1General safety precautions
Please read these general safety precautions carefully before
installing air conditioning equipment, and be sure to install the
equipment correctly.
Failure to follow these instructions properly may result in property
damage or personal injury, which may be serious depending on the
circumstances.
WARNING
To prevent electric shocks or fire:
▪ Do NOT operate the user interface with wet hands.
▪ Do NOT disassemble the user interface and touch
interior parts. Contact your dealer.
▪ Do NOT modify or repair the user interface. Contact
your dealer.
▪ Do NOT relocate or reinstall the user interface by
yourself. Contact your dealer.
WARNING
Do NOT use flammable materials (e.g. hairspray or
insecticide) near the user interface.
NOTICE
To clean the user interface, do NOT use organic solvents,
such as paint thinner. Possible consequence: damage,
electric shock, or fire.
1.2For the installer
The precautions described in this document cover very important
topics, follow them carefully.
INFORMATION
This user interface is an option and cannot be used
standalone. It can ONLY be used in combination with a
main user interface. Also see the installation and operation
manual of the indoor and outdoor units.
Installation and operation manual
2
BRC1HHDAW + BRC1HHDAS + BRC1HHDAK
Human Comfort Interface
4P534400-1 – 2018.06
2 About this document
NOTICE
Improper installation or attachment of equipment or
accessories could result in electric shock, short-circuit,
leaks, fire or other damage to the equipment. Only use
accessories, optional equipment and spare parts made or
approved by Daikin.
WARNING
All field wiring and components MUST be installed by a
licensed electrician and MUST comply with the applicable
legislation.
NOTICE
The user interface MUST be mounted indoors.
NOTICE
When the user interface is used as room thermostat, select
an installation location where the average temperature in
the room can be detected.
Do NOT install the user interface in the following places:
▪ In places that are exposed to direct sunlight.
▪ In places that are near a heat source.
▪ In places that are affected by outside air or air draught due to e.g.
door opening/closing.
▪ In places where the display can easily get dirty.
▪ In places where there is NO easy access to the controls.
▪ In places with temperatures <–10°C and >50°C.
▪ In places where the relative humidity is >95%.
▪ In places where there is machinery that emits electromagnetic
waves. Electromagnetic waves may disturb the control system,
and cause malfunction of the equipment.
▪ In places where it may be exposed to water, or in generally moist
areas.
If you are NOT sure how to install or operate the unit, contact your
dealer.
After finishing installation:
▪ Conduct a trial operation to check for faults.
▪ Explain the user how to operate the user interface.
▪ Ask the user to store the manual for future reference.
INFORMATION
Consult your dealer regarding the relocation and
reinstallation of the user interface.
2About this document
Target audience
Authorised installers + end users
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ Installation and operation manual:
▪ Installation instructions
▪ Basic operation instructions
▪ Format: Paper (in the box of the user interface)
▪ Installer and user reference guide:
▪ Extended installation and operation information
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
▪ Declaration of conformity:
▪ Hereby, Daikin Europe N.V. declares that the radio equipment
type BRC1HHDA is in compliance with the Directive 2014/53/
EU. The original declaration of conformity is available from the
BRC1HHDA product pages https://qr.daikin.eu/?
N=BRC1HHDW, https://qr.daikin.eu/?N=BRC1HHDS, and
https://qr.daikin.eu/?N=BRC1HHDK.
▪ Format: Digital file from the product pages
(BRC1HHDAW)
(BRC1HHDAS)
(BRC1HHDAK)
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
▪ When space heating/cooling and/or domestic hot water
operation is OFF, press to turn it ON.
▪ When space heating/cooling and/or domestic hot water
operation is ON, press to turn it OFF.
b
CYCLE/ENTER/ACTIVATE /CONFIRM
▪ From the home screen, short press to cycle through the
operation screens.
▪ From the home screen, long press to go to the main menu.
▪ In the main menu, short press to enter one of the menus.
▪ In any of the menus, activate/confirm a function, value, or
setting.
c
ACTIVATE/CYCLE/ADJUST
▪ On the room temperature/domestic hot water operation
screen, activate the setpoint screen.
▪ In the main menu, cycle left.
▪ In any of the menus/operation screens, adjust a function,
value, or setting (default: decrease).
d
ACTIVATE/CYCLE/ADJUST
▪ On the room temperature/domestic hot water operation
screen, activate the setpoint screen.
▪ In the main menu, cycle right.
▪ In any of the menus/operation screens, adjust a function,
value, or setting (default: increase).
INFORMATION
The user interface is equipped with a power saving
function that causes the screen to darken after a period of
inactivity. To make the screen light up again, press one of
the buttons.
3.3Status icons
IconDescription
System operation OFF. Indicates that space heating/
cooling operation and/or domestic hot water operation
are turned OFF.
Bluetooth.1 Indicates that the user interface is
sending out a Bluetooth signal and is ready to perform
a software update.
Heating operation. Indicates that the system is
operating in Heating operation mode.
Cooling operation. Indicates that the system is
operating in Cooling operation mode.
Powerful operation. Indicates that Powerful
operation is active.
Emergency. Indicates that Emergency operation is
active.
Warning. Indicates that an error occurred.
INFORMATION
When the user interface signals Emergency or Warning,
see the main user interface to see what is wrong.
INFORMATION
For more information on the Bluetooth signal and the
software update, see the installer and user reference
guide.
4Operation
4.1Basic usage
3.2Home screen
The home screen displays the actual room temperature, and all
kinds of information through status icons. After a period of operation
inactivity the user interface will always revert to the home screen.
(1)
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and use of such marks by
Daikin Europe N.V. is under license. Other trademarks and trade names are those of their respective owners.
Installation and operation manual
4
4.1.1Operation screens
From the home screen, press (shortly) to cycle through the
operation screens.
BRC1HHDAW + BRC1HHDAS + BRC1HHDAK
Human Comfort Interface
4P534400-1 – 2018.06
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.