Canon iR1600, iR2000 Service Bulletin 004

Service Bulletin
Issued by Canon Europa N.V.
COPIER
Model : No.:
Subject :
Reason :
Details :
iR1600/iR2000 (230V only)
DATE:
iR1600/iR2000
ADDITION OF INSTALLATION PROCEDURE
The baud rate for the serial communication with the PCL board has not correctly been set except for EUROPE and USA under TYPE.
CorrectionMade
Unless EUROPE or USA is selected for TYPE, an error will occur inthe communication with the PCL board, and pressing the System button will not reset the error and the indication ‘I/O INITIALIZING’ will remain.
ROM version. Main:Ver.EC-30-04 PCL:Ver.1.72 NIC:Ver.1.00
iR2000-004 (FF-T01-L7-000015-01)
29.03.02
Cause
The baud rate for the serial communication with the PCL board has not correctly been set except for EUROPE and USA under TYPE.
Temporary Remedy Until the Release of the Updated Software
Correct the procedure used at the time of installationas follows:
1. Execute ALL CLEAR.
2. Select EUROPE for TYPE.
3. For messages, use the following: USER MODE>DISPLAY LANGUAGE.
4. For recording paper, refer to the followingto suit the configuration of paper to use:
-for A-configured paper, use the current settings (i.e., use the default).
-for AB-configured paper, set bit1 of SW14 (SSSW) to ‘0’ while keeping bit0 at ‘0’.
-for Inch-configured paper, set bit1 of SW14 (SSSW) to ‘1’ and bit1 to ‘0’. At the same time, set bit4 of SW06 (SSSW) to ‘1’.
Permanent Measure
The baud rates will be corrected with the release of the EC version of ASSIST scheduled for the end of March.