DIETRISOL
EN |
Solar domestic hot water tanks
TRIO DT 250 - TRIO DT 350
User Guide
M000854
300028005-001-03
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.1 Symbols and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.4 Compliance of design and manufacture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.5 Electrical compliance / Marking 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2 Safety instructions and recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.1 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.2 Main parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4 Setting the DHW calorifier outlet temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4.1 Programming and setting the electrical back-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4.2 Setting the thermostatic mixing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5 Diemasol B solar regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.1 General description of how the unit operates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 5.2 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 5.3 Adjustment keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 5.4 LED message code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 5.5 Measured values and adjustment parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6 Checking and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
6.1 Solar installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.2 Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.2.1 Magnesium anodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.2.2 Safety valve or safety unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.2.3 Descaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.2.4 Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.2.5 Vent device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 6.3 Solar circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Warranty certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
2 |
TRIO DT 250 - TRIO DT 350 |
17/10/12 - 300028005-001-03 |
|
In these instructions, various markings and pictograms are used to draw your attention to particular information. In so doing, De Dietrich Thermique S.A.S wishes to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
RiskDangerof a dangerous situation causing serious physical injury.
Warning
Risk of a dangerous situation causing slight physical injury.
RiskCautionof material damage.
Specific information.
ZReference
Refer to another manual or other pages in this instruction manual.
`DHW: Domestic hot water.
Congratulations on choosing a De Dietrich product, a product of quality. We strongly recommend that you read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that you will not be disappointed and that it will satisfy all of your expectations.
Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with 1 marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
`Failure to abide by the instructions on using the appliance.
`Faulty or insufficient maintenance of the appliance.
`Failure to abide by the instructions on installing the appliance.
The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:
`Read and follow the instructions given in the manuals provided with the appliance.
`Carry out installation in compliance with the prevailing legislation and standards.
`Perform the initial start up and carry out any checks necessary.
`Explain the installation to the user.
`If a maintenance is necessary, warn the user of the obligation to check the appliance and maintain it in good working order.
`Give all the instruction manuals to the user.
To ensure the optimum operation of your appliance, we strongly recommend that you abide by the following instructions:
`Read and follow the instructions given in the manuals provided with the appliance.
`Call on qualified professionals to carry out installation and initial start up.
`Get your installer to explain your installation to you.
`Have the required checks and services done.
`Keep the instruction manuals in good condition close to the appliance.
This product conforms to the requirements of european directive 97 / 23 / EC, article 3, paragraph 3, on pressure equipment.
|
|
3 |
|
17/10/12 - 300028005-001-03 |
TRIO DT 250 - TRIO DT 350 |
||
|
1.2.5 Electrical compliance / Marking 1
This product complies to the requirements to the european directives |
Reference Standard: EN 60.335.1. |
|
and following standards: |
• 2004/108/EC Electromagnetic Compatibility Directive |
|
• 2006/95/EC Low Voltage Directive |
||
Reference Standards: EN 50.081.1 / EN 50.082.1 / EN 55.014. |
Any work on the installation must be done by a qualified professional in compliance with the codes of practice and according to the instructions provided.
Have the installation regularly serviced to guarantee that it operates correctly over time.
It is essential to check the magnesium anode in the DHW tank and the installation and heat transporting fluid pressure every two years.
Never cut the power to the solar control system, even during extended absences. The control system protects the installation against overheating in summer when it is running.
During extended absences, we recommend lowering the set point temperature in the solar DHW calorifier to 50°C. When the user is present, the set point must be set to 60°C.
Never drain the installation. Do not replace or add water or solar fluid to the installation. These actions must be carried out by a qualified technician.
Do not modify the control system parameters unless fully conversant with them.
4 |
TRIO DT 250 - TRIO DT 350 |
17/10/12 - 300028005-001-03 |
|
3 |
Technical description |
|
|
|
|
|
|
|
|
|
|
|
|
3.1 |
Technical specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DIETRISOL |
DIETRISOL |
|
|
|
|
|
TRIO DT 250 |
TRIO DT 350 |
|
Maximum operating temperature |
Solar exchangers |
°C |
120 |
120 |
|
|
Boiler heat exchanger |
°C |
90 |
90 |
|
||
|
|
tank |
°C |
90 |
90 |
|
Maximum operating pressure |
|
bar |
7 |
10 |
|
|
Maximum operating pressure in accordance with W/TPW (1) |
|
bar |
6 |
6 |
|
|
Water content |
Solar exchangers |
litres |
9 |
8.1 |
|
|
Boiler heat exchanger |
litres |
4.3 |
4.9 |
|
||
|
|
tank |
litres |
250 |
350 |
|
|
|
Upper solar heat exchanger |
m2 |
0.48 |
0.48 |
|
Surface area |
Lower solar heat exchanger |
m2 |
0.86 |
0.96 |
|
|
|
|
Boiler heat exchanger |
m2 |
0.64 |
0.72 |
|
Operation with boiler back-up |
Top up volume |
litres |
105 |
127 |
|
|
Solar volume |
litres |
145 |
223 |
|
||
|
|
Power exchanged (2) (3) |
kW |
21 |
23 |
|
|
|
Top up volume |
litres |
130 |
160 |
|
|
|
Solar volume |
litres |
120 |
190 |
|
|
|
Output of the electrical back-up |
kW |
2.4 |
3 |
|
|
|
Back-up volume heating time (from 15 |
h |
2h50 |
2h50 |
|
|
|
to 60°C) |
||||
Operation with electrical back-up |
|
|
|
|
||
Vecs 40 (5) (6) |
|
|
|
|
||
|
|
Domestic hot water storage |
litres |
355 |
420 |
|
|
|
temperature: 55 °C |
|
|
|
|
|
|
Vecs40 (5) (6) |
|
|
|
|
|
|
Domestic hot water storage |
litres |
385 |
450 |
|
|
|
temperature: 60 °C |
|
|
|
|
Continuous output ∆T = 35 K (2) (3) |
|
l/h |
515 |
565 |
|
|
|
|
|
|
|
|
|
Flow rate for 10 minutes where ∆T = 30 K (on make-up volume) (2) |
|
l/10 mm |
190 |
230 |
|
|
(4) |
|
|
|
|||
|
|
|
|
|
|
|
Maintenance consumption |
|
kWh/24h |
- |
2.7 |
|
|
Cooling constant Cr |
|
Wh/lKj |
0.22 |
0.19 |
|
(1)Swiss Directives
(2)Domestic cold water input at 10°C - Primary inlet temperature at 80 °C Values measured with a wall-mounted boiler
(3)Domestic hot water temperature: 45 °C
(4)Domestic hot water temperature: 40 °C
(5)Domestic cold water inlet 15 °C
(6)Values measured only on the back-up volume Domestic hot water load setting: 60 °C
|
|
5 |
|
17/10/12 - 300028005-001-03 |
TRIO DT 250 - TRIO DT 350 |
||
|
Composition of the NF CESI DIETRISOL TRIO solar systems packages (for France only)
Check the composition of the CESI solar system, which complies with the requirements of the NF CESI mark, using the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.
A system is complete and functional according to the NF CESI mark if all system references appear on the invoice.
The system is composed of the following elements:
•A collector field with 1 or 2 solar collectors.
•A solar domestic hot water tank to which a solar station incorporating a heating pump, an expansion vessel and a Diemasol A control system is to be mounted.
•The solar fluid that protects the installation from frost and
corrosion.
The system is delivered to the installer in two units: a roof pack containing the collectors, their mounting system and the hydraulic connections on the one hand, and a cellar pack containing the calorifier, the system components and the solar fluid on the other hand.
CESI System |
|
Array of collectors |
|
|
|
Domestic hot water production |
|
Solar fluid |
||
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
Type of mounting |
package / |
|
DHW calorifier type |
package / |
Volume |
Back-up |
package / |
|
|
panels |
Reference |
|
Reference |
(litres) |
type |
Reference |
|||
|
|
|
|
|
||||||
DIETRISOL TRIO |
1 |
On roof |
ER 234 |
|
DT 250 |
|
EC 340 |
250 |
Mixed |
EG 100 |
250-3 |
100019328 |
|
|
100007796 |
89807792 |
|||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
On roof |
ER 432 |
|
|
|
|
|
|
|
|
2 |
(mechanical tiles - |
|
|
|
|
|
|
|
|
|
100019695 |
|
|
|
|
|
|
|
||
|
|
Universal hook) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 433 |
|
|
|
|
|
|
|
|
(Slates) |
100019696 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
On roof |
ER 434 |
|
|
|
|
|
|
|
|
2 |
(mechanical tiles - On |
|
|
|
|
|
|
|
|
DIETRISOL TRIO |
100019697 |
|
|
|
EC 340 |
|
|
EG 100 |
||
|
rafter) |
|
DT 250 |
|
250 |
Mixed |
||||
|
|
|
|
|||||||
D 250-4 |
|
|
|
|
|
100007796 |
89807792 |
|||
|
Roof-integral |
ER 442 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
(> 20°) |
100019705 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
(mechanical tiles) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 446 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
(> 20°) |
100019709 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
(Slates / Flat tile) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
EC 521 |
|
|
|
|
|
|
|
|
(Delivered vertically) |
100007869 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
EC 580 |
|
|
|
|
|
|
|
|
(Delivered horizontally) |
100009302 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
DIETRISOL TRIO |
|
Roof-integral |
EC 531 |
|
|
|
EC 340 |
|
|
EG 100 |
2 |
Installation |
|
DT 250 |
|
250 |
Mixed |
||||
250-5 |
(> 20°) |
100007879 |
|
|
|
100007796 |
|
|
89807792 |
|
|
|
(Delivered vertically) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
EC 586 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
(> 20°) |
100009308 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
(Delivered horizontally) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
TRIO DT 250 - TRIO DT 350 |
17/10/12 - 300028005-001-03 |
|
CESI System |
|
|
Array of collectors |
|
|
|
Domestic hot water production |
|
|
Solar fluid |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
Type of mounting |
package / |
|
DHW calorifier type |
package / |
Volume |
Back-up |
|
package / |
|
|
|
panels |
Reference |
|
Reference |
(litres) |
type |
|
Reference |
|||
|
|
|
|
|
|
|
||||||
|
|
|
On roof |
ER 432 |
|
|
|
|
|
|
|
|
|
|
2 |
(mechanical tiles - |
|
|
|
|
|
|
|
|
|
|
|
100019695 |
|
|
|
|
|
|
|
|
||
|
|
|
Universal hook) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 433 |
|
|
|
|
|
|
|
|
|
|
(Slates) |
100019696 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
On roof |
ER 434 |
|
|
|
|
|
|
|
|
|
|
2 |
(mechanical tiles - On |
|
|
|
|
|
|
|
|
|
DIETRISOL TRIO |
100019697 |
|
|
|
EC 339 |
|
|
|
EG 100 |
|||
|
rafter) |
|
DT 350 |
|
350 |
Mixed |
|
|||||
|
|
|
|
|
||||||||
D 350-4 |
|
|
|
|
|
100007795 |
89807792 |
|||||
|
Roof-integral |
ER 442 |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
|
|
(> 20°) |
100019705 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
(mechanical tiles) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 446 |
|
|
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
|
|
(> 20°) |
100019709 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
(Slates / Flat tile) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
EC 521 |
|
|
|
|
|
|
|
|
|
|
(Delivered vertically) |
100007869 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
EC 580 |
|
|
|
|
|
|
|
|
|
|
(Delivered horizontally) |
100009302 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
DIETRISOL TRIO |
|
Roof-integral |
EC 531 |
|
|
|
EC 339 |
|
|
|
EG 100 |
|
2 |
Installation |
|
DT 350 |
|
350 |
Mixed |
|
|||||
350-5 |
|
(> 20°) |
100007879 |
|
|
|
100007795 |
|
|
89807792 |
||
|
|
|
(Delivered vertically) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
EC 586 |
|
|
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
|
|
(> 20°) |
100009308 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
(Delivered horizontally) |
|
|
|
|
|
|
|
|
|
ZSee chapter: NF CESI data sheet.
|
|
7 |
|
17/10/12 - 300028005-001-03 |
TRIO DT 250 - TRIO DT 350 |
||
|
Dietrisol TRIO DT ... is a high performance solar DHW tank/calorifier designed to be connected to Dietrisol NEO or POWER solar collectors and an De Dietrich central heating boiler.
It is designed in such a way as to be able to cope with a solar collector surface area of up to 4.5 m2 (DT 250) and 6.5 m2 (DT 350) under the conditions set out in the chapter "Hydraulic Connection Primary Solar Circuit".
tank
The high quality steel tank is lined with food standard quality vitrified enamel, which protects it from corrosion and preserves all the qualities of the domestic water.
The Dietrisol TRIO DT ... tank is fitted with 2 heat exchangers per zone for solar heating and one heat exchanger for supplementary heating by means of a fuel oil or gas boiler.
1 |
2 |
|
3 |
||
4 |
||
|
||
5 |
6 |
|
12 |
||
|
||
7 |
|
|
8 |
13 |
|
|
9 |
14 |
11 |
M001003 |
10 |
|
1Pressure gauge - Primary solar circuit
2Safety control unit for the solar circuit (6 bar)
3Blue thermometer (tank solar heat exchangers outlet)
4Red thermometer (tank solar heat exchangers inlet)
5Primary solar circuit pump
6Manual bleed degasser
72-position 3-way directional valve
8Diemasol B regulator
98 l/6 bar expansion vessel, 2-bar pre-load
10Automatic connection for expansion vessel
11Primary solar circuit filling and draining device
12Magnesium anode
13Electric heating resistance
14Magnesium anode
Protection against corrosion
The tank is also protected from corrosion by two magnesium anodes which must be inspected every 2 years and replaced if necessary.
Heat exchanger
The thermal exchanger welded into the tank is made of smooth piping, the inside of which, which is in contact with the domestic water, is enamelled.
Insulation
The tank is strongly insulated with high strength rigid polyurethane foam with no chlorofluorocarbons (CFC), 50 mm thick to minimise heat loss.
Casing
The outside casing is made of painted steel sheeting. The top and side covers are made of ABS.
Solar station
The solar heating pump unit comprises the solar circuit safety unit, a pressure and temperature gauge and a flowmeter to visualise circulation of the solar fluid between the panels and the DHW tank. An expansion vessel is connected to the solar unit; it is used to compensate for the expansion of the solar fluid in which the temperature varies between 0 and 150°C.
Diemasol B regulator
The control system is the solar system's brain; it makes the solar heating pump run at variable speeds according to the difference in temperature between the bottom of the DHW tank and the solar panels. The control system manages the set point temperature (temperature to be attained in the DHW tank), overheating and nighttime cooling. The control system also displays the various operating modes, the temperatures in the collectors and in the bottom of the DHW tank, as well as signalling any malfunctions.
8 |
TRIO DT 250 - TRIO DT 350 |
17/10/12 - 300028005-001-03 |
|