Dell MCQH29-XDR User Manual

Dell and the Dell logo are trademarks of Dell Inc.
ConnectX®-2 Dual Port I/O Card for Dell C6100
User Manual
MCQH29-XDR
www.mellanox.com
NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTA TION ARE PRO­VIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUS TOMER'S MANUF ACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CAN NOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY. ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MER­CHANT ABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEM­PLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCURE­MENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED DOCUMENT ATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
-
-
Mellanox Technologies 350 Oakmead Parkway Suite 100 Sunnyvale, CA 94085 U.S.A. www.mellanox.com Tel: (408) 970-3400 Fax: (408) 970-3403
© Copyright 2010. Mellanox Technologies, Inc. All Rights Reserved. Mellanox®, ConnectX®, BridgeX®, InfiniBlast®, InfiniBridge®, InfiniHost®, InfiniRISC®, InfiniScale®, and InfiniPCI® are registered trademarks of Mellanox Technologies, Ltd. PhyX and Virtual Protocol Interconnect are trademarks of Mellanox Technologies, Ltd.
All other marks and names mentioned herein may be trademarks of their respective companies.
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100
2
Mellanox Technologies
Mellanox Technologies, Ltd. PO Box 586 Hermon Building Yokneam 20692 Israel Tel: +972-4-909-7200 Fax: +972-4-959-3245
Document Number: 3198
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
Table of Contents
Chapter 1 Overview 8
1.1 I/O Card 8
1.2 Finding the GUID/MAC and Serial Number on the Adapter Cards 9
Chapter 2 I/O Card Interfaces 10
2.1 I/O Interfaces 10
2.1.1 InfiniBand Interface 10
2.1.2 Ethernet Interface 10
2.2 LED Assignment 11
2.3 PCI Express Interface 11
2.4 Memory 11
2.4.1 System Memory 11
2.4.2 EEPROM 12
2.4.3 Flash 12
2.5 EEPROM VPD 12
Chapter 3 Driver Software and Firmware 14
3.1 Driver Software 14
3.1.1 Linux 14
3.1.2 Windows 14
3.2 Updating Card Firmware 14
3.3 FlexBoot 14
Chapter 4 I/O Card Installation 15
4.1 Hardware and Software Requirements 15
4.2 Installation Kit 15
4.3 Installation Instructions 16
4.4 Safety Warnings 19
Chapter 5 Cables and Modules 21
5.1 Cable Installation 21
5.1.1 Inserting a Cable into the Card 21
5.1.2 Removing a Cable from the Card 22
Appendix A Specifications 23 Appendix B QSFP Interface 27 Appendix C Avertissements de sécurité d’installation (French) 29 Appendix D Installation - Sicherheitshinweise (German) 30
Mellanox Technologies
3
Rev 1.0
List of Figures
Figure 1: Card Product Labels 9 Figure 2: PCI Connection 10 Figure 3: Front Panel 11 Figure 4: Flash Jumper 12 Figure 5: Installation Kit Parts 16 Figure 6: Removing From the Server 17 Figure 7: Top View 17 Figure 8: Install the Plastic Leg onto the Board 18 Figure 9: Installing the Connector Board into the HCA Card 18 Figure 10: Dell Card Installed 18 Figure 11: Front Panel 19 Figure 12: Top View 19 Figure 13: Connector Orientation 22 Figure 14: Mechanical Drawing 23 Figure 15: QSFP Connector Male and Female Views 28
4
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
List of Tables
Table 1: Revision History Table 6 Table 2: Documents List 7 Table 3: ConnectX-2 I/O Card Details 8 Table 4: VPI Support 10 Table 5: Jumper Configuration 12 Table 6: MCQH29-XDR VPD 12 Table 7: Hardware and Software Requirements 15 Table 8: ConnectX® Dual-Port InfiniBand I/O Card Installation Kit 16 Table 9: ConnectX-2 MCQH29-XDR Specifications 26
Mellanox Technologies
5
Rev 1.0

Revision History

This document was first printed on 5/6/10.
Table 1 - Revision History Table
Date Rev Comments/Changes
April 2010 1.0 Initial release
6
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0

About this Manual

This User Manual describes ConnectX-2 Dual Port VPI I/O cards for the Dell C6100 chassis.
It provides details as to the interfaces of the board, specifications, required software and firmware for operating the cards, installation instructions, and relevant documentation.

Intended Audience

This manual is intended for the installer and user of the I/O cards.
The manual assumes basic familiarity with the Infiniband

Related Documentation

Table 2 - Documents List
InfiniBand® Architecture Specification Volume 1 Release 1.2 and Volume 2 release
1.2.1– Infiniband Architecture Specifications Descriptions PCI Express Base 2.0 Specification (1.1 compatible) PCI Local Bus Specification Rev 2.3

Online Resources

• Mellanox Technologies Web pages: http://www.mellanox.com
• Dell Support Web pages: http://support.dell.com

Document Conventions

®
architecture specifications.
These symbols indicate a situation, status, or condition that may cause harm to people or damage to the equipment.
When discussing memory sizes, MB and MBytes are used in this document to mean size in mega bytes. The use of Mb or Mbits (small b) indicates size in mega bits.
Mellanox Technologies
7

1 Overview

This document is a User Manual for the Mellanox ConnectX-2 20 and 40Gb/s InfiniBand / 10GigE Ethernet dual port QSFP I/O cards for the Dell C6100 chassis.
The cards described in this manual have the following main features:
•1μs MPI ping latency
• Selectable 10, 20, or 40Gb/s InfiniBand or 10GigE per port
• CPU offload of transport operations
• End-to-end QoS and congestion control
• Hardware-based I/O virtualization
• PCI Express 2.0 (up to 5GT/s)
• TCP/UDP/IP stateless offload
• Fibre Channel encapsulation (FCoIB or FCoE)

1.1 I/O Card

OverviewRev 1.0
Table 3 - ConnectX-2 I/O Card Details
Ordering Part
Number (OPN)
MCQH29-XDR PCIe Gen2
PCI Express
SERDES
Speed
5.0 GT/s
Transmission
40 Gb/s QDR
IB Data
Rate
InfiniBand
Eth Data
Transmission
Rate
10 Gb/s
RoHS Adapter IC Part Number
R-6 MT25408B0-FCCR-QI
8
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
IL-0JR3P1-74031-980-0001
REV:A00
Made in IL
P/N: 0JR3P1 REV: X1
Made in IL
GUID: 0024E89097FF24DC
MAC: 0002C9011226 FC
Model No: MCQH29-XDR

1.2 Finding the GUID/MAC and Serial Number on the Adapter Cards

All cards have a label on the printed side of the card that has the card serial number, the card MAC for Ethernet protocol, and the card GUID for InfiniBand protocol. VPI Cards have both a MAC and a GUID.
Figure 1: Card Product Labels
Mellanox Technologies
9

2 I/O Card Interfaces

2.1 I/O Interfaces

The ConnectX-2 I/O card is VPI-capable, supporting InfiniBand or Ethernet on either port. Th e following table shows the supported configurations.
Table 4 - VPI Support
I/O Card InterfacesRev 1.0
Figure 2: PCI Connection
Port 1 Port 2 Supported
IB IB supported IB EN supported EN IB not supported EN EN supported

2.1.1 InfiniBand Interface

The ConnectX-2 VPI adapter card is compliant with the InfiniBand Architecture Specification, Release 1.2.1. It has two compliant QSFP InfiniBand ports, with four Tx/Rx pairs of SerDes con-
nected to QSFP connectors.

2.1.2 Ethernet Interface

The ConnectX® -2 VPI adapter card is compliant with the IEEE Std 802.3ae Specification. Each port can be connected to a 10 Gigabit Ethernet switch through the use of QSFP to SFP+ hybrid cables.
10
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
Table 5 - Physical and Logical Link Indications
Figure 3: Front Panel
Port Number LED Name
Port 1 Physical Link - Green
Constant on indicates a good physical link
Blinking indicates a problem with the Physical link
Data Activity - Yellow
Blinking indicates Data Transfer
Constant on indicates no Data Transfer
Port 2 Physical Link - Green
Constant on indicates a good physical link
Blinking indicates a problem with the Physical link
Data Activity - Yellow
Blinking indicates Data Transfer
Constant on indicates no Data Transfer
Physical Connection Data Transfer
Port 1
Port 2

2.2 LED Assignment

2.3 PCI Express Interface

The I/O card attaches to the blade's PCI Express interface through a press fit connector. The PCI Express x8 interface is version 2.0 compliant and compatible with base 1.1 chipsets. The device can be either a master initiating the PCI Express bus operations or a slave responding to PCI bus

2.4 Memory

operations.
The I/O card supports multiple memory devices through the PCI Express, Flash, and I2C compati­ble interfaces.

2.4.1 System Memory

The I/O card utilizes the PCI Express interface to store and access fabric connection information on the system memory.
Mellanox Technologies
11

2.4.2 EEPROM

The I/O card incorporates an EEPROM that is accessible through the I2C-compatible interface. The EEPROM is used for storing the Vital Product Data (VPD). The VPD format adheres to the PCI Local Bus Specification Rev 2.3 VPD definition. The EEPROM capacity is 4Kb.

2.4.3 Flash

The I/O card includes one SPI Flash device accessible via the Flash interface of the MT25408B0 ConnectX-2 device.
There is a jumper on the card that indicates to the device whether an on-board Flash device is to be used. Table 6 provides information on this jumper. See the schematic in Figure 14 on page 23 for the jumper location.
Table 6 - Jumper Configuration
I/O Card InterfacesRev 1.0
Description Option
Flash present/
not present
connection open – Flash present connection shorted – Flash not present
Figure 4: Flash Jumper
Card Default
Configuration
connection open –
Flash present
Comments
Header 1x2

2.5 EEPROM VPD

The I/O card incorporates an EEPROM that is accessible through the I2C-compatible interface. The EEPROM is used for storing the Vital Product Data (VPD) and FRU. The VPD format adheres to the PCI Local Bus specification rev 2.3 VPD definition. The EEPROM capacity is 4Kb.
Table 7 - MCQH29-XDR VPD
Offset (Decimal) Item Value Format Description
0 Large Resource Type ID String Tag (0x02) 0x82 1Length0x12 3 Data "DELL PE C6100
MEZZ IB QDR" 21 Large Resource Type VPD-R Tag (0x10) 0x90 Read Only Area 22 Length 0x43 24 VPD Keyword “PN” Numbers Add in Card Part Number 26 Length 0x6 27 Data “059MP7” 33 VPD Keyword “EC” Alphanumeric Engineering Change Level of the
35 Length 0x3
Alphanumeric Short description / ID
card (rev)
12
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
Table 7 - MCQH29-XDR VPD
Offset (Decimal) Item Value Format Description
36 Data ”A00” 39 VPD Keyword “SN” Alphanumeric Serial Number 41 Length 0x14 42 Data “OO059MP7MM
MMMYMDSSSS
” 62 VPD Keyword “V0” Misc Information 64 Length 0x16 65 Data "DELL PE C6100
MEZZ IB QDR" 87 VPD Keyword “RV” 89 Length 0x1 90 Data Checksum 91 Large Resource Type VPD-W Tag (0x11) 0x91 Read / W rite Area 92 Length 0xA1 94 VPD Keyword “V1” Driver version 96 Length 0x6 97 Data “N/A” Number
103 VPD Keyword “YA” Asset Tag 105 Length 0x20 106 Data “N/A” Alphanumeric 138 VPD Keyword “RW” Remaining read/write area 140 Length 0x72 141 Data Reserved (0x00) 255 Small Resource Type END Tag (0x11) 0x78
256 Mellanox Read Only Mask 0x0....0 Numbers
350 Mellanox Read/Write Mask 0x1...1 Numbers 511 Mellanox Read Only Mask 0x0 Numbers
according to the board label
Mellanox Technologies
13

3 Driver Software and Firmware

3.1 Driver Software

3.1.1 Linux

For Linux, download and install the latest OpenFabrics Enterprise Distribution (OFED) software package available via the Mellanox Web site at:
http://www.mellanox.com => Downloads => InfiniBand/VPI SW /Drivers. Follow the installation
instructions included in the download package.

3.1.2 Windows

For Windows, download and install the latest WinOF for VPI software package available via the Mellanox Web site at:
http://www.mellanox.com => Downloads => InfiniBand/VPI SW/Drivers

3.2 Updating Card Firmware

Driver Software and FirmwareRev 1.0
Each card is shipped with the latest version of qualified firmware at the time of manufacturing. Firmware is updated occasionally, and the most recent firmware can be obtained from
http://www.mellanox.com => Downloads => Firmware.
Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firm- ware Tools (MFT) package. This package is available for download, along with its user manual, from the Mellanox Firmware Tools page. See http://www.mellanox.com => Downloads => Firm­ware Tools.
A firmware binaries table lists a binary file per card. The file name of each such binary is com­posed by combining the firmware name, the firmware release version, and the card part number.
Please contact Mellanox or your assigned Field Application Engineer if you cannot find the firm­ware binary for your adapter card.

3.3 FlexBoot

FlexBoot enables remote boot over Ethernet or InfiniBand using Boot over InfiniBand (BoIB), Boot over Ethernet (BoE), or Boot over iSCSI (Bo-iSCSI). This technology is based on the Pre­boot Execution Environment (PXE) standard specification, and FlexBoot software is based on the open source EtherBoot/gPXE project (see www.etherboot.org). For more information go to
http://www.mellanox.com > Products > InfiniBand/VPI SW/Drivers > FlexBoot.
14
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0

4 I/O Card Installation

4.1 Hardware and Software Requirements

Before installing the VPI I/O card, please make sure that the system meets the hardware and soft­ware requirements listed in Table 8, “Hardware and Software Requirements”.
Table 8 - Hardware and Software Requirements
Requirement Description
Hardware Used with Dell C6100 chassis
Software Operating
Systems/Distributions
Software Stacks Mellanox OpenFabric software package (either MLNX_OFED for Linux or

4.2 Installation Kit

Make sure all of the parts are in the kit before you start the installation. If any parts are damaged or missing, call your supplier immediately.
Refer to the C6100 chassis Manuals
MLNX_WinOF for Microsoft Windows)
Mellanox Technologies
15
The kit includes:
x3
x3
Table 9 - ConnectX® Dual-Port InfiniBand I/O Card Installation Kit
1 I/O Card 1 connector board 3 flathead screws 1 plastic leg 3 panhead screws
Figure 5: Installation Kit Parts
I/O Card InstallationRev 1.0

4.3 Installation Instructions

Remove the server from the chassis.
1. Connect an ESD strap to your wrist and to a valid ESD ground.
2. Push the latch and pull on the handle.
16
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
Push here
Pull handle
Screws holding the faceplate
Screws in top
Figure 6: Removing From the Server
3. Remove the server and place on a work bench.
4. Above the handle are screws holding on the faceplate.
5. Remove these screws and discard.
6. Remove the two screws on the top side of the server and discard.
7. Remove the faceplate.
8. Push the plastic leg onto the board.
Figure 7: Top View
Mellanox Technologies
17
I/O Card InstallationRev 1.0
Install a flathead screw through the server into the metal leg.
Figure 8: Install the Plastic Leg onto the Board
9. Push the Connector board into the card. The connector board must be installed as seen in Figure 9, directed toward the back of the server.
Figure 9: Installing the Connector Board into the HCA Card
10. Put the card into place in the server, catching the cages into the front panel of the server. The metal leg must go inside of the server and line up with the hole in the side of the server. Also push the connector board into the socket in the server.
11. Screw in a flat head screw for the metal leg.
Figure 10: Dell Card Installed
18
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
Screws holding the faceplate
Screws in top
12. Screw in three panhead screws into the front panel.
Figure 11: Front Panel
13. Screw in two flathead screws on the top of the server into the HCA card.
Figure 12: Top View
14. Slide the server in the chassis.

4.4 Safety Warnings

1. Installation Instructions
Read all installation instructions before connecting the equipment to the power source.
Mellanox Technologies
19
2. Over Temperature
This equipment should not be operated in an area with an ambient temperature exceeding the maximum recommended: 55°C (131°F). To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation openings.
3. Lightening – Electrical Hazard
During periods of lightning activity, do not work on the equipment.
4. Installation of Equipment
This equipment should be installed, replaced, or serviced only by trained and qualified personnel.
5. Disposal of Equipment
I/O Card InstallationRev 1.0
Disposal of this equipment should be in accordance to all national laws and regulations.
6. Compliance with Local and National Codes
This equipment should be installed in compliance with local and national elec­trical codes.
20
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0

5 Cables and Modules

These cards support passive copper cables and active optical cables, both direct attach and through a transceiver module, at up to QDR data rates. See www.mellanox.com => Products => Cables for cable type, model, module, and length recommendations.

5.1 Cable Installation

All cables can be inserted or removed with the unit powered on. To insert a cable, press the con­nector into the port receptacle until the connector is firmly seated. The GREEN LED indicator will light when the physical connection is established (that is, when the unit is powered on and a cable is plugged into the port with the other end of the connector plugged into a functioning port). After plugging in a cable, lock the connector using the latching mechanism particular to the cable ven­dor. When a logical connection is made the YELLOW LED will come on. When data is being transferred the yellow led will blink.
Note: When installing cables make sure that the latches engage.
Note: Always install and remove cables by pushing or pulling the cable and connector in a straight line with the card.
Care should be taken not to impede the air exhaust flow through the ventilation holes. Cable lengths should be used which allow for routing horizontally around to the side of the chassis before bending upward or downward in the rack.
To remove a cable, disengage the loc ks and slowly pull the connector away from the port recepta­cle. Both LED indicators will turn off when the cable is unseated.
Cables, especially long copper cables, can weigh a substantial amount. Make sure that the weight of the cable is supported on its own and is not hanging from the adapter card.

5.1.1 Inserting a Cable into the Card

1. Support the weight of the cable before connecting the cable to the card. Do this by using a cable holder or tying the cable to the rack.
2. Determine the correct orientation of the connector to the card before inserting the connector. Do not try and insert the connector up side down. This may damage the card.
3. Insert the connector into the card. Be careful to insert the connector straight into the cage . Do not apply any torque, up or down, to the connector cage in the card.
4. Make sure that the connector locks in place.
Mellanox Technologies
21
Figure 13: Connector Orientation
180
o
Cables and ModulesRev 1.0

5.1.2 Removing a Cable from the Card

1. Pull on the latch release mechanism thereby unlatching the connector and pull the connector out of the cage.
2. Do not apply torque to the connector when removing it from the card.
3. Remove any cable supports that were used to support the cable’s weight.
22
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
J2
J3
J5
J4J6
Q1
Q2
U9
U1
U13
H1
H2
H3
J1
L14
U8
U10
U3
U5 U6 U7
111.90
34.40
59.70
16.60
79.30
10.80
63.90
10.03
57.15
2.60
4.60
I2C interface J2 Flash Jumper J1

Appendix A: Specifications

A.1 Board Mechanical Drawing and Dimensions

The ConnectX-2 I/O card mechanical drawing is depicted in Figure 14.
Figure 14: Mechanical Drawing
J1 is the flash jumper. J2 is the I2C Connector.
Note: All dimensions are in millimeters.
Mellanox Technologies
23
Rev 1.0
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be

A.2 EMC Certification Statements

A.2.1 FCC Statements (USA) Class A Statements:
§ 15.21
Statement Warning! Changes or modifications to this equipment not expressly approved by the party
responsible for compliance (Mellanox Technologies) could void the user's authority to operate the equipment.
§15.105(a)
Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envi­ronment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
A.2.2 EN Statements (Europe)
EN55022 Class A Statement:
A.2.3 ICES Statements (Canada)
Class A Statement:
“This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.”
A.2.4 VCCI Statements (Japan)
Class A Statement:
24
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
(Translation - "This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case the user may be required to take corrective actions.")
A.2.5 KCC Notice (Republic of Korea Only)
The KCC label may be located separately from the other regulatory markings applied to your prod­uct.
Class A devices are for business purposes.
Class A Device
KCC Class A Regulatory Label
If the regulatory label includes the following marking, your device is a Class A product:
Mellanox Technologies
25
Rev 1.0

A.3 Specifications

Table 10 - ConnectX-2 MCQH29-XDR Specifications
Physical Power and Environmental
Size:
79.30mm X 111.90 mm
Voltage:
12V, 3.3V
Air Flow:
QSFP 40Gb/s
Connector:
200LFM @55°C
InfiniBand (Copper and optical) Max power per port 3.5 W.
Typ Power:
Maximum Power:
Temperature:
Protocol Support Regulatory
InfiniBand:
Ethernet:
IBTA v1.2.1, Auto-Negotiation (20Gb/s@5Gt/s) or (10Gb/s@2.5Gt/s)
IEEE Std 802.3ae 10 Gigabit Ethernet IEEE Std 802.3ad Link Aggrega­tion and Failover IEEE Std 802.3x Pause IEEE Std 802.1Q VLAN tags IEEE Std 802.1p Priorities Multicast Jumbo frame support (10KB) 128 MAC/VLAN addresses per port
QoS:
8 Virtual Lanes for InfiniBand 8 Priority Queues for Ethernet
EMC (Emissions):
Safety:
RoHS:
8.74W Passive cables
12.74W Active cables
10.11W Passive cables
14.11 Active cables
0°C to 55°C
US/Canada: cTUVus EU: IEC60950 International: CB
USA: FCC, Class A Canada: ICES, Class A EU: CE Mark (EN55022 Class A, EN50024, EN61000-3-2, EN61000-3-
3) Japan: VCCI, Class A Korea: KCC Class A Australia/ New Zealand: C-Tick Class A
R-6
26
RDMA Support:
Data Rate
SFP+ Ethernet:
QSFP InfiniBand:
PCI Express:
Mellanox Technologies
Yes, All Ports
10 Gb/s
40 Gb/s
2.0 SERDES @ 5.0 GT/s
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
GND Rx2n
GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22 23
24 25 26 27 28 29
30 31
32 33
34 35 36 37
38
Rx1n
Rx2p
Rx1p
GND
GND
GND
GND
GND
GND
Tx2n
Tx1n
Tx2pTx1p
Tx4n
Tx3n
Tx4p
Tx3p
GND
GND
Rx4n
Rx3n
Rx4p
Rx3p
GND
GND
SDA SCL
Vcc Rx
ResetL
ModSelLLPMode
Vcc1
VccTx
IntL
ModPrsL
Table 3- InfiniBand QSFP Connector Pinout
Connector
Pin
Number
Connector
Pin Name
Signal Description
1 GND Ground 2 Tx2n Transmitter Inverted Data Input 3 Tx2p Transmitter Non-Inverted Data Input 4 GND Ground 5 Tx4n Transmitter Inverted Data Input 6 Tx4p Transmitter Non-Inverted Data Input 7 GND Ground 8 ModSelL Module Select
9 ResetL Module Reset 10 Vcc Rx +3.3 V Power supply receiver 11 SCL 2-wire serial interface clock 12 SDA 2-wire serial interface data 13 GND Ground 14 Rx3p Receiver Non-Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rx1p Receiver Non-Inverted Data Output 18 Rx1n Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 3 22 Rx2p Receiver Non-Inverted Data Output 3 23 GND Ground 24 Rx4n Receiver Inverted Data Output 3 25 Rx4p Receiver Non-Inverted Data Output 3 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx +3.3 V Power supply transmitter 30 Vcc 1 +3.3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non-Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Tx1p Transmitter Non-Inverted Data Input 37 Tx1n Transmitter Inverted Data Input 38 GND Ground

Appendix B: QSFP Interface

Mellanox Technologies
27
Rev 1.0
18.35
8.50
Top
ResetL
SDA
SCL
ModSelL
RX3p
TX2n
GND
VccRx
1
2
3
4
5
6
7
8
9
1
0
1
2
3
4
5
6
7
8
9
TX2p
GND
TX4n
TX4p
GND
1
1
1
1
1
1
1
1
1
1
20
GND
GND
GND
RX3n
RX1p
RX1n
30
1
2
3
4
5
6
7
8
9
2
2
2
2
2
2
2
2
2
1
2
3
4
5
6
7
8
3
3
3
3
3
3
3
3
RX4p
GND
GND
GND
RX4n
RX2p
RX2n
TX1n
GND
TX1p
GND
TX3n
TX3p
GND
IntL
ModPrsL
VccTx
Vcc1
LPMode
18.35
8.50
Top
ResetL
SDA
SCL
ModSelL
RX3p
TX2n
GND
VccRx
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
TX2p
GND
TX4n
TX4p
GND
1
1
1
1
1
1
1
1
1
1
20
GND
GND
GND
RX3n
RX1p
RX1n
30
RX4p
GND
GND
GND
RX4n
RX2p
RX2n
TX1n
GND
TX1p
GND
TX3n
TX3p
GND
IntL
ModPrsL
VccTx
Vcc1
LPMode
1
2
3
4
5
6
7
8
3
3
3
3
3
3
3
3
1
2
3
4
5
6
7
8
9
2
2
2
2
2
2
2
2
2
View into Front of Cage
View into Rear of
Connector
Figure 15: QSFP Connector Male and Female Views
28
Mellanox Technologies
ConnectX®-2 Dual Port VPI I/O Card for Dell C6100 Rev 1.0
Appendix C: Avertissements de sécurité d’installa­tion (French)
1. Instructions d’installation
Lisez toutes les instructions d’installation avant de brancher le matériel à la source d’alimentation électrique.
2. Température excessive
Ce matériel ne doit pas fonctionner dans une zone avec une température ambi­ante dépassant le maximum recommandé de 55°C (131°F). Un flux d’air de 200LFM à cette température ambiante maximale est nécessaire. En outre, pour garantir un bon écoulement de l’air, laissez au moins 8 cm (3 pouces) d’espace libre autour des ouvertures de ventilation.
3. Orages – dangers électriques
Pendant un orage, il ne faut pas utiliser le matériel.
4. Installation du matériel
Ce matériel ne doit être installé, remplacé ou entretenu que par du personnel formé et qualifié.
5. Elimination du matériel
L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législ­ations et réglementations nationales en vigueur.
6. Codes électriques locaux et nationaux
Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux.
Mellanox Technologies
29
Rev 1.0

Appendix D: Installation - Sicherheitshinweise (German)

1. Installationsanleitungen
Lesen Sie alle Installationsanleitungen, bevor Sie das Gerät an die Stromver­sorgung anschließen.
2. Übertemperatur
Dieses Gerät sollte nicht in einem Bereich mit einer Umgebungstemperatur über der maximal empfohlenen Temperatur von 55°C (131°F) betrieben werden. Außerdem sollten mindestens 8 cm (3 in.) Freiraum um die Belüf­tungsöffnungen sein, um einen einwandfreien Luftstrom zu gewährleisten.
3. Bei Gewitter - Elektrische Gefahr
Arbeiten Sie während eines Gewitters und Blitzschlag nicht am Gerät.
4. Geräteinstallation
Diese Gerät sollte nur von geschultem und qualifiziertem Personal installiert, ausgetauscht oder gewartet werden.
5. Geräteentsorgung
Die Entsorgung dieses Geräts sollte unter Beachtung aller nationalen Gesetze Bestimmungen erfolgen.
6. Regionale und nationale elektrische Bestimmungen
Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden.
30
Mellanox Technologies
Loading...