ConnectX®-2 Dual Port I/O Card for Dell C6100
User Manual
MCQH29-XDR
Rev 1.0
www.mellanox.com
NOTE:
THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTA TION ARE PROVIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF
AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUS
TOMER'S MANUF ACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES
TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CAN
NOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY.
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANT ABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT
SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED
DOCUMENT ATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
-
-
Mellanox Technologies
350 Oakmead Parkway Suite 100
Sunnyvale, CA 94085
U.S.A.
www.mellanox.com
Tel: (408) 970-3400
Fax: (408) 970-3403
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
About this Manual
This User Manual describes ConnectX-2 Dual Port VPI I/O cards for the Dell C6100 chassis.
It provides details as to the interfaces of the board, specifications, required software and firmware
for operating the cards, installation instructions, and relevant documentation.
Intended Audience
This manual is intended for the installer and user of the I/O cards.
The manual assumes basic familiarity with the Infiniband
1.2.1– Infiniband Architecture Specifications Descriptions
PCI Express Base 2.0 Specification (1.1 compatible)
PCI Local Bus Specification Rev 2.3
Online Resources
• Mellanox Technologies Web pages: http://www.mellanox.com
• Dell Support Web pages: http://support.dell.com
Document Conventions
®
architecture specifications.
These symbols indicate a situation, status, or condition that may cause harm
to people or damage to the equipment.
When discussing memory sizes, MB and MBytes are used in this document to mean size in mega
bytes. The use of Mb or Mbits (small b) indicates size in mega bits.
Mellanox Technologies
7
1Overview
This document is a User Manual for the Mellanox ConnectX-2 20 and 40Gb/s InfiniBand /
10GigE Ethernet dual port QSFP I/O cards for the Dell C6100 chassis.
The cards described in this manual have the following main features:
•1μs MPI ping latency
• Selectable 10, 20, or 40Gb/s InfiniBand or 10GigE per port
• CPU offload of transport operations
• End-to-end QoS and congestion control
• Hardware-based I/O virtualization
• PCI Express 2.0 (up to 5GT/s)
• TCP/UDP/IP stateless offload
• Fibre Channel encapsulation (FCoIB or FCoE)
1.1I/O Card
OverviewRev 1.0
Table 3 - ConnectX-2 I/O Card Details
Ordering Part
Number (OPN)
MCQH29-XDRPCIe Gen2
PCI Express
SERDES
Speed
5.0 GT/s
Transmission
40 Gb/s QDR
IB Data
Rate
InfiniBand
Eth Data
Transmission
Rate
10 Gb/s
RoHS Adapter IC Part Number
R-6MT25408B0-FCCR-QI
8
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
IL-0JR3P1-74031-980-0001
REV:A00
Made in IL
P/N: 0JR3P1REV: X1
Made in IL
GUID: 0024E89097FF24DC
MAC: 0002C9011226 FC
Model No: MCQH29-XDR
1.2Finding the GUID/MAC and Serial Number on the Adapter Cards
All cards have a label on the printed side of the card that has the card serial number, the card MAC
for Ethernet protocol, and the card GUID for InfiniBand protocol. VPI Cards have both a MAC
and a GUID.
Figure 1: Card Product Labels
Mellanox Technologies
9
2I/O Card Interfaces
2.1I/O Interfaces
The ConnectX-2 I/O card is VPI-capable, supporting InfiniBand or Ethernet on either port. Th e
following table shows the supported configurations.
The ConnectX-2 VPI adapter card is compliant with the InfiniBand Architecture Specification,
Release 1.2.1. It has two compliant QSFP InfiniBand ports, with four Tx/Rx pairs of SerDes con-
nected to QSFP connectors.
2.1.2 Ethernet Interface
The ConnectX® -2 VPI adapter card is compliant with the IEEE Std 802.3ae Specification. Each port
can be connected to a 10 Gigabit Ethernet switch through the use of QSFP to SFP+ hybrid cables.
10
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
Table 5 - Physical and Logical Link Indications
Figure 3: Front Panel
Port NumberLED Name
Port 1Physical Link - Green
Constant on indicates a good physical link
Blinking indicates a problem with the Physical link
Data Activity - Yellow
Blinking indicates Data Transfer
Constant on indicates no Data Transfer
Port 2Physical Link - Green
Constant on indicates a good physical link
Blinking indicates a problem with the Physical link
Data Activity - Yellow
Blinking indicates Data Transfer
Constant on indicates no Data Transfer
Physical ConnectionData Transfer
Port 1
Port 2
2.2LED Assignment
2.3PCI Express Interface
The I/O card attaches to the blade's PCI Express interface through a press fit connector. The PCI
Express x8 interface is version 2.0 compliant and compatible with base 1.1 chipsets. The device
can be either a master initiating the PCI Express bus operations or a slave responding to PCI bus
2.4Memory
operations.
The I/O card supports multiple memory devices through the PCI Express, Flash, and I2C compatible interfaces.
2.4.1 System Memory
The I/O card utilizes the PCI Express interface to store and access fabric connection information
on the system memory.
Mellanox Technologies
11
2.4.2 EEPROM
The I/O card incorporates an EEPROM that is accessible through the I2C-compatible interface.
The EEPROM is used for storing the Vital Product Data (VPD). The VPD format adheres to the
PCI Local Bus Specification Rev 2.3 VPD definition. The EEPROM capacity is 4Kb.
2.4.3 Flash
The I/O card includes one SPI Flash device accessible via the Flash interface of the MT25408B0
ConnectX-2 device.
There is a jumper on the card that indicates to the device whether an on-board Flash device is to be
used. Table 6 provides information on this jumper. See the schematic in Figure 14 on page 23 for
the jumper location.
Table 6 - Jumper Configuration
I/O Card InterfacesRev 1.0
DescriptionOption
Flash present/
not present
connection open – Flash present
connection shorted – Flash not present
Figure 4: Flash Jumper
Card Default
Configuration
connection open –
Flash present
Comments
Header 1x2
2.5EEPROM VPD
The I/O card incorporates an EEPROM that is accessible through the I2C-compatible interface.
The EEPROM is used for storing the Vital Product Data (VPD) and FRU. The VPD format
adheres to the PCI Local Bus specification rev 2.3 VPD definition. The EEPROM capacity is 4Kb.
Table 7 - MCQH29-XDR VPD
Offset (Decimal)ItemValueFormatDescription
0Large Resource Type ID String Tag (0x02)0x82
1Length0x12
3Data"DELL PE C6100
MEZZ IB QDR"
21Large Resource Type VPD-R Tag (0x10)0x90Read Only Area
22Length0x43
24VPD Keyword“PN”NumbersAdd in Card Part Number
26Length0x6
27Data“059MP7”
33VPD Keyword“EC”AlphanumericEngineering Change Level of the
35Length0x3
AlphanumericShort description / ID
card (rev)
12
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
Table 7 - MCQH29-XDR VPD
Offset (Decimal)ItemValueFormatDescription
36Data”A00”
39VPD Keyword“SN”AlphanumericSerial Number
41Length0x14
42Data“OO059MP7MM
MMMYMDSSSS
”
62VPD Keyword“V0”Misc Information
64Length0x16
65Data"DELL PE C6100
MEZZ IB QDR"
87VPD Keyword“RV”
89Length0x1
90DataChecksum
91Large Resource Type VPD-W Tag (0x11)0x91Read / W rite Area
92Length0xA1
94VPD Keyword“V1”Driver version
96Length0x6
97Data“N/A”Number
103VPD Keyword“YA”Asset Tag
105Length0x20
106Data“N/A”Alphanumeric
138VPD Keyword“RW”Remaining read/write area
140Length0x72
141DataReserved (0x00)
255Small Resource Type END Tag (0x11)0x78
256Mellanox Read Only Mask0x0....0Numbers
350Mellanox Read/Write Mask0x1...1Numbers
511Mellanox Read Only Mask0x0Numbers
according to the board label
Mellanox Technologies
13
3Driver Software and Firmware
3.1Driver Software
3.1.1 Linux
For Linux, download and install the latest OpenFabrics Enterprise Distribution (OFED) software
package available via the Mellanox Web site at:
http://www.mellanox.com => Downloads => InfiniBand/VPI SW /Drivers. Follow the installation
instructions included in the download package.
3.1.2 Windows
For Windows, download and install the latest WinOF for VPI software package available via the
Mellanox Web site at:
Each card is shipped with the latest version of qualified firmware at the time of manufacturing.
Firmware is updated occasionally, and the most recent firmware can be obtained from
http://www.mellanox.com => Downloads => Firmware.
Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firm-ware Tools (MFT) package. This package is available for download, along with its user manual,
from the Mellanox Firmware Tools page. See http://www.mellanox.com => Downloads => Firmware Tools.
A firmware binaries table lists a binary file per card. The file name of each such binary is composed by combining the firmware name, the firmware release version, and the card part number.
Please contact Mellanox or your assigned Field Application Engineer if you cannot find the firmware binary for your adapter card.
3.3FlexBoot
FlexBoot enables remote boot over Ethernet or InfiniBand using Boot over InfiniBand (BoIB),
Boot over Ethernet (BoE), or Boot over iSCSI (Bo-iSCSI). This technology is based on the Preboot Execution Environment (PXE) standard specification, and FlexBoot software is based on the
open source EtherBoot/gPXE project (see www.etherboot.org). For more information go to
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
4I/O Card Installation
4.1Hardware and Software Requirements
Before installing the VPI I/O card, please make sure that the system meets the hardware and software requirements listed in Table 8, “Hardware and Software Requirements”.
Table 8 - Hardware and Software Requirements
Requirement Description
HardwareUsed with Dell C6100 chassis
Software Operating
Systems/Distributions
Software StacksMellanox OpenFabric software package (either MLNX_OFED for Linux or
4.2Installation Kit
Make sure all of the parts are in the kit before you start the installation. If any parts are damaged or
missing, call your supplier immediately.
1. Connect an ESD strap to your wrist and to a valid ESD ground.
2. Push the latch and pull on the handle.
16
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
Push here
Pull handle
Screws holding the faceplate
Screws in top
Figure 6: Removing From the Server
3. Remove the server and place on a work bench.
4. Above the handle are screws holding on the faceplate.
5. Remove these screws and discard.
6. Remove the two screws on the top side of the server and discard.
7. Remove the faceplate.
8. Push the plastic leg onto the board.
Figure 7: Top View
Mellanox Technologies
17
I/O Card InstallationRev 1.0
Install a flathead screw
through the server into the
metal leg.
Figure 8: Install the Plastic Leg onto the Board
9. Push the Connector board into the card. The connector board must be installed as seen in
Figure 9, directed toward the back of the server.
Figure 9: Installing the Connector Board into the HCA Card
10. Put the card into place in the server, catching the cages into the front panel of the server. The
metal leg must go inside of the server and line up with the hole in the side of the server. Also
push the connector board into the socket in the server.
11. Screw in a flat head screw for the metal leg.
Figure 10: Dell Card Installed
18
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
Screws holding the faceplate
Screws in top
12. Screw in three panhead screws into the front panel.
Figure 11: Front Panel
13. Screw in two flathead screws on the top of the server into the HCA card.
Figure 12: Top View
14. Slide the server in the chassis.
4.4Safety Warnings
1. Installation Instructions
Read all installation instructions before connecting the equipment to the power
source.
Mellanox Technologies
19
2. Over Temperature
This equipment should not be operated in an area with an ambient temperature
exceeding the maximum recommended: 55°C (131°F).
To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around
the ventilation openings.
3. Lightening – Electrical Hazard
During periods of lightning activity, do not work on the equipment.
4. Installation of Equipment
This equipment should be installed, replaced, or serviced only by trained and
qualified personnel.
5. Disposal of Equipment
I/O Card InstallationRev 1.0
Disposal of this equipment should be in accordance to all national laws and
regulations.
6. Compliance with Local and National Codes
This equipment should be installed in compliance with local and national electrical codes.
20
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
5Cables and Modules
These cards support passive copper cables and active optical cables, both direct attach and through
a transceiver module, at up to QDR data rates. See www.mellanox.com => Products => Cables for
cable type, model, module, and length recommendations.
5.1Cable Installation
All cables can be inserted or removed with the unit powered on. To insert a cable, press the connector into the port receptacle until the connector is firmly seated. The GREEN LED indicator will
light when the physical connection is established (that is, when the unit is powered on and a cable
is plugged into the port with the other end of the connector plugged into a functioning port). After
plugging in a cable, lock the connector using the latching mechanism particular to the cable vendor. When a logical connection is made the YELLOW LED will come on. When data is being
transferred the yellow led will blink.
Note: When installing cables make sure that the latches engage.
Note: Always install and remove cables by pushing or pulling the cable and connector in a
straight line with the card.
Care should be taken not to impede the air exhaust flow through the ventilation holes. Cable
lengths should be used which allow for routing horizontally around to the side of the chassis before
bending upward or downward in the rack.
To remove a cable, disengage the loc ks and slowly pull the connector away from the port receptacle. Both LED indicators will turn off when the cable is unseated.
Cables, especially long copper cables, can weigh a substantial amount. Make
sure that the weight of the cable is supported on its own and is not hanging
from the adapter card.
5.1.1 Inserting a Cable into the Card
1. Support the weight of the cable before connecting the cable to the card. Do this by using a
cable holder or tying the cable to the rack.
2. Determine the correct orientation of the connector to the card before inserting the connector.
Do not try and insert the connector up side down. This may damage the card.
3. Insert the connector into the card. Be careful to insert the connector straight into the cage . Do
not apply any torque, up or down, to the connector cage in the card.
4. Make sure that the connector locks in place.
Mellanox Technologies
21
Figure 13: Connector Orientation
180
o
Cables and ModulesRev 1.0
5.1.2 Removing a Cable from the Card
1. Pull on the latch release mechanism thereby unlatching the connector and pull the connector
out of the cage.
2. Do not apply torque to the connector when removing it from the card.
3. Remove any cable supports that were used to support the cable’s weight.
22
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
J2
J3
J5
J4J6
Q1
Q2
U9
U1
U13
H1
H2
H3
J1
L14
U8
U10
U3
U5U6U7
111.90
34.40
59.70
16.60
79.30
10.80
63.90
10.03
57.15
2.60
4.60
I2C interface J2
Flash Jumper J1
Appendix A: Specifications
A.1 Board Mechanical Drawing and Dimensions
The ConnectX-2 I/O card mechanical drawing is depicted in Figure 14.
Figure 14: Mechanical Drawing
J1 is the flash jumper.
J2 is the I2C Connector.
Note: All dimensions are in millimeters.
Mellanox Technologies
23
Rev 1.0
Warning
This is a class A product. In a domestic environment this product
may cause radio interference in which case the user may be
A.2 EMC Certification Statements
A.2.1 FCC Statements (USA)
Class A Statements:
§ 15.21
Statement
Warning! Changes or modifications to this equipment not expressly approved by the party
responsible for compliance (Mellanox Technologies) could void the user's authority to operate
the equipment.
§15.105(a)
Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his
own expense.
A.2.2 EN Statements (Europe)
EN55022 Class A Statement:
A.2.3 ICES Statements (Canada)
Class A Statement:
“This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.”
A.2.4 VCCI Statements (Japan)
Class A Statement:
24
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
(Translation - "This is a Class A product based on the standard of the Voluntary Control Council
for Interference by Information Technology Equipment (VCCI). If this equipment is used in a
domestic environment, radio interference may occur, in which case the user may be required to
take corrective actions.")
A.2.5 KCC Notice (Republic of Korea Only)
The KCC label may be located separately from the other regulatory markings applied to your product.
Class A devices are for business purposes.
Class A Device
KCC Class A Regulatory Label
If the regulatory label includes the following marking, your device is a Class A product:
Mellanox Technologies
25
Rev 1.0
A.3 Specifications
Table 10 - ConnectX-2 MCQH29-XDR Specifications
PhysicalPower and Environmental
Size:
79.30mm X 111.90 mm
Voltage:
12V, 3.3V
Air Flow:
QSFP 40Gb/s
Connector:
200LFM @55°C
InfiniBand (Copper and optical)
Max power per port 3.5 W.
Typ Power:
Maximum Power:
Temperature:
Protocol SupportRegulatory
InfiniBand:
Ethernet:
IBTA v1.2.1, Auto-Negotiation
(20Gb/s@5Gt/s) or
(10Gb/s@2.5Gt/s)
IEEE Std 802.3ae 10 Gigabit
Ethernet
IEEE Std 802.3ad Link Aggregation and Failover
IEEE Std 802.3x Pause
IEEE Std 802.1Q VLAN tags
IEEE Std 802.1p Priorities
Multicast
Jumbo frame support (10KB)
128 MAC/VLAN addresses per
port
QoS:
8 Virtual Lanes for InfiniBand
8 Priority Queues for Ethernet
EMC (Emissions):
Safety:
RoHS:
8.74W Passive cables
12.74W Active cables
10.11W Passive cables
14.11 Active cables
0°C to 55°C
US/Canada: cTUVus
EU: IEC60950
International: CB
USA: FCC, Class A
Canada: ICES, Class A
EU: CE Mark (EN55022 Class A,
EN50024, EN61000-3-2, EN61000-3-
3)
Japan: VCCI, Class A
Korea: KCC Class A
Australia/ New Zealand: C-Tick
Class A
R-6
26
RDMA Support:
Data Rate
SFP+ Ethernet:
QSFP InfiniBand:
PCI Express:
Mellanox Technologies
Yes, All Ports
10 Gb/s
40 Gb/s
2.0 SERDES @ 5.0 GT/s
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
GND
Rx2n
GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
Rx1n
Rx2p
Rx1p
GND
GND
GND
GND
GND
GND
Tx2n
Tx1n
Tx2pTx1p
Tx4n
Tx3n
Tx4p
Tx3p
GND
GND
Rx4n
Rx3n
Rx4p
Rx3p
GND
GND
SDA
SCL
Vcc Rx
ResetL
ModSelLLPMode
Vcc1
VccTx
IntL
ModPrsL
Table 3- InfiniBand QSFP Connector Pinout
Connector
Pin
Number
Connector
Pin Name
Signal Description
1GNDGround
2Tx2nTransmitter Inverted Data Input
3Tx2pTransmitter Non-Inverted Data Input
4GNDGround
5Tx4nTransmitter Inverted Data Input
6Tx4pTransmitter Non-Inverted Data Input
7GNDGround
8ModSelL Module Select
9ResetLModule Reset
10Vcc Rx+3.3 V Power supply receiver
11SCL2-wire serial interface clock
12SDA2-wire serial interface data
13GNDGround
14Rx3pReceiver Non-Inverted Data Output
15Rx3nReceiver Inverted Data Output
16GNDGround
17Rx1pReceiver Non-Inverted Data Output
18Rx1nReceiver Inverted Data Output
19GNDGround
20GNDGround
21Rx2nReceiver Inverted Data Output 3
22Rx2pReceiver Non-Inverted Data Output 3
23GNDGround
24Rx4nReceiver Inverted Data Output 3
25Rx4pReceiver Non-Inverted Data Output 3
26GNDGround
27ModPrsL Module Present
28IntLInterrupt
29Vcc Tx+3.3 V Power supply transmitter
30Vcc 1+3.3 V Power Supply
31LPMode Low Power Mode
32GNDGround
33Tx3pTransmitter Non-Inverted Data Input
34Tx3nTransmitter Inverted Data Input
35GNDGround
36Tx1pTransmitter Non-Inverted Data Input
37Tx1nTransmitter Inverted Data Input
38GNDGround
Appendix B: QSFP Interface
Mellanox Technologies
27
Rev 1.0
18.35
8.50
Top
ResetL
SDA
SCL
ModSelL
RX3p
TX2n
GND
VccRx
1
2
3
4
5
6
7
8
9
1
0
1
2
3
4
5
6
7
8
9
TX2p
GND
TX4n
TX4p
GND
1
1
1
1
1
1
1
1
1
1
20
GND
GND
GND
RX3n
RX1p
RX1n
30
1
2
3
4
5
6
7
8
9
2
2
2
2
2
2
2
2
2
1
2
3
4
5
6
7
8
3
3
3
3
3
3
3
3
RX4p
GND
GND
GND
RX4n
RX2p
RX2n
TX1n
GND
TX1p
GND
TX3n
TX3p
GND
IntL
ModPrsL
VccTx
Vcc1
LPMode
18.35
8.50
Top
ResetL
SDA
SCL
ModSelL
RX3p
TX2n
GND
VccRx
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
TX2p
GND
TX4n
TX4p
GND
1
1
1
1
1
1
1
1
1
1
20
GND
GND
GND
RX3n
RX1p
RX1n
30
RX4p
GND
GND
GND
RX4n
RX2p
RX2n
TX1n
GND
TX1p
GND
TX3n
TX3p
GND
IntL
ModPrsL
VccTx
Vcc1
LPMode
1
2
3
4
5
6
7
8
3
3
3
3
3
3
3
3
1
2
3
4
5
6
7
8
9
2
2
2
2
2
2
2
2
2
View into Front of Cage
View into Rear of
Connector
Figure 15: QSFP Connector Male and Female Views
28
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100Rev 1.0
Appendix C: Avertissements de sécurité d’installation (French)
1. Instructions d’installation
Lisez toutes les instructions d’installation avant de brancher le matériel à la
source d’alimentation électrique.
2. Température excessive
Ce matériel ne doit pas fonctionner dans une zone avec une température ambiante dépassant le maximum recommandé de 55°C (131°F). Un flux d’air de
200LFM à cette température ambiante maximale est nécessaire. En outre, pour
garantir un bon écoulement de l’air, laissez au moins 8 cm (3 pouces) d’espace
libre autour des ouvertures de ventilation.
3. Orages – dangers électriques
Pendant un orage, il ne faut pas utiliser le matériel.
4. Installation du matériel
Ce matériel ne doit être installé, remplacé ou entretenu que par du personnel
formé et qualifié.
5. Elimination du matériel
L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur.
6. Codes électriques locaux et nationaux
Ce matériel doit être installé dans le respect des codes électriques locaux et
nationaux.
Lesen Sie alle Installationsanleitungen, bevor Sie das Gerät an die Stromversorgung anschließen.
2. Übertemperatur
Dieses Gerät sollte nicht in einem Bereich mit einer Umgebungstemperatur
über der maximal empfohlenen Temperatur von 55°C (131°F) betrieben
werden. Außerdem sollten mindestens 8 cm (3 in.) Freiraum um die Belüftungsöffnungen sein, um einen einwandfreien Luftstrom zu gewährleisten.
3. Bei Gewitter - Elektrische Gefahr
Arbeiten Sie während eines Gewitters und Blitzschlag nicht am Gerät.
4. Geräteinstallation
Diese Gerät sollte nur von geschultem und qualifiziertem Personal installiert,
ausgetauscht oder gewartet werden.
5. Geräteentsorgung
Die Entsorgung dieses Geräts sollte unter Beachtung aller nationalen Gesetze
Bestimmungen erfolgen.
6. Regionale und nationale elektrische Bestimmungen
Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen
Bestimmungen installiert werden.
30
Mellanox Technologies