Thank you for choosing a Danby appliance to provide you and your family with all of
the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use
and Care Guide will provide you with valuable information necessary for the proper
care and maintenance of your new appliance. If properly maintained, your Danby
appliance will give you many years of trouble free operation. Please take a few
moments to read the instructions thoroughly and familiarize yourself with all of the
operational aspects of this appliance.
This unit can be conveniently moved from room to room within your home and set up
in just minutes.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this
page, along with the following information, located on the rear wall of the water tank
compartment.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for
general inquiries. To contact a Customer Service Representative, call Danby TOLL
FREE: 1-800-26-
(1-800-263-2629)
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CAUTION: Do not leave this unit unattended or operate in an area where people
or animals may not be able to react quickly. A failed unit may cause over-heating,
resulting in personal injury or property damage.
2
WARNING- IMPORTANT NOTICES
NOTE
The WARNING instructions issued in this manual are not meant to cover all possible
conditions and situations that may occur. It must be understood that common sense,
caution, and carefulness are factors that cannot be built into all appliances. These
factors must be supplied by the person(s) installing, maintaining, or operating the
appliance. Failure to install, maintain, and/or operate the equipment according to the
manufacturer’s instructions may result in conditions which can produce bodily injury
and/or property damage. Contact your dealer, service agent, or the manufacturer
about any problems or conditions you do not fully understand.
For Danby Customer Service call 1-800-26-/ 1-800-263-2629
FOR YOUR
SAFETY
To reduce the risk of fire or explosion, do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other appliance.
ELECTRICAL SERVICE
INFORMATION
It is the customer’s responsibility to have the wiring and fuses checked by a qualified
electrician to make sure adequate electrical power is available.
This appliance is designed to operate on a separate branch, polarized, three-wire,
effectively grounded 120 Volt 60 Hertz (alternating current) circuit protected by a 15
ampere fuse, equivalent fuse or circuit breaker.
The three-prong grounding plug on the power cord should be plugged directly into a
polarized, three slot, effectively grounded receptacle rated 110/120 V.A.C.
GROUNDING
INSTRUCTIONS
• This appliance must be grounded. In the event of malfunction or breakdown,
grounding will reduce the risk of electrical shock by providing a path of least resistance
for electrical current. This appliance is equipped with a cord having an equipmentgrounding conductor and 3 prong grounding plug. The plug must be connected into an
outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
• Do not modify the plug provided with this appliance. If it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
• If the household electrical supply does not meet the above specifications, or it you
are not sure your home has an effective ground, have a qualified electrician or your
local electrical utility company check it and correct any problems.
To reduce the risk of fire, electric shock, or personal injury, all
wiring and grounding must conform with the latest edition of
Local and National Electrical codes.
Improper connection of the equipment-grounding conductor can
result in a risk of electrical shock. Check with a qualified
electrician or serviceman if you are in doubt as to whether your
appliance outlets are properly grounded.
3
ELECTRICAL SPECIFICATIONS
1) All wiring must comply with local and national electrical codes and be installed by a
qualified electrician. If you have any questions regarding the following instructions,
contact a qualified electrician.
2) Check available power supply and resolve any wiring problems BEFORE installation
and operation of this unit.
3) For your safety and protection, this unit is grounded through the power cord plug
when plugged into a matching wall outlet. If you are not sure whether the wall outlets
in your home are properly grounded, please consult a qualified electrician. DO NOT
USE PLUG ADAPTERS OR EXTENSION CORDS.
4) The manufacturers nameplate is located on the rear wall of the water tank
compartment. The nameplate contains electrical and other technical data specific to
this unit.
5) To avoid the possibility of personal injury, always disconnect the power supply
before attempting to clean and/or service the unit.
UNIT SPECIFICATIONS
Model Number:
Dehumidifying Capacity (Pints / Liters)25 / 11.8
Electrical Requirements115 Volts / 60 Hz
Power Input (Watts)380
Rated Amperage (Dehumidifying)3.8
Air Flow Circulation- High Fan Speed
(Cubic Feet per Minute)180
Type of RefrigerantR22
Water Tank Capacity (Pints / Liters)5 / 10.55
Operating Noise Level (dB A)52
Unit Dimensions (Width x Height x Depth)13
Net Weight (kg / lbs)15 / 33.1
DDR2509EE
6
/16 x 19 15/16 x 10
DDR3009EE
30 / 14.2
115 volts / 60 Hz
420
4.2
180
R22
5 / 10.55
52
6
13
/16 x 19 15/16 x 10
15 / 33.1
NOTE: Specifications are subject to change without notice, for further improvements.
DDR4009EE
115 volts / 60 Hz
13 6/16 x 19 15/16 x10
40 / 18.9
525
4.8
180
R22
5 / 10.55
54
15 / 33.1
4
INSTALLATION
LOCATION
Select a suitable location, making sure you have easy access to an electrical outlet (avoid the
use of extension cords). If it is absolutely necessary to use an extension cord, use an
approved “air conditioner” heavy duty extension cord ONLY (available at most local hardware
stores).
Make sure there are no obstructions restricting airflow through the front air intake grill. Maintain
a minimum clearance of at least 20 cm (8”) between adjacent walls and the back of the unit, to
allow for proper air circulation and maximum efficiency.
To obtain maximum operating efficiency from your dehumidifier, the recommended (room
ambient) operating temperatures should be between 6°C (42.8°F)- 35°C (95°F).
It is important to remember the efficiency of a dehumidifier will be effected/influenced by the
rate at which new humid air (moisture) is allowed to infiltrate the same space/area. To maintain
efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors and windows
closed.
FEATURES
• Soft touch (Electronic) Control Key Pads
• Auto-Sensing Humidity Control
• Adjustable Humidity Settings (35% - 80%)
• 2 Fan Speed Settings (High / Low)
• Delay Start Protection (Compressor)
• Auto-Defrost (De-Icer)
• Full Bucket Indicator Light
• Easy Roll Castors (4)
• Front Mounted Water Tank (Removable)
• Direct Drain Option (Hose not Included)
• Quiet Operation
• Removable Air Filter
UNIT PARTS
IDENTIFICATION
Control Panel
Front Panel
Air Inlet
Water level
Indicator
Handle
Air Filter
(Side Panel)
Water Tank
Easy-roll Castors
5
KEY PAD FUNCTIONS
8
2
3
1) LED Readout (ROOM HUMIDITY): The
LED window displays the following information
independently:
A) Internal (Room/Environment) Relative
Humidity Conditions
B) Set Operating Relative Humidity Value.
NOTE: The LED readout is programmed to
default to display the ambient relative humidity
conditions.
To view the Set Operating Relative Humidity
Value, press the “up” or “down” button (once)
and the set RH operating value will flash for
approximately 5 seconds in the LED window,
then revert back to display the internal RH
value.
2) ON/OFF Button: Each time this button is
pressed the unit turns ON (adjacent indicator
light illuminates) or Off (adjacent indicator light
is not illuminated)
3) CONTINUOUS: Used for Continuous
Dehumidifier Operation (unit will run non-stop).
NOTE: Humidity values (settings) cannot be
programmed in this mode. The adjacent
(green) indicator light illuminates to signify the
“continous” mode is currently in operation.
1
4
5
7
6
4) HUMIDITY UP: This button allows you to
increase the relative humidity setting. Each
time this button is pressed, the RH value setting is increased incrementally by 5% (ranging
from 35% - 80%)
5) HUMIDITY DOWN: This button allows you to
decrease the relative humidity setting. Each
time this button is pressed the RH value setting
is decreased incrementally by 5% (ranging
from 80% - 35%).
6) HIGH FAN: The adjacent (green) indicator
light illuminates when HIGH FAN is selected.
7) LOW FAN: The adjacent (green) indicator
light illuminates when LOW FAN is selected.
8) WATER FULL INDICATOR: This (red) light
illuminates under the following conditions:
A) When the internal water tank is not properly
installed inside the cabinet.
B) When the internal water tank is full. The
water tank must be emptied and replaced back
in the cabinet before normal operating
conditions can resume.
6
OPERATING INSTRUCTIONS
INDICATOR LIGHT
FUNCTION
Power Light (Green):
When the unit is first connected to an electrical outlet, the (green) power light starts to flash
and continues to flash until the “on/off” button is pressed. When the “on/off” burron is activated,
the flashing (power) light turns to a steady state “on” condition. The dehumidifier will
automatically default to the factory default setting (see Factory Default Setting below for
details).
IMPORTANT NOTE: Depending on the humidity conditions of the surrounding environment,
the dehumidifier may not start automatically when the “on/off” button is pressed (see
dehumidifier operating instructions for details).
In the event of a power failure, the unit will not re-start automatically when power is restored.
To re-start the unit you must press the “on/off” keypad again.
Water Full Indicator Light (Red):
When the water tank is full and/or incorrectly positioned inside the cabinet, the (water full) red
light turns on and remains on until such time the tank is emptied and/or correctly re-positioned.
This condition will result in the immediate shut down of the dehumidifying system (both
compressor and fan motor operation are terminated). This is a safety feature. When the water
tank is emptied and/or correctly re-positioned, the dehumidifier will resume operation
automatically. NOTE: It may take several minutes before operating conditions resume.
Factory Default Setting: Each time the unit is disconnected/re-connected and/or in the event
of a power failure, the electronic circuit board automatically defaults to the following factory
setting:
Humidity Setting: 60%
Fan Speed: High
NOTE: In the event of a power failure, all previous settings are automatically erased/cancelled.
If your program setting was different than above (default setting) it will be necessary to
re-program your settings. When the unit is switched “off” manually (using the on/off keypad) the
unit will always default to the last program setting that was used.
WATER TANK
OPERATION
Proper installation of the water tank is crucial to maintaining reliable dehumidifier operation.
The water tank holds accumulated condensed water and by means of a safety switch, controls
both the water level and operation of the dehumidification process- i.e. When the water tank is
full and/or accidentally displaced inside the cabinet, the float switch actuator (inside the tank)
breaks contact with the safety switch. This condition results in the immediate shut down of the
compressor and fan motor system, preventing moisture from being condensed.
IMPORTANT: Never tamper with or attempt to defeat the water level (safety) float switch
system.
7
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.