Canon GP405, GP605, GP160, Gp-335, Gp-605v Service Bulletin gp405-04

...
Service Bulletin
Issued by Canon Europa N.V.
COPIER
Model :
Location :
Subject :
Reason :
GP405/335
No.:
GP405-004 (FF-T01-J7-000019-01)
DATE:
04.06.99
IMAGE PROCESSER PCB ASSEMBLY
UPDATING PROM PROGRAM (DC VER. 24)
To communicate information on DC software upgrade which was performed in order to prevent the occurre nce of E001 af ter going into the sleep mode. (DC Ver. 24) Furthermore, this version only works in combination with IP Ver. 37 and later.
[History of ROM modifications]
Service Bulletin
GP405-003 Ver. 37 Ver. 23 Changing specifications,
Ver. No.
IP DC
___
Ver. 24
Correct i on of E001
Correcting bugs, Accommodating FAX functions in some of 230V areas
Description
GP405-001 Rev. 1 Ver. 30 Ver. 22 PS-PCL board compatibility /
correction of faults
Ver. 22.02 Ver. 20 Correction of scrambled
characters in display of French, German and Italian.
Ver. 22.01 Correction of faults
___
Ver. 21 Production approval
Version
-
1 / 2 -
GP405-004
g
Details :
Service Parts :
<Modifications in DC Ver. 24 >
Defect Corrections
No. Item Description
1
Correction for E001 during sleep
There is a possibility (this is confined to the case of going into the sleep mode) that the SSR used to deliver current to the fixing heater remains turned On when the fixing heater relay turns Off. As the consequence of this situation, there would be a load to the fixing heater relay next time this relay is turned On, and in the worst case, fusing of the contact would follow. When such fusing occurs at the same time the SSR is turned On, E001-0001 (detection of abnormal rise in the fixing heater temperature) would follow. To overcome this situation, a sequence in the program has been added to ensure that the SSR turns Off when going into the sleep mode and to also ensure that the SSR is turned Off when the fixing heater relay turns Off.
No. Description Part number Q’ty
1Old
FLASH MEMORY PCB UNIT DC FG3-0504-220 FLASH MEMORY PCB UNIT DC FG3-0504-240
New
10 01
Inter-
chan
ability
No Yes
-- -- -- -- -- -- -- --
e-
950-3
P.C.
Affected machines:
GP405 FRN SNY01241 and later GP405 GER TNY00616 and la ter GP405 UK QNY01723 and later GP405 AMS UNY03720 and later GP405 ITA PNY00411 and later GP335 FRN SNZ01251 and later GP335 GER TNZ00881 and la ter GP335 UK QNZ01968 a nd later GP335 AMS UNZ03919 a nd later GP335 ITA PNZ00411 and later
Destination DC Ver. 24
-
2 / 2 -