Service Bulletin
Issued by Canon Europa N.V.
COPIER
Model :
Location :
Subject :
Reason :
GP605 Series
IMAGE PROCESSER PCB ASSEMBLY/MFC PCB ASSEMBLY
UPGRADING PROM PROGRAM OF IMAGE PROCESSER PCB ASSEMBLY/MFC PCB
ASSEMBLY (IP VER. 20. 11/ MFC VER. 20.05, IP VER. 21.01/MFC VER. 21.02)
To communicate that the image processor PCB / MFC PCB ROM program has been upgraded for full
system finisher compatibility and to correct a malfunction.
[History of ROM modifications]
Service Bulletin Description
Ver. 21.01 Ver. 21.02
Ver. 20.11 Ver. 20.05 Full system finisher compatibility
Ver. No.
IP MFC
No.:
DATE:
IP: Correction of malfunction
MFC: Change to printer compatibility
specifications
GP605-015
(FF-T01-K1-000031-01)
10.09.99
GP605-010 Rev. 1
GP605-003 Rev. 1
_____
Ver. 10.12 Ver. 10.10 IP : For compatibility with LIPS IV
Ver. 7.03 Ver. 7.03 IP : F o r c o m p a t i b ility with PDL kanji
MFC : Correction of faults
Ver. 4.06 Ver. 6.02
Ver. 5.01 Early stage production version
MFC : Correction of faults
-
1 / 4 -

GP605-015
Details :
<Modifications in IP Ver. 20.11 >
No. Item Description
Prevention of cleaner lock In order to prevent locking of the cleaner due to toner blocking, the speed
1
of the fixing feeder fan was changed to full speed.
Also, in order to respond to complaints on noise from users, a mode was
added to switch the fan speed to full speed only in high humidity
environments or when room temperature is 29°C or higher, and to half
speed in normal environments.
Service mode : COPIER/OPTION/BODY/FX-FANSW
0: After printing, controls the fixing fan at full speed
1: Switches to full speed only in high humidity environments or when
room temperature is 29°C or higher, and to half speed in normal
environments
Changed specifications
2
regarding sort/non-sort
when auto-sort is OFF
Dealing with E110 in high
3
altitude (low atmospheric
pressure) environment
Changed output so that tray A output is output from tray B if 1 page data is
flushed out of the printer by sort, because of requests from the field. Also,
compatibility with reverse-direction printing by way of the copy paper
sort/non-sort with an attached header.
Sort: Output to tray B with total face-down delivery
Non-sort: Output to tray A with face-up delivery with one document, and
face-down delivery with multiple documents
A problem was corrected in which the polygon motor was switched
between full and half speed in quiet mode but where rotation would not
drop due to low atmospheric pressure.
<Modifications in MFC Ver. 20.05 >
No. Item Description
Addition of system
1
supervisor password clear
process
Deletion of master
2
password
Setting for time period in
3
which to automatically
delete mail boxes
Prevention of cleaner lock In order to prevent locking of the cleaner due to toner blocking, the speed
4
Correction of malfunction
5
in control panel key
operation
Addition of system supervisor password clear process
Service mode : COPIER/FUNCTION/CLEAR/PWD-CLR
In order to set apart the system supervisor, the only password able to be
entered other than regular passwords is the system supervisor password, so
the master password was removed.
Changed so that the time period for automatic deletion of mail boxes can be
set without the imposition of set period of time.
Service mode : COPIER/OPTION/MB-T-LIM
of the fixing feeder fan was changed to full speed.
Also, in order to respond to complaints on noise from users, a mode was
added to switch the fan speed to full speed only in high humidity
environments or when room temperature is 29°C or higher, and to half
speed in normal environments.
Service mode : COPIER/OPTION/BODY/FX-FANSW
0: After printing, controls the fixing fan at full speed
1: Switches to full speed only in high humidity environments or when
room temperature is 29°C or higher, and to half speed in normal
environments
1) On the sort screen, even if stapling was de-selected, automatic detection
of document orientation was not cleared. This problem was corrected.
2) In the mailbox password setting screen, “Please enter password” was
corrected to “Please set password.”
-
2 / 4 -

<Modifications in IP Ver. 21.01 >
If booklet printing was done with Paper Size=A4/LTR from the
No. Item Description
Correction of
1
malfunction when full
system finisher
connected
PCL driver with a combination of the printer board and the
full system finisher, A4/LTR-H was fed and saddle stitching
not performed. This problem was corrected.
<Modifications in MFC Ver. 21.02 >
No. Item Description
GP605-015
Service Parts :
Change the method of
1
operation for service
mode control panel
check
1) Addition of process to distinguish copying machine and printer models.
2) Correction made so that in the LCD check, the function is stopped by
the clear key, not by the stop key according to the way this is done for
the printer models.
3) Correction made so that, in the LED check, the order of the LED
flashing on and off is done in the same sequence as the flashing on and
off of the printer model’s hard key.
No. Description Part number Q’ty
1Old
2Old
3Old
4Old
IMAGE PROCESSOR PCB FG6-1911-000
IMAGE PROCESSOR PCB FG6-1911-090
New
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1922-000
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1922-210
New
IMAGE PROCESSOR PCB FG6-1952-000
IMAGE PROCESSOR PCB FG6-1952-090
New
IMAGE PROCESSOR PCB FG6-1953-000
IMAGE PROCESSOR PCB FG6-1953-090
New
1→0 905-1
0→1
1→0 905-1
0→1
1→0 905-1
0→1
1→0 905-1
0→1
Inter-
change-
ability
No Yes
No Yes
No Yes
No Yes
P.C.
-- -- -- -- -- -- -- -- --
5Old
New
6Old
New
7Old
New
8Old
New
9Old
New
10 Old
New
IMAGE PROCESSOR PCB FG6-5323-000
IMAGE PROCESSOR PCB FG6-5323-090
MFC PCB ASSEMBLY FG6-1916-000
MFC PCB ASSEMBLY FG6-1916-090
MFC PCB ASSEMBLY FG6-3565-000
MFC PCB ASSEMBLY FG6-3565-090
MFC PCB ASSEMBLY FG6-3566-000
MFC PCB ASSEMBLY FG6-3566-090
MFC PCB ASSEMBLY FG6-1917-000
MFC PCB ASSEMBLY FG6-1917-090
MFC PCB ASSEMBLY FG6-1918-000
MFC PCB ASSEMBLY FG6-1918-090
1→0 905-1
No Yes
0→1
1→0 905-1
No Yes
0→1
1→0 905-1
No Yes
0→1
1→0 905-1
No Yes
0→1
1→0 905-1
No Yes
0→1
1→0 905-1
No Yes
0→1
-
3 / 4 -

GP605-015
No. Description Part number Q’ty
11 Old
12 Old
13 Old
14 Old
15 Old
16 Old
17 Old
MFC PCB ASSEMBLY FG6-1919-000
MFC PCB ASSEMBLY FG6-1919-090
New
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1955-000
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1955-210
New
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1956-000
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1956-210
New
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1957-000
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1957-210
New
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1958-000
DIMM ASS ’Y MBM29F 080-90PFTN FG6-1958-210
New
SY STEM BO X AS SE M B L Y FG6-1961-000
SY STEM BO X AS SE M B L Y FG6-1961-090
New
SY STEM BO X AS SE M B L Y FG6-1962-000
SY STEM BO X AS SE M B L Y FG6-1962-090
New
1→0 905-1
0→1
1→0 905-1
0→1
1→0 905-1
0→1
1→0 905-1
0→1
1→0 905-1
0→1
1→0 900-1
0→1
1→0 900-1
0→1
Inter-
change-
ability
No Yes
No Yes
No Yes
No Yes
No Yes
No Yes
No Yes
P.C.
-- -- -- -- -- -- -- -- --
18 Old
19 Old
20 Old
21 Old
Affected machines:
230V F13-5621 PLE00232 and l ater PLE00232 and later
SY STEM BO X AS SE M B L Y FG6-1963-000
SY STEM BO X AS SE M B L Y FG6-1963-090
New
SY STEM BO X AS SE M B L Y FG6-1964-000
SY STEM BO X AS SE M B L Y FG6-1964-090
New
SY STEM BO X AS SE M B L Y FG6-3563-000
SY STEM BO X AS SE M B L Y FG6-3563-090
New
SY STEM BO X AS SE M B L Y FG6-3564-000
SY STEM BO X AS SE M B L Y FG6-3564-090
New
1→0 900-1
0→1
1→0 900-1
0→1
1→0 900-1
0→1
1→0 900-1
0→1
[IP Ver . 20.11/MFC Ver. 20.05] [IP Ver. 21.01/MFC Ver. 21.02]
F13-5641 PLP00224 and later PLP00254 and later
F13-5651 QLE00946 and later QLE00946 and later
F13-5661 RLE00137 and later RLE00175 and later
F13-5671 SLE 00563 and later SLE00563 and later
F13-5681 TLE00318 and later TLE00318 and late r
F13-5691 ULE01376 and later ULE01376 and later
No Yes
No Yes
No Yes
No Yes
-
4 / 4 -