Safety precautions ......................................... 2
Names of parts............................................... 4
Preparation Before Operation ........................ 7
OPERATION
AUTO · DRY · COOL · HEAT · FAN Operation
Adjusting the Air Flow Direction ................... 12
POWERFUL Operation ................................ 14
OUTDOOR UNIT SILENT Operation .......... 15
INTELLIGENT EYE Operation ..................... 16
TIMER Operation ......................................... 18
CARE
Care and Cleaning ....................................... 20
TROUBLE SHOOTING
Trouble Shooting.......................................... 23
... 10
1
READ BEFORE OPERATION
Safety precautions
Keep this manual where the operator can easily find them.
Read this manual attentively before starting up the unit.
For safety reason the operator must read the following cautions carefully.
This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: they are all important for ensuring safety.
WARNING
If you do not follow these instructions exactly, the unit may cause property damage, personal injury or loss of life.
Never do. Be sure to follow the instructions.
Be sure to earth the air conditioner.
Never touch the air conditioner (including the remote
controller) with a wet hand.
If you do not follow these instructions exactly, the unit may cause minor or moderate property damage or personal injury.
Never cause the air conditioner (including the remote
controller) to get wet.
CAUTION
WARNING
In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable or corrosive gases, are detected near the unit.
It is not good for health to expose your body to the air flow for a long time.
Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury.
Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information.
Do not insert fingers, poles, or other objects into the moving parts of the top front panel or the bottom front panel.
The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range.
If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer. When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff.
Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or fire. For installation, consult the dealer or a qualified technician.
In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation and turn off the breaker. And call your dealer for instructions.
CAUTION
The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line.
In order to avoid any quality deterioration, do not use the unit for cooling precision instru­ments, food, plants, animals or works of art.
Never expose little children, plants or animals directly to the air flow.
Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.
2
Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble.
Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard.
Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip.
After a long use, check the unit stand and fittings for damage.
Do not touch the air inlet and aluminum fins of outdoor unit. It may cause injury.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used together with the air conditioner.
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord.
Do not connect the air conditioner to a power supply different from the one as specified. It may cause trou­ble or fire.
Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may result in electric shocks.
Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the building, furniture etc.
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunc­tions, smoke or fire when making contact with electrical parts.
Do not operate the air conditioner with wet hands.
Do not wash the indoor unit with excessive water, only use a slightly wet cloth.
Do not place things such as vessels containing water or anything else on top of the unit. Water may pene­trate into the unit and degrade electrical insulations, resulting in an electric shock.
Installation site
To install the air conditioner in the following types of environments, consult the dealer.
Places with an oily ambient or where steam or soot occurs.
Salty environment such as coastal areas.
Places where sulfide gas occurs such as hot springs.
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.
Consider nuisance to your neighbours from noises
For installation, choose a place as described below.
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
• A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours
.
Electrical work
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation
Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if reloca­tion is necessary for moving or remodeling.
3
Names of parts
Indoor Unit
134
2
5
6
18
14 15 16
7 8 9
11
(With the panel closed)
10
17
13
12
4
Outdoor Unit
19
21
22
20
■■■■
Indoor Unit
1. Air filter
2. Titanium Apatite Photocatalytic Air-Purifying Filter:
These filters are attached to the inside of
the air filters.
3. Air inlet
4. Top front panel
5. Supporting plate:
The supporting plate is used to support
the front panel during maintenance.
6. Panel tab
7. Flap (horizontal blade): (page 12.)
8. Air outlet
9. Louvers (vertical blades):
The louvers are inside of the air outlet.
(page 12.)
10. Bottom front panel
11. Display
12. Indoor Unit ON/OFF switch: (page 10.)
Push this switch once to start operation.
Push once again to stop it.
23
The operation mode refers to the following table.
Mode
AUTO
This switch is useful when the remote controller is missing.
13. Room temperature sensor:
It senses the air temperature around the unit.
14. Operation lamp (green)
15. TIMER lamp (yellow): (page 18.)
INTELLIGENT EYE lamp (green)
16.
17. INTELLIGENT EYE sensor:
It detects the movements of people and auto-
matically switches between normal operation and energy saving operation. (page 16.)
18. Signal receiver:
It receives signals from the remote controller.
When the unit receives a signal, you will hear a short beep.
Operation start .............beep-beep
Settings changed ..........beep
Operation stop ..............beeeeep
Temperature
setting
25°C
: (page 16.)
Air flow
rate
AUTO
■■■■
Outdoor Unit
19. Air inlet: (Back and side)
20. Air outlet
21. Refrigerant piping and inter-unit cable
Appearance of the outdoor unit may differ from some models.
22. Drain hose
23. Earth terminal:
It is inside of this cover.
5
Remote Controller
2
3
4
1
5
6
9
7
8
13
14
15
<
ARC433A41
1. Signal transmitter:
It sends signals to the indoor unit.
2. Display:
It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.)
3. SENSOR button: for INTELLIGENT EYE operation (page 16.)
4. POWERFUL button: for POWERFUL operation (page 14.)
5. TEMPERATURE adjustment buttons:
It changes the temperature setting.
6. ON/OFF button:
Press this button once to start operation.
Press once again to stop it.
7. MODE selector button:
It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN) (page 10.)
10
11
12
16
17
>
8. SILENT button: for OUTDOOR UNIT SILENT operation
9. FAN setting button:
It selects the air flow rate setting.
10. SWING button: (page 12.)
Flap (Horizontal blade)
11. SWING button: (page 12.)
Louvers (Vertical blades)
12. COMFORT AIRFLOW mode button:
(page 13.)
13. ON TIMER button: (page 19.)
14. OFF TIMER button: (page 18.)
15. TIMER Setting button:
It changes the time setting.
16. TIMER CANCEL button:
It cancels the timer setting.
17. CLOCK button: (page 9.)
(page 15.)
6
Preparation Before Operation
To set the batteries
1. Press with a finger and slide the front cover to take it off.
2. Set two dry batteries (AAA).
3. Set the front cover as before.
1
Position + and – correctly!
2
3
ATTENTION
■■■■
About batteries
When replacing the batteries, use batteries of the same type, and replace the two old batteries together.
When the system is not used for a long time, take the batteries out.
We recommend replacing once a year, although if the remote controller display begins to fade or if reception deteriorates, please replace with new alkali batteries. Using manganese batteries reduces the lifespan.
The attached batteries are provided for the initial use of the system. The usable period of the batteries may be short depending on the manufactured date of the air conditioner.
7
Preparation Before Operation
To operate the remote controller
To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate.
Do not drop the remote controller. Do not get it wet.
The maximum distance for communication is about 7 m.
To fix the remote controller holder on the wall
1. Choose a place from where the signals reach the unit.
2. Fix the holder to a wall, a pillar, or similar location with the screws procured locally.
Set.
Receiver
Remote controller holder
3. Place the remote controller in the remote controller holder.
To remove, pull it upwards.
Turn on the power breaker
Turning on the power breaker will cause the panel and flap to open once and then close again. (This is a normal procedure.)
CAUTION
During operation (i.e. when the panel is open or being opened or closed), do not touch the panel with your hands.
ATTENTION
■■■■
About remote controller
Never expose the remote controller to direct sunlight.
Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth.
Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such
as inverter-type lamps) is in the room. Consult the shop if that is the case.
If the remote controller signals happen to operate another appliance, move that appliance
to somewhere else, or consult the shop.