Warning
Intended use
This Comelit product was designed for use in the creation of audio and video communication systems in residential,
commercial or industrial settings and in public buildings or buildings used by the public.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with
careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Cut o the power supply before carrying out any maintenance procedures.
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system
manual.
We advise against running the system wires through the same duct as the power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction sheets
• make sure the system created using Comelit products has not been tampered with / damaged.
Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance
with the indications provided in the Manuals / Instruction sheets.
Any repair work must be carried out
• for the products themselves, exclusively by Comelit Group S.p.A.,
• for systems, by qualified technical personnel.
Disclaimer
Comelit Group S.p.A. does not assume any responsibility for
• any usage other than the intended use
• non-observance of the indications and warnings contained in this Manual / Instruction sheet.
Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this Manual / Instruction
sheet at any time and without prior notice.
Table of contents
Warning ............................................................................................ 2
Description of the monitor .............................................................. 3
Key functions ............................................................................................3
Activating function keys: .........................................................................3
LED signals ...............................................................................................3
ViP Maxi Monitor Menu ................................................................... 4
Date and time settings .............................................................................4
Functions available .......................................................................... 4
Intercoms ..................................................................................................4
Cameras ....................................................................................................4
Actuators ..................................................................................................5
Doors open ...............................................................................................5
Memory setup ...........................................................................................5
Video memory .............................................................................5
Record always .............................................................................5
Message ....................................................................................................5
Video memory ..........................................................................................6
Call divert ..................................................................................................6
2
Wi-Fi connection (applies to art. 6842W) ...............................................6
“Wi-Fi connection status” icon ...........................................................6
Wi-Fi setup ..........................................................................................6
Wi-Fi reporting unconnected ..............................................................7
App registration enable .......................................................................7
User Setup menu ............................................................................. 8
Language ..................................................................................................8
Lock keypad and touch screen ...............................................................8
Information ...............................................................................................8
Volume adjustment ..................................................................................8
Backlight adjustment ...............................................................................9
Melody settings ........................................................................................9
Activating direct keys ..............................................................................9
User administration (applies to art. 6842W) ..........................................9
Screen saver .................................................................................. 10
Installer setup menu ...................................................................... 10
NAVIGATION TREE ................................................................................. 10
Description of the monitor
1. Microphone
2. Built-in Wi-Fi (Art. 6842W only)
3. Built-in magnetic induction loop (Art. 6842W,
6802B, 6802W/BM only)
4. 7" touch screen
5. Soft-touch keys / Indicator LEDs
6. Soft-touch keys / Indicator LEDs
7. Micro SD card port
Key functions
AUDIO: allows you answer incoming calls
√ Incoming call:
f Press to start the conversation
f Press again to interrupt the conversation
» It is possible to resume the conversation
with the external unit for as long as the
LED continues to flash
[programmable]
LOCK-RELEASE: opens the corresponding door
lock
ACTUATOR: allows activation of the associated
relay
[programmable]
PRIVACY: the ringtone will be silenced on receipt
of a call from the external unit and from the
switchboard
DOCTOR: allows automatic operation of the lock-
release on receipt of a call from an external unit
PRIVACY + DOCTOR: activates both functions
[programmable] [Default: deactivated]
INTERCOM / SELF-IGNITION / CALL PRIORITY
1-4 / LOCK-RELEASE / ACTUATOR / ACTIVATE
OUTPUT / FUNCTION DISABLED
MESSAGE MENU: allows access to the Message
section
DOORS OPEN: allows access to the Doors open
section
[programmable]
SELF-IGNITION: allows ignition of the external
video unit, and therefore viewing of the external
image
INTERCOM / SELF-IGNITION / CALL PRIORITY
1-4 / LOCK-RELEASE / ACTUATOR / ACTIVATE
OUTPUT / FUNCTION DISABLED
Activating function keys:
f Touch to activate the function keys.
LED signals
STEADY LED: audio active
FLASHING LED: call in progress
1 FLASH: door opening confirmation
FLASHING LED: call in progress
3 FLASHES EVERY 5 SEC.: Doctor mode
activated
STEADY LED: Privacy mode activated
Alternate STEADY AND FLASHING LED: Doctor
and Privacy active
STEADY LED: video memory activated / call
divert activated
FLASHING LED: indicates new message received
STEADY LED: signals the opening of one or more
doors
3
ViP Maxi Monitor Menu
Language
SETUP
Lock keypad and touch screen
Information
Volume adjustment
or you can set the date and time manually:
f Select “Set date and time”
The menu icons vary depending on the type of system
installed and the functions available. To navigate the menu,
simply use your finger to touch the icon corresponding to the
desired function.
f Touch the display to access the main menu
07:15
10/01/2017
f Press the desired menu option to select it
07:15
01/01/2018
With Art. 6842W only
f Navigate the menus by scrolling up/down through the
page
Set the desired values for day / month / year /
hours / minutes
Save the configuration
Functions available
07:15
01/01/2018
Function can be enabled via ViP Manager software
Only available if the corresponding Directory has been
configured
Only available if the “call divert” function has been
configured
f Short press the icon to return to the previous screen
Date and time settings
This function allows you to set the time and date of the
device.
07:15
01/01/2018
f To automatically update the date and time via internet,
select “Automatically set the Date & Time”
Automatically set the Date & Time
Set date and time
f Press the date and time
Date and time settings
Intercoms
This function allows you to call addresses saved in the
directory.
f Press the icon to access the
function, then select from the
directory the device which you
wish to call
Or make a “direct call”
[Function can be disabled using ViP Manager software]
1. Press the icon 123 to call a specific ViP address
Intercoms 123
2. Enter the address in the field to start the
communication
Cameras
This function allows you to view a directory of cameras and to
start live streaming.
f Press the icon to access the
function, then select from the
directory the camera to be
interrogated
4