Important
Service Bulletin
Issued by Canon Europa N.V.
COPIER
Model:
Location:
Subject:
Reason:
Detail:
iR1600/iR2000
ServiceManual (FY8-13HJ-000)
Procedure of Replacing Fixing Roller
For better quality and safety, the procedure of replacing the fixing roller described in the Service
Manual is changed. Observe the new procedure and replace the fixingroller properly.
Refer to the attached pages.
No.:
DATE:
iR2000-002
(FF-T01-L7-000008-01)
25.01.02
- 1/7-
CHAPTER 7 FIXING SYSTEM
3.6 Mounting the Fixing Roller/Fixing Heater/Separation Claw
1) Mount the 5 separation claws [1] with
the 5 springs.
Check to make sure that the
contact plate [2] and bushing
[3] is mounted.
2) Open the separation claws [1] to insert
the fixing roller [4]. Obtain a sheet of
A3/11x17 white paper, fold it in 4, and
fit it as shown.
3) With the fixing heater [5] fitted in the
fixing roller [4], hold the fixing roller
[4] in your hand.
4) With attention to the separation claws
[1], force the fixing roller [4] against
the paper and place it on the fixing assembly.
[3]
F07-306-01
[3]
[1]
7-24
[1]
F07-306-02
[1]
F07-306-03
COPYRIGHT© 2001 CANON INC. 2000 CANON iR1600/iR2000 REV.1 DEC. 2001
CHAPTER 7 FIXING SYSTEM
5) Remove the paper.
6) Mount the fixing heater[7] with two
screws[6].
1. Be sure to mount the fixing
heater so that its edge with
print faces upward.
Further, take care not to
touch the glass portion of the
fixing heater .
2. When mounting the fixing
roller, take care not to
scratch it by any of the separation claws.
Check to make sure that the
bushing [8] is mounted as
shown and that the side [9] on
both ends of the bushing are
parallel.
[6]
[7]
[7]
F07-306-04
[9]
[8]
F07-306-05
COPYRIGHT© 2001 CANON INC. 2000 CANON iR1600/iR2000 REV .1 DEC. 2001
7-25