TEST PROCEDURE FOR
EAM 3000 SERIES
The following procedure enables the operator to test, one by one, the functional parts of the
machine.
Proceed as follows:
- machine off and plug detached from the socket,
- to enter the test mode: press simultaneously, “1 cup” and “Steam” buttons and insert the plug on
socket,
- the leds “1cup” , “2cups” and “Steam” will light for 2 seconds, then the machine is on “TEST”.
- Release the buttons and the machine is on the “Test function”
- the “test” procedure will be disabled automatically after 2 minutes.
The operator can check the following function:
- Pressing “1cup”, the movement motor will go “up”till the “up-end switch” then 1 cup led
on,
- Pressing “2cup”, the movement motor will go “down” till the “down-end switch” then 2
cups led on,
- While the movement motor is on, the “grounded coffee” led is flashing: means the Hall
sensor is working,
- Pressing “grounded coffee” the grinder motor goes on,
- Pressing “steam” button, the pump goes on,
- While the pump is on the “steam” led is on: means the flowmeter is working,
- Pressing “cleaning and descaling” button, the thermoblock goes on (1 and 2 cups led
on),
- Opening the “service door” the “generic alarm” goes on,
- Removing the “coffee grounds” container, the the relative led goes on,
- Opening the steam valve the “cleaning and descaling led will go on,
- Removing the water tank, the relative led goes on,
- While thermoblock is “on”, “1 and 2 cups led are “on”,
- Pressing the “on/off” button and turning the “quantity of coffee” knob, the following:
- far left position: “1cup” led on,
- Central position: “2cups led on,
- Far right position: “steam”led on.
- pressing the “on/off” button and turning the “quantity of water” knob , the following:
- far left position: “no water” led on,
- Central position: “coffee ground tray” led on,
- Far right position: “generic alarm”led on.
To exit the test mode, unplug the machine (the “test” procedure will be disabled anyway
automatically after 2 minutes).