Canon iR1210, iR1230, iR1270F, iR1310, iR1330 ir1200s-012

...
Canon Service Bulletin COPIER
Issued by Canon Europa N.V.
Model: iR1210
iR1230 iR1270F
Location:
Developing Unit
Subject:
Preventing drum unit claws used to attach developing unit from being broken
Detail: <Symptom>
The drum unit claws [1] used to attach the developing unit are broken when P kit is drawn out from the main unit.
Ref No.:
iR1200S-012 (F1-T01-0L6-10004-01)
Date:
24-09-04
F-1
[1] Claws used to attach the developing unit
<Cause>
There are cases where the drum unit claws used to attach the developing unit are leaning inside. If P kit is drawn out from the main unit in this case, one of the pressure arms is accidentally disconnected, detaching the developing unit from the drum unit on the skew. Further, und ue force is app lied to th e drum uni t claw t hat the pressure arm is still attached at this time, leading to broken of the claw.
(1/3)
iR1200S-012
<Factory Measure>
The shape of the pressure arms is changed and the shape circled in red in the fig. below is newly added to prevent the developing unit from being detached from the drum unit even when the drum unit claws are leaning inside.
F-2
[2]: Pressure arm
Service Work:
Even if the drum unit has the previous-type pressure arms, the following steps can prevent the drum unit claws [1] from being broken when P kit is drawn out from the main unit.
1.Draw out P kit from the main unit slowly.
2.Stop drawing it out when light blue areas ("PUSH" is written) of the pressure arms appear, and check to see if both pressure arms are properly attached. (As shown in the fig. below, metallic shafts are found at both edges of the light blue area if the pressure arm is not properly attached.)
F-3
[3]: Light blue area of the pressure arm ("PUSH" is written) [4]: Metallic shafts at both edges of the light blue area
(2/3)