Daikin D2CND024A1AA, D2CND024A4AA, D2TND012A4AA, D2TND018A4AA, D2TND024A4AA Operation manuals

Operation manual
Wall-mounted condensing boiler
D2CND024A1AA D2CND024A4AA               D2TND012A4AA D2TND018A4AA D2TND024A4AA
Operation manual
Wall-mounted condensing boiler
English

Table of Contents

Table of Contents

1 Introduction 2

1.1 About the unit ............................................................................ 2
1.2 About the documentation .......................................................... 2
1.2.1 Meaning of warnings and symbols.............................. 2

2 Safety instructions 2

2.1 Installation ................................................................................. 2
2.2 Smell of gas............................................................................... 3
2.3 Modifications on the unit............................................................ 3
2.4 Gas conversion ......................................................................... 3
2.5 For the user ............................................................................... 3
3 Operation 3
3.1 User interface ............................................................................ 3
3.1.1 Buttons and dials ........................................................ 4
3.1.2 LCD screen ................................................................. 4
3.1.3 Status indicator ........................................................... 4
3.2 Operating the unit...................................................................... 4
3.2.1 To switch ON the unit.................................................. 4
3.2.2 About the low water temperature function .................. 4
3.2.3 About the electronic gas adaptive system calibration. 4
3.3 Basic usage............................................................................... 4
3.3.1 About the home screen............................................... 4
3.3.2 To select the operation mode ..................................... 5
3.3.3 Possible operation modes........................................... 5
3.3.4 Changing temperature setpoints................................. 5
3.3.5 Possible central heating operation modes.................. 6
3.3.6 About the central heating ECO mode ......................... 6
3.3.7 About the domestic hot water operation ..................... 6
3.3.8 About the domestic hot water comfort mode .............. 7
3.3.9 About the boiler frost protection.................................. 7
3.4 Error handling............................................................................ 7
3.5 Menu functions .......................................................................... 7
3.5.1 To use menu level 1.................................................... 7
3.5.2 Info menu .................................................................... 7
3.5.3 User settings menu ..................................................... 8
3.5.4 Installer settings menu ................................................ 9
4 Maintenance and cleaning 9
4.1 To clean the outer surface of the unit........................................ 9
5 Energy saving tips 9
6 Contact 9
7 Error codes 9
1 Introduction
Model Type Domestic hot water
supply
D2TND012A4AA D2TND012 Storage tank External
D2TND018A4AA D2TND018 Storage tank External
D2TND024A4AA D2TND024 Storage tank External
A control unit, which contains a user interface, controls the ignition, safety systems, and other actuators. User interaction is provided via that user interface, which is composed of an LCD screen, push buttons, and two dials, and which is located on the front cover of the unit.
Filling loop

1.2 About the documentation

The instructions contained in this document are intended to guide you through the operation of the unit. Damage caused by non­observance of these instructions are not under the responsibility of Daikin.
▪ The original documentation is written in English. All other
languages are translations.
▪ The precautions described in this document are written for users
and cover very important topics, follow them carefully.
▪ Please read the instructions in the manual carefully, for your
safety and health.
▪ Please keep this manual for future reference throughout the unit's
period of use.
▪ Request the installer to inform you about the settings that he
made to configure your system.

1.2.1 Meaning of warnings and symbols

DANGER
Indicates a situation that results in death or serious injury.
WARNING
Indicates a situation that could result in death or serious injury.
CAUTION
Indicates a situation that could result in minor or moderate injury.
NOTICE
Indicates a situation that could result in equipment or property damage.
INFORMATION
Indicates useful tips or additional information.

1.1 About the unit

This Daikin unit is a wall-mounted gas-fired condensing boiler that can supply heat to central heating systems, as well as supply domestic hot water. Depending on settings, it is possible to use the unit solely for hot water or solely for central heating. Hot water supply type can be instantaneous or by means of a hot water storage tank. The type of the boiler can be recognised from the model name written on the identification label, which is located at the right cover of the unit. See table below:
Model Type Domestic hot water
supply
D2CND024A1AA D2CND024 Instantaneous Internal
D2CND024A4AA D2CND024 Instantaneous External
Operation manual
Filling loop
2
2 Safety instructions
Always observe the following safety instructions and regulations.

2.1 Installation

WARNING
Installation, service, maintenance and repair of the boiler can only be carried out by suitably qualified competent persons, in accordance with the applicable legislation, regulations, rules and guidelines.
D2CND024A1/4AA + D2TND012~024A4AA
Wall-mounted condensing boiler
3P469438-3D – 2017.07

3 Operation

a
e f g
cb
d
WARNING
The unit may only be operated with its casing properly mounted. Otherwise, in unfavourable conditions, material damage or even injury or death can result.
CAUTION
A discharge pipe must be connected to the condensate trap in order to prevent contact with the condensate.
In case your skin comes into contact with condensate, the contact location should be washed with plenty of water. Condensate liquid must never be used for purposes of cleaning, watering plants, or drinking.

2.2 Smell of gas

DANGER
This is a gas unit. Gas leaks might lead to poisoning and explosions.
If you smell gas:
▪ Do not use any electrical switches, including light switches.
▪ Do not use telephones in the affected area.
▪ Do not use naked flames, such as matches or lighters.
▪ Do not smoke.
▪ Turn off the main gas supply.
▪ Open windows and doors.
▪ Warn other people in the building.
▪ Get out of the building.
▪ Inform your gas supplier, service agent or other competent
person.

2.3 Modifications on the unit

DANGER
Malfunctions can lead to poisoning and explosions. Never put the safety devices out of operation, nor tamper with them so as to impair their function.

2.4 Gas conversion

WARNING
Never attempt to do gas conversion yourself. Only qualified persons can do gas conversion. Contact your service agent.
This unit is able to be operated with both natural gas and LPG. The preset gas type is indicated on the identification label of your unit. If you desire to use your unit with the other fuel type, contact your service agent.

2.5 For the user

CAUTION
Any misuse is forbidden. The manufacturer is not responsible for any malfunctions and/or damage that may occur due to misuse.
▪ Your unit is intended as a heater for central heating systems and
for domestic hot water generation. Any other use is considered as "misuse".
▪ If you are not sure how to operate the unit, contact your service
agent.
▪ This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
CAUTION
Do not rinse the unit. This may cause electric shocks or fire.
NOTICE
▪ Do not place any objects or equipment on top of the
unit.
▪ Do not sit, climb or stand on the unit.
CAUTION
An inappropriate modification may cause damage. Never tamper with the boiler or other parts of the system. Never attempt to perform maintenance or repair yourself. Call a qualified service agent.
CAUTION
Do not use sprays, solvents, chlorinated cleaning agents, paint, and adhesives in the vicinity of the unit. These substances can cause corrosion, even in the flue system.
DANGER
Do not damage or remove any seals on components. Only qualified persons are allowed to alter sealed components.
Do not make any modifications on:
▪ Boiler
▪ Gas, water or power supply
▪ Flue system
D2CND024A1/4AA + D2TND012~024A4AA Wall-mounted condensing boiler 3P469438-3D – 2017.07
3 Operation

3.1 User interface

a Left dial b LCD screen c Right dial
Operation manual
3
3 Operation
d Mode / Reset e Status indicator
f Cancel / Back
g Menu / Enter

3.1.1 Buttons and dials

The three buttons and two dials on the user interface have various functions according to different situations, which are stated in the table below:
Button/Dial Function Description
Mode / Reset
Cancel / Back
Menu / Enter Menu Enter the menu function.
Left dial User
Right dial User
Mode Change mode between summer,
winter, central heating only, standby and full-off.
Reset Reset the lockout error.
Cancel Cancel changes.
Back Go back to the parent menu.
Enter Passing on to the next level in the
menu structure.
Confirm Confirmation of changes.
Central heating temperature setpoint. interaction level
Menu level Selection of info, user, service menu.
interaction level
Menu level ▪ Selection parameter index.
This is either the central heating flow
temperature, the room temperature,
or the virtual room temperature,
depending on the system
configuration.
Domestic hot water temperature
setpoint.
▪ Change parameter values.

3.1.2 LCD screen

LCD screen is the monitor of the user interface. You can see the boiler operation mode, setpoints, information about actuators and menu parameters on this screen.
The LCD screen has a sleeping function. After one minute of non­interaction with the user interface, the screen darkens. Pressing any button or rotating any dial awakens the display.
When you interact with the user interface, the LCD screen will show the home screen of the active operation mode and the related setpoint, depending on the system configuration (see "3.3.3Possible
operation modes"on page5).
Status icons
Meaning of icons that appear on the LCD screen:
Icon Description
Operation mode: Standby mode
Domestic hot water operation enabled
Domestic hot water comfort mode is enabled
Central heating operation enabled
Room temperature
Outdoor sensor connection
Central heating ECO mode enabled
Network connection
Info menu
User settings menu
Icon Description
Service settings menu

3.1.3 Status indicator

The status indicator gives first level feedback on the operation mode and status of the boiler.
Status Description
Standby When there is no heat demand, the status
indicator shows this with a kind of breathing pulsation of the blue and white LED.
Flame At the moment flame ignites for central heating or
domestic hot water, the ring flashes to its maximum, then constantly keeps glowing during burner operation.
Error The status indicator will go into error mode when a
warning, lockout or blocking error occurs (see
"3.4Error handling"on page7). During the error
condition the status indicator continuously shows the red blinking LED.
NOTICE
In warning error, the status indicator colour turns to blue while the boiler is operating.

3.2 Operating the unit

3.2.1 To switch ON the unit

1 Connect the unit to the main power supply.
2 Press the "Mode" button for 5seconds to switch ON the unit.
3 After that, you can select an operation mode by pressing the
"Mode" button shortly.
Use of the unit is explained in following parts of this manual.

3.2.2 About the low water temperature function

The low water temperature function is a safety function that takes place at first central heating operation after each power supply interruption and at first central heating operation after each 90 days. When this function is active, boiler operates according to a defined set value for around 15 minutes and the icon blinks. After this function is ended, normal operation goes on.
INFORMATION
Low water temperature function is a safety function and it cannot be disabled.

3.2.3 About the electronic gas adaptive system calibration

The electronic gas adaptive system calibrates itself in pre­determined time intervals. First calibration takes place just after first burner activation after each power ON. Calibration process duration is around 60 seconds and the icon blinks. After calibration is ended, boiler modulates to required capacity. Calibration process has no effect on boiler operation.

3.3 Basic usage

3.3.1 About the home screen

It is the screen that is displayed after activating the LCD screen with one of the dials or buttons. You can use the home screen to read out settings that are meant for daily use. What you can see on the home screen depends on your system configuration.
Operation manual
4
D2CND024A1/4AA + D2TND012~024A4AA
Wall-mounted condensing boiler
3P469438-3D – 2017.07
Loading...