Daikin D-Series, E-Series Service Manual

Si12 - 619A
[Applied Models]
Inverter Multi : Cooling OnlyInverter Multi : Heat Pump
D-Series / E-Series
Si12-619A
SUPER MULTI NX
D-Series / E-Series
zCooling Only Indoor Unit
FTKS25DVM FDKS25CAVMB FFQ25B8V1B FTKS35DVM FDKS35CAVMB FFQ35B8V1B FTKS50BVMB FDKS50CVMB FFQ50B8V1B FTKS60BVMB FDKS60CVMB FFQ60B8V1B FTKS71BVMB FDKS25EAVMB FTKS20DVMA FDKS35EAVMB FTKS25EVMA CDKS25CVMA FTKS35EVMA CDKS35CVMA FTKS50FVM CDKS50CVMA FTKS60FVM CDKS60CVMA FTKS71FVM CDKS25DVMT FTKS50FVMA CDKS35DVMT FTKS60FVMA CDKS50DVMT FTKS71FVMA CDKS60DVMT FTKS20DVMT CDKS25EAVMA FTKS25DVMT CDKS35EAVMA FTKS35DVMT CDKS25EAVMT FTKS50DVMT CDKS35EAVMT FTKS60DVMT FTKS71DVMT FTKS50FVLT FTKS60FVLT FTKS71FVLT
Outdoor Unit
3MKS58EVMA 3MKS90EVLT 3MKS50DVM 3MKS75EVMA 4MKS100EVLT 4MKS71DVM 4MKS90EVMA 3MKS50ESG
3MKS71ESG 4MKS80ESG
Si12-619A
ii Table of Contents
zHeat Pump Indoor Unit
FTXS20DVMA FDXS25CVMA FLXS25BVMA FTXS25EVMA FDXS35CVMA FLXS35BVMA FTXS35EVMA FDXS50CVMA FLXS50BVMA FTXS50FVMA FDXS60CVMA FLXS60BVMA FTXS60FVMA CDXS25DVMT FVXS35BVMA FTXS71FVMA CDXS35DVMT FVXS50BVMA FTXS20DVMT CDXS50DVMT FFQ25B8V1B FTXS25DVMT CDXS60DVMT FFQ35B8V1B FTXS35DVMT CDXS25EAVMA FFQ50B8V1B FTXS50DVMT CDXS35EAVMA FFQ60B8V1B FTXS60DVMT CDXS25EAVMT FTXS71DVMT CDXS35EAVMT FTXS50FVLT FTXS60FVLT FTXS71FVLT
Outdoor Unit
3MXS52EVMA 3MXS90EVLT 3MXS68EVMA 4MXS100EVLT 4MXS80EVMA
Si12-619A
Table of Contents iii
1. Introduction ........................................................................................... vii
1.1 Safety Cautions ...................................................................................... vii
1.2 Used Icons .............................................................................................. xi
Part 1 List of Functions ................................................................ 1
1. List of Functions......................................................................................2
1.1 Cooling Only.............................................................................................2
1.2 Heat Pump .............................................................................................10
Part 2 Specifications ..................................................................17
1. Specifications........................................................................................18
1.1 Indoor Units - Cooling Only ....................................................................18
1.2 Outdoor Units - Cooling Only .................................................................32
1.3 Indoor Units - Heat Pump .......................................................................38
1.4 Outdoor Units - Heat Pump ....................................................................48
Part 3 Printed Circuit Board Connector Wiring Diagram ...........51
1. Printed Circuit Board Connector Wiring Diagram.................................52
1.1 Wall Mounted Type ................................................................................52
1.2 Duct Connected Type.............................................................................56
1.3 Floor / Ceiling Suspended Dual Type.....................................................58
1.4 Floor Standing Type ...............................................................................61
1.5 Ceiling Mounted Cassette Type (600×600)............................................64
1.6 Outdoor Units – E Series (50-58 Class, 80-100 Class) ..........................67
1.7 Outdoor Units – E Series (68-75 Class) .................................................70
1.8 Outdoor Units – D Series .......................................................................73
Part 4 Function and Control........................................................77
1. Main Functions......................................................................................78
1.1 Frequency Principle................................................................................78
1.2 Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing ..........80
1.3 Fan Speed Control for Indoor Units........................................................81
1.4 Programme Dry Function .......................................................................82
1.5 Automatic Operation...............................................................................83
1.6 Thermostat Control.................................................................................84
1.7 Night Set Mode.......................................................................................85
1.8 ECONO Mode ........................................................................................86
1.9 MOLD PROOF Operation ......................................................................87
1.10 INTELLIGENT EYE (Wall Mounted Type Only) .....................................88
1.11 HOME LEAVE Operation .......................................................................90
1.12 Inverter POWERFUL Operation .............................................................91
1.13 Other Functions......................................................................................92
2. Function of Main Structural Parts..........................................................94
2.1 Main Structural Parts ..............................................................................94
2.2 Function of Thermistor ...........................................................................95
3. Control Specification .............................................................................99
3.1 Mode Hierarchy ......................................................................................99
3.2 Frequency Control................................................................................100
3.3 Controls at Mode Changing / Start-up..................................................103
Si12-619A
iv Table of Contents
3.4 Discharge Pipe Temperature Control...................................................104
3.5 Input Current Control ............................................................................104
3.6 Freeze-up Protection Control ...............................................................105
3.7 Heating Peak-cut Control .....................................................................105
3.8 Fan Control...........................................................................................106
3.9 Liquid Compression Protection Function 2...........................................106
3.10 Defrost Control .....................................................................................107
3.11 Low Hz High Pressure Limit .................................................................108
3.12 Electronic Expansion Valve Control .....................................................108
3.13 Malfunctions .........................................................................................112
3.14 Forced Operation Mode .......................................................................113
3.15 Wiring-Error Check ...............................................................................114
3.16 Additional Function...............................................................................116
Part 5 Operation Manual ...........................................................119
1. System Configuration..........................................................................120
1.1 Operation Instructions ..........................................................................120
2. Instruction............................................................................................121
2.1 FTK(X)S, CDK(X)S, FDK(X)S, FLXS, FVXS Series.............................121
2.2 FFQ 25/35/50/60 B...............................................................................189
Part 6 Service Diagnosis...........................................................201
1. Caution for Diagnosis.........................................................................202
1.1 Troubleshooting with Operation Lamp .................................................202
2. Problem Symptoms and Measures.....................................................204
3. Service Check Function ......................................................................205
4. Code Indication on the Remote Controller..........................................208
4.1 Error Codes and Description of Fault ...................................................208
5. Troubleshooting ..................................................................................209
5.1 Indoor Units ..........................................................................................209
5.2 Outdoor Units .......................................................................................210
5.3 Indoor Unit PCB Abnormality ...............................................................211
5.4 Freeze-up Protection Control or High Pressure Control.......................212
5.5 Fan Motor or Related Abnormality .......................................................214
5.6 Thermistor or Related Abnormality (Indoor Unit)..................................217
5.7 Shutter Drive Motor / Shutter Limit Switch Abnormality .......................218
5.8 Signal Transmission Error (between Indoor and Outdoor Units)..........219
5.9 Unspecified Voltage (between Indoor and Outdoor Units)...................221
5.10 Freeze-up Protection Control ...............................................................222
5.11 Outdoor Unit PCB Abnormality.............................................................224
5.12 OL Activation (Compressor Overload) .................................................225
5.13 Compressor Lock .................................................................................226
5.14 DC Fan Lock ........................................................................................228
5.15 Input Over Current Detection ...............................................................229
5.16 Four Way Valve Abnormality................................................................231
5.17 Discharge Pipe Temperature Control...................................................233
5.18 High Pressure Control in Cooling .........................................................234
5.19 Compressor Sensor System Abnormality ............................................236
5.20 Position Sensor Abnormality ................................................................238
5.21 CT or Related Abnormality ...................................................................239
Si12-619A
Table of Contents v
5.22 Thermistor or Related Abnormality (Outdoor Unit) ...............................241
5.23 Electrical Box Temperature Rise ..........................................................243
5.24 Radiation Fin Temperature Rise ..........................................................247
5.25 Output Over Current Detection.............................................................251
5.26 Insufficient Gas.....................................................................................253
5.27 Low-voltage Detection or Over-voltage Detection................................257
5.28 Signal Transmission Error (on Outdoor Unit PCB)...............................258
5.29 Anti-icing Function in Other Rooms / Unspecified Voltage
(between Indoor and Outdoor Units) ....................................................259
6. Check ..................................................................................................260
6.1 How to Check .......................................................................................260
Part 7 Removal Procedure ........................................................271
1. Outdoor Unit – E Series (50 / 52 / 58 Class).......................................272
1.1 Removal of the Panels and Plates .......................................................272
1.2 Removal of the Electrical Box ..............................................................277
1.3 Removal of the PCB.............................................................................284
1.4 Removal of the Propeller Fan / Fan Motor ...........................................290
1.5 Removal of the Sound Blanket.............................................................292
1.6 Removal of Electronic Expansion Valve Coil,
Four Way Valve Coil and Thermistor ...................................................296
1.7 Removal of the Distributor....................................................................299
1.8 Removal of the Four Way Valve...........................................................300
1.9 Removal of the Compressor.................................................................301
2. Outdoor Unit – E Series (68 / 71 / 75 Class), D Series .......................303
2.1 Removal of the Outer Panels ...............................................................303
2.2 Removal of the Electrical BOX .............................................................304
2.3 Removal of the PCB.............................................................................308
2.4 Removal of the Fan Motor....................................................................311
2.5 Removal of the Sound Blanket.............................................................312
2.6 Removal of the Four Way Valve Coil, Solenoid Valve Coil,
Electronic Expansion Valve Coil and Thermistor .................................313
2.7 Removal of the Four Way Valve, Solenoid Valve and Shunt ...............315
2.8 Removal of the Solenoid Valve and Shunt...........................................316
2.9 Removal of the Compressor.................................................................317
3. Outdoor Unit – E Series (80 / 90 / 100 Class).....................................318
3.1 Removal of Outer Panels .....................................................................318
3.2 Removal of the Electrical Box ..............................................................334
3.3 Removal of PCB...................................................................................340
3.4 Removal of Fan Motor..........................................................................344
3.5 Removal of Coils / Thermistors ............................................................345
3.6 Removal of Sound Blanket...................................................................351
3.7 Removal of Compressor.......................................................................354
Part 8 Others .............................................................................355
1. Others .................................................................................................356
1.1 Test Run from the Remote Controller ..................................................356
1.2 Jumper Settings ...................................................................................357
1.3 Application of Silicon Grease to a Power Transistor and
a Diode Bridge......................................................................................358
Si12-619A
vi Table of Contents
Part 9 Appendix.........................................................................359
1. Piping Diagrams..................................................................................360
1.1 Indoor Units ..........................................................................................360
1.2 Outdoor Units .......................................................................................364
2. Wiring Diagrams..................................................................................370
2.1 Indoor Units ..........................................................................................370
2.2 Outdoor Units .......................................................................................376
Index .............................................................................................i
Drawings & Flow Charts .............................................................. vii
Si12-619A Introduction
vii
1. Introduction
1.1 Safety Cautions
Cautions and Warnings
Be sure to read the following safety cautions before conducting repair work.
The caution items are classified into “ Warning” and “ Caution”. The “ Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “ Caution” items can also lead to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety caution items described below.
About the pictograms
This symbol indicates the item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates the prohibited action.
The prohibited item or action is shown in the illustration or near the symbol.
This symbol indicates the action that must be taken, or the instruction.
The instruction is shown in the illustration or near the symbol.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates normally, and explain the cautions for operating the product to the customer.
1.1.1 Cautions Regarding Safety of Workers
Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for repair. Working on the equipment that is connected to the power supply may cause an electrical shook. If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not touch any electrically charged sections of the equipment.
If the refrigerant gas is discharged during the repair work, do not touch the discharged refrigerant gas. The refrigerant gas may cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at the welded section, evacuate the refrigerant gas completely at a well-ventilated place first. If there is a gas remaining inside the compressor, the refrigerant gas or refrigerating machine oil discharges when the pipe is disconnected, and it may cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas may generate toxic gases when it contacts flames.
The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit. Be sure to discharge the capacitor completely before conducting repair work. A charged capacitor may cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug. Plugging or unplugging the power cable plug to operate the equipment may cause an electrical shock or fire.
Introduction Si12-619A
viii
Be sure to wear a safety helmet, gloves, and a safety belt when working at a high place (more than 2m). Insufficient safety measures may cause a fall accident.
In case of R410A refrigerant models, be sure to use pipes, flare nuts and tools for the exclusive use of the R410A refrigerant. The use of materials for R22 refrigerant models may cause a serious accident such as a damage of refrigerant cycle as well as an equipment failure.
Warning
Caution
Do not repair the electrical components with wet hands. Working on the equipment with wet hands may cause an electrical shock.
Do not clean the air conditioner by splashing water. Washing the unit with water may cause an electrical shock.
Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical shocks.
Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The internal fan rotates at a high speed, and cause injury.
Be sure to conduct repair work with appropriate tools. The use of inappropriate tools may cause injury.
Be sure to check that the refrigerating cycle section has cooled down enough before conducting repair work. Working on the unit when the refrigerating cycle section is hot may cause burns.
Use the welder in a well-ventilated place. Using the welder in an enclosed room may cause oxygen deficiency.
Si12-619A Introduction
ix
1.1.2 Cautions Regarding Safety of Users
Warning
Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools may cause an electrical shock, excessive heat generation or fire.
If the power cable and lead wires have scratches or deteriorated, be sure to replace them. Damaged cable and wires may cause an electrical shock, excessive heat generation or fire.
Do not use a joined power cable or extension cable, or share the same power outlet with other electrical appliances, since it may cause an electrical shock, excessive heat generation or fire.
Be sure to use an exclusive power circuit for the equipment, and follow the local technical standards related to the electrical equipment, the internal wiring regulations, and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work may cause an electrical shock or fire.
Be sure to use the specified cable for wiring between the indoor and outdoor units. Make the connections securely and route the cable properly so that there is no force pulling the cable at the connection terminals. Improper connections may cause excessive heat generation or fire.
When wiring between the indoor and outdoor units, make sure that the terminal cover does not lift off or dismount because of the cable. If the cover is not mounted properly, the terminal connection section may cause an electrical shock, excessive heat generation or fire.
Do not damage or modify the power cable. Damaged or modified power cable may cause an electrical shock or fire. Placing heavy items on the power cable, and heating or pulling the power cable may damage the cable.
Do not mix air or gas other than the specified refrigerant (R410A / R22) in the refrigerant system. If air enters the refrigerating system, an excessively high pressure results, causing equipment damage and injury.
If the refrigerant gas leaks, be sure to locate the leaking point and repair it before charging the refrigerant. After charging refrigerant, make sure that there is no refrigerant leak. If the leaking point cannot be located and the repair work must be stopped, be sure to perform pump-down and close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas itself is harmless, but it may generate toxic gases when it contacts flames, such as fan and other heaters, stoves and ranges.
When relocating the equipment, make sure that the new installation site has sufficient strength to withstand the weight of the equipment. If the installation site does not have sufficient strength and if the installation work is not conducted securely, the equipment may fall and cause injury.
Introduction Si12-619A
x
Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet securely. If the plug has dust or loose connection, it may cause an electrical shock or fire.
Be sure to install the product correctly by using the provided standard installation frame. Incorrect use of the installation frame and improper installation may cause the equipment to fall, resulting in injury.
For unitary type only
Be sure to install the product securely in the installation frame mounted on the window frame. If the unit is not securely mounted, it may fall and cause injury.
For unitary type only
When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent children from swallowing it. If a child swallows the coin battery, see a doctor immediately.
Warning
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks. If the combustible gas leaks and remains around the unit, it may cause a fire.
Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections may cause excessive heat generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it. Corroded installation platform or frame may cause the unit to fall, resulting in injury.
Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding may cause an electrical shock.
Si12-619A Introduction
xi
1.2 Used Icons
Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in the table below:
Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M or higher. Faulty insulation may cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair. Faulty drainage may cause the water to enter the room and wet the furniture and floor.
Do not tilt the unit when removing it. The water inside the unit may spill and wet the furniture and floor.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not installed properly, water may enter the room and wet the furniture and floor.
For unitary type only
Caution
Icon Type of
Information
Description
Note:
Note A “note” provides information that is not indispensable, but may
nevertheless be valuable to the reader, such as tips and tricks.
Caution
Caution A “caution” is used when there is danger that the reader, through
incorrect manipulation, may damage equipment, loose data, get an unexpected result or has to restart (part of) a procedure.
Warning
Warning A “warning” is used when there is danger of personal injury.
Reference A “reference” guides the reader to other places in this binder or
in this manual, where he/she will find additional information on a specific topic.
Introduction Si12-619A
xii
Si12-619A
List of Functions 1
Part 1
List of Functions
1. List of Functions......................................................................................2
1.1 Cooling Only.............................................................................................2
1.2 Heat Pump .............................................................................................10
List of Functions Si12-619A
2 List of Functions
1. List of Functions
1.1 Cooling Only
Category Functions
FTKS25/35DVM
FTKS50-71BVMB
Category Functions
FTKS25/35DVM
FTKS50-71BVMB
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB)
——
Operation Limit for Heating (°CWB) Photocatalytic Deodorizing Filter
PAM Control
Air Purifying Filter with Photocatalytic Deodorizing Function
{
Compressor Oval Scroll Compressor
Swing Compressor
Titanium Apatite Photocatalytic Air-Purifying Filter
{
Rotary Compressor
Reluctance DC Motor Mold Proof Air Filter
{{
Comfortable Airflow
Power-Airflow Flap Wipe-clean Flat Panel
{{
Power-Airflow Dual Flaps
{{
Washable Grille
Power-Airflow Diffuser Mold Proof Operation
{
Wide-Angle Louvers
{{
Heating Dry Operation
Vertical Auto-Swing (Up and Down)
{{
Good-Sleep Cooling Operation
Horizontal Auto-Swing (Right and Left)
{
Timer 24-Hour On/Off Timer
{{
3-D Airflow
{
Night Set Mode
{{
Comfort Airflow Mode Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
{{
3-Step Airflow (H/P Only) Self-Diagnosis (Digital, LED) Display
{{
Comfort Control
Auto Fan Speed
{{
Wiring Error Check
Indoor Unit Quiet Operation
{{
Anticorrosion Treatment of Outdoor Heat Exchanger
——
Night Quiet Mode (Automatic)
Outdoor Unit Quiet Operation (Manual)
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{
Intelligent Eye
{{
Flexible Voltage Correspondence
{{
Quick Warming Function High Ceiling Application
Hot-Start Function Chargeless
Automatic Defrosting Either Side Drain (Right or Left)
{{
Operation Automatic Operation Power Selection
Programme Dry Function
{{
Remote Control
5-Rooms Centralized Controller (Option)
{{
Fan Only
{{
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation
{{
Remote Control Adaptor (Normal Open Contact) (Option)
{{
Priority-Room Setting
Cooling / Heating Mode Lock DIII-NET Compatible (Adaptor) (Option)
{{
Home Leave Operation
{
Remote Controller
Wireless
{{
ECONO Mode
{
—Wired
Indoor Unit On/Off Switch
{{
Signal Reception Indicator
{{
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
Si12-619A List of Functions
List of Functions 3
Category Functions
FTKS20DVMA
FTKS25/35EVMA
FTKS50-71FVM
FTKS50-71FVMA
Category Functions
FTKS20DVMA
FTKS25/35EVMA
FTKS50-71FVM
FTKS50-71FVMA
Basic Function
Inverter (with Inverter Power Control)
{{{
Health & Clean
Air Purifying Filter — — —
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter — — —
Operation Limit for Heating (°CWB) — — —
Air Purifying Filter with Photocatalytic Deodorizing Function
———
PAM Control — — —
Titanium Apatite Photocatalytic Air-Purifying Filter
{{{
Compressor
Oval Scroll Compressor — — — Mold Proof Air Filter
{{{
Swing Compressor — — — Wipe-clean Flat Panel
{{{
Rotary Compressor — — — Washable Grille — — —
Reluctance DC Motor — — — Mold Proof Operation
{
Comfortable Airflow
Power-Airflow Flap — — — Heating Dry Operation — — —
Power-Airflow Dual Flaps
{
{
{
Good-Sleep Cooling Operation — — —
Power-Airflow Diffuser — — —
Timer
24-Hour On/Off Timer
{
{
{
Wide-Angle Louvers
{
{
{
Night Set Mode
{
{
{
Vertical Auto-Swing (Up and Down)
{
{
{
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{
{
{
Horizontal Auto-Swing (Right and Left)
{
{
Self-Diagnosis (Digital, LED) Display
{
{
{
3-D Airflow
{
{
Wiring-Error Check — — —
Comfort Airflow Mode — — —
Anticorrosion Treatment of Outdoor Heat Exchanger
———
3-Step Airflow (H/P Only) — — —
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
{
{
Comfort Control
Auto Fan Speed
{
{
{
Flexible Voltage Correspondence
{
{
{
Indoor Unit Quiet Operation
{
{
{
High Ceiling Application — — —
Night Quiet Mode (Automatic) — — — Chargeless — — —
Outdoor Unit Quiet Operation (Manual) — — — Either Side Drain (Right or Left)
{
{
{
Intelligent Eye
{
{
{
Power-Selection — — —
Quick Warming Function — — —
Remote Control
5-Rooms Centralized Controller (Option)
{
{
{
Hot-Start Function — — —
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{
{
{
Automatic Defrosting — — —
Remote Control Adaptor (Normal Open Contact) (Option)
{
{
{
Operation
Automatic Operation — — — Dlll-NET Compatible (Adaptor) (Option)
{
{
{
Programme Dry Function
{
{
{
Remote Controller
Wireless
{
{
{
Fan Only
{
{
{
Wired ———
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation
{
{
{
Priority-Room Setting — — —
Cooling / Heating Mode Lock — — —
Home Leave Operation
{
{
ECONO Mode
{
Indoor Unit On/Off Switch
{
{
{
Signal Reception Indicator
{
{
{
Temperature Display — — —
Another Room Operation — — —
Note:
{
: Holding Functions
— : No Functions
List of Functions Si12-619A
4 List of Functions
Category Functions
FTKS20-35DVMT
FTKS50-71DVMT
FTKS50-71FVLT
Category Functions
FTKS20-35DVMT
FTKS50-71DVMT
FTKS50-71FVLT
Basic Function
Inverter (with Inverter Power Control)
{{{
Health & Clean
Air Purifying Filter — — —
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter — — —
Operation Limit for Heating (°CWB) — — —
Air Purifying Filter with Photocatalytic Deodorizing Function
{
PAM Control — — —
Titanium Apatite Photocatalytic Air-Purifying Filter
{
{
Compressor
Oval Scroll Compressor — — — Mold Proof Air Filter
{{{
Swing Compressor — — — Wipe-clean Flat Panel
{{{
Rotary Compressor — — — Washable Grille — — —
Reluctance DC Motor — — — Mold Proof Operation
{
——
Comfortable Airflow
Power-Airflow Flap — — — Heating Dry Operation — — —
Power-Airflow Dual Flaps
{{{
Good-Sleep Cooling Operation — — —
Power-Airflow Diffuser — — —
Timer
24-Hour On/Off Timer
{{{
Wide-Angle Louvers
{{{
Night Set Mode
{{{
Vertical Auto-Swing (Up and Down)
{{{
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{{{
Horizontal Auto-Swing (Right and Left)
{{
Self-Diagnosis (Digital, LED) Display
{{{
3-D Airflow
{{
Wiring-Error Check — — —
Comfort Airflow Mode — — —
Anticorrosion Treatment of Outdoor Heat Exchanger
———
3-Step Airflow (H/P Only) — — —
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{{
Comfort Control
Auto Fan Speed
{{{
Flexible Voltage Correspondence
{{
Indoor Unit Quiet Operation
{{{
High Ceiling Application — — —
Night Quiet Mode (Automatic) — — — Chargeless — — —
Outdoor Unit Quiet Operation (Manual) — — — Either Side Drain (Right or Left)
{{{
Intelligent Eye
{{{
Power-Selection — — —
Quick Warming Function — — —
Remote Control
5-Rooms Centralized Controller (Option)
{{{
Hot-Start Function — — —
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{{
Automatic Defrosting — — —
Remote Control Adaptor (Normal Open Contact) (Option)
{{{
Operation
Automatic Operation — — — Dlll-NET Compatible (Adaptor) (Option)
{{{
Programme Dry Function
{{{
Remote Controller
Wireless
{{{
Fan Only
{{{
Wired ———
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation
{{{
Priority-Room Setting — — —
Cooling / Heating Mode Lock — — —
Home Leave Operation
{{
ECONO Mode
{
——
Indoor Unit On/Off Switch
{{{
Signal Reception Indicator
{{{
Temperature Display — — —
Another Room Operation — — —
Note:
{
: Holding Functions
— : No Functions
Si12-619A List of Functions
List of Functions 5
Category Functions
FDKS25/35CAVMB
FDKS50/60CVMB
Category Functions
FDKS25/35CAVMB
FDKS50/60CVMB
Basic Function
Inverter (with Inverter Power Control) {{Health &
Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB) Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
Compressor Oval Scroll Compressor
Titanium Apatite Photocatalytic Air-Purifying Filter
——
Swing Compressor
Rotary Compressor Mold Proof Air Filter
{{
Reluctance DC Motor Wipe-clean Flat Panel
Comfortable Airflow
Power-Airflow Flap Washable Grille
Power-Airflow Dual Flaps Mold Proof Operation
Power-Airflow Diffuser Heating Dry Operation
Wide-Angle Louvers Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down) Timer 24-Hour On/Off Timer
{{
Horizontal Auto-Swing (Right and Left) Night Set Mode
{{
3-D Airflow Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
{{
Comfort Airflow Mode Self-Diagnosis (Digital, LED) Display
{{
3-Step Airflow (H/P Only) Wiring-Error Check
Comfort Control
Auto Fan Speed
{{
Anticorrosion Treatment of Outdoor Heat Exchanger
——
Indoor Unit Quiet Operation
{{
Night Quiet Mode (Automatic)
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{
Outdoor Unit Quiet Operation (Manual) Flexible Voltage Correspondence
{{
Intelligent Eye High Ceiling Application
Quick Warming Function Chargeless
Hot-Start Function Either Side Drain (Right or Left)
Automatic Defrosting Power-Selection
Operation Automatic Operation Remote
Control
5-Rooms Centralized Controller (Option)
{{
Programme Dry Function
{{
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{
Fan Only
{{
Remote Control Adaptor (Normal Open Contact) (Option)
{{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Dlll-NET Compatible (Adaptor) (Option)
{{
Inverter Powerful Operation
{{
Remote Controller
Wireless
{{
Priority-Room Setting Wired
Cooling / Heating Mode Lock
Home Leave Operation
{{
ECONO Mode
Indoor Unit On/Off Switch
{{
Signal Reception Indicator
{{
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
List of Functions Si12-619A
6 List of Functions
Category Functions
FDKS25/35EAVMB
CDKS25-60CVMA
CDKS25-60DVMT
CDKS25/35EAVMA(T)
Category Functions
FDKS25/35EAVMB
CDKS25-60CVMA
CDKS25-60DVMT
CDKS25/35EAVMA(T)
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB) Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
Titanium Apatite Photocatalytic Air-Purifying Filter
——
Compressor Oval Scroll Compressor Longlife Filter
Swing Compressor Mold Proof Air Filter
{{
Rotary Compressor Wipe-clean Flat Panel
Reluctance DC Motor Washable Grille
Comfortable Airflow
Power-Airflow Flap Mold Proof Operation
Power-Airflow Dual Flaps Heating Dry Operation
Power-Airflow Diffuser Good-Sleep Cooling Operation
Wide-Angle Louvers Timer 24-Hour On/Off Timer
{{
Vertical Auto-Swing (Up and Down) Night Set Mode
{{
Horizontal Auto-Swing (Right and Left) — Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
{{
3-D Airflow Self-Diagnosis (Digital, LED) Display
{{
Comfort Airflow Mode Wiring-Error Check
3-Step Airflow (H/P Only)
Anticorrosion Treatment of Outdoor Heat Exchanger
——
Comfort Control
Auto Fan Speed
{{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
Indoor Unit Quiet Operation
{{
Flexible Voltage Correspondence
{{
Night Quiet Mode (Automatic) High Ceiling Application
Outdoor Unit Quiet Operation (Manual) — Chargeless
Intelligent Eye Either Side Drain (Right or Left)
Quick Warming Function Power-Selection
Hot-Start Function
Remote Control
5-Rooms Centralized Controller (Option)
{{
Automatic Defrosting
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{
Operation
Automatic Operation
Remote Control Adaptor (Normal Open Contact) (Option)
{{
Programme Dry Function
{{
Dlll-NET Compatible (Adaptor) (Option)
{{
Fan Only
{{
Remote Controller
Wireless
{{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
—— Wired ——
Inverter Powerful Operation
{{
Priority-Room Setting
Cooling / Heating Mode Lock
Home Leave Operation
{{
ECONO Mode
Indoor Unit On/Off Switch
{{
Signal Reception Indicator
{{
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
Si12-619A List of Functions
List of Functions 7
Category Functions
FFQ25-60B8V1B
3MKS58EVMA
3MKS75EVMA
4MKS90EVMA
Category Functions
FFQ25-60B8V1B
3MKS58EVMA
3MKS75EVMA
4MKS90EVMA
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB)
10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
{
Titanium Apatite Photocatalytic Air-Purifying Filter
——
Compressor
Oval Scroll Compressor
Longlife Filter (Option)
{
Swing Compressor
{
Mold Proof Air Filter
{
Rotary Compressor
Wipe-clean Flat Panel
Reluctance DC Motor
{
Washable Grille
Comfortable Airflow
Power-Airflow Flap Filter Cleaning Indicator
{
Power-Airflow Dual Flaps Mold Proof Operation
Power-Airflow Diffuser Heating Dry Operation
Wide-Angle Louvers Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down)
{
Timer
24-Hour On/Off Timer
{
Horizontal Auto-Swing (Right and Left) — Night Set Mode
3-D Airflow
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{
Comfort Airflow Mode Self-Diagnosis (Digital, LED) Display
{{
3-Step Airflow (H/P Only) Wiring-Error Check
{
Comfort Control
Auto Fan Speed
Anticorrosion Treatment of Outdoor Heat Exchanger
{
Indoor Unit Quiet Operation
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
Night Quiet Mode (Automatic)
{
Flexible Voltage Correspondence
{
Outdoor Unit Quiet Operation (Manual) —
{
High Ceiling Application
Intelligent Eye Chargeless
{
Quick Warming Function Either Side Drain (Right or Left)
Hot-Start Function Power-Selection
Automatic Defrosting
Remote Control
5-Rooms Centralized Controller (Option)
——
Operation
Automatic Operation
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
——
Programme Dry Function
{
Remote Control Adaptor (Normal Open Contact) (Option)
——
Fan Only
{
Dlll-NET Compatible (Adaptor) (Option)
{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Remote Controller
Wireless
{
Inverter Powerful Operation Wired
{
Priority-Room Setting
{
Cooling / Heating Mode Lock
Home Leave Operation
ECONO Mode
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
: 72-Hour On/Off Timer
List of Functions Si12-619A
8 List of Functions
Category Functions
3MKS90EVLT
4MKS100EVLT
3MKS50DVM
4MKS71DVM
Category Functions
3MKS90EVLT
4MKS100EVLT
3MKS50DVM
4MKS71DVM
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
——
Operation Limit for Cooling (°CDB)
10
~
46
–10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
{{
Compressor Oval Scroll Compressor
Titanium Apatite Photocatalytic Air-Purifying Filter
——
Swing Compressor
{{
Rotary Compressor Mold Proof Air Filter
Reluctance DC Motor
{{
Wipe-clean Flat Panel
Comfortable Airflow
Power-Airflow Flap Washable Grille
Power-Airflow Dual Flaps Mold Proof Operation
Power-Airflow Diffuser Heating Dry Operation
Wide-Angle Louvers Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down) Timer 24-Hour On/Off Timer
Horizontal Auto-Swing (Right and Left) Night Set Mode
3-D Airflow Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
Comfort Airflow Mode Self-Diagnosis (Digital, LED) Display
{{
3-Step Airflow (H/P Only) Wiring-Error Check
{{
Comfort Control
Auto Fan Speed
Anticorrosion Treatment of Outdoor Heat Exchanger
{{
Indoor Unit Quiet Operation
Night Quiet Mode (Automatic)
{{
Flexibility
Multi-Split / Split Type Compatible Indoor Unit
——
Outdoor Unit Quiet Operation (Manual)
{{
Intelligent Eye Flexible Voltage Correspondence
{
Quick Warming Function High Ceiling Application
Hot-Start Function Chargeless
{{
Automatic Defrosting Either Side Drain (Right or Left)
Operation Automatic Operation Power-Selection
{
Programme Dry Function Remote
Control
5-Rooms Centralized Controller (Option)
Fan Only
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
——
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation
Remote Control Adaptor (Normal Open Contact) (Option)
——
Priority-Room Setting
{{
Cooling / Heating Mode Lock Dlll-NET Compatible (Adaptor) (Option)
Home Leave Operation Remote
Controller
Wireless
ECONO Mode Wired
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
Si12-619A List of Functions
List of Functions 9
Category Functions
3MKS50/71ESG
4MKS80ESG
Category Functions
3MKS50/71ESG
4MKS80ESG
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB)
–10
~
46
10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
{{
Compressor Oval Scroll Compressor
Titanium Apatite Photocatalytic Air-Purifying Filter
——
Swing Compressor
{{
Rotary Compressor Mold Proof Air Filter
Reluctance DC Motor
{{
Wipe-clean Flat Panel
Comfortable Airflow
Power-Airflow Flap Washable Grille
Power-Airflow Dual Flaps Mold Proof Operation
Power-Airflow Diffuser Heating Dry Operation
Wide-Angle Louvers Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down) Timer 24-Hour On/Off Timer
Horizontal Auto-Swing (Right and Left) Night Set Mode
3-D Airflow Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
Comfort Airflow Mode Self-Diagnosis (Digital, LED) Display
{{
3-Step Airflow (H/P Only) Wiring-Error Check
{{
Comfort Control
Auto Fan Speed
Anticorrosion Treatment of Outdoor Heat Exchanger
{{
Indoor Unit Quiet Operation
Night Quiet Mode (Automatic)
{{
Flexibility
Multi-Split / Split Type Compatible Indoor Unit
——
Outdoor Unit Quiet Operation (Manual)
{{
Intelligent Eye Flexible Voltage Correspondence
Quick Warming Function High Ceiling Application
Hot-Start Function Chargeless
{{
Automatic Defrosting Either Side Drain (Right or Left)
Operation Automatic Operation Power-Selection
{{
Programme Dry Function Remote
Control
5-Rooms Centralized Controller (Option)
Fan Only
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
——
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation
Remote Control Adaptor (Normal Open Contact) (Option)
——
Priority-Room Setting
{{
Cooling / Heating Mode Lock Dlll-NET Compatible (Adaptor) (Option)
Home Leave Operation Remote
Controller
Wireless
ECONO Mode Wired
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
List of Functions Si12-619A
10 List of Functions
1.2 Heat Pump
Category Functions
FTXS20DVMA
FTXS25/35EVMA
FTXS50-71FVMA
Category Functions
FTXS20DVMA
FTXS25/35EVMA
FTXS50-71FVMA
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
——
Operation Limit for Cooling (°CDB)
——
Photocatalytic Deodorizing Filter
——
Operation Limit for Heating (°CWB)
——
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
——
Titanium Apatite Photocatalytic Air-Purifying Filter
{{
Compressor
Oval Scroll Compressor
——
Longlife Filter (Option)
——
Swing Compressor
——
Mold Proof Air Filter
{{
Rotary Compressor
——
Wipe-clean Flat Panel
{{
Reluctance DC Motor
——
Washable Grille
——
Comfortable Airflow
Power-Airflow Flap
——
Filter Cleaning Indicator
——
Power-Airflow Dual Flaps
{{
Mold Proof Operation
{
Power-Airflow Diffuser
——
Heating Dry Operation
——
Wide-Angle Louvers
{{
Good-Sleep Cooling Operation
——
Vertical Auto-Swing (Up and Down)
{{
Timer
24-Hour On/Off Timer
{{
Horizontal Auto-Swing (Right and Left)
{
Night Set Mode
{{
3-D Airflow
{
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{{
Comfort Airflow Mode
——
Self-Diagnosis (Digital, LED) Display
{{
3-Step Airflow (H/P Only)
——
Wiring-Error Check
——
Comfort Control
Auto Fan Speed
{{
Anticorrosion Treatment of Outdoor Heat Exchanger
——
Indoor Unit Quiet Operation
{{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{
Night Quiet Mode (Automatic)
——
Flexible Voltage Correspondence
{{
Outdoor Unit Quiet Operation (Manual)
——
High Ceiling Application
——
Intelligent Eye
{{
Chargeless
——
Quick Warming Function
——
Either Side Drain (Right or left)
{{
Hot-Start Function
{{
Power-Selection
——
Automatic Defrosting
——
Remote Control
5-Rooms Centralized Controller (Option)
{{
Operation
Automatic Operation
{{
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{
Programme Dry Function
{{
Remote Control Adaptor (Normal Open Contact) (Option)
{{
Fan Only
{{
Dlll-NET Compatible (Adaptor) (Option)
{{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Remote Controller
Wireless
{{
Inverter Powerful Operation
{{
Wired
——
Priority-Room Setting
——
Cooling / Heating Mode Lock
——
Home Leave Operation
{
ECONO Mode
{
Indoor Unit On/Off Switch
{{
Signal Reception Indicator
{{
Temperature Display
——
Another Room Operation
——
Note:
{
: Holding Functions
— : No Functions
Si12-619A List of Functions
List of Functions 11
Category Functions
FTXS20-35DVMT
FTXS50-71DVMT
FTXS50-71FVLT
Category Functions
FTXS20-35DVMT
FTXS50-71DVMT
FTXS50-71FVLT
Basic Function
Inverter (with Inverter Power Control)
{{{
Health & Clean
Air Purifying Filter — — —
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter — — —
Operation Limit for Heating (°CWB) — — —
Air Purifying Filter with Photocatalytic Deodorizing Function
{
PAM Control — — —
Titanium Apatite Photocatalytic Air-Purifying Filter
{
{
Compressor Oval Scroll Compressor — — — Longlife Filter — — —
Swing Compressor — — — Mold Proof Air Filter
{{{
Rotary Compressor — — — Wipe-clean Flat Panel
{{{
Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Mold Proof Operation
{ ——
Power-Airflow Dual Flaps
{{{
Heating Dry Operation — — —
Power-Airflow Diffuser — — — Good-Sleep Cooling Operation — — —
Wide-Angle Louvers
{{{
Timer 24-Hour On/Off Timer
{{{
Vertical Auto-Swing (Up and Down)
{{{
Night Set Mode
{{{
Horizontal Auto-Swing (Right and Left) —
{{
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{{{
3-D Airflow
{{
Self-Diagnosis (Digital, LED) Display
{{{
Comfort Airflow Mode — — — Wiring-Error Check — — —
3-Step Airflow (H/P Only) — — —
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Comfort Control
Auto Fan Speed
{{{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{{
Indoor Unit Quiet Operation
{{{
Flexible Voltage Correspondence
{{
Night Quiet Mode (Automatic) — — — High Ceiling Application — — —
Outdoor Unit Quiet Operation (Manual) — — — Chargeless — — —
Intelligent Eye
{{{
Either Side Drain (Right or Left)
{{{
Quick Warming Function ——— Power-Selection ———
Hot-Start Function
{{{
Remote Control
5-Rooms Centralized Controller (Option)
{{{
Automatic Defrosting — — —
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{{
Operation
Automatic Operation
{{{
Remote Control Adaptor (Normal Open Contact) (Option)
{{{
Programme Dry Function
{{{
Dlll-NET Compatible (Adaptor) (Option)
{{{
Fan Only
{{{
Remote Controller
Wireless
{{{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——— Wired ———
Inverter Powerful Operation
{{{
Priority-Room Setting — — —
Cooling / Heating Mode Lock — — —
Home Leave Operation
{{
ECONO Mode
{
——
Indoor Unit On/Off Switch
{{{
Signal Reception Indicator
{{{
Temperature Display — — —
Another Room Operation — — —
Note:
{
: Holding Functions
— : No Functions
List of Functions Si12-619A
12 List of Functions
Category Functions
FDXS25-60CVMA
CDXS25-60DVMT
Category Functions
FDXS25-60CVMA
CDXS25-60DVMT
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB)
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
——
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
Titanium Apatite Photocatalytic Air-Purifying Filter
Compressor Oval Scroll Compressor
——
Longlife Filter (Option)
——
Swing Compressor
——
Mold Proof Air Filter
{
{
Rotary Compressor
——
Wipe-clean Flat Panel
——
Reluctance DC Motor
——
Washable Grille
Comfortable Airflow
Power-Airflow Flap
——
Mold Proof Operation
Power-Airflow Dual Flaps Heating Dry Operation
Power-Airflow Diffuser
——
Good-Sleep Cooling Operation
Wide-Angle Louvers
——
Timer 24-Hour On/Off Timer
{
{
Vertical Auto-Swing (Up and Down)
——
Night Set Mode
{
{
Horizontal Auto-Swing (Right and Left)
——
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{
{
3-D Airflow
——
Self-Diagnosis (Digital, LED) Display
{
{
Comfort Airflow Mode Wiring-Error Check
3-Step Airflow (H/P Only)
——
Anticorrosion Treatment of Outdoor Heat Exchanger
Comfort Control
Auto Fan Speed
{{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
Indoor Unit Quiet Operation
{{
Flexible Voltage Correspondence
{
{
Night Quiet Mode (Automatic) High Ceiling Application
Outdoor Unit Quiet Operation (Manual)
——
Chargeless
Intelligent Eye Either Side Drain (Right or left)
Quick Warming Function
——
Power-Selection
Hot-Start Function
{{
Remote Control
5-Rooms Centralized Controller (Option)
{
{
Automatic Defrosting
——
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{
{
Operation
Automatic Operation
{{
Remote Control Adaptor (Normal Open Contact) (Option)
{
{
Programme Dry Function
{{
Dlll-NET Compatible (Adaptor) (Option)
{
{
Fan Only
{{
Remote Controller
Wireless
{
{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Wired
Inverter Powerful Operation
{{
Priority-Room Setting
——
Cooling / Heating Mode Lock
——
Home Leave Operation
{{
ECONO Mode
——
Indoor Unit On/Off Switch
{{
Signal Reception Indicator
{{
Temperature Display
——
Another Room Operation
——
Note:
{
: Holding Functions
— : No Functions
Si12-619A List of Functions
List of Functions 13
Category Functions
CDXS25/35EAVMA(T)
Category Functions
CDXS25/35EAVMA(T)
Basic Function
Inverter (with Inverter Power Control)
{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB)
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
PAM Control
Titanium Apatite Photocatalytic Air-Purifying Filter
Compressor Oval Scroll Compressor
Longlife Filter (Option)
Swing Compressor
Mold Proof Air Filter
{
Rotary Compressor
Wipe-clean Flat Panel
Reluctance DC Motor
Washable Grille
Comfortable Airflow
Power-Airflow Flap
Filter Cleaning Indicator
Power-Airflow Dual Flaps
Mold Proof Operation
Power-Airflow Diffuser
Heating Dry Operation
Wide-Angle Louvers
Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down)
Timer 24-Hour On/Off Timer
{
Horizontal Auto-Swing (Right and Left)
Night Set Mode
{
3-D Airflow
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{
Comfort Airflow Mode
Self-Diagnosis (Digital, LED) Display
{
3-Step Airflow (H/P Only)
Wiring-Error Check
Comfort Control
Auto Fan Speed
{
Anticorrosion Treatment of Outdoor Heat Exchanger
Indoor Unit Quiet Operation
{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
Night Quiet Mode (Automatic)
Flexible Voltage Correspondence
{
Outdoor Unit Quiet Operation (Manual)
High Ceiling Application
Intelligent Eye
Chargeless
Quick Warming Function
Either Side Drain (Right or left)
Hot-Start Function
{
Power-Selection
Automatic Defrosting
Remote Control
5-Rooms Centralized Controller (Option)
{
Operation
Automatic Operation
{
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{
Programme Dry Function
{
Remote Control Adaptor (Normal Open Contact) (Option)
{
Fan Only
{
Dlll-NET Compatible (Adaptor) (Option)
{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Remote Controller
Wireless
{
Inverter Powerful Operation
{
Wired
Priority-Room Setting
Cooling / Heating Mode Lock
Home Leave Operation
{
ECONO Mode
Indoor Unit On/Off Switch
{
Signal Reception Indicator
{
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
List of Functions Si12-619A
14 List of Functions
Category Functions
FLXS25-60BVMA
FVXS35/50BVMA
FFQ25-60B8V1B
Category Functions
FLXS25-60BVMA
FVXS35/50BVMA
FFQ25-60B8V1B
Basic Function
Inverter (with Inverter Power Control)
{{{
Health & Clean
Air Purifying Filter
{{
Operation Limit for Cooling (°CDB) — — —
Photocatalytic Deodorizing Filter
{{
Operation Limit for Heating (°CWB) — — —
Air Purifying Filter with Photocatalytic Deodorizing Function
———
PAM Control — — —
Titanium Apatite Photocatalytic Air-Purifying Filter
———
Compressor Oval Scroll Compressor
———
Longlife Filter (Option)
——
{
Swing Compressor
———
Mold Proof Air Filter
{{{
Rotary Compressor — — — Wipe-clean Flat Panel — — —
Reluctance DC Motor
———
Washable Grille
{
Comfortable Airflow
Power-Airflow Flap
{{
Filter Cleaning Indicator
——
{
Power-Airflow Dual Flaps — — — Mold Proof Operation — — —
Power-Airflow Diffuser — — — Heating Dry Operation — — —
Wide-Angle Louvers
{
Good-Sleep Cooling Operation
———
Vertical Auto-Swing (Up and Down)
{{{
Timer
24-Hour On/Off Timer
{{
{
Horizontal Auto-Swing (Right and Left)
———
Night Set Mode
{{
3-D Airflow
———
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
{{{
Comfort Airflow Mode
———
Self-Diagnosis (Digital, LED) Display
{{{
3-Step Airflow (H/P Only)
{
Wiring-Error Check
———
Comfort Control
Auto Fan Speed
{{
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Indoor Unit Quiet Operation
{{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{{
Night Quiet Mode (Automatic)
———
Flexible Voltage Correspondence
{{
Outdoor Unit Quiet Operation (Manual) — — — High Ceiling Application — — —
Intelligent Eye — — — Chargeless — — —
Quick Warming Function
———
Either Side Drain (Right or Left)
{
Hot-Start Function
{{{
Power-Selection
———
Automatic Defrosting — — —
Remote Control
5-Rooms Centralized Controller (Option)
{{
Operation
Automatic Operation
{{{
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
{{
Programme Dry Function
{{{
Remote Control Adaptor (Normal Open Contact) (Option)
{{
Fan Only
{{{
Dlll-NET Compatible (Adaptor) (Option)
{{{
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Remote Controller
Wireless
{{{
Inverter Powerful Operation
{{
Wired
——
{
Priority-Room Setting
———
Cooling / Heating Mode Lock
———
Home Leave Operation
{{
ECONO Mode
———
Indoor Unit On/Off Switch
{{
Signal Reception Indicator
{{
Temperature Display
———
Another Room Operation
———
Note:
{
: Holding Functions
— : No Functions
: 72-Hour On/Off Timer
Si12-619A List of Functions
List of Functions 15
Category Functions
3MXS52EVMA
3MXS68EVMA
4MXS80EVMA
Category Functions
3MXS52EVMA
3MXS68EVMA
4MXS80EVMA
Basic Function
Inverter (with Inverter Power Control)
{{
Health & Clean
Air Purifying Filter
——
Operation Limit for Cooling (°CDB)
–5
~
46
–10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
–15
~
15.5
–15
~
15.5
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control
{{
Titanium Apatite Photocatalytic Air-Purifying Filter
——
Compressor Oval Scroll Compressor Longlife Filter (Option)
Swing Compressor
{{
Mould Proof Air Filter
——
Rotary Compressor Wipe-clean Flat Panel
Reluctance DC Motor
{{
Washable Grille
——
Comfortable Airflow
Power-Airflow Flap Filter Cleaning Indicator
Power-Airflow Dual Flaps Mold Proof Operation
Power-Airflow Diffuser Heating Dry Operation
Wide-Angle Louvers Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down) Timer 24-Hour On/Off Timer
Horizontal Auto-Swing (Right and Left) Night Set Mode
3-D Airflow Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
Comfort Airflow Mode
——
Self-Diagnosis (Digital, LED) Display
{{
3-Step Airflow (H/P Only)
——
Wiring-Error Check
{{
Comfort Control
Auto Fan Speed
Anticorrosion Treatment of Outdoor Heat Exchanger
{{
Indoor Unit Quiet Operation
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
——
Night Quiet Mode (Automatic)
{{
Flexible Voltage Correspondence
{{
Outdoor Unit Quiet Operation (Manual)
{{
High Ceiling Application
——
Intelligent Eye Chargeless 30m 40m
Quick Warming Function
{{
Either Side Drain (Right or Left)
——
Hot-Start Function Power-Selection
Automatic Defrosting
{{
Remote Control
5-Rooms Centralized Controller (Option)
——
Operation
Automatic Operation
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
——
Programme Dry Function
Remote Control Adaptor (Normal Open Contact) (Option)
——
Fan Only
Dlll-NET Compatible (Adaptor) (Option)
——
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Remote Controller
Wireless
Inverter Powerful Operation Wired
Priority-Room Setting
{{
Cooling / Heating Mode Lock
{{
Home Leave Operation
——
ECONO Mode
——
Indoor Unit On/Off Switch
——
Signal Reception Indicator
——
Temperature Display
——
Another Room Operation
——
Note:
{
: Holding Functions
— : No Functions
List of Functions Si12-619A
16 List of Functions
Category Functions
3MXS90EVLT
4MXS100EVLT
Category Functions
3MXS90EVLT
4MXS100EVLT
Basic Function
Inverter (with Inverter Power Control)
{
Health & Clean
Air Purifying Filter
Operation Limit for Cooling (°CDB)
–10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
–15
~
15.5
Air Purifying Filter with Photocatalytic Deodorizing Function
PAM Control
{
Titanium Apatite Photocatalytic Air-Purifying Filter
Compressor Oval Scroll Compressor Longlife Filter
Swing Compressor
{
Mold Proof Air Filter
Rotary Compressor Wipe-clean Flat Panel
Reluctance DC Motor
{
Washable Grille
Comfortable Airflow
Power-Airflow Flap Mold Proof Operation
Power-Airflow Dual Flaps Heating Dry Operation
Power-Airflow Diffuser Good-Sleep Cooling Operation
Wide-Angle Louvers Timer 24-Hour On/Off Timer
Vertical Auto-Swing (Up and Down) Night Set Mode
Horizontal Auto-Swing (Right and Left) Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure)
3-D Airflow Self-Diagnosis (Digital, LED) Display
{
Comfort Airflow Mode Wiring-Error Check
{
3-Step Airflow (H/P Only)
Anticorrosion Treatment of Outdoor Heat Exchanger
{
Comfort Control
Auto Fan Speed
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
Indoor Unit Quiet Operation Flexible Voltage Correspondence
Night Quiet Mode (Automatic)
{
High Ceiling Application
Outdoor Unit Quiet Operation (Manual)
{
Chargeless 40m
Intelligent Eye Either Side Drain (Right or Left)
Quick Warming Function
{
Power-Selection
Hot-Start Function
Remote Control
5-Rooms Centralized Controller (Option)
Automatic Defrosting
{
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
Operation
Automatic Operation
Remote Control Adaptor (Normal Open Contact) (Option)
Programme Dry Function Dlll-NET Compatible (Adaptor) (Option)
Fan Only Remote
Controller
Wireless
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
—Wired
Inverter Powerful Operation
Priority-Room Setting
{
Cooling / Heating Mode Lock
{
Home Leave Operation
ECONO Mode
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
— : No Functions
Si12-619A
Specifications 17
Part 2
Specifications
1. Specifications........................................................................................18
1.1 Indoor Units - Cooling Only ....................................................................18
1.2 Outdoor Units - Cooling Only .................................................................32
1.3 Indoor Units - Heat Pump .......................................................................38
1.4 Outdoor Units - Heat Pump ....................................................................48
Loading...
+ 373 hidden pages