “test” procedure will be disabled anyway automatically after 2 minutes).