intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other
jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2015 - 10
Rev. A01
Contents
1 About Your System............................................................................................... 6
The MD3800i and MD3820i Series storage array is designed for high availability, offering redundant
access to data storage. Its features support both single and dual RAID controller configurations.
The Dell PowerVault MD3800i and 3820i Series storage array provides 10 G/1000 BaseT connectivity to
the host server. It enables access to 64 physical hosts.
The MD3800i and MD3820i Series storage array includes a number of components. These components
are:
•RAID controller module(s)
•PSU/fan modules
•Disk drives (also called physical disks/hard drives in this document)
•A front bezel (optional)
•A system enclosure, into which the other components are plugged
Front-Panel Features and Indicators
Figure 1. Front-Panel Features and Indicators—Dell PowerVault MD3800i
6
Figure 2. Front-Panel Features and Indicators—Dell PowerVault MD3820i
Figure 3. Front-Bezel Features and Indicators
Table 1. Front-Panel Features and Indicators
ItemIndicator, Button, or ConnectorDescription
1Enclosure status LEDThe enclosure status LED lights when the
enclosure power is on.
Lights blue during normal operation.
7
ItemIndicator, Button, or ConnectorDescription
Blinks blue when a host server is identifying the
enclosure or when the system identification button
is pressed.
Lights amber as enclosure boots or is reset.
Blinks amber when the enclosure is either in a fault
state or the hosts are not using the preferred path
to a virtual disk.
2Power LEDThe power LED lights green when at least one
power supply is supplying power to the enclosure.
3Split mode LEDThis LED must be unlit as the split mode function is
not supported by the MD3800i Series Storage
Arrays.
4System identification buttonThe system identification button on the front
control panel can be used to locate a particular
enclosure within a rack. When the button is
pushed, the system status indicators on the control
panel and the RAID controller module(s) blink blue
until the button is pushed again.
5Hard drivesMD3800i —Up to twelve 3.5 inch SAS hot-
swappable hard drives.
MD3820i —Up to twenty four 2.5 inch SAS hot-
swappable hard drives.
6Enclosure mode switchThe function of this switch is not applicable to your
storage array. However, if MD1200 Series
expansion enclosures are daisy chained to the
storage array, the enclosure mode switches of the
MD1200 Series expansion enclosures must be set
to the Unified-Mode position.
NOTE: This switch must be set before turning
on the MD1200 Series expansion enclosure.
Changing the switch setting after the
expansion enclosure is turned on has no effect
on the enclosure configuration until the
expansion enclosure goes through a complete
power cycle.
8
Back-Panel Features and Indicators
Figure 4. Back-Panel Features and Indicators—Dell PowerVault MD3800i and MD3820i Series
1.600 W power supply/cooling fan2.RAID Controller Module 0
3.RAID Controller Module 14.600 W power supply/cooling fan
Physical-Drive Indicator Patterns
Figure 5. Physical-Drive Indicators
1.physical-drive activity indicator (green)2.physical-drive status indicator (green and
NOTE: If the physical drive is in Advanced Host Controller Interface (AHCI) mode, the status
indicator (on the right side) does not function and remains off.
Table 2. Physical-Drive Indicators
Drive-Status Indicator Pattern
(RAID Only)
Blinks green two times per
second
OffDrive ready for insertion or removal
Condition
Identifying drive or preparing for removal
amber)
9
Drive-Status Indicator Pattern
(RAID Only)
Condition
NOTE: The drive status indicator remains off until all physical
drives are initialized after the system is turned on. Drives are not
ready for insertion or removal during this time.
Blinks green, amber, and turns
off
Blinks amber four times per
second
Blinks green slowlyDrive rebuilding
Steady greenDrive online
Blinks green three seconds,
amber three seconds, and
turns off six seconds
Predicted drive failure
Drive failed
Rebuild aborted
Power Supply and Cooling Fan Features
The MD3800i and MD3820i Series storage array includes two integrated, hot-swappable power supply/
cooling fan modules. Both modules must be installed to ensure proper cooling. The system requires at
least one of the cooling fans to function, to avoid overheating.
A power supply/cooling fan module can be replaced without powering down the system. For information
on removing and installing the modules, see Power Supply/Cooling Fan Module.
Power Indicator Codes and Features
Figure 6. Power Indicator Codes and Features
10
Table 3. Power Indicator Codes and Features
ItemLED TypeIconDescription
1DC powerThe LED lights green when the DC output voltage is within
the limit.
If this LED is off, it indicates that the DC output voltage are
not within the limit.
2Power supply/
cooling fan fault
3AC powerThe LED lights green when the AC input voltage is within
4Power
connector
5Power switches
(2)
The LED lights amber when the DC output voltage is not
within the limit or a fault with the fan is detected.
If this LED is off, it indicates that no fault condition is
present.
the limit.
If this LED is off, it indicates either there is no power or the
AC input voltage is not within the limit.
Connect the external power supply to this connector.
The power switch controls the power supply output to the
enclosure.
Related Documentation
NOTE: For all PowerVault documentation, go to dell.com/powervaultmanuals.
NOTE: For all Dell OpenManage documents, go to dell.com/openmanagemanuals.
NOTE: For all storage controller documents, go to dell.com/storagecontrollermanuals.
You product documentation includes:
•Dell PowerVault MD3400/3420/3800i/3820i/3800f/3820f Storage Arrays Getting Started Guide —
Provides an overview of system features, setting up your system, and technical specifications. This
document is shipped with your system.
•Rack Installation Instructions — Describes how to install your system into a rack. This document is
shipped with your rack solution.
•Dell PowerVault MD Series Storage Arrays Administrator's Guide — Provides information about
configuring and managing the system using the MDSM GUI.
•Dell PowerVault Modular Disk Storage Arrays CLI Guide — Provides information about configuring and
managing the system using the MDSM CLI.
•Dell PowerVault MD3800i and MD3820i Storage Arrays Deployment Guide — Provides information
about deploying the storage system in the SAN architecture.
•Dell PowerVault MD34xx and 38xx Series Support Matrix — Provides information about the software
and hardware compatibility matrices for the storage array.
11
2
Controller Modules
RAID Controller Modules
The RAID controller modules provide high-performance, advanced virtual disk configuration, and faulttolerant disk subsystem management. Each RAID controller module contains 4GB or 8GB of mirrored
cache for high availability and a battery-powered cache offload mechanism.
NOTE: The 8GB mirrored cache is an optional feature.
RAID controller modules provide the following data path and enclosure management functions:
•Monitoring and controlling enclosure environment elements (temperature, fans, power supplies, and
enclosure LEDs)
•Controlling access to the physical disks
•Communicating enclosure attributes and states to the host server and management station
Each RAID controller module has multiple iSCSI IN ports for host access. The ports provide redundant
host connections and support a high availability storage environment. Various configurations can be
utilized, in both single controller (simplex) and dual controller (duplex) modes, to connect the storage
enclosure to hosts depending on specific redundancy needs.
For information on cabling, see the MD3800i and MD3820i Series Storage Arrays Deployment Guide, at
dell.com/powervaultmanuals.
RAID Controller Module Connectors And Features
Figure 7. MD3800i and MD3820i Series iSCSI RAID Controller Module
12
Table 4. RAID Controller Module Connectors And Features
ItemComponentFunction
110 Gbps iSCSI IN port (2)Provides host-to-controller iSCSI 10 Gbps Ethernet
connection.
2Seven segment display
Displays status or error codes for the storage array.
sequence
3Controller power LEDLights green when controller power is on.
Turns off when controller is not powered.
4Controller fault LEDLights amber when controller fault is detected.
Turns off when controller is operating normally.
5System identification LEDBlinks blue when system identification switch push-
button on enclosure front panel is pressed.
6Cache active or cache offload
LED
Lights green when on-board controller memory
contains data.
If AC power fails, this LED changes to indicate Cache
Offload status. If the password reset function has
successfully changed the password, this LED flashes
on and off briefly.
NOTE: The password reset switch is not
available if your system was shipped after
September, 2015. The password reset switch
functionality was disabled starting from
controller firmware 08.20.09.60 and later
versions.
7Battery faultLights amber when battery backup unit or battery has
failed.
Turns off when battery backup unit is operating
normally.
8Management portProvides a 100/1000 Mbps Ethernet connection for
out-of-band management of the enclosure.
9Ethernet port (reserved)Reserved port.
10SAS IN port (2)Provides host-to-controller SAS connection.
11USB port This port is a reserved port.
12Mini USB portProvides serial connection for debugging.
13Password reset switchActivating this switch resets the password.
13
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.