3.5.1To use menu level 1.................................................... 7
3.5.2Info menu .................................................................... 7
3.5.3User settings menu ..................................................... 8
3.5.4Installer settings menu ................................................ 9
4 Maintenance and cleaning9
4.1To clean the outer surface of the unit........................................9
5 Energy saving tips9
6 Contact9
7 Error codes9
1Introduction
ModelTypeDomestic hot water
supply
D2TND012A4AA D2TND012Storage tankExternal
D2TND018A4AA D2TND018Storage tankExternal
D2TND024A4AA D2TND024Storage tankExternal
A control unit, which contains a user interface, controls the ignition,
safety systems, and other actuators. User interaction is provided via
that user interface, which is composed of an LCD screen, push
buttons, and two dials, and which is located on the front cover of the
unit.
Filling loop
1.2About the documentation
The instructions contained in this document are intended to guide
you through the operation of the unit. Damage caused by nonobservance of these instructions are not under the responsibility of
Daikin.
▪ The original documentation is written in English. All other
languages are translations.
▪ The precautions described in this document are written for users
and cover very important topics, follow them carefully.
▪ Please read the instructions in the manual carefully, for your
safety and health.
▪ Please keep this manual for future reference throughout the unit's
period of use.
▪ Request the installer to inform you about the settings that he
made to configure your system.
1.2.1Meaning of warnings and symbols
DANGER
Indicates a situation that results in death or serious injury.
WARNING
Indicates a situation that could result in death or serious
injury.
CAUTION
Indicates a situation that could result in minor or moderate
injury.
NOTICE
Indicates a situation that could result in equipment or
property damage.
INFORMATION
Indicates useful tips or additional information.
1.1About the unit
This Daikin unit is a wall-mounted gas-fired condensing boiler that
can supply heat to central heating systems, as well as supply
domestic hot water. Depending on settings, it is possible to use the
unit solely for hot water or solely for central heating. Hot water
supply type can be instantaneous or by means of a hot water
storage tank. The type of the boiler can be recognised from the
model name written on the identification label, which is located at the
right cover of the unit. See table below:
ModelTypeDomestic hot water
supply
D2CND024A1AA D2CND024InstantaneousInternal
D2CND024A4AA D2CND024InstantaneousExternal
Operation manual
Filling loop
2
2Safety instructions
Always observe the following safety instructions and regulations.
2.1Installation
WARNING
Installation, service, maintenance and repair of the boiler
can only be carried out by suitably qualified competent
persons, in accordance with the applicable legislation,
regulations, rules and guidelines.
D2CND024A1/4AA + D2TND012~024A4AA
Wall-mounted condensing boiler
3P469438-3D – 2017.07
3 Operation
a
efg
cb
d
WARNING
The unit may only be operated with its casing properly
mounted. Otherwise, in unfavourable conditions, material
damage or even injury or death can result.
CAUTION
A discharge pipe must be connected to the condensate
trap in order to prevent contact with the condensate.
In case your skin comes into contact with condensate, the contact
location should be washed with plenty of water. Condensate liquid
must never be used for purposes of cleaning, watering plants, or
drinking.
2.2Smell of gas
DANGER
This is a gas unit. Gas leaks might lead to poisoning and
explosions.
If you smell gas:
▪ Do not use any electrical switches, including light switches.
▪ Do not use telephones in the affected area.
▪ Do not use naked flames, such as matches or lighters.
▪ Do not smoke.
▪ Turn off the main gas supply.
▪ Open windows and doors.
▪ Warn other people in the building.
▪ Get out of the building.
▪ Inform your gas supplier, service agent or other competent
person.
2.3Modifications on the unit
DANGER
Malfunctions can lead to poisoning and explosions. Never
put the safety devices out of operation, nor tamper with
them so as to impair their function.
2.4Gas conversion
WARNING
Never attempt to do gas conversion yourself. Only qualified
persons can do gas conversion. Contact your service
agent.
This unit is able to be operated with both natural gas and LPG. The
preset gas type is indicated on the identification label of your unit. If
you desire to use your unit with the other fuel type, contact your
service agent.
2.5For the user
CAUTION
Any misuse is forbidden. The manufacturer is not
responsible for any malfunctions and/or damage that may
occur due to misuse.
▪ Your unit is intended as a heater for central heating systems and
for domestic hot water generation. Any other use is considered as
"misuse".
▪ If you are not sure how to operate the unit, contact your service
agent.
▪ This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
CAUTION
Do not rinse the unit. This may cause electric shocks or
fire.
NOTICE
▪ Do not place any objects or equipment on top of the
unit.
▪ Do not sit, climb or stand on the unit.
CAUTION
An inappropriate modification may cause damage. Never
tamper with the boiler or other parts of the system. Never
attempt to perform maintenance or repair yourself. Call a
qualified service agent.
CAUTION
Do not use sprays, solvents, chlorinated cleaning agents,
paint, and adhesives in the vicinity of the unit. These
substances can cause corrosion, even in the flue system.
DANGER
Do not damage or remove any seals on components. Only
qualified persons are allowed to alter sealed components.
The three buttons and two dials on the user interface have various
functions according to different situations, which are stated in the
table below:
Button/DialFunctionDescription
Mode /
Reset
Cancel /
Back
Menu / Enter MenuEnter the menu function.
Left dialUser
Right dialUser
ModeChange mode between summer,
winter, central heating only, standby
and full-off.
ResetReset the lockout error.
CancelCancel changes.
BackGo back to the parent menu.
EnterPassing on to the next level in the
menu structure.
ConfirmConfirmation of changes.
Central heating temperature setpoint.
interaction
level
Menu levelSelection of info, user, service menu.
interaction
level
Menu level▪ Selection parameter index.
This is either the central heating flow
temperature, the room temperature,
or the virtual room temperature,
depending on the system
configuration.
Domestic hot water temperature
setpoint.
▪ Change parameter values.
3.1.2LCD screen
LCD screen is the monitor of the user interface. You can see the
boiler operation mode, setpoints, information about actuators and
menu parameters on this screen.
The LCD screen has a sleeping function. After one minute of noninteraction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.
When you interact with the user interface, the LCD screen will show
the home screen of the active operation mode and the related
setpoint, depending on the system configuration (see "3.3.3Possible
operation modes"on page5).
Status icons
Meaning of icons that appear on the LCD screen:
IconDescription
Operation mode: Standby mode
Domestic hot water operation enabled
Domestic hot water comfort mode is enabled
Central heating operation enabled
Room temperature
Outdoor sensor connection
Central heating ECO mode enabled
Network connection
Info menu
User settings menu
IconDescription
Service settings menu
3.1.3Status indicator
The status indicator gives first level feedback on the operation mode
and status of the boiler.
StatusDescription
StandbyWhen there is no heat demand, the status
indicator shows this with a kind of breathing
pulsation of the blue and white LED.
FlameAt the moment flame ignites for central heating or
domestic hot water, the ring flashes to its
maximum, then constantly keeps glowing during
burner operation.
ErrorThe status indicator will go into error mode when a
warning, lockout or blocking error occurs (see
"3.4Error handling"on page7). During the error
condition the status indicator continuously shows
the red blinking LED.
NOTICE
In warning error, the status indicator colour turns to blue
while the boiler is operating.
3.2Operating the unit
3.2.1To switch ON the unit
1 Connect the unit to the main power supply.
2 Press the "Mode" button for 5seconds to switch ON the unit.
3 After that, you can select an operation mode by pressing the
"Mode" button shortly.
Use of the unit is explained in following parts of this manual.
3.2.2About the low water temperature function
The low water temperature function is a safety function that takes
place at first central heating operation after each power supply
interruption and at first central heating operation after each 90 days.
When this function is active, boiler operates according to a defined
set value for around 15 minutes and the icon blinks. After this
function is ended, normal operation goes on.
INFORMATION
Low water temperature function is a safety function and it
cannot be disabled.
3.2.3About the electronic gas adaptive system
calibration
The electronic gas adaptive system calibrates itself in predetermined time intervals. First calibration takes place just after first
burner activation after each power ON. Calibration process duration
is around 60 seconds and the icon blinks. After calibration is
ended, boiler modulates to required capacity. Calibration process
has no effect on boiler operation.
3.3Basic usage
3.3.1About the home screen
It is the screen that is displayed after activating the LCD screen with
one of the dials or buttons. You can use the home screen to read out
settings that are meant for daily use. What you can see on the home
screen depends on your system configuration.
Operation manual
4
D2CND024A1/4AA + D2TND012~024A4AA
Wall-mounted condensing boiler
3P469438-3D – 2017.07
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.