Canon iR1600, iR2000 Service Bulletin 002

Important
Service Bulletin
Issued by Canon Europa N.V.
COPIER
Model:
Location:
Subject:
Reason:
Detail:
iR1600/iR2000
ServiceManual (FY8-13HJ-000)
Procedure of Replacing Fixing Roller
For better quality and safety, the procedure of replacing the fixing roller described in the Service Manual is changed. Observe the new procedure and replace the fixingroller properly.
Refer to the attached pages.
No.:
iR2000-002 (FF-T01-L7-000008-01)
25.01.02
- 1/7-
CHAPTER 7 FIXING SYSTEM
[2]
[4] [5]
[4] [5]
3.6 Mounting the Fixing Roller/Fixing Heater/Separation Claw
1) Mount the 5 separation claws [1] with the 5 springs.
Check to make sure that the contact plate [2] and bushing [3] is mounted.
2) Open the separation claws [1] to insert the fixing roller [4]. Obtain a sheet of A3/11x17 white paper, fold it in 4, and fit it as shown.
3) With the fixing heater [5] fitted in the fixing roller [4], hold the fixing roller [4] in your hand.
4) With attention to the separation claws [1], force the fixing roller [4] against the paper and place it on the fixing as­sembly.
[3]
F07-306-01
[3]
[1]
7-24
[1]
F07-306-02
[1]
F07-306-03
COPYRIGHT© 2001 CANON INC. 2000 CANON iR1600/iR2000 REV.1 DEC. 2001
CHAPTER 7 FIXING SYSTEM
5) Remove the paper.
6) Mount the fixing heater[7] with two screws[6].
1. Be sure to mount the fixing heater so that its edge with print faces upward. Further, take care not to touch the glass portion of the fixing heater .
2. When mounting the fixing roller, take care not to scratch it by any of the sepa­ration claws.
Check to make sure that the bushing [8] is mounted as shown and that the side [9] on both ends of the bushing are parallel.
[6]
[7]
[7]
F07-306-04
[9]
[8]
F07-306-05
COPYRIGHT© 2001 CANON INC. 2000 CANON iR1600/iR2000 REV .1 DEC. 2001
7-25
Loading...