DeDietrich ELIDENS, DTG 1300 Eco.NOx Plus / V130, DTG 130 Eco.NOx Plus, DTGE 130 Eco.NOx Plus User Manual

Page 1
DTG 1300 Eco.NOx Plus / V130 DTG(E) 130 Eco.NOx Plus
Gas fired condensing boiler
ELIDENS
User Guide
8538N045-B
300002784-001-F
Page 2
2
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
.
Contents
1 Used symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.1 Aeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.1.1 Chimney versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.1.2 Forced flue versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.3 Adapting to another gas type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.1 Boilers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.2 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4 Energy-saving boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
5 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6 Stopping the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
8 Alarm messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Page 3
3
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
1. Used symbols
1 Used symbols
Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment
Specific information Information must be kept in mind to maintain comfort
Z
Reference Refer to another manual or other pages in this instruction manual
DHW: Domestic hot water
Congratulations on your choice of a high quality product. We strongly advise you to read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that it will be entirely to your satisfaction and will meet with all of your expectations.
2 Important recommendations
For a proper operating of the boiler, follow carefully the instructions.
Any intervention on the appliance and heating equipment must be carried out by a qualified technician.
The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter).
Check that the appliance is properly set for the type of gas used.
Keep to the polarity shown on the terminals: phase (L), neutral (N) and earth
4
.
Check the seal on the gas and water pipe connections.
Check regularly that the installation contains water and is pressurised.
To guarantee protection against the corrosion of domestic hot water calorifiers fitted with a titanium anode (Titan Active System® protection system), always leave the control panel switched on. To switch off the heating or the domestic hot water, use the Summer or Antifreeze mode (Vacation).
Page 4
4
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
2. Important recommendations
2.1 Aeration
2.1.1 Chimney versions
Do not obstruct the air inlets in the room (even partially).
France: the cross section of the aeration vent, which is compulsory
in the boiler room in which the boiler is installed, must comply with the DTU 61.1 (P 45 204) standard and, in particular, with the instruction on boiler room layout (Book 1764 April 1982).
Belgium:the cross-section of the aeration vents, which are compulsory in the room in which the boiler is installed, must comply with the NBN D51-003 standard.
Germany: the cross section of the ventiliation vents, which are compulsory in the room in which the boiler is installed, must comply with the VDI 2050 form 1 standard and with other prevailing regulations.
Other countries: the cross section of the aeration inlet, which is compulsory in the premises in which the boiler is installed, must comply with the standards in force in the country.
2.1.2 Forced flue versions
It is not necessary to provide ventilation of the premises in which the boiler is installed. Ventilation is required if a mechanical connection to the gas exists.
2.2 Maintenance
- The servicing and cleaning of the boiler and the sweeping of the flue gas pipe and the bleed pot must be done at least once a year by a qualified professional. We recommend taking out a maintenance contract.
- Regularly check the level of water in the system and top up if required, taking care that cold water is not added suddenly into the boiler when it is hot. If this operation is repeated several times per season, locate the leak and repair it.
Do not drain the installation, except in cases of absolute necessity. For example: Several months' absence with the risk of ice in the building.
2.3 Adapting to another gas type
Belgium:
The operations required to switch from one gas to another must be carried out by a SERV'elite technician.
Other countries:
The operations required to switch from one gas to another must be carried out by your fitter.
Page 5
5
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
3. Description
3 Description
3.1 Boilers
The models presented are marketed in the various countries according to the countries' specific sales programme.
Package HE1 - HE2
8538N075
1 Condensing boiler module
2 Electronic manometer
3 Automatic air vent
4 Expansion vessel (12 litres)
5 Siphon
6 Modulating pump
7 Safety valve (3 bar)
8 Inverter valve
9 Stop cock
10 Domestic hot water safety valve 7 bar
11 Non-return valve
12 Disconnector
13 Funnel
14 Domestic hot water tank
15 Exchanger
16 Domestic recirculation
17 Cold water inlet
18 Heating return
19 Condensates discharge
20 Heating outlet
21 Domestic hot water
22 Gas
Page 6
6
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
3. Description
Package HE3 - HE4 - HE13 - HE14
8538N100
1 Condensing boiler module
2 Electronic manometer
3 Automatic air vent
4 Expansion vessel (12 litres)
5 Siphon
6 Modulating pump
7 Safety valve (3 bar)
8 Inverter valve
9 Stop cock
10 Domestic hot water safety valve 7 bar
11 Non-return valve
12 Disconnector
13 Funnel
14 Domestic hot water tank
15 Exchanger
16 Domestic recirculation
17 Cold water inlet
18 Heating return
19 Condensates discharge
20 Heating outlet
21 Domestic hot water
22 Gas
23 Fire prevention valve
Page 7
7
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
3. Description
Package GN1 - GN2
Package GN3 - GN4
1 Condensing boiler module (15 kW - 25 kW)
2 Electronic manometer
3 Siphon
4 Heating return
5 Condensates discharge
6 Heating outlet
7 Gas
1 Condensing boiler module (15 kW - 25 kW)
2 Electronic manometer
3 Automatic air vent
4 Expansion vessel (12 litres)
5 Siphon
6 Modulating pump
7 Safety valve (3 bar)
8 Stop cock
9 Non-return valve
10 Filling valve
11 Heating return
12 Condensates discharge
13 Heating outlet
14 Gas
15 Gas valve
Page 8
8
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
3. Description
3.2 Control panel
Electromechanical components
4
A M P
C000142_06
13
0 2 4 6 81012141618202224
A
2
4
SUNDAY
-04
1 Main ON/OFF switch
2
On light / Alarm Red LED lit: Burner in safety condition Flashing red Led: abnormal operation
3 Safety control box reset button
4
Timed circuit breaker (4 A) A second electrical safety device can be found on the card which is accessible when the hoods are removed. This is a fuse: F1 4 amperes, delayed action
Page 9
9
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
3. Description
Display
024681012141618202224
A
bar
3 4 5 6 7
91011
8
2 1
BC
SUNDAY
1 Text and numerical display
2 Graphic display bar for the programme in circuit A, B or C
3 Light area: Reduced temperature heating period or tank load disabled
4 Dark area: Comfort temperature heating period or tank load enabled
5 Flashing cursor showing the current time
6 Number display (current time, adjusted values, parameters, etc.)
7
Active programme display, P1, P2, P3, P4 or
E: Summer mode activated
8 The arrows flash when setting values can be modified using the + and - keys
9 Circuit operation symbols
>
=
:
A, B, C
Opening the 3-way valve
Closing the 3-way valve
Displayed circuit pump on
Name of the circuit displayed
10 Symbol displayed above the active operating mode
11 Symbols indicating that the following inputs/outputs are active
D Y X  #
U T
Burner on
Burner on with an increase in the output level
Burner on with a reduction in the output level
DHW load pump on
Summer mode
Display of the water pressure in the boiler Insufficient pressure: add water (0 - 0.5 bar)
Addition of water recommended (0.5 - 1 bar) Pressure correct (1 - 2 bar) Too much pressure (> 2 bar)
Page 10
10
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
3. Description
Keys accessible when the flap is closed
0 2 4 6 81012141618202224
A
C000142_02
SUNDAY
-04
Setting the temperatures
2%
Comfort temperature
2$
Reduced temperature
2
Domestic hot water temperature
/
Is used to adjust the selected temperature
Operating mode selection keys
AUTO
Heating according to the time programme
%
Forced Comfort mode:
- until midnight if flashes
- all the time if is steady
$
Forced Low mode:
- until midnight if flashes
- all the time if is steady
.
Antifreeze mode
Tank load enabled mode:
- until midnight if flashes
- all the time if is steady
Page 11
11
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
3. Description
Keys accessible when the flap is open
A
024681012141618202224
A
STANDARD
C000142_03
SUNDAY
-04
#
Manual "Summer" shutdown key The heating is switched off and DHW production is ensured. The symbols # and Su are displayed.
R
"Standard" programme key Reset of all time programmes
K
Fitter settings access key
Key for access to setting and measurements
J
Page scrolling
I
Line scrolling
H
Back to the title or the previous line
Programming keys
%O
Enter (per 1/2 hour) the comfort temperature period or tank load enabled (dark area)
$P
Enter (per 1/2 hour) the reduced temperature period or tank load disabled (light area)
S
Return key
A.B.C. Circuit display selection key
PROG Active heating programme selection key (P1, P2, P3 or P4)
Page 12
12
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
4. Energy-saving boiler
4 Energy-saving boiler
This boiler handles all the functionalities that one may expect of a condensing boiler. Cutting edge technologies have been used not only in its exceptionally economic design in terms of finance and energy, and therefore also of environmental protection, but have also been applied to provide maximum comfort: heating for the whole house, hot water, incredibly simple to use and trouble-free operation thanks to its reduced noise level.
The floor-standing gas condensing boiler is not content with using the heat contained in the exhaust gases (perceptible) but also takes advantage of latent heat (hidden). This energy is extracted from the steam produced during the combustion process and is not exploited by conventional boilers. The exhaust gases are here cooled in the boiler in such a way that the steam condenses and the additional heat from the exhaust gases is introduced into the heating system. A special algorithm (Active Condens System) optimises the flow and return temperature to the boiler during the tank loading phase, thanks to a modulation of the circulating pump activated by rotation. The boiler's efficiency is thus always optimum and the drinking water draw-off capacity is increased.
The boiler meets the requirements of the German Decree on energy savings (Energie-EinsparVerordnung, EnEV) and offers truly exceptional value for money.
Page 13
13
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
5. Start-up
5 Start-up
Initial commissioning must be done by a qualified professional.
1. Check the water pressure in the installation several times a year.
Top up with more water if necessary.
2. Open the gas valve.
3. Control panel:
Set the On/Off switch to
8
.
Create a requirement for heat.
6 Stopping the boiler
Set the On/Off switch to 7.
On the Off position 7, the domestic hot water calorifier fitted with a titanium anode is not protected against corrosion.
Precautions to take if there is a danger of frost
Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water freezing. If this cannot be done, drain the system completely. In all cases, consult the fitter.
Domestic hot water circuit:
Drain the domestic water tank and pipes.
Precautions to take in the event of prolonged shutdown (one year or more)
- Close the gas valve
- The boiler and the chimney must be swept carefully.
- Close the door of the boiler to prevent the internal circulation of air.
7 Troubleshooting
Checks to make before calling your fitter:
The burner is not working:
` It is cold.
- If using a remote control (CDI2 or FM52), check that it is set according to the instructions.
` It is cold. There is no domestic hot water.
- Check the temperature and time programme settings.
- Note the alarm message.
- Press button
.
- Release the button. The boiler restarts.
- In the event of problems, see Alarm messages.
The burner is operating but the radiators are cold:
` Air and water noise in the radiators
- Bleed the radiators.
- Top up the heating circuit with water.
- If it is often necessary to top up the installation with water, contact your fitter.
- If the problem persists, consult your fitter.
` The burner is operating but the radiators are cold
- If the problem persists, consult your fitter.
Hot water takes a very long time to reach certain draw-off points and not others
This is due to the length of the hot water pipes between the draw-off points and the boiler. The greater the length, the longer the time necessary for the hot water to replace the colder water in the pipes.
When you inform your fitter of an error, tell him:
- Product type
- Year of manufacture
- Serial number
- Type of gas used
This information can be found on the rating plate affixed to the underside of the domestic hot water tank.
- Indicate the fault reading.
Page 14
14
DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F
8. Alarm messages
8 Alarm messages
Faults
In the event of a fault, the display may show the following messages. Contact your fitter.
Message Probable causes Solution
BURNER FAILURE
Igniter fault
Reset the safety control box. Contact your fitter.
Ionization error
Gas valve defective
No gas or presence of air in the pipe
CVI8 FAILURE
Incorrect positioning of the electrode
Ignition cable or electrode connector defective
Internal safety control box fault
CVI9 FAILURE
Electrical impulse fault on the gas valve control
Poor contact between the safety control box and the valve
Gas valve control in the safety control box is defective
CVI10-22 FAILURE Internal safety control box fault
CVI COM.FAULT
Communication error between DIEMATIC and safety control box
MANOMETRE FAIL Fault on the water pressure sensor
Switch off and reignite the boiler to restart heating for a period of 72 hours. (The
message continues to be displayed.) Contact your fitter.
ROOM S.A FAIL. ROOM S.B FAIL. ROOM S.C FAIL. OUTL S.B FAIL. OUTL S.C FAIL. OUTSI. S.FAIL. SOLAR S. FAIL FAN FAILURE SWIM.P. S.FAIL
Fault in the corresponding sensor
Contact your fitter.
ST.TANK S.FAIL
The hot water storage tank reheating operation is no longer assured
BOILER S.FAIL. Boiler sensor defective
DHW S. FAILURE Domestic hot water sensor defective
TA-S SHORT-CIR There is a short circuit in the TAS
TA-S DISCONNEC The TAS is in open circuit
TA-S FAILURE Internal problem
Page 15
15
10/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130
8. Alarm messages
Warranty
You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained. Your fitter and our customer support network are at your disposal at all times.
Warranty terms
Starting from the purchase date shown on the original fitter's invoice, your appliance has a contractual guarantee against any manufacturing defect.
The length of the guarantee is mentioned in the price catalogue. The manufacturer is not liable for any improper use of the appliance
or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter). In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following:
- applicable local laws and regulations
- specific requirements relating to the installation, such as national and/or local regulations
- the manufacturer's instructions, in particular those relating to the regular maintenance of the unit
- the rules of the profession
The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs. The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel. Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled.
France
The preceding dispositions are not exclusive of benefits for the purchaser of the legal guarantee as stated in Civil Code articles 1641 to 1648.
Poland
Warranty conditions are included in the warranty card.
Switzerland
The application of the warranty is subject to the terms and conditions of sale, delivery and warranty of the company marketing our products.
Belgium
The preceding dispositions about the contractual guarantee are not exclusive of profit if the need arises for the purchaser in Belgium of the applicable legal dispositions on hidden defects.
Italy
The duration of our warranty is shown on the certificate delivered with the appliance.
Our liability as manufacturer may not be invoked in respect of incorrect use of the appliance, incorrect or insufficient maintenance thereof, or incorrect installation of the appliance (you must therefore ensure that installation and maintenance operations are carried out respectively by a qualified professional and by an after sales service company).
The legislation laid down by European Directive 99/44/EEC, transposed by Legislative Decree No. 24 of 2 February 2002 published in O.J. No. 57 of 8 March 2002, continues to apply.
Russia
The foregoing provisions in no way affect the rights of the consumer, which are guaranteed by the legislation of the Russian Federation as regards hidden defects.
The terms and conditions of warranty and the terms and conditions of application of the warranty are indicated on the warranty form.
The warranty shall not apply as regards the replacement or repair of wearing parts under normal use. Such parts include thermocouples, injection nozzles, flame control and ignition systems, fuses and gaskets.
Turkey
Due to the laws and regulations the product life for this product is 10 years. During that time the producer and/or the distributor has to provide after sales services and spare parts.
Other countries
The above provisions do not restrict the benefit of the legal laws regarding hidden defects applicable in the buyer's country.
Page 16
© Copyright
All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
Subject to alterations.
10/11/2009
DE DIETRICH THERMIQUE 57, rue de la Gare F- 67580 MERTZWILLER - BP 30
DE DIETRICH THERMIQUE S.A.S.
www.dedietrich-thermique.fr
FR
Direction des Vente s France
57, rue de la Gare
F- 67580 MERTZWILLER
+33 (0)3 88 80 27 00 +33 (0)3 88 80 27 99
DE DIETRICH REMEHA GmbH
www.dedietrich-remeha.de
VAN MARCKE
www.vanmarcke.be
WALTER MEIER (Klima Schweiz) AG
www.waltermeier.com
DE
BE
CH
NEUBERG S.A.
www.dedietrich-heating.com
LU
DE DIETRICH
RU
Rheiner Strasse 151
D- 48282 EMSDETTEN
+49 (0)25 72 / 23-5
+49 (0)25 72 / 23-102
info@dedietrich.de
Weggevoerdenlaan 5
B- 8500 KORTRIJK
+32 (0)56/23 75 11
Bahnstrasse 24
CH-8603 SCHWERZENBACH
+41 (0) 44 806 44 24
+41 (0) 44 806 44 25
39 rue Jacques Stas
L- 2010 LUXEMBOURG
+352 (0)2 401 401
ch.klima@waltermeier.com
DE DIETRICH
www.dedietrich-heating.com
CN
Room 512, Tower A, Kelun Building 12A Guanghua Rd, Chaoyang District
C-100020 BEIJING +86 (0)106.581.4017 +86 (0)106.581.4018 +86 (0)106.581.7056 +86 (0)106.581.4019
contactBJ@dedietrich.com.cn
Serviceline +41 (0)8 00 846 846
WALTER MEIER (Climat Suisse) SA
www.waltermeier.com
Z.I. de la Veyre B, St-Légier
CH-1800 VEVEY 1 +41 (0) 21 943 02 22
+41 (0) 21 943 02 33
ch.climat@waltermeier.com
Serviceline +41 (0)8 00 846 846
ÖAG AG
www.oeag.at
AT
Schemmerlstrasse 66-70
A-1110 WIEN
+43 (0)50406 - 61624
+43 (0)50406 - 61569
dedietrich@oeag.at
AD001NU-AC
www.dedietrich-otoplenie.ru
ул. Гиля ровск ого, д. 8
129090 г. Москва
+7 495 988-43-04 +7 495 988-43-04