Dell PowerEdge C6320p User Manual [zh]

Dell PowerEdge C6320p
用户手册
管制型号 B08S Series 管制类型 B08S004
October 2020 Rev. A03
注意、小心和警告
注: “注意”表示帮助您更好地使用该产品的重要信息。
警告: “警告”表示可能会导致财产损失、人身伤害甚至死亡。
© 2017 - 2018 Dell Inc. 或其子公司。保留所有权利。DellEMC 和其他商标是 Dell Inc. 或其附属机构的商标。其他商标可能是其各自所有者的商标。
目录
1: Dell PowerEdge C6320p 概览.................................................................................................... 8
PowerEdge C6300 机柜和 C6320p 底座支持的配置..................................................................................................... 8
前面板.................................................................................................................................................................................... 11
PowerEdge C6320p 底座的 PowerEdge 6300 机柜的前面板功能...................................................................11
背面板................................................................................................................................................................................... 13
PowerEdge C6320p 底座的 PowerEdge 6300 机柜的背面板功能..................................................................13
诊断指示灯........................................................................................................................................................................... 15
硬盘驱动器指示灯显示方式........................................................................................................................................ 15
网络端口指示灯代码.....................................................................................................................................................16
电源设备单元指示灯代码............................................................................................................................................ 17
电源和系统板指示灯代码............................................................................................................................................ 19
iDRAC 心跳 LED 指示灯.............................................................................................................................................. 20
Intel Xeon Phi 72XX Phi 72XXF 处理器的配置限制................................................................................................. 20
底座硬盘连接布局...............................................................................................................................................................21
找到您的系统服务标签...................................................................................................................................................... 21
2: 说明文件资源......................................................................................................................... 23
3: 技术规格............................................................................................................................... 25
机箱尺寸.............................................................................................................................................................................. 25
机箱重量.............................................................................................................................................................................. 26
处理器规格.......................................................................................................................................................................... 26
PSU 规格..............................................................................................................................................................................26
系统电池规格 ..................................................................................................................................................................... 27
内存规格 ..............................................................................................................................................................................27
硬盘驱动器和存储规格......................................................................................................................................................27
内部 SD 卡插槽................................................................................................................................................................... 27
端口和连接器规格.............................................................................................................................................................. 27
USB 端口........................................................................................................................................................................ 27
NIC 端口......................................................................................................................................................................... 28
VGA 端口........................................................................................................................................................................28
视频规格...............................................................................................................................................................................28
环境规格...............................................................................................................................................................................28
4: 初始系统设置和配置................................................................................................................30
在启动过程中访问系统功能............................................................................................................................................. 30
设置系统.............................................................................................................................................................................. 30
iDRAC 配置.......................................................................................................................................................................... 30
用于设置 iDRAC IP 地址的选项..................................................................................................................................30
安装操作系统的选项.......................................................................................................................................................... 31
下载固件和驱动程序的方法........................................................................................................................................ 31
5: 预操作系统管理应用程序......................................................................................................... 33
目录
3
用于管理预操作系统应用程序的选项.............................................................................................................................33
系统设置...............................................................................................................................................................................33
查看系统设置程序........................................................................................................................................................ 33
系统设置程序详细信息................................................................................................................................................34
System BIOS系统 BIOS........................................................................................................................................34
iDRAC 设置公用程序....................................................................................................................................................56
Device Settings设备设置.....................................................................................................................................56
Dell Lifecycle Controller...................................................................................................................................................... 57
嵌入式系统管理............................................................................................................................................................ 57
引导管理器.......................................................................................................................................................................... 57
查看引导管理器............................................................................................................................................................ 57
引导管理器主菜单........................................................................................................................................................58
PXE 引导.............................................................................................................................................................................. 58
6: 更新风扇控制器板固件............................................................................................................ 59
风扇控制板固件..................................................................................................................................................................59
使用 Racadm 更新风扇控制板固件...........................................................................................................................59
检查 FCB 固件版本...................................................................................................................................................... 60
机箱类型粘性位..................................................................................................................................................................60
PowerEdge C6320p 底座设置机箱类型粘性位.................................................................................................. 61
检查 PowerEdge C6320p 底座的机箱类型粘性位.................................................................................................. 61
7: 安装和卸下部件的前提条件...................................................................................................... 62
安全说明.............................................................................................................................................................................. 62
拆装系统内部组件之前..................................................................................................................................................... 62
拆装系统内部组件之后..................................................................................................................................................... 63
建议工具.............................................................................................................................................................................. 63
8: 安装和卸下底座组件................................................................................................................64
系统内部.............................................................................................................................................................................. 64
PowerEdge C6320p 底座.................................................................................................................................................. 65
卸下底座 ....................................................................................................................................................................... 65
安装底座 ....................................................................................................................................................................... 66
导流罩...................................................................................................................................................................................67
卸下空气导流罩 ........................................................................................................................................................... 67
安装空气导流罩 ........................................................................................................................................................... 68
系统内存.............................................................................................................................................................................. 69
内存插槽功能 ............................................................................................................................................................... 69
支持的内存模块配置 ...................................................................................................................................................69
卸下内存模块 ............................................................................................................................................................... 70
安装内存模块................................................................................................................................................................. 71
1.8 英寸固态驱动器............................................................................................................................................................ 72
卸下 1.8 英寸固态驱动器............................................................................................................................................. 72
安装 1.8 英寸固态驱动器............................................................................................................................................. 74
卸下 1.8 英寸固态驱动器托盘.....................................................................................................................................75
安装 1.8 英寸固态驱动器托盘.....................................................................................................................................76
卸下和安装底座的 SATA 电缆..........................................................................................................................................77
从底座中卸下 SATA 电缆............................................................................................................................................ 78
从底座上卸下 SSD SATA 电缆................................................................................................................................... 79
4
目录
SSD SATA 电缆安装在底座中...............................................................................................................................80
SATA 电缆安装在底座中........................................................................................................................................ 81
处理器和散热器模块..........................................................................................................................................................82
从处理器中卸下光缆....................................................................................................................................................83
将光缆连接到处理器....................................................................................................................................................85
卸下处理器和散热器模块........................................................................................................................................... 86
安装处理器和散热器模块........................................................................................................................................... 88
从处理器散热器模块卸下结构处理器.......................................................................................................................89
将光纤处理器安装在处理器散热器模块内............................................................................................................... 91
从处理器散热器模块卸下非光纤处理器.................................................................................................................. 94
将非光纤处理器安装在处理器散热器模块内.......................................................................................................... 96
扩展卡部件和扩展卡 .........................................................................................................................................................98
PCIe 插槽优先级 ..........................................................................................................................................................98
卸下扩展卡提升板部件................................................................................................................................................99
安装扩展卡提升板部件.............................................................................................................................................. 100
卸下扩展卡....................................................................................................................................................................101
安装扩展卡...................................................................................................................................................................104
卸下提升卡................................................................................................................................................................... 107
安装提升卡...................................................................................................................................................................108
从光纤托盘卡上卸下电缆..........................................................................................................................................109
将电缆连接至光纤托盘卡...........................................................................................................................................110
夹层卡和夹层桥接卡......................................................................................................................................................... 112
卸下夹层卡....................................................................................................................................................................112
安装夹层卡....................................................................................................................................................................114
卸下夹层卡桥接板 ...................................................................................................................................................... 116
安装夹层卡桥接板........................................................................................................................................................117
卸下夹层卡填充挡片................................................................................................................................................... 118
安装一个夹层卡填充挡片..........................................................................................................................................120
系统电池 .............................................................................................................................................................................121
卸下系统电池 - 选项 A................................................................................................................................................121
安装系统电池 - 选项 A............................................................................................................................................... 122
卸下系统电池 - 选项 B............................................................................................................................................... 123
安装系统电池 - 选项 B............................................................................................................................................... 124
可信平台模块.....................................................................................................................................................................124
安装可信平台模块...................................................................................................................................................... 125
初始化可信平台模块.................................................................................................................................................. 126
系统板................................................................................................................................................................................. 126
卸下系统板 ..................................................................................................................................................................126
安装系统板 ..................................................................................................................................................................128
SAS 连接器保护器............................................................................................................................................................ 129
卸下 SAS 连接器保护装置.........................................................................................................................................129
安装 SAS 连接器保护装置.........................................................................................................................................130
9: 安装和卸下机箱部件.............................................................................................................. 132
2.5 英寸硬盘驱动器或固态驱动器.................................................................................................................................132
卸下硬盘驱动器托盘.................................................................................................................................................. 132
安装硬盘驱动器托盘.................................................................................................................................................. 133
从硬盘驱动器托盘中卸下硬盘驱动器..................................................................................................................... 134
将硬盘驱动器安装到硬盘驱动器托盘中.................................................................................................................135
目录
5
电源设备............................................................................................................................................................................. 136
卸下电源设备单元.......................................................................................................................................................137
安装电源设备单元.......................................................................................................................................................138
系统护盖............................................................................................................................................................................. 139
卸下系统护盖...............................................................................................................................................................139
安装系统护盖...............................................................................................................................................................140
冷却风扇..............................................................................................................................................................................141
卸下冷却风扇................................................................................................................................................................141
安装冷却风扇...............................................................................................................................................................142
卸下冷却风扇固定框架.............................................................................................................................................. 143
安装冷却风扇固定框架.............................................................................................................................................. 144
配电板................................................................................................................................................................................. 146
卸下配电板 ..................................................................................................................................................................146
安装配电板................................................................................................................................................................... 149
配电板的电缆布线和连接器 .....................................................................................................................................153
中间板................................................................................................................................................................................. 155
卸下中间板...................................................................................................................................................................155
安装中间板...................................................................................................................................................................159
电缆布线 - 中间板至硬盘驱动器背板 .................................................................................................................... 160
硬盘驱动器背板.................................................................................................................................................................162
卸下硬盘驱动器背板.................................................................................................................................................. 162
安装硬盘驱动器背板.................................................................................................................................................. 164
控制面板............................................................................................................................................................................. 167
卸下控制面板............................................................................................................................................................... 167
安装控制面板...............................................................................................................................................................169
热传感器板.........................................................................................................................................................................170
卸下传感器板护盖.......................................................................................................................................................170
安装传感器板护盖........................................................................................................................................................171
卸下 的传感器板..........................................................................................................................................................172
安装 的传感器板..........................................................................................................................................................173
2.5 英寸硬盘驱动器系统的传感器板和控制面板的电缆布线............................................................................. 175
10: 使用系统诊断程序................................................................................................................ 176
Dell 嵌入式系统诊断程序.................................................................................................................................................176
何时使用 Embedded System Diagnostics嵌入式系统诊断程序.................................................................. 176
从引导管理器运行嵌入式系统诊断程序................................................................................................................. 176
Dell Lifecycle Controller 运行嵌入式系统诊断程序...........................................................................................176
系统诊断程序控制.......................................................................................................................................................177
11: 跳线和连接器 ...................................................................................................................... 178
PowerEdge C6320p 系统板连接器................................................................................................................................ 178
PowerEdge C6320p 系统板上的跳线设置....................................................................................................................179
12: 系统故障排除...................................................................................................................... 180
故障处理系统启动故障....................................................................................................................................................180
外部连接故障处理............................................................................................................................................................ 180
视频子系统故障排除.........................................................................................................................................................181
USB 设备故障处理.............................................................................................................................................................181
串行输入和输出设备故障处理........................................................................................................................................182
6
目录
NIC 故障处理..................................................................................................................................................................... 182
受潮系统故障处理............................................................................................................................................................ 183
受损系统故障处理............................................................................................................................................................ 183
系统电池故障处理............................................................................................................................................................ 184
电源装置故障处理............................................................................................................................................................ 185
电源问题故障处理...................................................................................................................................................... 185
电源设备故障...............................................................................................................................................................185
冷却问题故障处理............................................................................................................................................................ 186
冷却风扇故障处理............................................................................................................................................................ 186
系统内存故障处理.............................................................................................................................................................187
micro SD 卡故障处理........................................................................................................................................................ 187
驱动器或 SSD 故障处理...................................................................................................................................................188
扩展卡故障处理................................................................................................................................................................ 189
处理器故障处理................................................................................................................................................................ 189
系统消息.............................................................................................................................................................................190
警告消息....................................................................................................................................................................... 190
诊断消息....................................................................................................................................................................... 190
警报消息....................................................................................................................................................................... 190
13: 获取帮助............................................................................................................................. 191
联系 Dell EMC.....................................................................................................................................................................191
说明文件反馈..................................................................................................................................................................... 191
通过使用 QRL 访问系统信息...........................................................................................................................................191
PowerEdge C6320p 系统的快速资源定位器..........................................................................................................192
目录
7
1

Dell PowerEdge C6320p 概览

Dell PowerEdge C6300 是一种超密集 2U 机柜最多可支持四个独立单插槽 (1S) 底座连接到支持二十四个 2.5 英寸硬盘驱动器和两个 热插拔电源单元的直接背板。每个 PowerEdge C6320p 底座具有以下功能部件
每个底座配有 6468 72 Intel Xeon Phi 72XX 72XXF 处理器
每个处理器配有 16 GB MCDIMM
最多支持六个 DDR4 LRDIMM RDIMM 内存模块
每个底座支持六个 2.5 英寸硬盘驱动器或固态驱动器。
用于 I/O 连接的 Intel C612 芯片组
每个底座具有集成式 iDRAC 8 Express 系统管理技术和专用 RJ45 管理端口
每个底座具有一个嵌入式 1 千兆位以太网控制器 (RJ45)
可选的集成式 Mellanox ConnectX-4 VPI EDR/100 GbE 端口
警告: 不能将使用 Intel Xeon Phi 72XX 和 Phi 72XXF 处理器的底座安装在同一个机柜中。
注: 不支持在同一 PowerEdge C6300 机箱中混合使用 PowerEdge C6320 PowerEdge C6320p 底座。
主题
PowerEdge C6300 机柜和 C6320p 底座支持的配置
前面板
背面板
诊断指示灯
Intel Xeon Phi 72XX Phi 72XXF 处理器的配置限制
底座硬盘连接布局
找到您的系统服务标签

PowerEdge C6300 机柜和 C6320p 底座支持的配置

Dell PowerEdge C6300 机柜支持以下配置
8 Dell PowerEdge C6320p 概览
1: C6300 支持的配置
Dell PowerEdge C6320p 底座支持以下配置
Dell PowerEdge C6320p 概览 9
2: 具有 Intel Phi 72xx 处理器的 C6320p 底座支持的配置
10 Dell PowerEdge C6320p 概览
3: 具有 Intel Phi 72xx-F 处理器的 C6320p 底座支持的配置
前面板
通过前面板可以使用服务器正面提供的功能如电源按钮和系统识别按钮。可从前面板访问热插拔硬盘驱动器。

PowerEdge C6320p 底座的 PowerEdge 6300 机柜的前面板功能

4: 前面板功能部件和指示灯
底座 1 的系统识别指示灯 2. 底座 1 的电源按钮
1.
Dell PowerEdge C6320p 概览 11
3. 硬盘驱动器24 4.
5. 底座 3 的电源按钮 6. 底座 3 的系统识别指示灯
7. 底座 4 的电源按钮 8. 底座 4 的系统识别指示灯
9. 底座 2 的系统识别指示灯 10. 底座 2 的电源按钮
环境温度传感器护盖
. 1: 前面板功能部件和指示灯
项目 指示灯、按钮或连接器 图标 说明
1 底座 1 的系统标识指示灯或按
2 底座 1 的开机指示灯或系统状
态指示灯或电源按钮
3
4
5 底座 3 的开机指示灯或系统状
硬盘驱动器
环境温度传感器护盖 环境温度传感器位于该护盖后
态指示灯或电源按钮
按下系统 ID 按钮
找到机柜内的特定底座。
可开启或关闭系统 ID
: 如果底座在开机自检过
程中停止响应则按住底 座 ID 按钮五秒以上可进入 BIOS 进程模式。
按下电源按钮以打开或关闭底 座。按钮上的指示灯将指示底 座是打开还是关闭。
出现系统严重事件时通电指 示灯将呈琥珀色亮起。
注:
要正常关闭 ACPI 兼容操作系 统请按电源按钮。
最多 24 2.5 英寸热插拔硬盘 驱动器。机柜中的每个底座均 分配有六个硬盘驱动器。
面。
按下电源按钮以打开或关闭底 座。按钮上的指示灯将指示底 座是打开还是关闭。
出现系统严重事件时通电指 示灯将呈琥珀色亮起。
6 底座 3 的系统标识指示灯或按
7 底座 4 的开机指示灯或系统状
态指示灯或电源按钮
12 Dell PowerEdge C6320p 概览
注:
要正常关闭 ACPI 兼容操作系 统请按电源按钮。
按下系统 ID 按钮
找到机柜内的特定底座。
可开启或关闭系统 ID
: 如果底座在开机自检过
程中停止响应则按住系 统 ID 按钮五秒以上可进入 BIOS 进程模式。
按下电源按钮以打开或关闭底 座。按钮上的指示灯将指示底 座是打开还是关闭。
出现系统严重事件时通电指 示灯将呈琥珀色亮起。
注:
. 1: 前面板功能部件和指示灯
项目 指示灯、按钮或连接器 图标 说明
要正常关闭 ACPI 兼容操作系 统请按电源按钮。
8 底座 4 的系统标识指示灯或按
9 底座 2 的系统标识指示灯或按
10 底座 2 的开机指示灯或系统状
态指示灯或电源按钮
按下系统 ID 按钮
找到机柜内的特定底座。
可开启或关闭系统 ID
: 如果底座在开机自检过
程中停止响应则按住系 统 ID 按钮五秒以上可进入 BIOS 进程模式。
按下系统 ID 按钮
找到机柜内的特定底座。
可开启或关闭系统 ID
: 如果底座在开机自检过
程中停止响应则按住系 统 ID 按钮五秒以上可进入 BIOS 进程模式。
按下电源按钮以打开或关闭底 座。按钮上的指示灯将指示底 座是打开还是关闭。
出现系统严重事件时通电指 示灯将呈琥珀色亮起。
注:
要正常关闭 ACPI 兼容操作系 统请按电源按钮。
背面板
通过背面板可以访问服务背面提供的各种功能如系统识别按钮、电源插槽、iDRAC 连接端口、NIC 端口以及 USB VGA 端口。 大多数扩展卡端口都可以从背面板访问。

PowerEdge C6320p 底座的 PowerEdge 6300 机柜的背面板功能

5: 基于 Intel Phi 72xx 处理器的底座背面板功能部件和指示灯
电源设备(2 2.
1.
集成式四个小型可插拔端口
3.
5. iDRAC Enterprise 管理端口 6.
7. VGA 端口 8. 电源按钮/开机指示灯
无集成式四个小型可插拔端口的底座
9.
通用串行总线端口 以太网端口
4.
微型通用串行总线端口
Dell PowerEdge C6320p 概览 13
6: 基于 Intel Phi 72xx-F 处理器的底座背面板功能和指示灯
1. 电源设备2 2. 无集成式四个小型可插拔端口的底座
3.
5. iDRAC Enterprise 管理端口 6.
7. VGA 端口 8. 电源按钮/开机指示灯
无集成式四个小型可插拔端口的底座
9.
通用串行总线端口 以太网端口
4.
微型通用串行总线端口
具有四通道小型可插拔托盘卡的底座
10.
. 2: 背面板功能部件和指示灯
项目 指示灯、按钮或连接器 图标 说明
最多两个热插拔 1400 W 1600 W AC 电源设备 (PSU)
注: 无得混合使用不同瓦数
1
2 通用串行总线USB 端口 使用 USB 3.0 端口将 USB 设备
电源设备2
PSU
连接至系统。此端口是一个兼 容 USB 3.0 9 针端口。
3 四个小型可插拔QSFP
4
5 iDRAC Enterprise 管理端口 使用 iDRAC 8 Enterprise 管理端
6 微型通用串行总线USB
7 VGA 端口 使用视频/VGA 端口将显示屏连
8 电源按钮/开机指示灯
以太网端口
Mellanox ConnectX-4 VPI EDR / 100 GbE 嵌入式端口
单端口 1Gb LOM 以太网端口
口来远程访问 iDRAC 。有关详 细信息请参阅《Integrated
Dell Remote Access Controller
用户指南》网址:Dell.com/ idracmanuals
使用端口将系统连接至主机。
接到系统。有关支持的视 频/VGA 端口的更多信息请参 阅“技术规格”部分。
当系统接通电源时通电指示 灯将呈绿色亮起。
发生重大系统事件时开机指 示灯呈琥珀色点亮。
电源按钮控制对系统板的 PSU 输出。
: 开启系统时视频显示
器可能需要几秒到两分钟 不等的时间才能显示图
14 Dell PowerEdge C6320p 概览
. 2: 背面板功能部件和指示灯
项目 指示灯、按钮或连接器 图标 说明
这取决于系统可用的 磁盘空间。
: 对于兼容 ACPI 的操作
系统通过按电源按钮关 闭系统可以在系统关闭前 执行正常关机。
: 强制执行非正常关机
请按住电源按钮五秒钟。
9
10
无集成式四个小型可插拔端口 的底座
具有四通道小型可插拔托盘卡 的底座

诊断指示灯

系统上的诊断指示灯指示操作和错误状态。

硬盘驱动器指示灯显示方式

可选)Mellanox ConnectX-4 VPI EDR / 100 GbE
嵌入式端口的底座。
具有四通道小型可插拔托盘卡 和基于光纤的处理器的底座
7: 硬盘驱动器正面视图
1. 硬盘驱动器状态指示灯绿色和琥珀色
2. 硬盘驱动器活动指示灯绿色
. 3: 硬盘驱动器指示灯显示方式
控制器 硬盘驱动器类型 功能
板载控制器
SATA3
驱动器上线
故障
活动 LED 状态 LED
绿色 绿色
不亮/处于活动状态时闪 烁
Off(关
Dell PowerEdge C6320p 概览 15
打开
打开

网络端口指示灯代码

8: QSFP 托盘卡上的 LAN 指示灯
9: LAN 指示灯
1. 链路指示灯
2. 活动指示灯
. 4: QSFP 端口指示灯代码
连接状态
没有链接/未连接 Off Off
InfiniBand 物理链接 - 无逻辑链接
InfiniBand 逻辑链接没有通信
InfiniBand 逻辑链接 - 通信
InfiniBand 物理链接问题
以太网链接 – 没有通信
以太网 - 通信
: LED 闪烁速度视通信带宽而异。
QSFP 上部的绿色 LED 指示灯 QSFP 下部的绿色 LED 指示灯
绿色
绿色 绿色
绿色 闪烁
闪烁 绿色
绿色 绿色
绿色 闪烁
Off(关
16 Dell PowerEdge C6320p 概览
10: 以太网端口指示灯代码
1. 速率指示灯
2. 链路和活动指示灯
. 5: 以太网端口指示灯代码
惯例 状态 状态
A
B
C
D
链路和活动指示灯熄灭
链路指示灯呈绿色亮起
链接指示灯呈琥珀色亮起
活动指示灯呈绿色闪烁 正在发送或接收网络数据。
NIC 未连接至网络。
NIC 以低于其最高端口速度 (1 Gbps) 的速度连接到
有效的网络。
NIC 以低于其最高端口速度的速度连接到有效的网 络。

电源设备单元指示灯代码

每个交流电源设备单元 (PSU) 均具有发光的半透明手柄用于表明是否存在电源或是否出现电源故障。
1400 W AC HVDC 电源设备
11: 电源设备 (PSU) 状态指示灯
1. PSU
2. PSU 状态指示灯 LED
Dell PowerEdge C6320p 概览 17
. 6: 1400 W AC HVDC PSU 指示灯
电源指示灯显示方式 状态
绿色
绿色闪烁
呈绿色闪烁然后熄灭 在热添加 PSU PSU LED 4 Hz 频率闪烁绿光然后熄灭。
呈琥珀色闪烁
有效的电源已连接到 PSUPSU 正常运行。
正在更新 PSU 固件时PSU LED 呈绿色闪烁。
小心: 在更新固件时请勿断开电源线或拔下 PSU 插头。如
果固件更新中断PSU 将无法正常工作。您必须使用 Dell Lifecycle Controller 回滚 PSU 固件。有关更多信息请参 阅位于 Dell.com/idracmanuals 上的 Dell Lifecycle Controller Users GuideDell Lifecycle Controller 用户 指南
这表示 PSU 在效率、功能组、运行状况和支持的电压方面不匹 配。
注: 请确保这两个 PSU 的容量相同。
注: 混用前几代 Dell PowerEdge 服务器的 PSU 可能导致 PSU
不匹配或系统无法开机。
表示 PSU 出现问题。
小心: 在纠正 PSU 不匹配情况时请仅更换指示灯闪烁的
PSU。更换另外的 PSU 以构成匹配的 PSU 对将导致错误状
并且系统会出现意外关机。要从高输出配置更改为低输 出配置或反之必须关闭系统电源。
小心: 如果使用两个 PSU,二者必须为相同类型且具有相同
的最大输出功率。
不亮 未连接电源。
1600 W AC HVDC 电源设备
12: 电源设备 (PSU) 状态指示灯
1. PSU
2. 电源指示灯
. 7: 1600 W AC HVDC PSU 指示灯
惯例 电源指示灯显示方式 说明
绿色
A
B
绿色闪烁
有效的电源已连接到 PSUPSU 正常运 行。
PSU 的固件进行更新时PSU LED 指示灯 呈绿色闪烁。
小心: 在更新固件时请勿断开电源线
或拔下 PSU 插头。如果固件更新中
18 Dell PowerEdge C6320p 概览
. 7: 1600 W AC HVDC PSU 指示灯
惯例 电源指示灯显示方式 说明
PSU 将无法正常工作。您必须使 用 Dell Lifecycle Controller 回滚
PSU 固件。请参阅 Dell.com/ idracmanuals 上的
Controller Users Guide
Lifecycle Controller 用户指南
小心: 在更新固件时请勿断开电源线
或拔下 PSU 插头。如果固件更新中 断PSU 将无法正常工作。
注: 请确保这两个 PSU 的容量相同。
注: 混用前几代 Dell PowerEdge 服务器
PSU 可能导致 PSU 不匹配或系统无 法开机。
C 呈绿色闪烁然后熄灭 在热添加 PSU PSU LED 4 Hz 频率
闪烁绿光然后熄灭。这表示 PSU 在效 率、功能组、运行状况和支持的电压方面 不匹配。
D
呈琥珀色闪烁
表示 PSU 出现问题。
小心: 在纠正 PSU 不匹配情况时
仅更换指示灯闪烁的 PSU。更换另外 的 PSU 以构成匹配的 PSU 对将导致 错误状况并且系统会出现意外关 机。要从高输出配置更改为低输出配 置或反之必须关闭系统电源。
Dell Lifecycle
Dell
: AC PSU 同时支持 220 V 110 V
输入电压。在两个相同的 PSU 接收不 同的输入电压时它们可以输出不同 的功率并触发不匹配情况。
小心: 如果使用两个 PSU,二者必须
为相同类型且具有相同的最大输出功 率。
E
不亮 未连接电源。

电源和系统板指示灯代码

机柜前面板和背面板上的 LED 在系统启动和运行期间显示状态代码。有关前面板 LED 的位置请参阅“前面板功能部件和指示灯” 部分。有关背面板 LED 的位置请参阅“背面板功能部件和指示灯”部分。
. 8: 状态指示灯代码
组件 指示灯 状态
开机指示灯电源按钮上的双 色 LED
绿色 稳定
琥珀色
绿色
琥珀色 闪烁
Off
Off iDRAC 在关机模式下发生严重状况事件 (S4/S5)
开机 (S0)
绿色
琥珀色 亮起
Off(关 iDRAC 在开机模式下发生严重状况事件 (S0)
Dell PowerEdge C6320p 概览 19
. 8: 状态指示灯代码
组件 指示灯 状态
系统识别指示灯 呈蓝色稳定亮起
呈蓝色闪烁
Off(关 停用通过机箱识别命令操作的 IPMI,或停用通过按下识别按钮
启用通过机箱识别命令操作 IPMI或启用通过按下识别按钮进 行识别的功能
启用通过机箱识别命令仅操作 IPMI 时闪烁的功能
进行识别的功能

iDRAC 心跳 LED 指示灯

系统板提供 iDRAC 心跳 LED (CR17)以便进行 iDRAC 调试。iDRAC 心跳 LED 呈绿色。连接电源时LED 将亮起。当 iDRAC 固件准 备就绪时iDRAC 心跳 LED 便会开始闪烁。
13: iDRAC 心跳 LED 指示灯
1. iDRAC 心跳 LED 指示灯

Intel Xeon Phi 72XX Phi 72XXF 处理器的配置限制

警告: 不能将使用 Intel Xeon Phi 72XX 和 Phi 72XXF 处理器的底座安装在同一个机柜中。
小心: 某些系统硬件配置可能需要降低温度上限。
注: 在超过 35°C(95°F) 的温度条件下或带着风扇故障操作时系统性能可能会受到影响。
. 9: Intel Xeon Phi 72XX Phi 72XXF 处理器的配置限制
处理器功率 处理器型号 相应的限制
Phi 7210
215 W
230 Phi 7210F
Phi 7230
Phi 7250
Phi 7230F
Phi 7250F
10°C (50°F) 35°C (95°F)最大温度 变化梯度为每小时 10 摄氏度
245 Phi 7290
260 Phi 7290F
20 Dell PowerEdge C6320p 概览
环境温度限制为 23°C (73.4°F)

底座硬盘连接布局

二十四个 2.5 英寸热插拔硬盘到四个底座的连接如下所示
14: 底座硬盘连接布局
注: 硬盘的保修与相应底座的服务编号相关联。

找到您的系统服务标签

您的系统由唯一的快速服务代码和服务标签号码来标识。您可在系统正面找到快速服务代码和服务标签。另外该信息也可能位于 系统机箱上的不干胶标签上。Dell 使用此信息将支持电话转接到相应的人员。机箱上的服务标签位置如下所示
15: 服务标签位置
16: 左前面板上的服务标签位置
Dell PowerEdge C6320p 概览 21
17: 机箱上的服务标签位置
18: 服务标签链接
注: 保修期内的硬盘驱动器会链接至节点相应的服务标签。
22 Dell PowerEdge C6320p 概览
本节介绍了有关系统说明文件资源的信息。
要查看文档资源表中列出的说明文件表
从 Dell EMC 支持站点
1. 单击表中“位置”列下提供的文档链接。
2. 单击所需的产品或产品版本。
注: 要找到产品名称和型号请参阅您的系统正面。
3. 在“产品支持”页面上单击手册和文档
使用搜索引擎在搜索框中键入文档的名称和版本。
. 10: 系统其他说明文件资源
任务 说明文件 位置
2

说明文件资源

设置系统
配置系统
有关将系统安装到机架中的信息 请参阅系统随附的 Getting Started With Your System 文档包含的机架 说明文件。
有关 iDRAC 的功能、配置和登录 iDRAC,以及远程管理系统的信息 请参阅 Integrated Dell Remote Access Controller User's Guide
要了解 Remote Access Controller
Admin (RACADM) 子命令和支持的 RACADM 界面的信息请参阅 RACADM CLI Guide for iDRAC
有关 Redfish 及其协议、支持的架构 以及 iDRAC 中实施的 Redfish 的信 息请参阅 Redfish API Guide
有关 iDRAC 属性数据库组和对象说 明的信息请参阅 Attribute Registry Guide
有关较早版本的 iDRAC 说明文件的 信息请参阅 iDRAC 文档。
要识别您的系统上可用的 iDRAC 版 本 iDRAC web 界面单击 ? > 关于
www.dell.com/poweredgemanuals
www.dell.com/poweredgemanuals
www.dell.com/idracmanuals
有关安装该操作系统的信息请参 阅操作系统说明文件。
有关更新驱动程序和固件的信息 请参阅本说明文件中的“下载固件 和驱动程序的方法”部分。
管理系统 有关戴尔提供的系统管理软件的信
请参阅 Dell OpenManage
Systems Management Overview Guide
www.dell.com/ operatingsystemmanuals
www.dell.com/support/drivers
www.dell.com/poweredgemanuals
说明文件资源
23
. 10: 系统其他说明文件资源
任务 说明文件 位置
有关安装、使用 OpenManage 以及 进行故障处理的信息请参阅 Dell
OpenManage Server Administrator Users Guide
有关安装、使用 Dell OpenManage Essentials 以及进行故障处理的信 请参阅 Dell OpenManage Essentials Users Guide
有关安装、使用 Dell OpenManage Enterprise 以及进行故障处理的信 请参阅 Dell OpenManage Essentials Users Guide
有关安装和使用 Dell SupportAssist 的信息请参阅 Dell EMC
SupportAssist Enterprise Users Guide
有关合作伙伴计划企业系统管理的 信息请参阅 OpenManage
Connections Enterprise Systems Management 说明文件。
使用戴尔 PowerEdge RAID 控制器 要了解戴尔 PowerEdge RAID 控制器
www.dell.com/openmanagemanuals
> OpenManage Server Administrator
www.dell.com/openmanagemanuals
> OpenManage Essentials
www.dell.com/openmanagemanuals
> OpenManage Enterprise
https://www.dell.com/ serviceabilitytools
www.dell.com/openmanagemanuals
(PERC)、软件 RAID 控制器或 BOSS
卡的功能以及部署卡的信息请参 阅存储控制器说明文件。
www.dell.com/ storagecontrollermanuals
了解事件和错误消息
风扇控制板固件更新 和设置机箱类型步骤
系统故障处理
有关系统固件和代理用于监控系 统组件生成的事件和错误消息的 信息请参阅“查找错误代码”。
有关更新风扇控制板固件和设置机 箱类型以在 PowerEdge C6300 机柜 中容纳 PowerEdge C6320 PowerEdge C6320p 底座的信息 参阅本文档中的“风扇控制板固件 更新和设置机箱类型步骤”部分。
有关发现和排除 PowerEdge 服务器 问题的信息请参阅 Server
Troubleshooting Guide
www.dell.com/qrl
www.dell.com/poweredgemanuals
www.dell.com/poweredgemanuals
24
说明文件资源
本节概述了系统的技术规格和环境规格。
主题
机箱尺寸
机箱重量
处理器规格
PSU 规格
系统电池规格
内存规格
硬盘驱动器和存储规格
内部 SD 卡插槽
端口和连接器规格
视频规格
环境规格

机箱尺寸

3

技术规格

19: PowerEdge C6300 机柜的机箱尺寸
技术规格
25
. 11: Dell PowerEdge C6300 机柜的尺寸
Xa Xb Y Za含挡板 Za不含挡板 Zb Zc
482.3 毫米 448.0 毫米 86.8 毫米
不适用
41.4 毫米 762.1 毫米 795.9 毫米

机箱重量

. 12: 机箱重量
系统
PowerEdge C6300 机柜和 PowerEdge C6320p 底座
最大重量包括所有底座和硬盘驱动器/SSD
36.5 千克80.4

处理器规格

Dell PowerEdge C6320p 支持四个独立底座中的一个 Intel Xeon Phi 72XXF 72XX 产品系列处理器。

PSU 规格

Dell PowerEdge C6300 机柜支持最多两个交流 (AC) 或高压直流 (HVDC) 电源装置 (PSU)Dell PowerEdge C6320p 不支持混合安装 1400 W 1600 W PSU1400 W 1600 W PSU 可以热插拔如果系统具有电源节流功能则支持任何情况下的热插拔。
. 13: PSU 规格
PSU 散热最大
1400 W 交流
1400 W HVDC
仅限中国
1600 W 交流
1600 W HVDC
5220.763 BTU /小时
5966.586 BTU /小时
频率 电压 最大输入电流
50/60 Hz 200240 V AC
50/60 Hz 100-120 V AC
240 V 直流 9 A
200–240 V AC
240 V 直流 10 A
9 A
12 A
10 A
最大涌入电流峰 值
初始涌入电流不能超 过 55 安培峰 值
二次涌入电流不能超 过 25 安培峰 值
初始涌入电流和二次 涌入电流不能超过 35 安培峰值
26
技术规格

系统电池规格

Dell PowerEdge C6320p 底座支持 CR2032 3.0-V 币形锂电池。

内存规格

PowerEdge C6320p 系统支持 DDR4 寄存式 DIMM (RDIMM) 和低负载 DIMM (LRDIMM)
. 14: 内存规格
内存模块插槽 体系结构 内存容量和级别
六个 288 2400 MT/s DDR4
RDIMM LRDIMM 支持
内存优化操作
: 不能混用速度和容量不同的内存模块。
单列 - 8 GB
双列 - 16 GB
双列 - 32 GB
四列 - 64 GB
最小 RAM 最大 RAM
8 GB 最大 384 GB

硬盘驱动器和存储规格

PowerEdge C6320p 底座支持 SASSATA、固态驱动器 (SSD) SDHC 存储选项。
注: 仅在安装 LSI 2008 夹层卡的情况下才支持 SAS 硬盘驱动器。
. 15: PowerEdge C6320p 底座支持的硬盘驱动器、SSD 和存储选项
每个服务器节点的 2.5 英寸硬盘驱动器 (6 Gbps SATA/SAS) 6
内部用于引导的 1.8 英寸 SSD可选)(120 GB 240 GB 1
用于引导的 SDHC 可选)(最多 16 GB 1

内部 SD 卡插槽

PowerEdge C6320p 底座支持 PCIe 提升板卡上的微型安全数字 (SD) 卡插槽。

端口和连接器规格

USB 端口

PowerEdge C6320p 底座背面板上支持一个 USB 3.0 兼容端口和一个 Micro USB 2.0 兼容端口。
下表说明了有关 USB 规格的更多信息
. 16: USB 规格
PowerEdge C6320p 背面板
一个 9 USB 3.0 兼容端口
一个 4 Micro USB 2.0 兼容端口
注: Micro USB 端口不应用于常规 USB 目的它仅保留用作串行端口。
技术规格
27

NIC 端口

PowerEdge C6320p 底座背面板上支持一个 10/100/1000 Mbps 网络接口控制器 (NIC) 端口和 Mellanox ConnectX-4 VPI EDR /100 GbE 嵌入式端口可选

VGA 端口

视频图形阵列 (VGA) 端口可让您将底座连接到 VGA 显示屏。PowerEdge C6320p 底座在每个底座的背面板上支持一个 15 VGA 端 口。

视频规格

PowerEdge C6320p 底座支持一个具有 16 MB RAM Matrox G200 图形卡。
. 17: 支持的视频分辨率选项
分辨率
640 x 480 6070 81632
800 x 600 607585 81632
1024 x 768 607585 81632
1152 x 864 607585 81632
1280 x 1024 6075 81632
1440 x 900 60 81632
刷新率 (Hz) 颜色深度

环境规格

注: 有关特定系统配置的环境测量值的附加信息请参阅 Dell.com/environmental_datasheets
. 18: 温度规格
温度 规格
存储
连续工作在低于海拔 950 米或 3117 英尺时 在设备无直接光照的情况下10°C 35°C50°F 95°F
40°C 65°C40°F 149°F
: 某些系统配置可能需要降低温度上限。
最高温度梯度操作和存储 20°C/h (36°F/h)
. 19: 相对湿度规格
相对湿度 规格
存储
使用时
5% 95%非冷凝
20% 80%非冷凝),每小时最大湿度变化不超过 10%
. 20: 最大振动规格
最大振动 规格
使用时
存储
28
技术规格
5 Hz–350 Hz 0.26 G
10 Hz-500 Hz 1.88 G
全部操作方向
rms
可持续 15 分钟被测的所有六面
rms
. 21: 最大撞击规格
最大撞击 规格
使用时
存储
在所有操作方向上z 轴正方向上可承受一个 31 G 的撞击脉冲可持续
2.6 毫秒
xy z 轴正负方向上可承受连续六个 27 G 整流方波的撞击脉冲系统 每一面承受一个脉冲),其中速度变化为 235 英寸/(597 厘米/
. 22: 最大海拔高度规格
最大海拔高度 规格
使用时
存储
-15.2 - 3,048 -50 – 10,000 英尺
-15.2 - 10,668 -50 – 35,000 英尺
. 23: 气载污染物级别规范
气载污染物级别 G1依据 ISA-S71.04-1985 定义的标准
. 24: 工作温度降额规格
工作温度降额 规格
高达 35°C (95°F) 最高温度在 950 3,117 英尺以上时按 1°C/300 1°F/547 英尺
降低。
技术规格
29
主题
在启动过程中访问系统功能
设置系统
iDRAC 配置
安装操作系统的选项

在启动过程中访问系统功能

在启动期间可以使用下列按键访问系统功能。
注: PXE 支持仅在 BIOS 引导模式下可用。没有热键可在 UEFI 模式下引导。
击键 说明
4

初始系统设置和配置

F2
F10 进入 LifeCycle Controller Configuration 菜单
F11 进入 BIOS 引导管理器。
F12 启动预引导执行环境 (PXE)/iSCSI 引导。
进入系统设置程序。

设置系统

请完成以下步骤设置您的系统
步骤
1. 打开系统包装。
2. 将系统安装到机架中。有关将系统安装到机架中的更多信息请参阅 Dell.com/poweredgemanualsDell PowerEdge C6320
使用入门指南中的系统
3. 将外围设备连接至系统。
4. 将系统连接至电源插座。
5. 通过按下前面板或背面板上的相应电源按钮或者使用 iDRAC 开启滑架。
6. 开启连接的外围设备。
机架安装单页说明书

iDRAC 配置

集成戴尔远程访问控制器 (iDRAC) 旨在帮助系统管理员提供工作效率并提高 Dell EMC 系统的整体可用性。iDRAC 会提醒管理员注意 系统问题帮助他们执行远程系统管理并减少对物理访问系统的需求。

用于设置 iDRAC IP 地址的选项

您必须根据网络基础架构配置初始网络设置以启用与 iDRAC 之间的通信。您可以使用下面的一种接口来设置 IP 地址
30
初始系统设置和配置
Loading...
+ 162 hidden pages