Dell S5048F-ON, S4248FB-ON, S4248FBL-ON Setup Manual

S5048F-ON
Set-up Guide
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of
your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data
WARNING: A WARNING indicates a potential for property damage, personal injury,
or death.
Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are
trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
2017 - 10
Rev. A00
Contents
1 About this guide...............................................................................5
Related documents................................................................................... 6
Information symbols..................................................................................6
2 Site preparations............................................................................. 7
Site selection..............................................................................................7
Cabinet placement.................................................................................... 8
Rack mounting...........................................................................................8
Switch ground............................................................................................8
Fans and airow........................................................................................ 9
Power..........................................................................................................9
Storing components................................................................................10
3 S5048F-ON switch installation.......................................................11
Unpack.......................................................................................................11
Rack or cabinet installation.....................................................................12
Rack mount safety considerations...................................................12
ReadyRails installation............................................................................. 13
1U tool-less mount installation..........................................................14
Two-post ush-mount installation................................................... 15
Two-post center-mount installation.................................................17
Four-post threaded installation........................................................ 18
S5048F-ON switch installation..............................................................19
1U front-rack installation.................................................................. 20
Optics installation....................................................................................23
Optics removal...................................................................................23
Switch power-up..................................................................................... 23
Power up sequence.......................................................................... 24
After switch installation.......................................................................... 24
Contents
3
4 Specications............................................................................... 25
Chassis physical design.......................................................................... 25
5 Support.........................................................................................28
4 Contents
About this guide
This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting modules, and connecting to a power source.
CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist
straps when handling this equipment.
WARNING: Only trained and qualied personnel can install this equipment. Read this
guide before you install and power up this equipment. This equipment contains two power cords. Disconnect both power cords before servicing.
WARNING: This equipment contains optical transceivers, which comply with the
limits of Class 1 laser radiation.
Figure 1. Class 1 laser product tag
WARNING: When no cable is connected, visible and invisible laser radiation may be
emitted from the aperture of the optical transceiver ports. Avoid exposure to laser radiation, and do not stare into open apertures.
Topics:
Related documents
Information symbols
1
About this guide 5
Related documents
For more information about the S5048F-ON switch, see the following documents.
Dell Command Line Reference Guide for the S5048F-ON System
Dell Conguration Guide for the S5048F-ON System
Installation Guide for the S5048F-ON Switch
Open Networking Hardware Diagnostic Guide
Dell EMC S5048F-ON Release Notes
NOTE: For the most recent documentation, visit the support site: www.dell.com/
support.
Information symbols
This book uses the following information symbols:
NOTE: The Note icon signals important operational information.
CAUTION: The Caution icon signals information about situations that could result in
equipment damage or loss of data.
WARNING: The Warning icon signals information about hardware handling that
could result in injury.
WARNING: The ESD Warning icon requires that you take electrostatic precautions
when handling the device.
6 About this guide
Site preparations
The S5048F-ON switch is suitable for installation as part of a common bond network (CBN).
You can install the switch in:
Network telecommunication facilities
Data centers
Other locations where the National Electric Code (NEC) applies
For more information about the S5048F-ON switch specications, see Specications.
NOTE: Install the switch into a rack or cabinet before installing any optional
components.
Topics:
Site selection
Cabinet placement
Rack mounting
Switch ground
Fans and airow
Power
Storing components
Site selection
Install your equipment in restricted access areas. A restricted access area is one where service personnel can only gain access using a special tool, lock, key, or other means of security. The authority responsible for the location controls access to the restricted area.
2
Site preparations 7
Ensure that the area where you install your switch meets the following safety requirements:
Near an adequate power source. Connect the switch to the appropriate branch circuit protection according to your local electrical codes.
Environmental—switch location—continuous temperature range is from 0°C to 45°C (32°F to 113°F).
Operating humidity is from 5 to 85 percent noncondensing, continuous.
In a dry, clean, well-ventilated, and temperature-controlled room, away from heat sources such as hot cooling vents or direct sunlight.
Away from sources of severe electromagnetic noise.
Positioned in a rack or cabinet, or on a desktop with adequate space in the front, back, and sides for proper ventilation and access.
Install the switch in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75.
For more information about switch storage and environmental temperatures, see
Specications.
Cabinet placement
Install the S5048F-ON switch only in indoor cabinets designed for use in a controlled environment.
Do not install the switch in outside cabinets. For cabinet placement requirements, see Site
selection.
The cabinet must meet minimum size requirements. Airow must be in accordance with the Electronic Industries Alliance (EIA) standard. Ensure that there is a minimum of 5 inches (12.7 cm) between the intake and exhaust vents and the cabinet wall.
Rack mounting
When you prepare your equipment rack, ensure that the rack is grounded. Ground the equipment rack to the same ground point the power service in your area uses. The ground path must be permanent.
Switch ground
Dell EMC recommends grounding your switch. Use the S5048F-ON switch in a CBN.
8
Site preparations
Fans and airow
Fan installation is done as part of the factory install based on stock keeping unit (SKU) type. The S5048F-ON switch has SKUs that support the following congurations:
AC fan unit with fan airow from the I/O to the PSU—normal
AC fan unit with fan airow from the PSU to the I/O—reverse
DC fan unit with airow from the I/O to the PSU—normal
DC fan unit with fan airow from the PSU to the I/O—reverse
Be sure to order the fans suitable to support your site’s ventilation. Use a single type of airow fan in your switch. Do not mix reverse and normal airows in a single switch.
For proper ventilation, position the switch in an equipment rack or cabinet with a minimum of 5 inches (12.7 cm) of clearance around the exhaust vents. The fan speed varies based on internal temperature monitoring. The switch never intentionally turns o the fans.
Power
To connect the switch to the applicable power source, use the appropriate power cable. An AC power cable is included with the switch.
When installing AC or DC switches, follow the requirements of the National Electrical Code ANSI/NFPA 70, where applicable.
The switch is powered-up when the power cable is connected between the switch and the power source.
CAUTION
: Always disconnect the power cable before you service the power supply
slots. The switch has multiple power cords. Before servicing, ensure that all power cords are disconnected.
CAUTION: On the AC switch, use the power supply cable as the main disconnect
device. Ensure that the socket-outlet is located/installed near the equipment and is easily accessible.
NOTE: Module power is software controlled. You do not see module LEDs when the
switch powers up in ONIE.
Site preparations 9