Daikin D2CNL024A1AA Operation manuals [sr]

Operation manual
Wall-mounted condensing boiler
D2CNL024A1AA
Operation manual
Wall-mounted condensing boiler
srpski

Table of contents

Table of contents

1 Introduction 2

1.1 About the unit ............................................................................ 2
1.2 About the documentation .......................................................... 2
1.2.1 Meaning of warnings and symbols.............................. 2

2 Safety instructions 2

2.1 Installation ................................................................................. 2
2.2 Smell of gas............................................................................... 3
2.3 Modifications on the unit............................................................ 3
2.4 For the user ............................................................................... 3
3 Operacije 3
3.1 User interface ............................................................................ 3
3.1.1 Buttons........................................................................ 3
3.1.2 LCD screen................................................................. 4
3.2 Operating the unit...................................................................... 4
3.2.1 To switch the unit ON.................................................. 4
3.2.2 About the low water temperature function .................. 4
3.3 Osnovna upotreba..................................................................... 4
3.3.1 About the home screen............................................... 4
3.3.2 To select the operation mode ..................................... 4
3.3.3 Possible operation modes........................................... 4
3.3.4 Changing temperature setpoints................................. 5
3.3.5 Possible central heating operation modes.................. 6
3.3.6 About the central heating ECO mode ......................... 6
3.3.7 About the domestic hot water operation ..................... 6
3.3.8 About the domestic hot water comfort mode .............. 6
3.3.9 About the boiler frost protection.................................. 6
3.4 Error handling............................................................................ 6
3.5 Menu functions .......................................................................... 7
3.5.1 To use menu level 1.................................................... 7
3.5.2 Info menu.................................................................... 7
3.5.3 User settings menu..................................................... 7
3.5.4 Installer settings menu................................................ 8
4 Maintenance and cleaning 8
4.1 To clean the outer surface of the unit........................................ 8

1.2 About the documentation

The instructions contained in this document are intended to guide you through the operation of the unit. Damage caused by non­observance of these instructions are not under the responsibility of Daikin.
▪ Originalna dokumentacija je napisana na engleskom jeziku. Svi
drugi jezici su prevodi.
▪ The precautions described in this document are written for users
and cover very important topics, follow them carefully.
▪ Please read the instructions in the manual carefully, for your
safety and health.
▪ Please keep this manual for future reference throughout the unit's
period of use.
▪ Request the installer to inform you about the settings that he
made to configure your system.

1.2.1 Meaning of warnings and symbols

OPASNOST
Ukazuje na situaciju koja dovodi do smrti ili teške povrede.
UPOZORENJE
Ukazuje na situaciju koja može da dovede do smrti ili teške povrede.
OPREZ
Ukazuje na situaciju koja može da dovede do manje ili umerene povrede.
OBAVEŠTENJE
Ukazuje na situaciju koja može da dovede do oštećenja opreme ili imovine.
INFORMACIJA
Ukazuje na korisne savete ili dodatne informacije.
5 Energy saving tips 8 6 Contact 8 7 Error codes 8
1 Introduction

1.1 About the unit

This Daikin unit is a wall-mounted gas-fired condensing boiler that can supply heat to central heating systems, as well as supply domestic hot water. Depending on settings, it is possible to use the unit solely for hot water or solely for central heating. Hot water supply type can be instantaneous or by means of a hot water storage tank. Heating only boilers do not supply domestic hot water. The type of the boiler can be recognized from the model name written on the identification label. See table below:
Model Type Domestic hot water
supply
D2CNL024A1AA D2CNL024 Instantaneous Internal
A control unit, which contains a user interface, controls the ignition, safety systems, and other actuators. User interaction is provided via that user interface, which is composed of an LCD screen and buttons which is located on the front cover of the unit.
Filling loop
2 Safety instructions
Always observe the following safety instructions and regulations.

2.1 Installation

UPOZORENJE
Installation, service, maintenance and repair of the boiler can only be carried out by suitably qualified competent persons, in accordance with the applicable legislation, regulations, rules and guidelines.
UPOZORENJE
The unit may only be operated with its casing properly mounted. Otherwise, in unfavourable conditions, material damage or even injury or death can result.
OPREZ
A discharge pipe must be connected to the condensate trap in order to prevent contact with the condensate.
In case your skin comes into contact with condensate, the contact location should be washed with plenty of water. Condensate liquid may NEVER be used for purposes of cleaning, watering plants, or drinking.
Operation manual
Wall-mounted condensing boiler
D2CNL024A1AA
3P469438-12N – 2020.07

3 Operacije

a
g
b
c d
e
f

2.2 Smell of gas

OPASNOST
This is a gas unit. Gas leaks might lead to poisoning and explosions.
If you smell gas: ▪ Do not use any electrical switches, including light switches. ▪ Do not use telephones in the affected area. ▪ Do not use naked flames, such as matches or lighters. ▪ Do not smoke. ▪ Turn off the main gas supply. ▪ Open windows and doors. ▪ Warn other people in the building. ▪ Get out of the building. ▪ Inform your gas supplier, service agent or other competent
person.

2.3 Modifications on the unit

OPASNOST
Malfunctions can lead to poisoning and explosions. Never put the safety devices out of operation, nor tamper with them so as to impair their function.
OPREZ
Do NOT rinse the unit. This may cause electrical shock or fire.
OBAVEŠTENJE
▪ Do not place any objects or equipment on top of the
unit.
▪ Do not sit, climb or stand on the unit.
UPOZORENJE
Ako je napojni kabl oštećen, on MORA da bude zamenjen od strane proizvođača, njegovog zastupnika ili slično kvalifikovane osobe, da bi se izbegla opasnost.
3 Operacije

3.1 User interface

OPREZ
An inappropriate modification may cause damage. Never tamper with the boiler or other parts of the system. Never attempt to perform maintenance or repair yourself. Call a qualified service agent.
OPREZ
Do not use sprays, solvents, chlorinated cleaning agents, paint, and adhesives in the vicinity of the unit. These substances can cause corrosion, even in the flue system.
OPASNOST
Do not damage or remove any seals on components. Only qualified persons are allowed to alter sealed components.
Do not make any modifications on: ▪ Boiler ▪ Gas, water or power supply ▪ Flue system

2.4 For the user

OPREZ
Any misuse is forbidden. The manufacturer is not responsible for any malfunctions and/or damage that may occur due to misuse.
▪ Your unit is intended as a heater for central heating systems and
for domestic hot water generation. Any other use is considered as "misuse".
▪ If you are not sure how to operate the unit, contact your service
agent.
▪ Ovaj uređaj mogu koristiti deca starosti 8 godina i više, osobe sa
smanjenim fizičkim, čulnim ili mentalnim sposobnostima, ili sa nedostatkom iskustva i znanja, ako su pod nadzorom ili su dobili uputstva za upotrebu uređaja na bezbedan način, i razumeju opasnosti koje postoje. Deca NE SMEJU da se igraju uređajem. Čišćenje i korisničko održavanje NE SMEJU obavljati deca bez nadzora.
D2CNL024A1AA Wall-mounted condensing boiler 3P469438-12N – 2020.07

3.1.1 Buttons

The 6 buttons on the user interface have various functions according to different situations, which are stated in the table below:
Button/Dial Function Description
Mode / Enter / Reset
Menu / Back Menu Enter the menu function.
a CH+ b CH- c Mode / Enter / Reset d Menu / Back e DHW-
f DHW+
g LCD Screen
Mode Change mode between summer,
winter, central heating only and
standby. Reset Reset the lockout error. Enter Passing on to the next level in the
menu structure. Confirm Confirmation of changes.
Back Go back to the parent menu. Cancel Cancel changes.
Operation manual
3 Operacije
a
c
b
d
Button/Dial Function Description
CH+ / CH- User
interaction level
Menu level Selection of info, user, service menu.
DHW+ / DHW-
User interaction level
Menu level ▪ Selection parameter index.
Central heating temperature setpoint. This is either the central heating flow
temperature, the room temperature, or the virtual room temperature, depending on the system configuration.
Domestic hot water temperature setpoint.
▪ Change parameter values.

3.1.2 LCD screen

LCD screen is the monitor of the user interface. You can see the boiler operation mode, setpoints, information about actuators and menu parameters on this screen.
The LCD screen has a sleeping function. After one minute of non­interaction with the user interface, the screen darkens. Pressing any button or rotating any dial awakens the display.
When you interact with the user interface, the LCD screen will show the home screen of the active operation mode and the related setpoint, depending on the system configuration (see "Possible
operation modes"[44]).
Status icons
Meaning of icons that appear on the LCD screen:
Icon Description
Operation mode: Standby mode
Domestic hot water operation enabled Domestic hot water comfort mode is enabled
Central heating operation enabled
Room temperature
Outdoor sensor connection
Central heating ECO mode enabled
Flame Info menu
User settings menu
Service settings menu
INFORMACIJA
Low water temperature function is a safety function and it cannot be disabled.

3.3 Osnovna upotreba

3.3.1 About the home screen

It is the screen that is displayed after activating the LCD screen with one of the buttons. You can use the home screen to read out settings that are meant for daily use. What you can see on the home screen depends on your system configuration.
The following home screens may be possible: ▪ Central heating set temperature ▪ Virtual room temperature (with outdoor sensor) ▪ Domestic hot water set temperature ▪ System pressure (at standby mode)

3.3.2 To select the operation mode

The operation mode can be changed by pressing the "Mode" button.
a Standby mode b Summer mode c Winter mode d Central heating only mode

3.3.3 Possible operation modes

3.2 Operating the unit

3.2.1 To switch the unit ON

1 Connect the unit to the main power supply. 2 Select an operation mode by pressing the "Mode" button
shortly.
Usage of the unit is explained in following parts of this manual.

3.2.2 About the low water temperature function

The low water temperature function is a safety function that takes place at first central heating operation after each power supply interruption and at first central heating operation after each 90 days. When this function is active, boiler operates according to a defined set value for around 15 minutes and the icon blinks. After this function is ended, normal operation goes on.
Operation manual
Operation mode Description
Central heating only mode ▪ Only central heating operation mode
is enabled.
▪ The central heating temperature
setpoint (which setpoint is shown depends on the system configuration; see "Possible central
heating operation modes" [4 6]
and the icon is shown on the home screen.
▪ The icon is shown if central
heating operation is active.
D2CNL024A1AA
Wall-mounted condensing boiler
3P469438-12N – 2020.07
Operation mode Description
Standby mode ▪ Both central heating and domestic
hot water operation modes are disabled.
▪ The protection functions such as
frost protection are still active at standby mode.
▪ The home screen shows the system
pressure, as well as the icon.
Summer mode ▪ Only domestic hot water operation
mode is enabled. Central heating operation mode is disabled. The boiler will only produce heat for domestic hot water.
▪ The domestic hot water setpoint,
and the icon is shown on the home screen.
▪ The is shown if domestic hot
water operation is active.
Winter mode ▪ Both domestic hot water operation
mode and central heating operation mode are enabled. The boiler can produce domestic hot water, as well as produce heat for central heating.
▪ The central heating temperature
setpoint (which setpoint is shown depends on the system configuration; see "Possible central
heating operation modes" [4 6],
and the icon, as well as the icon are shown on the home screen. When domestic hot water operation is active, domestic hot water setpoint is shown on the home screen.
▪ The is shown and icon is
shown if domestic hot water operation is active.
▪ The is shown and icon is
shown if central heating operation is active.
3 Operacije
2 To apply changes done, wait for 3seconds or press the "Enter"
button. Pressing the "Cancel" button cancels the changes done.
To change the domestic hot water setpoint
1 Push DHW+ or DHW- buttons while you are at the home
screen. The setpoint screen will appear as shown below and the setpoint can be adjusted by pushing DHW+ or DHW­buttons. Napomena: The icon means you are at the setpoint screen.

3.3.4 Changing temperature setpoints

Temperature setpoints can be changed with the CH+, CH-, DHW+ and DHW- buttons.
To change the central heating temperature setpoint
1 Push CH+ or CH- buttons while you are at the home screen.
The setpoint screen will appear as shown below and the setpoint can be adjusted by pushing CH+ or CH- buttons. Napomena: The icon means you are at the setpoint screen.
D2CNL024A1AA Wall-mounted condensing boiler 3P469438-12N – 2020.07
2 To apply changes done, wait for 3seconds or press the "Enter"
button. Pressing the "Cancel" button cancels the changes done.
OBAVEŠTENJE
To be able to change the setpoint of central heating or domestic hot water, the corresponding operation mode must be enabled. If it is not, the related dial has no function.
Operation manual
3 Operacije

3.3.5 Possible central heating operation modes

Mode Description
Boiler only The case that the system only
contains the boiler. No outdoor sensor is connected. The central heating water temperature setpoint is displayed. The setpoint can be adjusted with CH+ or CH- buttons.
The icon is shown on the screen when the central heating operation mode is enabled.
Boiler + outdoor sensor (Weather compensation)
OBAVEŠTENJE
To enable weather compensation, the heating slope value must be higher than "0" (see "User settings menu:
Parameters (short)"[47]).
The case that outdoor sensor is connected to the boiler. In this case, the central heating water temperature is regulated according to the outdoor temperature. The virtual room temperature setpoint is diplayed. The virtual room temperature setpoint can be adjusted with CH+ or CH- buttons. Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature, respectively.
The and icons are shown on the screen when central heating operation mode is enabled.

3.3.6 About the central heating ECO mode

The central heating ECO mode provides more economic central heating. Main purpose of the ECO mode is to operate the boiler at the condensing temperature range so to increase the efficiency. ECO mode can be activated at any central heating operation mode explained above.
ECO mode can be enabled from the user settings menu (see "User
settings menu: Parameters (short)"[47]).
INFORMACIJA
ECO mode is only for central heating, it has no effect to domestic water heating.
When central heating ECO mode is enabled, icon is shown on the screen while the central heating operation mode is enabled.
OBAVEŠTENJE
In case of bad or inappropriate central heating circuit design, which causes inadequate heat emission to the living space, activating the ECO mode may cause capacity shortage.
INFORMACIJA
Domestic hot water operation mode must be enabled for the boiler to be able to produce domestic hot water. (i.e. summer mode or winter mode).

3.3.8 About the domestic hot water comfort mode

In this mode, water in the primary circuit is kept warm to be able to provide domestic hot water faster when there is demand.
Comfort mode can be enabled from the user settings menu (see
"User settings menu: Parameters (short)"[47]).
When the domestic hot water comfort mode is enabled, the icon is shown on the screen.

3.3.9 About the boiler frost protection

Frost protection safety system: This function protects the unit and
heating installation from frost damages. This protection activates the boiler pump when the water temperature drops below 15°C and it activates the burner when the water temperature drops below 5°C (factory setting). The unit keeps running until the temperature reaches 15°C. To enable this function, the unit must be connected to the power supply and its main gas valve must be open. Any damage caused by frost is not covered by the warranty. Frost Protection is enabled in all modes, including standby mode and full-off mode.
While frost protection is active, actual flow temperature is displayed.
UPOZORENJE
If the boiler is not connected to the power supply, frost protection is not active. Consequently, the water may freeze and cause cracks. The manufacturer is not responsible for any damage that may occur this way.
OBAVEŠTENJE
When not using the boiler, we strongly recommend not to cut off the electric supply to the boiler.

3.4 Error handling

When an error occurs, the normal behaviour of the user interface is interrupted. However, be aware that not all errors have the same effect on the user interface and the status indicator.
Error
type
Warning Continue The LCD screen stays active and
Blocking Blocked, turns back
Lockout Blocked and a
Boiler operation User interface and status
indicator
displays the error code.
The LCD screen stays active and to operation if cause disappears
reset is required
displays the error code.
The LCD screen stays active and
displays the error code. Also, the
icon starts blinking, indicating that a
reset is required.

3.3.7 About the domestic hot water operation

This unit supplies domestic hot water by way of a plate heat exchanger.
Domestic hot water operation is activated when water is being tapped. Water flow rate must be at least 2.6l/min.
The icon is shown when domestic hot water operation is active.
Operation manual
In case of a warning or a blocking error, the user interface will leave error mode and return to the home screen when the cause of the error disappears.
In case of a lockout error, the boiler needs to be reset. Press the "Reset" button to remove the error, if the cause of the error is gone. If the cause of the error is still there, the user interface will enter error mode again. When the error is solved, the user interface returns to the home screen.
If you or press any button (except the "Reset" button) during an error, the user interface will display the home screen. After the timeout without any interaction, instead of darkening, the user interface will enter error mode.
D2CNL024A1AA
Wall-mounted condensing boiler
3P469438-12N – 2020.07
3 Operacije
INFORMACIJA
“Reset” button must be pressed for 3 seconds to remove the error.
OBAVEŠTENJE
A table with all error codes, the reasons for their appearance, and possible solutions, is located at the very end of this manual.

3.5 Menu functions

3.5.1 To use menu level 1

1 Press the "Menu" button while you are at home screen to go the
Menu screen. This is menu level 1 screen.
2 To switch between info, user settings and service settings,
press CH+ and CH- buttons.
3 To leave the menu and return to the home screen, press "Back"
button.
When there is no user interaction for one minute, the user interface will leave the menu and switch to the blank screen.
To use the info menu
1 Press the "Enter" button when the icon is displayed on the
menu level 1 screen.
2 Select the index number with DHW+ and DHW- buttons. Press
the "Back" button to return to menu level 1 screen.

3.5.3 User settings menu

User settings menu: Parameters (short)
The user settings menu ( ) comprises parameters that can be changed and adjusted by users. You can read out and adjust the parameters according to your preferences.

3.5.2 Info menu

Info menu: Parameters
The info menu ( ) covers all possible information that is made available to the end user and to the installer. This parameters are read only and cannot be changed.
# Description (short) Unit A0 Actual flow temperature °C A1 Actual return temperature °C A2 Actual domestic hot water temperature °C A3 Actual flue temperature °C
(a)
A4 A5
A6 Actual water pressure bar A7 Actual domestic hot water flow rate l/min A8 Actual fan speed (rpm/100) rpm A9 Current setpoint of boiler pump % B0 Software version 0 B1 μ com ID low digit - B2 μ com ID high digit - B3 Ionisation current μA
Actual outdoor temperature °C
(a)
Actual solar temperature °C
(a) Not applicable if the sensor is not connected.
OBAVEŠTENJE
If you are not sure about the function of the parameter, do not change it. Contact your service agent.
# Description Unit Default Range
U0 Summer-winter switch over
temperature
U1 Heating slope 0 0~40 U2 Central heating ECO mode 0 0~1 U3 Domestic hot water comfort
mode
°C 20 10~30
0 0~1
User settings menu: Parameters (detailed)
# Description
U0 When using outdoor sensor, above this parameter
value of outside temperature, the boiler senses the season as summer and does not activate central heating although there is demand. Summer-winter switching has a hysteresis of ±1ºC.
i.e: When this parameter is adjusted to 20ºC, the boiler switches to summer mode at 21ºC and switches back to winter mode at 19ºC.
U1 This value is used when outside sensor is connected to
the boiler. The parameter heating slope is important to adapt the weather compensation to the individual heating system, the building and the thermal insulation.
The heating slope can be adjusted from 0 to 40. The heating slope needs to be increased to increase the boiler central heating set temperature. Colder regions require a higher heating slope value.
Napomena: To activate weather compensation, the
heating slope value must be higher than "0".
U2 Enabling / disabling central heating ECO mode.
1 = enabled, 0 = disabled
D2CNL024A1AA Wall-mounted condensing boiler 3P469438-12N – 2020.07
Operation manual

4 Maintenance and cleaning

# Description
U3 Enabling / disabling domestic hot water comfort mode.
1 = enabled, 0 = disabled
To use the user settings menu
1 Press the "Enter" button when the icon is displayed on the
menu level 1 screen.
Rezultat: You can see the parameter on menu level 2. 2 Select the index with DHW+ and DHW- buttons. 3 Press the "Enter" button when the parameter that you want to
change is displayed.
Rezultat: You can see the menu level 3 screen. Up and down
arrows will appear.
4 Change the parameter with DHW+ and DHW- buttons. 5 Press the "Enter" button to confirm or the "Cancel" button to
cancel. You will return to menu level 2 after pressing "Enter" or
"Back"

4.1 To clean the outer surface of the unit

Clean the outer surface of your boiler with a damp cloth and a little solvent-free soap.
OPREZ
Sprays, solvents or cleaning agents containing chlorine can damage the exterior, the fittings or the control unit. Do not use them for cleaning purposes.

5 Energy saving tips

▪ Operating the unit in central heating ECO mode provides the most
economical central heating operation conditions.
▪ Do not run the boiler in domestic hot water comfort mode.
Domestic hot water comfort mode involves pre- and post-heating,
which is luxury, not necessity. ▪ Close the thermostatic radiator valves when ventilating the rooms. ▪ The largest heat loss occurs through windows and outer doors.
Check windows and doors for air-tightness. Close any blinds at
night. ▪ Do not hide radiators behind large furniture (i.e. couch, desk, etc.).
Minimum 50cm of clearance must remain, otherwise the heated
air cannot be circulated and the room will not heat up efficiently. ▪ Do not let your room become too hot. Decreasing the room
temperature during the day saves energy. ▪ Have your combi boiler's maintenance performed at least
annually. ▪ Provide your building with sufficient heat insulation. ▪ Thermostatic valves should be used. Each room should be
adjusted according to comfort conditions. For reception rooms,
this is 20°C, living rooms 22°C, kitchens 18°C and bedrooms
18°C. ▪ Prevent radiators from getting covered by curtains.

3.5.4 Installer settings menu

Only qualified persons are allowed to enter the installer settings menu.
4 Maintenance and cleaning
UPOZORENJE
The boiler should be maintained by authorised persons every year.
Annual maintenance cycle is very important for safe operation of your boiler and to ensure reliable, efficient and long lasting operation of it.
Contact your service agent for details.
OPASNOST
Incorrect maintenance and repairs can lead to injury and material damage.
▪ Never attempt to perform maintenance work or repairs
on the unit yourself.
▪ Contact your service agent.

6 Contact

Contact a local competent service agent if you have any questions regarding the maintenance and repair of your system. You can find the contact information of our competent services at www.daikin.com

7 Error codes

# Problem Solution
10-64 Gas valve circuit error Perform reset. If problem repeats,
contact your service agent.
11-64 Ignition does not take
place
11-67 Flame loss during
operation
13-64 Fan speed error Perform reset if needed. If problem
13-65 Fan speed error Perform reset. If problem repeats,
16-64 Flue temperature
signalise overheating
Make sure valve on the gas line is opened. Perform reset after third unsuccessful ignition trial.
Temporary error. Wait for boiler to re-ignite.
repeats, contact your service agent.
contact your service agent. Check flue gas discharge path.
Perform reset if needed. If problem repeats, contact your service agent.
Operation manual
Wall-mounted condensing boiler
D2CNL024A1AA
3P469438-12N – 2020.07
7 Error codes
# Problem Solution
1J-64 High limit thermostat
signalise overheating
80-01 Return temperature
sensor fault
81-01 Flow temperature
sensor fault
81-65 Domestic hot water
solar temperature sensor fault
8A-46 Freeze protection Unit does not operate if flow
8H-64 Flow temperature
steep rise
8H-65 Flow-return
temperature difference too much
E1-64 Flame detection
before burner operation
E1-69 Parameter CRC error Perform reset. If problem repeats,
E1-71 EK lockout failure Permanent error. Contact your
E1-73 Internal PCB error Perform reset if needed. If problem
H9-01 Outside sensor fault Boiler continues operation but
HC-01 Domestic hot water
temperature sensor fault
HJ-08 High system pressure Discharge water down to 0.8bar.
HJ-09 Low system pressure Increase the system pressure to
HJ-10 Water pressure
sensor fault
J6-01 Flow temperature
sensor overheating (Can be a blocking
error or a lockout error)
J6-21 Return temperature is
higher than flow temperature
JJ-64 Flue temperature
sensor fault
▪ Check the valves of the radiators
in the heating circuit.
▪ Check the combi boiler water
pressure. If it is low, fill the heating circuit with water.
▪ Perform reset. If problem repeats,
contact your service agent.
Perform reset. If problem repeats, contact your service agent.
Perform reset. If problem repeats, contact your service agent.
Boiler continues operation but solar sensor is defective. Contact your service agent.
temperature sensor reads value less than 1°C. Wait until the error code is removed from the screen.
Make sure radiator valves are open enough to circulate water. Your boiler will operate again after a while. If problem repeats, contact your service agent.
Make sure radiator valves are open enough to circulate water. If problem repeats, contact your service agent.
Perform reset. If problem repeats, contact your service agent.
contact your service agent.
service agent.
repeats, contact your service agent.
outside sensor is defective. Contact your service agent.
Boiler continues operation but you must contact your service agent.
(You can bleed the radiators.)
0.8bar Contact your service agent.
▪ Check the valves of the radiators
in the heating circuit.
▪ Check the combi boiler water
pressure. If it is low, fill the heating circuit with water.
▪ Perform reset if needed. If problem
repeats, contact your service agent.
No reset needed, burner operates itself after a small amount of time. If problem repeats, contact your service agent.
Perform reset. If problem repeats, contact your service agent.
# Problem Solution
U4-67 Remote reset
supervision
Switch off - switch on power mains. If problem repeats, contact your service agent.
D2CNL024A1AA Wall-mounted condensing boiler 3P469438-12N – 2020.07
Operation manual
DAIKIN ISITMA VE SOĞUTMA SİSTEMLERİ SAN.TİC. A.Ş.
İSTANBUL / TÜRKİYE Tel: 0216 453 27 00 Faks: 0216 671 06 00 Çağrı Merkezi: 444 999 0 Web: www.daikin.com.tr
Gülsuyu Mahallesi, Fevzi Çakmak Caddesi, Burçak Sokak, No:20, 34848 Maltepe
Verantwortung für Energie und Umwelt
Copyright 2020 Daikin
3P469438-12N 2020.07