DATEL ACA5-20PC-9-DC3-RL, ACA5-20PC-9-DC3-RH, ACA5-20PC-9-DC3-GS, ACA5-20PC-9-DC2-RL, ACA5-20PC-9-DC1-RL Datasheet

...
0 (0)
DATEL ACA5-20PC-9-DC3-RL, ACA5-20PC-9-DC3-RH, ACA5-20PC-9-DC3-GS, ACA5-20PC-9-DC2-RL, ACA5-20PC-9-DC1-RL Datasheet

®

®

Order on-line

at www.datel.com

E156931

Features

Scales and displays the output of 50:5A to 2000:5A current transformers

14 ranges (0-50 Amp to 0-2000 Amp)

3 LED options, 6 power options, 112 models

Functionally complete:

On-board 5A current transformers

Scaling/interface circuitry

Precision A/D converters

Bright red or green LED displays

Subminiature, 1.38" x 0.88" package

Easy-to-read, 0.37"/9.4mm digits

AC powered models: 120Vac @ 400Hz, 120/220/277Vac @ 50/60Hz

AC models can be "self-powered"

DC powered models: +5V, +5-40V, +36-75V

2000V isolation; UL/CSA recognized

Digital replacements for analog ammeters

ACA5-20PC Series

Digital-Readout

LED-Display

50-2000A AC Ammeters

ACA5-20PC Series AC Ammeters are designed to scale and digitally display the output of standard, 5A-output current transformers (50:5A, 500:5A, 1000:5A, etc.). Simply pass the secondary/output wires of the "primary" CT through the ACA5-20PC's on-board CT, apply power to the meter, and you're instantly measuring ac currents over one of 14 ranges from 0-50A (with 100mA resolution) to 0-2000A (with 1A resolution). Because they accept outputs from previously installed high-current CT's, ACA5-20PC's can instantly bring modern digital precision to older ac ammeters.

The functionally completeACA5-20PC ammeters incorporate scaling/interface circuitry to mate the on-board CT to a precision (3½ digit) A/D converter. The A/D's output directly drives the meters' large (0.37"/9.4mm digit height), easy-to-read, LED displays. All models employ auto-zero circuits, precision bandgap references, and super stable metal-film resistors for unsurpassed accuracy (±0.15%FS) and stability.

ACA5-20PC meters are either ac (120/220/277Vac @ 50/60Hz or 120Vac @ 400Hz) or dc (+5V, +5-40V, or +36-75V) powered.AC models can be powered by the same ac supply whose current they are monitoring. All ACA5-20PC's provide 2000Vdc isolation between the measured ac current and their power supply, and all models are UL/CSA recognized.

Each meter is housed in a subminiature, 1.38" x 0.88", epoxy-encapsulated package whose behind-the-panel installation depth is 2 inches. Display color options include standard red, high-intensity red, and standard green. Each meter is supplied with a plastic bezel assembly with sealing gaskets (DATEL DMS-BZL4).

CAL.

+

3½ DIGIT

A/D CONVERTER

+V

–V

LED DISPLAY

PRECISION

FULL-WAVE

RECTIFIER

 

 

 

POWER

 

 

 

 

 

 

(L1)

 

CONVERTER

 

 

 

 

 

 

BUILT-IN

 

 

 

 

 

 

 

A

B

0-5A CURRENT

 

 

TRANSFORMER

 

 

+

 

 

 

TB1

OUTPUT FROM 50:5A

 

TO 2000:5A EXTERNAL

AC or DC

CURRENT TRANSFORMER

INPUT POWER

 

Figure 1. ACA5-20PC Series Simplified Schematic

DATEL, Inc., Mansfield, MA 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E–mail: sales@datel.com Internet: www.datel.com

ACA5-20PC Series

 

 

5 A I N P UT , 3 ½ D I G I T , L E D D I S P LA Y ,

A C A M M E T E R S

Performance/Functional Specifications

 

 

 

Order on-line at www.datel.com

Typical at TA = + 25°C, unless otherwise noted.

 

 

Rated Full-Scale Current

Min.

Typ.

Max.

Units

Ordering Information

 

All Models

5.0

Amps

ACA5 - 20PC - 1 - AC1 - RL

 

Overcurrent Rating

 

1.5 x rated full-scale current

 

Performance

 

 

 

 

Input Range:

 

 

 

Sampling Rate

 

2.5 samples per second

 

 

 

 

1 = 50.0A

 

LED Color:

Accuracy

 

±0.15%FS ±6 counts

 

 

2 = 75.0A

 

RL =

Red Standard

Measurement Type

 

Sine wave input, full-wave

 

 

3 = 100.0A

 

RH = High-Intensity Red*

 

 

averaging, rms calibrated

4 = 150.0A

 

GS =

Green Standard*

Temperature Drift (0 to +60°C)

±0.2

±0.4

Counts/°C

5 = 199.9A

 

 

* Available on "DC3" +5V

Zero-Current Reading

-001

000

001

Counts

6 = 250A

Power Supply:

powered models only

 

 

 

 

 

7 = 300A

 

Dielectric WithstandingVoltage

2000

Vdc

AC1 = 85-264Vac@50/60Hz

 

Power SupplyVoltage

 

 

 

 

8 = 400A

AC2

= 85-140Vac@400Hz

 

 

 

 

 

9 = 500A

 

ACA5-20PC-X-AC1-XX

85

120

264

Vac@47-99Hz

AC3

= 240-310Vac@50/60Hz

 

10 = 600A

 

ACA5-20PC-X-AC2-XX

85

120

140

Vac@350-450Hz

DC1

= +5-40Vdc

 

11 = 750A

 

DC2

= +36-75Vdc

 

ACA5-20PC-X-AC3-XX

240

264

310

Vac@47-99Hz

 

12 = 1000A

 

DC3

= +5Vdc

 

 

 

 

 

 

 

ACA5-20PC-X-DC1-XX

+4.75

+40

Vdc

13 = 1500A

 

 

 

 

ACA5-20PC-X-DC2-XX

+36

+75

Vdc

14 = 1999A

 

 

 

ACA5-20PC-X-DC3-XX

+4.75

+5.25

Vdc

Accessories: DMS-20-CP Panel cutout punch

 

Power Supply Current

 

 

 

 

 

 

 

 

 

A DMS-BZL4 bezel assembly with sealing gasket is supplied with each ammeter.

ACA5-20PC-X-AC1,3-XX

30

50

mA@47-99Hz

 

 

 

 

ACA5-20PC-X-AC2-XX

30

50

mA@350-450Hz

 

 

 

 

ACA5-20PC-X-DC1,2-XX

+8

+12

mAdc

 

 

 

 

ACA5-20PC-X-DC3-XX

+80

+120

mAdc

Technical Notes

 

 

Power Supply Terminal Block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Size &Type

 

16-22AWG (solid or stranded)

IMPORTANT! To ensure safe and reliable operation, ACA5-20PC

Insulation Strip Length

 

 

0.25 inches

 

 

 

 

ammeters must be installed and serviced by qualified technical

Screw Tightening Torque

 

3.6 pound-inches (0.4Nm)

personnel. Contact DATEL if there is any doubt regarding

Maximum RatedVoltage

 

 

310Vac

 

ammeter installation and/or operation.

 

Display

 

 

 

 

1. Measurement Type: ACA5-20PC ac ammeters employ a full-wave-

Display Typeand Size

3½ digit LED, 0.37"/9.4mm digit height

rectified, average responding, rms-calibrated circuit to measure the

Overrange Indication

 

 

"1_ _ _"

 

stepped-down output of their built-in L1 current transformer (CT) .

Display Reading/Decimal Point

Model dependent. See Ordering Info.

Stated accuracy specifications are measured using a sine-wave

Physical/Environmental

 

 

 

 

current at or close to the full-scale input level, at nominal line

Operating Temperature

0

+60

°C

frequency.

 

 

 

Storage Temperature

–40

+75

°C

2. Calibration: Periodic recalibration of ACA5-20PC ammeters is not

Humidity (non-condensing)

0

95

%

required under normal, indoor operating environments. If user

Case Material

 

 

Polycarbonate

calibration is necessary, it should be performed by qualified technical

Dimensions

1.38"W x 0.88"H Depth is model

personnel. Calibration is performed with potentially lethal voltages

 

dependent (see Mechanical Specifications)

applied to the ACA5-20PC and its associated wiring, with the specified

Weight (all models)

 

1.1 ounces (31 grams)

full-scale current flowing through the ammeter’s built-in current

 

 

 

 

 

transformer. A plastic, fully-insulated adjusting tool must be used to

The specified Full-Scale Current is the current carried by the single wire passing through the

access the recessed calibration potentiometer located on the back of

center hole of the ACA5-20PC's on-board CT. It is not the load current ultimately being

the meter (see Mechanical Specifications). Contact DATEL if additional

measured. the Overcurrent Rating is a continuous rating that applies to the Full-Scale

information is required regarding calibration, setup, or any other

Current. It does not apply to any circuitry external to the meter.

 

Listed accuracy specifications apply over the range of the Rated Full-Scale Current over

technical issue pertaining to ACA5-20PC ammeters.

frequencies of 45-450Hz.

 

 

 

 

3. Wire Gauges and Fusing: Wires specified in the Functional

Maximum reverse polarity protection on "DC1" models is –40Vdc, and –50Vdc on "DC2"

Specifications section must be used for making connections to ACA5-

models. "DC3" models provide no reverse polarity protection.

 

All specified maximum power supply currents are steady-state. AC-powered models can

20PC Series ammeters. All power-supply and load wiring must be

draw larger surges at initial turn on.

 

 

 

 

rated for the supply voltages and currents they will conduct and must

 

 

 

 

 

comply with any code or application-mandated requirements pertaining

 

 

 

 

 

to the user’s specific installation.

 

DATEL, Inc., Mansfield, MA 02048 (USA)

Tel: (508)339-3000, (800)233-2765

Fax: (508)339-6356

E–mail: sales@datel.com Internet: www.datel.com

2