Cisco PWR-C2-1025WAC Installation Manual

Page 1
Power Supply Installation
This chapter applies only to the Catalyst 6800IA-48FPDR switch. It contains these topics:
Power Supply Module Overview, page 1
Installation Guidelines, page 3
Installing or Replacing an AC Power Supply, page 4
Finding the Serial Number, page 5
Power Supply Module Overview
Table 1: Power Supply Model Numbers and Description
DescriptionPart Number
1025-W AC power supply modulePWR-C2-1025WAC=
The 1025-W power supply module is an autoranging unit that supports input voltages between 115 and 240 VAC. All power supply modules have internal fans. All switches ship with a blank cover in the second power supply slot.
OL-30278-02 1
Catalyst 6800IA Switch Hardware Installation Guide
Page 2
Power Supply Module Overview
Each AC power supply module has a power cord for connection to an AC power outlet.
Figure 1: PWR-C2-1025WAC Power Supply
Power Supply Installation
AC power cord connector4AC OK LED1
Release latch5PS OK LED2
Power supply6AC power cord retainer3
If no power supply is installed in a power supply slot, install a power supply slot cover.
Figure 2: Power Supply Slot Cover
Catalyst 6800IA Switch Hardware Installation Guide
2 OL-30278-02
Page 3
Power Supply Installation
Installation Guidelines
Retainer clips2Release handles1
The power supply modules have two status LEDs.
DescriptionPS OKDescriptionAC OK
Green
Installation Guidelines
Observe these guidelines when removing or installing a power supply module:
Do not force the power supply module into the slot. This can damage the pins on the switch if they are
not aligned with the module.
A power supply that is only partially connected to the switch can disrupt the system operation.
Remove power from the power-supply module before removing or installing the module.
The power supply is hot-swappable.
present.
OffNo AC input power.Off (AC LED is off)
Output is disabled, or input is outside operating range.
Power output to switch.GreenAC input power is
Output has failed.Red
Caution
Do not operate the switch with one power-supply module slot empty. For proper chassis cooling, both module slots must be populated, with either a power supply or a blank module.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1024
Warning
Do not reach into a vacant slot or chassis while you install or remove a module. Exposed circuitry could constitute an energy hazard. Statement 206
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
OL-30278-02 3
Catalyst 6800IA Switch Hardware Installation Guide
Page 4
Installing or Replacing an AC Power Supply
Power Supply Installation
Warning
If a Cisco external power system is not connected to the switch, install the provided connector cover on the back of the switch. Statement 386
Installing or Replacing an AC Power Supply
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Turn off the power at its source.
Remove the power cord from the power cord retainer.
Remove the power cord from the power connector.
Press the release latch at the right side of the power supply module inward and slide the power supply out.
Do not leave the power-supply slot open for more than 90 seconds while the switch is operating.Note
Warning
This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028
Insert the new power supply into the power-supply slot, and gently push it into the slot. The 1025-W power-supply module extends inches from the switch rear panel.
Figure 3: Inserting the AC-Power Supply in the Switch
Catalyst 6800IA Switch Hardware Installation Guide
4 OL-30278-02
Page 5
Power Supply Installation
Finding the Serial Number
Step 6
Step 7
Step 8
Step 9
(Optional) Make a loop in the power cord and thread it through the power cord retainer.
Figure 4: AC-Power Supply with Power Cord Retainer
Connect the power cord to the power supply and to an AC power outlet. Turn on the power at the power source.
Confirm that the power supply AC OK and PS OK LEDs are green.
Repeat the steps to install a second power supply.
When you install the second power supply the LEDs on the power supply might blink momentarily.Note
Finding the Serial Number
If you contact Cisco Technical Assistance, you need to know the switch serial number. You can also use the show version privileged EXEC command to see the switch serial number.
Figure 5: 1025-W AC Power Supply Serial Number
OL-30278-02 5
Catalyst 6800IA Switch Hardware Installation Guide
Page 6
Finding the Serial Number
Power Supply Installation
Catalyst 6800IA Switch Hardware Installation Guide
6 OL-30278-02