System Features
This section describes the major hardware and software features of your system. It also provides
information about other documents you may need when setting up your system and how to obtain
technical assistance.
•One or two dual-core AMD Opteron™ processors. One or two quad-core AMD Opteron™
processors (when available).
•A minimum of 1 GB (single-processor systems) or 2 GB (two-processor systems) of 667-MHz
registered parity DDR-II memory modules. Memory is upgradable to a maximum of 32 GB
(two-processor systems) by installing combinations of 512-MB, 1-GB, 2-GB, or 4-GB memory
modules in the eight memory module sockets on the system board. (64 GB of memory will be
supported when 8 GB memory modules are available.)
•Support for up to eight 2.5-inch, internal hot-pluggable Serial Attached SCSI (SAS) or
SATA hard drives.
•The optional media bay provides support for an optional half-height tape backup unit (TBU)
and an optional slim-line 1.44-MB diskette drive.
•An optional slim-line IDE CD, DVD, or combination CD-RW/DVD drive.
NOTE: DVD devices are data only.
•An intrusion switch that signals the appropriate systems management software if the cover
is opened.
•Up to two hot-pluggable, 750-W power supplies in an optional 1 + 1 redundant configuration.
•Four hot-pluggable system cooling fans.
The system board includes the following features:
•A left riser card that has one full-length PCIe x8 lane slot and one half-length PCIe x4 lane slot.
•A center riser card that has one half-length PCIe x8 lane slot.
•A dedicated slot for an integrated SAS host bus adapter, which supports up to four 2.5-inch SAS
or SATA hard drives, or an optional RAID controller card with 256 MB of cache memory and
a RAID battery, which supports up to eight 2.5-inch SAS or SATA hard drives.
NOTE: System boot is not supported from an external device attached to a SAS or SCSI adapter,
including SAS 5/E, PERC 5/E, or PERC 4e/DC. See support.dell.com for the latest support information
about booting from external devices.
•Two integrated Gigabit Ethernet NICs, capable of supporting 10-Mbps, 100-Mbps,
and 1000-Mbps data rates.
Getting Started With Your System3
•Four external USB 2.0-compliant connectors (two on the front and two on the back) supporting
a diskette drive, a DVD-ROM drive, a keyboard, a mouse, or a USB flash drive.
•One internal USB 2.0-compliant connector supporting an optional bootable USB flash drive
for customized boot configurations.
•Optional remote access controller (RAC) for remote systems management.
•An integrated VGA-compatible video subsystem based on an integrated ATI ES1000 33-MHz PCI
video controller. The video subsystem includes 32MB of graphics memory and supports various
2D graphics video modes. Maximum resolution is 1600x1200 with 65,536 colors. (When the optional
RAC is installed, the maximum resolution of the integrated video subsystem is 1280x1024.)
•Systems management circuitry that monitors operation of the system fans as well as critical system
voltages and temperatures. The systems management circuitry works in conjunction with the systems
management software.
•Standard Baseboard Management Controller (BMC) with serial and LAN access.
•Back-panel connectors include one serial, one video, two USB, and two NIC connectors.
•Front-panel connectors include a video and two USB connectors.
•Front-panel 1x5 LCD for system ID and error messaging.
•System ID button on the front and back panels.
For more information about specific features, see Technical Specifications.
Supported Operating Systems
•Microsoft® Windows Server® 2003 R2 Standard and Enterprise Editions (SP1 and later)
•Microsoft Windows Server 2003 R2 Standard and Enterprise x64 Editions (SP1 and later)
®
•Red Hat
•Red Hat
Enterprise Linux® AS and ES (Version 4) (x86)
®
Enterprise Linux® AS and ES (Version 4) (x86_64)
•Red Hat Enterprise Linux Server 5 (x86)
•Red Hat Enterprise Linux Server 5 (x86_64)
®
•SUSE
NOTE: For the latest information on supported operating systems, see www.dell.com.
Linux Enterprise Server 10 (x86_64)
4Getting Started With Your System
Other Information You May Need
CAUTION: The Product Information Guide provides important safety and regulatory information.
Warranty information may be included within this document or as a separate document.
•The
•The
•CDs included with your system provide documentation and tools for configuring and managing
•Systems management software documentation describes the features, requirements, installation,
•Operating system documentation describes how to install (if necessary), configure, and use
•Documentation for any components you purchased separately provides information to configure
•Updates are sometimes included with the system to describe changes to the system, software,
•Release notes or readme files may be included to provide last-minute updates to the system or
Rack Installation Guide
describes how to install your system into a rack.
Hardware Owner’s Manual
to troubleshoot the system and install or replace system components.
your system.
and basic operation of the software.
the operating system software.
and install these options.
and/or documentation.
NOTE: Always check for updates on support.dell.com and read the updates first because they often
supersede information in other documents.
documentation or advanced technical reference material intended for experienced users or technicians.
or
Rack Installation Instructions
provides information about system features and describes how
included with your rack solution
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does not perform as expected,
see your Hardware Owner’s Manual.
Dell™ Enterprise Training and Certification is available; see www.dell.com/training for more
information. This service may not be offered in all locations.
Installation and Configuration
CAUTION: Before performing the following procedure, read and follow the safety instructions and important
regulatory information in your Product Information Guide.
This section describes the steps to set up your system for the first time.
Getting Started With Your System5
Unpacking the System
Unpack your system and identify each item.
Keep all shipping materials in case you need them later.
Installing the Rails and System in a Rack
Once you have read the "Safety Instructions" located in the rack installation documentation
for your system, install the rails and the system in the rack.
See your rack installation documentation for instructions on installing your system in a rack.
6Getting Started With Your System
Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable to plug into
each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.
Connecting the Power
Connect the monitor’s power cable to the monitor (optional), and connect the system’s power
cable(s) to the system.
Getting Started With Your System7
Installing the Power Cord Retention Bracket
Attach the power cord retention bracket on the right bend of the power supply handle. Bend
the system power cable into a loop as shown in the illustration and attach to the bracket’s cable
clasp. Repeat the procedure for the second power supply.
Plug the other end of the power cables into a grounded electrical outlet or a separate power source
such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
Turning on the System
Turn on the system and monitor (optional).
With the bezel removed, press the power button on the system and the monitor. The power
indicators should light. Adjust the monitor's controls until the displayed image is satisfactory.
8Getting Started With Your System
Installing the Bezel
Install the bezel (optional).
Complete the 0perating System Setup
If you purchased a preinstalled operating system, see the operating system documentation that ships with
your system. To install an operating system for the first time, see the Quick Installation Guide. Be sure the
operating system is installed before installing hardware or software not purchased with the system.
Technical Specifications
Processor
Processor typeOne or two dual-core AMD Opteron processors
One or two quad-core AMD Opteron processors
(when available)
Expansion Bus
Bus type PCIe
Expansion slots
Center riser:
PCIe
Left riser
PCIe option:
One x8 full-height, half-length 3.3-V slot
One x8 full-height, full-length 3.3-V slot
One x4 full-height, half-length 3.3-V slot
Video typeATI ES1000 video controller; VGA connector
Video memory 32 MB
Power
AC power supply (per power supply)
Wattage
Vo lt ag e
Heat dissipation
Maximum inrush current
Batteries
System battery
RAID battery (optional)
Physical
Rack
Height
Width
Depth
Weight (maximum configuration)
750 W
85–264 VAC, autoranging, 47–63 Hz
2697 BTU/hr maximum
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 55 A per power supply for
10 ms or less.
CR 2032 3.0-V lithium ion coin cell
4.1-V lithium ion
8.656 cm (3.40 in)
44.7 cm (17.6 in)
75.68 cm (29.79 in)
26.76 kg (59 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations,
see www.dell.com/environmental_datasheets.
Te mp e ra t ur e
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
Getting Started With Your System11
Environmental (continued)
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing) with a maximum
humidity gradation of 10% per hour
0.26 Grms at 5–350 Hz in operational
orientations
1.54 Grms at 10–250 Hz in all orientations
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms
in the operational orientation
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)
12Getting Started With Your System
Systèmes Dell™ PowerEdge™ 2970
Guide de mise en route
www.dell.com | support.dell.com
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.