Citizen Eco Drive B740, Eco Drive B741 Settings Manual

Setting Guide for Eco Drive
Movement Caliber B740 / B741
Contents
(click on a topic)
1. Outline
2. Specifications
3. About Solar Powered Watches
4. Handling the Watch
a) Name of Parts
c) Time Required for Charging
d) Special Care for This Solar Powered Watch
e) Switching Between Modes
f) Adjusting the Time and Date (Time Mode)
g) Diving Mode
h) Chronograph Mode
i) Measure Against Possible Problems
j) Setting Function Hand at ‘0’ Position
k) All Reset / Adjusting Hand Position
5. Relationship Between Charge Level Indication and Running Period of Watch
6. Note on the Eco Drive Manganese Titanium Rechargeable Battery
7. Precautions for Diving
8. Care of your Watch
i
Return to Table of Contents
1. OUTLINE
This watch is an analog solar powered diver's watch into which an electronic depth meter and chronograph function and chronograph function are built. The solar power generation function transforms solar energy into electrical energy to run the watch.
• Since solar energy is used as the power source of this watch, it has no need
of regular replacement of the battery unlike the general diver's watches using the mercury cell, etc. (Solar power function)
• The built-in depth meter function automatically measures the depth in diving
with the watch worn on the wrist. (Depth meter function)
• The maximum depth in diving is automatically memorized. (Maximum depth
memorizing function)
• The chronograph function measures the time in units of one second for
50
minutes at maximum.
2. SPECIFICATIONS
Movement Caliber NO.
Type
B740M / B741 M
Analog solar power watch
Watch Accuracy (At normal temperature)
Depth gauge accuracy
Operating temperature
Display functions
Time
Calendar
Chronograph
Depth gauge
±15 sec/month (5'C-35OC/41"F-95"F)
At depth of 1 to 1 Om/5.0 to 25.Oft: within ± 1 m/±5.Oft At depth of 1 to 1 to 50m/27.5 to 125.Oft: within ±2m/±7.5ft On the condition that the water temperature is constant and error in reading is excluded. Temperature range for guaranteed accuracy: +10'C to
40'C/50'F to 104OF Depth gauge accuracy is influenced by changes in surrounding temperature.
-1OC to +60OC/14F to 40F
Hour, Minute, Second, 24-hour, Charge level
Date
Minute, Second (50-minute system)
1 m to 50m/5ft to 1 25ft Reading in units of lm/5ft Depth less than 1 m/5ft is indicated as 0m/Oft. Depth more than 50m/1 25ft is indicated as over-zone
Maximum depth to be memorized
Additional functions
Continuous operating time
Additional Comments
1 m to 50m/5ft to 1 25ft
*
Charge level indication function
*
Insufficient charge warning indication a Stop
warning function
*
Time reset warning function
*
From full charge to stopping: Approx. 2 months
*
From full charge to NGindication: Approx. 1 month
*
Form insufficient charge warning to stopping: Approx.
2 days
Movement Cal
ber B740: Depth indicationin meters
Movement Caliber B741: Depth indication in feet
Return to Table of Contents
Return to Table of Contents
3. SOLAR-POWERED WATCH
When the watch is used for diving (about two hours a week), it will run for about one month (until NG is indicated).
An Eco Drive Rechargeable battery is used in this watch to store electrical energy. If the rechargeable battery is fully charged once, the watch will continue running for about two months.
<How to use this watch properly>
It is recommended that you recharge the battery everyday. To insure that this watch demonstrates its depth meter function and chronograph
function besides the timekeeping function, always keep it sufficiently charged. If the battery is not sufficiently charged or the battery power is very low, the depth meter function and chronograph function cannot be activated. The battery of this watch is protected from overcharge. * For recharging the battery, expose the solar cell (the face of the watch) to light.
4. USING THIS WATCH
A. Name of Parts
Charge levels
Over-zone
mark
Depth meter
scale
Pressure
sensor
Water sensor
Rotating bezel
Solar cell
Charge level of the battery (battery power) is indicated as follows (LV.1, LV.2, NG) by the function hand. These guidelines indicate whether the depth meter function is usable or not.
When the diving depth exceeds 50 meters (125 feet) or there is something abnormal in the depth meter function, the function hand points to the over- zone mark.
The diving depth is indicated by the function hand on this depth meter scale.
Measures the depth by sensing the water pressure.
When the water sensor gets wet, the watch is automatically shifted to the diving mode.
The diver can know the elapsed time of diving by using this rotating bezel.
Electric energy necessary for running the watch is generated by this solar cell when it is exposed to enough light for charging the battery.
Return to Table of Contents
[
Return to Table of Contents
B. Warning Function of this Solar Powered Watch
With decline of the battery power of this watch, its warning function is activated to change the indication.
[Normal indication (Time mode)]
Function hand: Points
LV.2, LV.1
at
NG.
or
Insufficient charge warning indication]
Function hand: Points at
NG
[Stop
warning
indication]
Function hand: Points at "O" Mode hand: Points at "O".
[Time reset warning indication]
Function hand: Points at
NG,
Charge Level Indication
The function hand indicates the charge level as follows (LV.1, LV.2 and NG) to let the user know whether the watch can be used for diving or not. In the diving mode, consumption of battery power is considerably increased because the pressure and water sensors are actuated. Before using this watch for diving, charge the battery sufficiently and confirm the charging level which is indicated by the function hand.
<When the function hand points at LV.1 (at 56- seconds’ position)>
The watch is securing battery power enough for sports diving at the depth of 20m (66ft) or so for about an hour.
• However, when the function hand points at LV.1 as a result of charging the battery after it was once depleted (after the status that the function hand indicated NG), be sure to charge the battery with a lighting of 3000 lux (20 cm under a fluorescent lamp) for at least 10 minutes before diving.
• If diving continues for more than one hour, pay careful attention to the indication of the function hand, because the indication may change to NG from LV.1 during the diving and the watch may discontinue measuring the depth.
<When the function hand points at "LV.2" (54 seconds)>
The battery is almost fully charged. Accordingly, the watch can be used reliably for diving.
Return to Table of Contents
Return to Table of Contents
<When the function hand points at "NG" (58 seconds)>
The watch will not shift to the diving mode because of insufficient charging. When the watch is in this status, it cannot be used for diving because its depth meter function won't be activated. If the function hand points to "NG" during a dive, immediately stop using relying on the watch for depth measurement.
x Use the indication of the charge level as a reference only. x If the watch is exposed to strong light for charging the battery,
the function hand may temporarily indicate "LV.I" or "LV.2" despite insufficient charging. If the function hand goes to "LV.1" or "LV.2" from "NG" position in a short time, you need to pay careful attention to charging conditions. It is recommended that you keep the battery sufficiently charged all the time but especially before using the watch for diving. Always check the indication of charge level carefully just before diving. (For details of charging time, refer to "C. Time Required for Charging".)
Insufficient charge warning function
Insufficient charge warning indication ­Made hand: DV position, Function hand: NG position-
Whenever the battery power becomes insufficient for operation, the watch is automatically shifted to the Time mode regardless of the currently set mode and the second hand goes for 2-second interval movement. (insufficient charge warning indication) If the watch is left in this condition without recharging for another two days, the watch will stop.
• If the watch falls into such condition, the
time measurement will be discontinued in the chronograph mode.
• While the watch is falling into the
insufficient charge warning indication, all button operations are ineffective except the maximum depth operation.
Since the watch continues accurate indication of the date and time even in the insufficient charge warning indication, the watch will recover normal operation if it is exposed to light sufficient for charging the battery. For using the watch the watch for diving, sufficiently charge the battery until the function hand indicates “LV.1” or “LV.2” on the charge level.
Return to Table of Contents
Return to Table of Contents
Stop warning function
Stop warning indication
- Mode hand: "O" position, Function hand: "O" position -
If the watch is left in the insufficient charge warning indication for two days, both the mode hand and function hand will move to "O" position respectively, If the watch falls into this condition, it indicates that the watch has stopped operation completely. (Stop warning indication)
* All functions of the watch are inactivated in this indication.
When the rechargeable battery is charges in this condition, the watch restarts operation as it is switched to the time reset warning indication
Time reset warning function
Time reset warning Indication - Mode hand: DV position, Function hand: NG position -
With progress in charging the battery as the watch is exposed to light, the watch starts running but shows incorrect time. In this condition the second hand moves irregularly every two seconds to show that the time is incorrect. (Time reset warning indication)
To change the watch to time mode, reset the watch correctly after fully charging the rechargeable battery.
If the rechargeable battery is sufficiently charged but the watch has not been reset to the correct time, the second hand continues to go irregularly every two seconds
Overcharge prevention function
This watch has an overcharge prevention function. When the secondary battery is fully charged, this function is activated to protect the battery from overcharge by cutting of power supply. This function relieves you from worry about overcharge.