Daikin FWF02B7TV1B, FWF03B7TV1B, FWF04B7TV1B, FWF05B7TV1B, FWF02B7FV1B Operation manuals

...
Page 1
USER MANUAL
Fan coil units
FWF02B7TV1B FWF03B7TV1B FWF04B7TV1B FWF05B7TV1B
FWF02B7FV1B FWF03B7FV1B FWF04B7FV1B FWF05B7FV1B
Cover Cover
Type numbers
Page 2
NOTES
Page 3
1 Introduction
2 Before operating
1.1 About fan coil units
1.2 About your fan coil unit
1.3 About this document
1.3.1 Meaning of warnings and symbols
2.1 Check that you have all equipment and the corresponding documentation
3 Tips for optimal operation
4 Clean your fan coil unit
5 Solve problems with your fan coil unit
6 Dispose of your fan coil unit
7 Glossary
2.2 Read the safety precautions
1
1
1
2
2
3
3
5
6
7
8
9
10
Annex: Handover of the installation to the user
11
Page 4

1 Introduction

1 Introduction
Thank you for purchasing this DAIKIN fan coil unit.
About fan coil units

1.1 About fan coil units

A fan coil unit provides heating and cooling to individual spaces. It creates a comfortable environment in both commercial and residential applications. Fan coil units are widely used for the air conditioning of offices, hotels and houses.
The main components of fan coil units are:
a fan,
a coil (heat exchanger).
The heat exchanger receives hot or cold water from a heating or cooling source. The fan spreads the heat or coolness in order to condition the space.
DAIKIN offers a wide range of fan coil units for both concealed and exposed applications. Contact your installer for a list of related products.
About your fan coil unit

1.2 About your fan coil unit

You have purchased the FWF model fan coil unit. The model identification code means:
FW
Water fan coil unit
F
Subclass:
02
B
7
T
V1
Cassette F: 2x2
To ta l cooling capacity (kW)
Major model change
Minor model change
Coil type: T: 2-pipe F: 4-pipe
1 phase / 50 Hz / 220-240 V
B
Produced in Europe
The following models are available:
FWF02-03-04-05B7TV1B
2-pipe fan coil units have one supply and one return pipe. The supply pipe can supply either hot or cold water to the unit.
FWF02-03-04-05B7FV1B
4-pipe fan coil units have two supply pipes and two return pipes. This allows either hot or cold water to enter the unit which makes it possible to heat and cool different areas of a building at the same time. Use this type if you have a separate source for cooling and for heating.
About this document
User manual
1
FWF
4PW65028-1 – 09.2010
Fan coil units
Page 5

1.3 About this document

This document is a user manual. It is written for the person who owns or operates this fan coil unit. It provides information on:
the product itself (“Introduction” on page 1),
what you should do before you operating the fan coil unit (“Before operating” on page 3),
what you should do for optimal operation of your fan coil unit (“Tips for optimal
operation” on page 6),
how you should clean your fan coil unit (“Clean your fan coil unit” on page 7),
what you should do when there is a problem with your fan coil unit (“Solve problems
with your fan coil unit” on page 8),
how you should dispose of your fan coil unit (“Dispose of your fan coil unit” on page 9),
terms that have been used in this user manual that may need clarification (“Glossary” on
page 10).
Important
This user manual does not explain how to operate your fan coil unit. You can only operate your fan coil unit by means of a controller. Therefore, the operating instructions are included in the controller box.
1 Introduction
Keep this user manual close to hand. It may come in handy later.
The original documentation is written in English. All other languages are translations of the original documentation.
About this document

1.3.1 Meaning of warnings and symbols

Warnings in this manual are classified according to their severity and probability of happening.
Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Notice: Indicates situations that may result in damage to equipment or property.
Information: This symbol identifies useful information, but no hazardous situation
warnings.
Some types of danger are represented by special symbols:
Electric current
Other symbols:
FWF
Fan coil units 4PW65028-1 – 09.2010
Danger of burning or scalding
This part of the manual is intended for the installer of this product.
User manual
2
Page 6

2 Before operating

2 Before operating
Check that you have all equipment and the corresponding documentation

2.1 Check that you have all equipment and the corresponding documentation

Extra required equipment
The fan coil unit must be used in combination with additional equipment.
This equipment must be bought separately and is required to operate the fan coil unit safely and comfortably.
Overview of additional equipment required:
decoration panel,
controller.
An overview of the types that are available:
Decoration panel
Decoration panel
Panel spacer
Identification code
BYFQ60B
KDBQ44B60
Description
Decoration panel for the fan coil unit.
Decorative spacer to fill the gap between panel and unit when the height of the suspended ceiling is too small.
Controllers
Electronic remote controller -
Identification code
BRC7E530 wireless (cooling and heating)
Electronic remote controller -
BRC7E531 wireless (cooling only)
Electronic remote controller -
BRC315D7 wired
Central remote controller
Intelligent touch controller DCS601C51C
DCS302CA51
Description
Wireless remote controller to control each fan coil unit independently with cooling and heating functionality.
Remark:
Refer to the VRV system in the operation manual.
The function “auto fan speed” is not available.
Wireless remote controller to control each fan coil unit independently with cooling functionality only.
Remark:
Refer to the VRV system in the operation manual.
The function “auto fan speed” is not available.
Wired remote controller to control each fan coil unit independently with cooling and heating functionality.
Remote controller for centralized control of all connected units.
Advanced remote controller for centralized control of all connected units.
User manual
3
FWF
4PW65028-1 – 09.2010
Fan coil units
Page 7
2 Before operating
Controllers
Unified ON/OFF controller DCS301BA51
Identification code
Description
Remote controller to switch all connected units ON or OFF.
Extra optional equipment
Optionally, you can buy additional equipment for your fan coil unit to extend the life of your product, increase the level of automation and improve its ease of use.
Overview of the optional additional equipment for your fan coil unit:
An overview of the types that are available:
air handling options,
sensor,
timer,
valves,
electronic circuits (PCB).
Air handling options
Sealing member of air discharge outlet
Identification code
KDBH44BA60
Description
Blocking parts to close one or more air outlets of the fan coil unit.
Long-life replacement filter KAFQ441BA60
Fresh air intake kit
KDDQ44XA60
High quality filter.
Kit which can be connected to the ventilation system in order to supply fresh air to the fan coil unit.
Sensor
Remote sensor
Timer
Schedule timer
Val ve s
2-way valve (ON/OFF type) EKMV2C09B7
3-way valve (ON/OFF type) EKMV3C09B7
Identification code
KRCS01-1
Identification code
DST301BA51
Identification code
Description
Replacement sensor to measure temperature remotely from a location other than that in which the controller is installed.
Description
Controller with schedule timing functionality.
Description
Electronic 2-way valve to control the water supply.
Electronic 3-way valve to control the water supply.
FWF
Fan coil units 4PW65028-1 – 09.2010
User manual
4
Page 8
2 Before operating
Electronic circuits
Valve control PCB
Optional PCB for MOD-bus
Identification code
EKRP1C11
EKFCMBCB7
connection
Wiring adaptor for electrical appendices
Remote “ON/OFF” and
KRP4A(A)53 KRP2A52
EKROROA
“Forced OFF” kit
Read the safety precautions

2.2 Read the safety precautions

Your fan coil unit is built to meet all recognized technical requirements. Operate your fan coil unit according to the instructions in the included documentation and the manuals of the additional equipment (e.g. controller). Any other usage is considered as improper and may result in property damage, serious physical injuries or death. Resulting damage caused by improper use is the sole responsibility of the user and the user alone.
To prevent any risk:
carefully read the safety precautions,
operate your fan coil unit according to the documentation.
Description
Mandatory electronic circuit when 2-way or 3-way valve is used.
Electronic circuit with MOD­bus interface connections.
Electronic circuit with additional connections for external input/output signals.
Connection to control the ON/OFF operation remotely.
Precautions for installation
The installer should install and connect your fan coil unit as described in the installation manual. Please note that the installer can only install your fan coil unit:
in a concealed ceiling,
in perfect condition.
Precautions before operating
Only operate your fan coil unit after it has been installed by a licensed installer. Verify that the installation has been completed by checking that the “Annex: Handover of the installation
to the user” on page 11 has been filled in completely.
Precautions for operating
Only operate a fan coil unit if you are fully alert and aware.
Fan coil units are not intended for use by persons with reduced physical, sensory or mental capabilities or those who have not used the fan coil unit before, including children. When these persons want to use the fan coil unit, the person responsible for their safety must supervise them or instruct them in the use of the fan coil unit.
Supervise children to ensure that they do not play with the fan coil unit.
If you feel unsure about operating the fan coil unit, contact your installer for advice and information.
User manual
5
FWF
4PW65028-1 – 09.2010
Fan coil units
Page 9
3 Tips for optimal operation
Adjust the room temperature properly for a comfortable environment. Avoid excessive heating or cooling. Notice that it may take some time for the room temperature to reach the set temperature. Consider using the timer setting options.
Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds.
Ventilate the room regularly. Using the unit for long periods of time requires attentive ventilation of the room.
Keep doors and windows closed when the unit is in operation. If the doors and windows remain open, air will flow out and decrease the effect of cooling and heating.
Never place objects near the air inlet and the air outlet of the unit. It may reduce the effectiveness or cause the unit to stop.
Turn off the main power supply switch when not using the fan coil unit for long periods of time. Electricity is consumed so long as the switch is on. Turn off the main power supply switch in order to save energy.
Fully use the function of air flow direction adjustment if available. As cold air gathers on the floor and warm air gathers against the ceiling, it is recommended to set the air flow direction during cooling operation parallel to the ceiling and to set it downwards during heating operation. Be sure that you do not direct air flow on to the inhabitants of the room.

3 Tips for optimal operation

FWF
Fan coil units 4PW65028-1 – 09.2010
User manual
6
Page 10

4 Clean your fan coil unit

4 Clean your fan coil unit
To clean the outside of your fan coil unit:
1 Switch off the fan coil unit.
2 Clean the outside of the fan coil unit with a soft cloth.
Notice
Do not pour any liquid on the fan coil unit. This could damage the components inside it.
Never clean your fan coil unit with:
any aggressive chemical solvent,
water hotter than 50°C.
For maintenance of your fan coil unit, contact your installer or service company.
User manual
7
FWF
4PW65028-1 – 09.2010
Fan coil units
Page 11

5 Solve problems with your fan coil unit

5 Solve problems with your fan coil unit
When your fan coil unit does not function well, you can try to solve any problem with the corrective actions in this chapter.
If the problem persists or is not addressed in this chapter, contact your installer or service company.
Your fan coil unit does not function
If your fan coil unit does not function:
Check:
Has the fan coil unit been switched OFF? Switch the fan coil unit ON.
Is there a power failure?
Has the circuit breaker (fuse) been tripped? Contact your installer or service company.
Your fan coil unit does not cool or heat well
If your fan coil unit does not cool or heat well:
Check:
Is there an obstacle near the air inlet or air outlet?
Are any doors and windows open?
Is the fan coil unit running at low speed? Select medium speed or high speed.
Are the air filters dirty?
If yes,
Restore the power supply.
If yes,
Remove the obstacle.
Close doors and windows.
Contact your installer or service company.
Your fan coil unit leaks water
Shut down the unit and contact your installer or service company.
FWF
Fan coil units 4PW65028-1 – 09.2010
User manual
8
Page 12

6 Dispose of your fan coil unit

6 Dispose of your fan coil unit
Your fan coil unit was designed to be environment friendly. DAIKIN has complied with the standards for environmentally-friendly disposal. This means that you have to dispose of your fan coil unit in accordance with the applicable legislation. By ensuring this product is disposed of correctly, you help to prevent potential negative consequences for the environment and human health.
Fig. 6.1: WEEE symbol
Your fan coil unit is categorized as an electrical and electronic product. It is marked with the symbol illustrated in figure “WEEE symbol” on page 9. This symbol means that your fan coil unit should be recycled and not disposed of in unsorted municipal waste.
To dispose of your fan coil unit, contact your installer. The installer and qualified instances will:
dismantle the fan coil unit,
re-use, recycle and recover parts of the fan coil unit.
Warning
Never dismantle the fan coil unit yourself.
DAIKIN and the environment thank you!
User manual
9
FWF
4PW65028-1 – 09.2010
Fan coil units
Page 13
7 Glossary

7 Glossary

Term
Air filter:
Applicable legislation:
Circuit breaker (fuse):
Coil (heat exchanger):
Controller:
Fan:
Fan coil unit:
Meaning
Device composed of fibrous materials which removes solid particulates such as dust, pollen, mould and bacteria from the air
All international, European, national and local directives, laws, regulations and/or codes which are relevant and applicable for a certain product or domain
Safety device used in electrical installations to prevent electric shock
Main component of a fan coil unit. Receives hot or cold water from a heat source
Device to configure and operate the fan coil unit
Main component of a fan coil unit. Spreads heat or coolness in a space
Heating and cooling product
Air inlet/outlet:
Fan coil units have an air inlet and air outlet for providing air circulation
Installer:
Technical skilled person who is qualified to install fan coil units and other DAIKIN products
Optional
Equipment which can optionally be combined to the fan coil unit
equipment:
Service company: Qualified company which can perform or coordinate the required
service to the fan coil unit
User:
Person who is owner of the fan coil unit and/or operates the product
FWF
Fan coil units 4PW65028-1 – 09.2010
User manual
10
Page 14

Annex: Handover of the installation to the user

Annex: Handover of the installation to the user
To be filled in by the installer once the test run is finished and the fan coil unit(s) operate(s) properly.
Tick when checked.
Explain to the user what system is installed on site.
Complete the ID cards below for each installed fan coil unit. This information may be useful for the user in future servicing. Fill in the place of installation (room), the model name (see nameplate of the fan coil unit) and list the optional equipment which is installed.
Fan coil unit 1
Place of installation:
Model name:
Optional equipment:
Fan coil unit 3
Place of installation:
Model name:
Optional equipment:
Fan coil unit 5
Place of installation:
Model name:
Optional equipment:
Fan coil unit 2
Place of installation:
Model name:
Optional equipment:
Fan coil unit 4
Place of installation:
Model name:
Optional equipment:
Fan coil unit 6
Place of installation:
Model name:
Optional equipment:
User manual
11
Fan coil unit 7
Place of installation:
Model name:
Optional equipment:
Fan coil unit 8
Place of installation:
Model name:
Optional equipment:
Fan coil units
4PW65028-1 – 09.2010
FWF
Page 15
Annex: Handover of the installation to the user
Tick when checked.
Ensure that the user has a printed version of the user manual and the installation manual and ask him/her to keep it for future reference.
Explain the user how to properly operate the system, and what he/she has to do in case of problems.
Show the user what maintenance jobs he/she has to do in relation to cleaning the unit.
Date:
Signature:
Your DAIKIN product was installed by:
FWF
Fan coil units 4PW65028-1 – 09.2010
User manual
12
Page 16
Cover Rear Cover Rear
4PW65028-1 09.2010
Copyright 2010 Daikin