This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and
in public buildings or buildings used by the public.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Cut o the power supply before carrying out any maintenance procedures.
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
We advise against running the system wires through the same duct as the power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction sheets
• make sure the system created using Comelit products has not been tampered with / damaged.
Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the
Manuals / Instruction sheets.
Any repair work must be carried out
• for the products themselves, exclusively by Comelit Group S.p.A.,
• for systems, by qualified technical personnel.
Disclaimer
Comelit Group S.p.A. does not assume any responsibility for
• any usage other than the intended use
• non-observance of the indications and warnings contained in this Manual / Instruction sheet.
Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this Manual / Instruction sheet at any time and without prior
notice.
Table of contents
Description of the monitor .............................................................. 3
Description of buttons .............................................................................4
Indicator LED description........................................................................4
In systems with more than one monitor connected in cascade, only the monitor furthest away must have CV5 closed.
11. Pin for securing terminal block
Terminal block for system connection:
LL Bus line connection terminals
CFP1 CFP2 Floor door call input
3
Description of buttons
f Press the desired button once to activate the associated function.
Wait for approximately 1 sec. before pressing the same button again. Pressing the same button several times in
quick succession will cancel the command.
LOCK-RELEASE
Use this key to open the corresponding door lock.
ACTUATOR default (programmable*)
Allows activation of the associated relay.
SELF ACTIVATION default (programmable*)
Allows activation of the external video unit, and therefore viewing of the external image.
SILENT MODE (Privacy)
The ringtone will be silenced on receipt of a call from the external unit and from the switchboard.
PROGRAMMABLE BUTTONS
Applies to monitor 6701W/8
(*) Buttons may be programmed as:
• DOOR OPENING UPON CALL (Doctor)
Allows automatic operation of the associated lock-release on receipt of a call from an external unit.
f To activate/deactivate Door opening upon call, press and hold the button programmed for this function.
• INTERCOM
Allows a call from one internal unit to one or more internal units.
• CALL TO A MAIN OR SECONDARY SWITCHBOARD
• PRIORITY CALL TO SWITCHBOARD (“PAN”)
• CALL TO CARETAKER DOOR-ENTRY PHONE
Indicator LED description
Flashing LED: incoming call
1 flash after pressing button: confirms door opening
slow flashing: door open
FLASHING LED: device in programming mode
4 flashes: system engaged
Steady LED: Silent mode (Privacy) activated
3 flashes every 5 sec.: Door opening upon call function (Doctor) active