Installing, starting up, and servicing this equipment can
be hazardous due to system pressures, electrical components
and equipment location (elevated structures, etc.).
Only trained, qualified installers and service mechanics
should install, start up, and service this equipment.
Untrained personnel can perform basic maintenance functions such as cleaning coils, and cleaning and replacing
filters. All other operations should be performed by trained
service personnel.
When working on the equipment, observe precautions in
the literature and on tags, stickers, and labels attached to the
equipment.
• Follow all safety codes.
• Wear safety glasses and work gloves.
• Use care in handling, rigging, and setting bulky
equipment.
Be sure all power to equipment is shut off before performing maintenance or service. More than one disconnect may be present.
PRE-INSTALLATION
Moving and Storage —
storage site, use a fork truck. Do not stack units more than
2 high during storage. If unit is to be stored for more than
2 weeks before installation, choose a level, dry storage site
free from vibration. Do not remove plastic wraporskidfrom
unit until final installation.
To transfer unit from truck to
Rigging — All 40RM Series units can be rigged by us-
ing the shipping skid. Units are shipped fully assembled. Do
not remove shipping skids or protective covering until unit
is ready for final placement; damage to bottom panels can
result. Use slings and spreader bars as applicable to lift unit.
INSTALLATION
General —
service clearanceandairflow.Forunits equipped withan economizer, refer to the accessory installation instructions for additional clearance requirements. Be sure floor, wall, or ceiling can support unit weight (Tables 1A-1F). See
Fig. 1A-1C for dimensions.
Allow 21⁄2ft at front and side of unit for
Uncrating — Move unit as near as possible to final lo-
cation before removing shipping skid.
Remove metal banding, top skid, and plastic wrap. Examine unit for shipping damage. If shipping damage is
evident, file claim with transportation agency. Remove base
skid just prior to actual installation.
Check nameplate information against available power
supply and model number description in Fig. 2.
Accessories — Refer to instructions shipped with each
accessory for specific information.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 3c 2e
PC 111Catalog No. 534-053Printed in U.S.A.Form 40RM-9SIPg 111-95Replaces: 40RM-1SI
Table 1A — 40RM Physical Data, English
UNIT 40RM007008012014016024028034
22503750
1...11⁄
8
2
2
2
2
1
⁄
2
8
10121⁄
30005000
2...11⁄
8
1...11⁄
2
1...11⁄
2
3750-
6250
2...11⁄
2
15202530
45007500
8
2...11⁄
1
⁄4ODM/1 IDF
4...16 x 20 x 2
4...16 x 24 x 2
8
2...5⁄
1...21⁄
1...11⁄
6,000-
10,000
2...11⁄
8
2
2
1...2
1...2
7,500-
12,500
8
2...13⁄
4...20 x 24 x 2
4...20 x 25 x 2
9,000-
15,000
8
2...13⁄
NOMINAL CAPACITY (Tons)67
OPERATING WEIGHT (lb)
Base Unit with TXV38138540567068569010201030
Plenum979797140140140180180
Airflow Range (cfm)
Nominal Motor Hp (Standard Motor)
208/230-1-601.32.4——————
208/230-3-60 and 460-3-602.42.42.42.93.75.07.510.0
575-3-601.02.02.03.03.05.07.510.0
230-3-50, 400-3-502.42.42.92.92.95.07.510.0
Motor Speed (rpm)
208/230-1-6017251725——————
208/230-3-60 and 460-3-6017251725172517251725174517451745
575-3-6017251725172517251725174517551755
230-3-50, 400-3-5014251425142514251425142514251425
REFRIGERANTR-22
Operating charge (lb)
(approx per circuit)*
DIRECT-EXPANSION COILEnhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (psig)435
Face Area (sq ft)6.678.3310.013.2517.6719.8824.8629.83
No. of Splits112222 2 2
No. of Circuits per Split12159912131518
Split Type...Percentage——Face...50/50
Rows...Fins/in.3...153...153...173...153...153...173...153...15
STEAM COIL
Max Working Pressure (psig at 400 F)175
Total Face Area (sq ft)6.676.676.6713.3313.3313.3315.015.0
Rows...Fins/in.1...91...91...91...101...101...101...101...10
HOT WATER COIL
Max Working Pressure (psig)150
Total Face Area (sq ft)6.676.676.6713.3313.3313.3315.015.0
Rows...Fins/in.2...8.52...8.52...8.52...8.52...8.52...8.52...12.52...12.5
Water Volume
(gal)8.313.914.3
3
(ft
)1.11.851.90
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)1...1
DX Coil — Liquid Refrigerant (ODF)1...5⁄
Steam Coil, In (MPT)1...21⁄
Steam Coil, Out (MPT)1...11⁄
Hot Water Coil, In (MPT)1...11⁄
Hot Water Coil, Out (MPT)1...11⁄
Condensate (PVC)1...1
18003000
3.03.01.5/1.52.0/2.02.5/2.53.5/3.54.5/4.55.0/5.0
1
⁄
8
FILTERSThrowaway — Factory Supplied
Quantity...Size (in.)4...16 x 24 x 2
Access LocationEither Side
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
8
2
Table 1B — 40RMQ Physical Data, English
UNIT 40RMQ008012016
NOMINAL CAPACITY (Tons)7
OPERATING WEIGHT (lb)
Base Unit with TXV385427713
Plenum9797140
FANS
Qty...Diam. (in.)1...151...152...15
Nominal Airflow (cfm)300040006000
Airflow Range (cfm)2250-37503000-50004500-7500
Nominal Motor Hp (Standard Motor)
208/230-1-602.4——
208/230-3-60 and 460-3-602.42.43.7
575-3-602.02.03.0
230-3-50, 400-3-502.42.92.9
Motor Speed (rpm)
208/230-1-601725——
208/230-3-60 and 460-3-60172517251725
575-3-60172517251725
230-3-50, 400-3-50142514251425
REFRIGERANTR-22
Operating charge (lb)
(approx per circuit)*
DIRECT-EXPANSION COILEnhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (psig)435
Face Area (sq ft)8.3310.017.67
No. of Splits12 2
No. of Circuits per Split15916
Split Type...Percentage—Face...50/50
Rows...Fins/in.3...154...154...15
STEAM COIL
Max Working Pressure (psig at 400 F)175
Total Face Area (sq ft)6.676.6713.33
Rows...Fins/in.1...91...91...10
HOT WATER COIL
Max Working Pressure (psig)150
Total Face Area (sq ft)6.676.6713.33
Rows...Fins/in.2...8.52...8.52...8.5
Water Volume
(gal)8.313.9
3
(ft
)1.11.85
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)1...1
DX Coil — Liquid Refrigerant (ODF)1...5⁄
Steam Coil, In (MPT)1...21⁄
Steam Coil, Out (MPT)1...11⁄
Hot Water Coil, In (MPT)1...11⁄
Hot Water Coil, Out (MPT)1...1
Condensate (PVC)1...11⁄4ODM/1 IDF
FILTERSThrowaway — Factory Supplied
Quantity...Size (in.)4...16 x 24 x 2
Access LocationEither Side
1
⁄
2
1015
3.02.0/2.03.0/3.0
1
⁄
8
8
2
2
2
1
⁄
2
2...11⁄
2...5⁄
1...11⁄
1...11⁄
8
8
1...21⁄
1...11⁄
2
2
2...11⁄
2...5⁄
2
2
1...2
1...2
4...16 x 20 x 2
4...16 x 24 x 2
8
8
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
3
Table 1C — 40RMS Physical Data, English
UNIT 40RMS008010012014016024028034
NOMINAL CAPACITY (Tons)7
OPERATING WEIGHT (lb)
Base Unit39039139166167768310351042
Plenum979797140140140180180
FANS
Qty...Diam. (in.)1...151...151...152...152...152...152...182...18
Nominal Airflow (cfm)30003400400050006000800010,00012,000
Airflow Range (cfm)2250-3750 2250-42503000-50003750-62504500-7500 6000-10,000 7500-12,500 9000-15,000
Nominal Motor Hp
(Standard Motor)
208/230-1-602.42.4——————
208/230-3-60 and 460-3-602.42.42.42.93.75.07.510.0
575-3-602.02.02.03.03.05.07.510.0
230-3-50 and 400-3-502.42.42.92.92.95.07.510.0
Motor Speed (rpm)
208/230-1-6017251725——————
208/230-3-60 and 460-3-6017251725172517251725174517451745
575-3-6017251725172517251725174517551755
230-3-50 and 400-3-5014251425142514251425142514251425
CHILLED WATER COILEnhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure
(psig)
Face Area (sq ft) — Upper8.39.04.98.38.311.012.415.5
Face Area (sq ft) — Lower——4.95.58.38.312.412.4
Rows...Fins/in.3...15
STEAM COIL
Max Working Pressure
(psig at 400 F)
Total Face Area (sq ft)6.676.676.6713.3313.3313.3315.015.0
Rows...Fins/in.1...91...91...91...101...101...101...101...10
HOT WATER COIL
Max Working Pressure
(in. wg)
Total Face Area (sq ft)6.676.676.6713.3313.3313.3315.015.0
Rows...Fins/in.2...8.52...8.52...8.52...8.52...8.52...8.52...12.52...12.5
Water Volume
(gal)8.313.914.3
3
(ft
)1.11.851.90
PIPING CONNECTIONS,
Quantity...Size (in.)
Chilled Water — In1...1
Chilled Water — Out1...1
Steam Coil, In (MPT)1...21⁄
Steam Coil, Out (MPT)1...11⁄
Hot Water Coil, In (MPT)1...11⁄
Hot Water Coil, Out (MPT)1...11⁄
Condensate (PVC)1...11⁄4ODM/1 IDF
FILTERSThrowaway — Factory Supplied
Quantity...Size (in.)4...16 x 24 x 2
Access LocationEither Side
UNIT 40RM007008012014016024028034
NOMINAL CAPACITY (kW)21263543527087105
OPERATING WEIGHT (kg)
Base Unit with TXV173175184304311313463467
Plenum4444446363638282
FANS
Qty...Diam. (mm)1...3811...3811...3812...3812...3812...3812...4572...457
Nominal Airflow (L/s)11331604188823602831377547195663
Airflow Range (L/s)850-1416 1203-2006 1416-2360 1770-2949 2124-3539 2831-4719 3539-5899 4247-7079
Nominal Motor kW (Standard Motor)
208/230-1-600.971.79——————
208/230-3-60 and 460-3-601.791.791.792.162.763.735.607.46
575-3-600.751.491.492.242.243.735.607.46
230-3-50, 400-3-501.791.792.162.162.163.735.607.46
Motor Speed (r/s)
208/230-1-6028.828.8——————
208/230-3-60 and 460-3-6028.828.828.828.828.829.129.129.1
575-3-6028.828.828.828.828.829.129.329.3
230-3-50, 400-3-5023.823.823.823.823.823.823.823.8
REFRIGERANTR-22
Operating charge (kg)
(approx per circuit)*
DIRECT-EXPANSION COILEnhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (kPag)2999
Face Area (sq m)0.620.770.930.931.641.852.302.77
No. of Splits11222222
No. of Circuits per Split12159912131518
Split Type...Percentage——Face...50/50
Rows...Fins/m3...5913...5913...6703...5913...5913...6703...5913...591
STEAM COIL
Max Working Pressure (kPag at 204.4 C)1207
Total Face Area (sq m)0.620.620.621.241.241.241.391.39
Rows...Fins/m1...3551...3551...3551...3941...3941...3941...3941...394
HOT WATER COIL
Max Working Pressure (kPag)1034
Total Face Area (sq m)0.620.620.621.241.241.241.391.39
Rows...Fins/m2...3352...3352...3352...3352...3352...3352...4932...493
Water Volume
(L)31.452.654.1
3
(m
)0.0310.0520.054
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)1...1
DX Coil — Liquid Refrigerant (ODF)1...5⁄
Steam Coil, In (MPT)1...21⁄
Steam Coil, Out (MPT)1...11⁄
Hot Water Coil, In (MPT)1...11⁄
Hot Water Coil, Out (MPT)1...1
Condensate (PVC)1...11⁄4ODM/1 IDF
FILTERSThrowaway — Factory Supplied
Quantity...Size4...406 x 610 x 51
Access LocationEither Side
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
UNIT 40RMQ008012016
NOMINAL CAPACITY (kW)263552
OPERATING WEIGHT (kg)
Base Unit with TXV175194323
Plenum444463
FANS
Qty...Diam. (mm)1...3811...3812...381
Nominal Airflow (L/s)160418882831
Airflow Range (L/s)1203-20061416-23602124-3539
Nominal Motor kW (Standard Motor)
208/230-1-601.79——
208/230-3-60 and 460-3-601.791.792.76
575-3-601.491.492.24
230-3-50, 400-3-501.792.162.16
Motor Speed (r/s)
208/230-1-6028.8——
208/230-3-60 and 460-3-6028.828.828.8
575-3-6028.828.828.8
230-3-50, 400-3-5023.823.823.8
REFRIGERANTR-22
Operating charge (kg)
(approx per circuit)*
DIRECT-EXPANSION COIL
Max Working Pressure (kPag)2999
Face Area (sq m)0.770.931.64
No. of Splits122
No. of Circuits per Split15916
Split Type...Percentage—Face...50/50
Rows...Fins/m3...5914...5914...591
STEAM COIL
Max Working Pressure (kPag at 204.4 C)1207
Total Face Area (sq m)0.620.621.24
Rows...Fins/m1...3551...3551...394
HOT WATER COIL
Max Working Pressure (kPag)1034
Total Face Area (sq m)0.620.621.24
Rows...Fins/m2...3352...3352...335
Water Volume
(L)31.452.6
3
(m
)0.0310.052
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)1...1
DX Coil — Liquid Refrigerant (ODF)1...5⁄
Steam Coil, In (MPT)1...21⁄
Steam Coil, Out (MPT)1...11⁄
Hot Water Coil, In (MPT)1...11⁄
Hot Water Coil, Out (MPT)1...1
Condensate (Male PVC)1...11⁄4ODM/1 IDF
FILTERSThrowaway — Factory Supplied
Quantity...Size4...406 x 610 x 51
Access LocationEither Side
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
1.360.91/0.911.36/1.36
1
⁄
8
8
2
2
2
1
⁄
2
2...11⁄
2...5⁄
1...11⁄
1...11⁄
8
8
2
2
1...21⁄
1...11⁄
2...11⁄
8
2...5⁄
1...2
1...2
8
2
2
4...406 x 508 x 51
4...406 x 610 x 51
6
Table 1F — 40RMS Physical Data, SI
UNIT 40RMS008010012014016024028034
NOMINAL CAPACITY (kW)26293543527087105
OPERATING WEIGHT (kg)
Base Unit177177177300307310469473
Plenum4444446363638282
Face Area (sq m) — Upper0.770.840.910.770.771.021.151.44
Face Area (sq m) — Lower———0.510.770.771.151.15
Rows...Fins/m3...5913...5913...5913...5913...5913...5913...5913...591
STEAM COIL
Max Working Pressure
(kPag at 204.4 C)
Total Face Area (sq m)0.620.620.621.241.241.241.391.39
Rows...Fins/m1...3551...3551...3551...3551...3941...3941...3941...394
HOT WATER COIL
Max Working Pressure
(kPag)
Total Face Area (sq m)0.620.620.621.241.241.241.391.39
Rows...Fins/m2...3352...3352...3352...3352...3352...3352...4932...493
Water Volume
(L)31.452.654.1
3
(m
)0.0310.0520.054
PIPING CONNECTIONS,
Quantity...Size (in.)
Chilled Water — In1...1
Chilled Water — Out1...13⁄8ODF 1...13⁄8ODF 2...13⁄8ODF 2...13⁄8ODM 2...13⁄8ODM 2...13⁄8ODM 2...21⁄8ODM 2...21⁄8ODM
Steam Coil, In (MPT)1...21⁄
Steam Coil, Out (MPT)1...11⁄
Hot Water Coil, In (MPT)1...11⁄
Hot Water Coil, Out (MPT)1...11⁄
Condensate (PVC)1...1
FILTERSThrowaway — Factory Supplied
Quantity...Size (mm)4...406 x 610 x 51
Access LocationEither Side
6. 40RMS units may require alternate or
additional field-fabricated piping access holes.
UNIT WEIGHT
lb (kg)
*YC and WD option codes for all 034 size units and 008, 010 units with 208/230-1-60
power designate standard motor and high-static drive.
NOTE: See the following table for the sizes available for each unit.
UNIT007008010012014016024028034
40RMXXXXXXXX
40RMQXXX
40RMSXXXXXXXX
Fig. 2 — Model Number Nomenclature
Unit Positioning — The unit can be mounted on the
floor for vertical application with return air entering the face
of the unit and supply air discharging vertically through the
top of the unit. The unit can also be applied in a horizontal
arrangement with return air entering horizontally and the supply air discharging horizontally. When applying the unit in
a horizontal arrangement, ensure the condensate drain pan is
located at the bottom center of the unit for adequate condensate disposal. See Fig. 3 for condensate connections for
each unit position.
Typical positioning and alternate return air locations are
shown in Fig. 3.Alternate return air locations can be used by
moving the unit panel from the alternate return air location
to the standard return air location.
IMPORTANT: Do NOT attempt to install unit with
return air entering top panel of unit. Condensate will
not drain from unit.
LEGEND
Accessory Line
Alternate Air Intake and Discharge
Air Intake and Discharge
Fig.3—Typical Unit Positioning
11
Unit Isolation — Where extremely quiet operation is
essential, install isolators between floor and base of unit, or
between ceiling and top section of unit.
Be sure that unit is level and adequately supported. Use
channels at front and sides of unit for reference points when
leveling.
Refrigerant and Chilled Water PipingAccess —
The 40RM Series units come with standard knockouts for
refrigerant and chilled water piping. These knockouts are located on both sides of the unit for installation flexibility. The
standard knockouts provide sufficientaccess to the unit’s coils
for all 40RM and some 40RMQ units, however, for40RMQ016
and 40RMS units, additional holes must be field-fabricated
to accommodate the piping. See Fig. 4 for the positions and
dimensions of the additional access holes required for these
units, including hole diameters and drilling dimensions. Recommended access hole use is also listed for all units. Note
that Fig. 4 shows the access holes on the control-box side of
the unit; this is the side of the unit with the coil headers, so
it is used most often for piping access.
Refrigerant Piping — See Tables 1A, 1B, 1D, 1E for
refrigerant pipe connection sizes. For ease in brazing, it is
recommended that all internal solder joints be made before
unit is placed in final position.
The 40RM and 40RMQ direct-expansion units have
internal factory-installed thermostatic expansion valves (TXVs),
distributors, and nozzles for use with R-22. See Table 2 for
part numbers. Knockouts are provided in the unit corner posts
for 40RM and 40RMQ008 and 012 refrigerant piping. The
40RMQ016 unit requires additional field-fabricated piping
access holes. See Fig. 4, which also lists recommended knockouts and access holes to use for each 40RM and 40RMQ
unit size. Recommended fittings are listed in Table 3.
The sensor bulb capillary tubes must be routed from the
TXVs inside the unit through one of the piping access holes.
Clamp the TXV sensor bulb on a vertical portion of the suction line, outside the unit. See Fig. 5.
Fig. 4 — Refrigerant and Chilled Water Piping Access Holes
12
FIELD-FABRICATED HOLE POSITION
DIMENSIONS, in. (mm)
IMPORTANT: Never attach the sensor to the suction
manifold. Do NOT mount the sensor on a trapped portion of the suction line.
40RM Series evaporator coils have a face-split design. Ensure that lower circuit of coil is first on/last off when connected to the condensing unit and/or system controls. See
Fig. 6.
ExternalTXV equalizer connections areprovided and factorybrazed into the coil suction manifolds.
If suction line must be horizontal, clamp bulb to suction
line at least 45 degrees above bottom, at approximately the
4 o’clock or 8 o’clock position. See Fig. 7.
NOTE: The 40RMQ units are supplied with factory-installed
thermostatic expansion valves and check valve bypasses.
No extra piping connections or kits are required to install the
40RMQ with a 38AQS condensing unit in a heat pump
system, however, some field supplied components may be
required. See the following two sections.
* Feeder tube size is
NOTE: Hot gas bypass applications require field-supplied auxiliary side connector.
1
⁄4in. (6.35 mm).
TXV
Qty...Part No.
DISTRIBUTOR
Qty...Part No.
FEEDER TUBES
PER DISTRIBUTOR*
Qty...Size (in.)
38AQS008/40RMQ008 HEATPUMP SYSTEM PIPING —
Addition of a liquid solenoid valve (LLSV) is recommended
when the piping system length exceeds 75 feet. The LLSV
must be a bi-flow type suited for use in heat pump systems.
The recommended valve is Sporlan model CB14S2 (5/8-in.
ODF, 7/8-in. ODM) available from the Replacement Components Division as part number EF23JS-214. This solenoid
valve requires Sporlan part no. MKC-2 coils that must be
purchased locally. Wire the solenoid valve in parallel with
the compressor contactor coil.
NOZZLE
Qty...Part No.
The LLSV must be installed at the outdoor unit with the
flow arrow pointed toward the outdoor unit (in-flow
direction for the heating mode.)
FILTER DRIER REQUIREMENTS FOR 38AQS012/
40RMQ012 AND 38AQS016/40RMQ016 HEAT PUMP
SYSTEMS — The 38AQS012 and 016 units do not include filter driers. Filter driers must be field-supplied
and installed in 38AQS012/40RMQ012 and 38AQS016/
40RMQ016 systems. The filter driers used with these systems must be bi-flow types suited for use in heat pump
applications.The Replacement Component Division part numbers listed in Fig. 8 are recommended and available for field
installation.
LEGEND
TXV — Thermostatic Expansion Valve
RECOMMENDED FILTER DRIERS*
(38AQS012,016/40RMQ SYSTEMS)
LIQUID
UNIT
38AQS
012
016
*Available from Carrier Replacement Components Division.
LINE
SIZE
PART NO.
(in.)
1
⁄2P504-8084S2A
5
⁄8P504-8165S1B
1
⁄2P504-8084S2A
5
⁄8P504-8085S2A
QUANTITY
REQUIRED
REFERENCE
FIGURE
Fig. 8 — Filter Drier Requirements —
38AQS012/40RMQ012 and 38AQS016/40RMQ016
Heat Pump Systems
14