Dell MD3820I, MD3800I User Manual

Dell PowerVault MD3800i and MD3820i Storage Arrays
Owner's Manual
Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2015 - 10
Rev. A01
Contents
1 About Your System............................................................................................... 6
Introduction...........................................................................................................................................6
Front-Panel Features and Indicators.................................................................................................... 6
Back-Panel Features and Indicators.....................................................................................................9
Physical-Drive Indicator Patterns......................................................................................................... 9
Power Supply and Cooling Fan Features........................................................................................... 10
Power Indicator Codes and Features................................................................................................. 10
Related Documentation...................................................................................................................... 11
2 Controller Modules.............................................................................................12
RAID Controller Modules.................................................................................................................... 12
RAID Controller Module Connectors And Features...........................................................................12
RAID Controller Module—Additional Features...................................................................................14
Battery Backup Unit.......................................................................................................................14
Storage Array Thermal Shutdown.................................................................................................14
System Password Reset.................................................................................................................14
Cache Functions and Features............................................................................................................15
Cache Mirroring.............................................................................................................................15
Write-Back Cache..........................................................................................................................15
Write-Through Cache................................................................................................................... 15
3 Installing Array Components............................................................................16
Recommended Tools..........................................................................................................................16
Front Bezel (Optional)......................................................................................................................... 16
Removing the Front Bezel.............................................................................................................16
Installing the Front Bezel............................................................................................................... 17
Physical Drives..................................................................................................................................... 17
SAFETY Models AMT E03J and E04J............................................................................................ 17
Removing a 2.5 Inch Physical-Drive Blank................................................................................... 17
Installing a 2.5 Inch Physical-Drive Blank..................................................................................... 17
Removing a 3.5 Inch Physical-Drive Blank...................................................................................18
Installing a 3.5 Inch Physical-Drive Blank.....................................................................................18
Removing a Hot-Swap Physical Drive.......................................................................................... 18
Installing a Hot-Swap Physical Drive............................................................................................ 19
Removing a Physical Drive From a Physical-Drive Carrier..........................................................20
Installing a Physical Drive Into a Physical-Drive Carrier...............................................................21
RAID Controller Module ..................................................................................................................... 21
Removing a RAID Controller Module Blank................................................................................. 22
3
Installing a RAID Controller Module Blank................................................................................... 22
Removing a RAID Controller Module .......................................................................................... 23
Installing a RAID Controller Module ............................................................................................ 23
Opening the RAID Controller Module .........................................................................................24
Closing the RAID Controller Module............................................................................................24
RAID Controller Module Backup Battery Unit ...................................................................................25
Removing the RAID Controller Module Backup Battery Unit .....................................................25
Installing the RAID Controller Module Backup Battery Unit........................................................25
Power Supply/Cooling Fan Module................................................................................................... 26
Removing a Power Supply/Cooling Fan Module.........................................................................26
Installing a Power Supply/Cooling Fan Module........................................................................... 27
Control Panel...................................................................................................................................... 28
Removing the Control Panel........................................................................................................ 28
Installing the Control Panel.......................................................................................................... 29
Backplane............................................................................................................................................30
Removing the Backplane..............................................................................................................30
Installing the Backplane.................................................................................................................31
4 Troubleshooting Your System......................................................................... 32
Safety First—For You and Your System.............................................................................................. 32
Troubleshooting Storage Array Startup Failure..................................................................................32
Troubleshooting Loss of Communication.........................................................................................32
Troubleshooting External Connections............................................................................................. 32
Troubleshooting Power Supply/Cooling Fan Modules..................................................................... 33
Troubleshooting Array Cooling Problems......................................................................................... 33
Troubleshooting Expansion Enclosure Management Modules........................................................ 34
If EMM Status LED is Blinking Amber (5 Times per Sequence) ...................................................34
If the EMM Status LED is Solid or Blinking Amber (2 or 4 Times per Sequence)........................ 34
If the Link Status LEDs are not Green...........................................................................................34
Troubleshooting RAID Controller Modules....................................................................................... 34
If the Array Status LED is Solid or Blinking Amber........................................................................35
If the Link Status LEDs are not Green...........................................................................................35
Troubleshooting Physical Disks..........................................................................................................35
Troubleshooting Array and Expansion Enclosure Connections....................................................... 36
Troubleshooting a Wet System.......................................................................................................... 36
Troubleshooting a Damaged System................................................................................................. 37
Controller Failure Conditions............................................................................................................. 37
Critical Conditions.........................................................................................................................37
Noncritical Conditions.................................................................................................................. 38
Invalid Storage Array..................................................................................................................... 38
ECC Errors..................................................................................................................................... 38
PCI Errors.......................................................................................................................................38
4
5 Technical Specifications....................................................................................39
6 Getting help.........................................................................................................43
Locating your system Service Tag......................................................................................................43
Contacting Dell................................................................................................................................... 43
Documentation feedback...................................................................................................................43
5
1

About Your System

Introduction

The MD3800i and MD3820i Series storage array is designed for high availability, offering redundant access to data storage. Its features support both single and dual RAID controller configurations.
The Dell PowerVault MD3800i and 3820i Series storage array provides 10 G/1000 BaseT connectivity to the host server. It enables access to 64 physical hosts.
The MD3800i and MD3820i Series storage array includes a number of components. These components are:
RAID controller module(s)
PSU/fan modules
Disk drives (also called physical disks/hard drives in this document)
A front bezel (optional)
A system enclosure, into which the other components are plugged

Front-Panel Features and Indicators

Figure 1. Front-Panel Features and Indicators—Dell PowerVault MD3800i
6
Figure 2. Front-Panel Features and Indicators—Dell PowerVault MD3820i
Figure 3. Front-Bezel Features and Indicators
Table 1. Front-Panel Features and Indicators
Item Indicator, Button, or Connector Description
1 Enclosure status LED The enclosure status LED lights when the
enclosure power is on. Lights blue during normal operation.
7
Item Indicator, Button, or Connector Description
Blinks blue when a host server is identifying the enclosure or when the system identification button is pressed.
Lights amber as enclosure boots or is reset.
Blinks amber when the enclosure is either in a fault state or the hosts are not using the preferred path to a virtual disk.
2 Power LED The power LED lights green when at least one
power supply is supplying power to the enclosure.
3 Split mode LED This LED must be unlit as the split mode function is
not supported by the MD3800i Series Storage Arrays.
4 System identification button The system identification button on the front
control panel can be used to locate a particular enclosure within a rack. When the button is pushed, the system status indicators on the control panel and the RAID controller module(s) blink blue until the button is pushed again.
5 Hard drives MD3800i —Up to twelve 3.5 inch SAS hot-
swappable hard drives. MD3820i —Up to twenty four 2.5 inch SAS hot-
swappable hard drives.
6 Enclosure mode switch The function of this switch is not applicable to your
storage array. However, if MD1200 Series expansion enclosures are daisy chained to the storage array, the enclosure mode switches of the MD1200 Series expansion enclosures must be set to the Unified-Mode position.
NOTE: This switch must be set before turning on the MD1200 Series expansion enclosure. Changing the switch setting after the expansion enclosure is turned on has no effect on the enclosure configuration until the expansion enclosure goes through a complete power cycle.
8

Back-Panel Features and Indicators

Figure 4. Back-Panel Features and Indicators—Dell PowerVault MD3800i and MD3820i Series
1. 600 W power supply/cooling fan 2. RAID Controller Module 0
3. RAID Controller Module 1 4. 600 W power supply/cooling fan

Physical-Drive Indicator Patterns

Figure 5. Physical-Drive Indicators
1. physical-drive activity indicator (green) 2. physical-drive status indicator (green and
NOTE: If the physical drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains off.
Table 2. Physical-Drive Indicators
Drive-Status Indicator Pattern (RAID Only)
Blinks green two times per second
Off Drive ready for insertion or removal
Condition
Identifying drive or preparing for removal
amber)
9
Drive-Status Indicator Pattern (RAID Only)
Condition
NOTE: The drive status indicator remains off until all physical drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time.
Blinks green, amber, and turns off
Blinks amber four times per second
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three seconds, and turns off six seconds
Predicted drive failure
Drive failed
Rebuild aborted

Power Supply and Cooling Fan Features

The MD3800i and MD3820i Series storage array includes two integrated, hot-swappable power supply/ cooling fan modules. Both modules must be installed to ensure proper cooling. The system requires at least one of the cooling fans to function, to avoid overheating.
A power supply/cooling fan module can be replaced without powering down the system. For information on removing and installing the modules, see Power Supply/Cooling Fan Module.

Power Indicator Codes and Features

Figure 6. Power Indicator Codes and Features
10
Table 3. Power Indicator Codes and Features
Item LED Type Icon Description
1 DC power The LED lights green when the DC output voltage is within
the limit.
If this LED is off, it indicates that the DC output voltage are not within the limit.
2 Power supply/
cooling fan fault
3 AC power The LED lights green when the AC input voltage is within
4 Power
connector
5 Power switches
(2)
The LED lights amber when the DC output voltage is not within the limit or a fault with the fan is detected.
If this LED is off, it indicates that no fault condition is present.
the limit.
If this LED is off, it indicates either there is no power or the AC input voltage is not within the limit.
Connect the external power supply to this connector.
The power switch controls the power supply output to the enclosure.

Related Documentation

NOTE: For all PowerVault documentation, go to dell.com/powervaultmanuals.
NOTE: For all Dell OpenManage documents, go to dell.com/openmanagemanuals.
NOTE: For all storage controller documents, go to dell.com/storagecontrollermanuals.
You product documentation includes:
Dell PowerVault MD3400/3420/3800i/3820i/3800f/3820f Storage Arrays Getting Started Guide
Provides an overview of system features, setting up your system, and technical specifications. This
document is shipped with your system.
Rack Installation Instructions — Describes how to install your system into a rack. This document is
shipped with your rack solution.
Dell PowerVault MD Series Storage Arrays Administrator's Guide — Provides information about
configuring and managing the system using the MDSM GUI.
Dell PowerVault Modular Disk Storage Arrays CLI Guide — Provides information about configuring and
managing the system using the MDSM CLI.
Dell PowerVault MD3800i and MD3820i Storage Arrays Deployment Guide — Provides information
about deploying the storage system in the SAN architecture.
Dell PowerVault MD34xx and 38xx Series Support Matrix — Provides information about the software
and hardware compatibility matrices for the storage array.
11
2

Controller Modules

RAID Controller Modules

The RAID controller modules provide high-performance, advanced virtual disk configuration, and fault­tolerant disk subsystem management. Each RAID controller module contains 4GB or 8GB of mirrored cache for high availability and a battery-powered cache offload mechanism.
NOTE: The 8GB mirrored cache is an optional feature.
RAID controller modules provide the following data path and enclosure management functions:
Monitoring and controlling enclosure environment elements (temperature, fans, power supplies, and
enclosure LEDs)
Controlling access to the physical disks
Communicating enclosure attributes and states to the host server and management station
Each RAID controller module has multiple iSCSI IN ports for host access. The ports provide redundant host connections and support a high availability storage environment. Various configurations can be utilized, in both single controller (simplex) and dual controller (duplex) modes, to connect the storage enclosure to hosts depending on specific redundancy needs.
For information on cabling, see the MD3800i and MD3820i Series Storage Arrays Deployment Guide, at
dell.com/powervaultmanuals.

RAID Controller Module Connectors And Features

Figure 7. MD3800i and MD3820i Series iSCSI RAID Controller Module
12
Table 4. RAID Controller Module Connectors And Features
Item Component Function
1 10 Gbps iSCSI IN port (2) Provides host-to-controller iSCSI 10 Gbps Ethernet
connection.
2 Seven segment display
Displays status or error codes for the storage array.
sequence
3 Controller power LED Lights green when controller power is on.
Turns off when controller is not powered.
4 Controller fault LED Lights amber when controller fault is detected.
Turns off when controller is operating normally.
5 System identification LED Blinks blue when system identification switch push-
button on enclosure front panel is pressed.
6 Cache active or cache offload
LED
Lights green when on-board controller memory contains data.
If AC power fails, this LED changes to indicate Cache Offload status. If the password reset function has successfully changed the password, this LED flashes on and off briefly.
NOTE: The password reset switch is not available if your system was shipped after September, 2015. The password reset switch functionality was disabled starting from controller firmware 08.20.09.60 and later versions.
7 Battery fault Lights amber when battery backup unit or battery has
failed.
Turns off when battery backup unit is operating normally.
8 Management port Provides a 100/1000 Mbps Ethernet connection for
out-of-band management of the enclosure.
9 Ethernet port (reserved) Reserved port.
10 SAS IN port (2) Provides host-to-controller SAS connection.
11 USB port This port is a reserved port.
12 Mini USB port Provides serial connection for debugging.
13 Password reset switch Activating this switch resets the password.
13
Loading...
+ 30 hidden pages