Campbell Hausfeld PW158010AV User Manual

Lista de Repuestos
Para ordenar repuestos, sírvase llamer al 1-800-330-0712 (En los Estados Unidos, o llame a su distribuidor local)
Electric Pressure Washer
Please read and save these instructions. Read carefully before attempting to assem­ble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
IN463201AV 10/04
© 2004 Campbell Hausfeld
Specifications
PW158010AV 2250 1500 psi 1.5 GPM 13 Amps 120V 100˚F 26 lbs.
Assembly Instructions
Assembly Instructions and Parts List PW158010AV
1. Attach handle with enclosed screws as shown. The longest screw goes
into the top hole of the handle.
2. Assemble wheels by pushing wheel fasteners through wheels and into mounting holes as shown.
3. Attach foot to bottom of pressure washer as shown.
4. Attach high pressure soap lance holder with enclosed screws as shown.
Figure 1
NOTE: REFER TO PRODUCT MANUAL FOR ALL SAFETY INSTRUCTIONS
For parts, product & service information
visit www.chpower.com
Max Pressure Motor Maximum
with Power Inlet
Cleaning Standard Maximum (Single Water Unit
Model Power Lance Capacity Phase) Voltage Temp. Weight
1 * Lanza de jabón de alta presión 1 2 Lanza turbo PM022621AV 1 3 Manguera PM243600AV 1 4 Pistola PM037203AV 1 5 Adaptador de manguito PM022100AV 1 6 Conector rápido PM020600SV 1 7 Limpiador de puntas PM008500AV 1 8 Sujetador de rueda PM342200SV 2 9 Rueda PM342210SV 2 10 Soporte delantero PM270040SV 1 11 Soporte de lanza de jabón de alta presión PM342220SV 1 12 Mango PM342230SV 1 13 Paquete de hardware PM270070SV 1 14 Anillo en O PM232200SV 1
* Para las partes de la lanza de jabón de alta presión, ver el manual para la lanza
de alta presión del jabón IN464701AV 11/04, incluido.
No. de Número del Ref. Descripción Repuesto Ctd.
Longest Screw
1
8
4
2
3
5
6
7
12
11
13
10
8
9
9
13
13
14
14
Sírvase proporcionar la siguiente información:
-Número de modelo
-Número de serie (si lo hubiera)
-Descripción y número del repuesto, según se indica en la lista de repuestos.
Dirija toda la correspondencia a:
Campbell Hausfeld
Attn: Customer Service 100 Mundy Memorial Drive Mt. Juliet, TN 37122 U.S.A.
3. Conecte la manguera de alta presión y el conjunto de pistola en la unidad.
4. Conecte la manguera de jardín según se explica en Instrucciones de conex­ión de la manguera de jardín.
5. Enchufe el cordón de corriente en un tomacorrientes de 120 V con conex­ión a tierra, que se encuentre en un circuito dedicado.
6. Abra la llave del agua.
7. Presione el gatillo y manténgalo pre­sionado por 1 minuto para liberar la presión y remover el aire atrapado en el sistema.
8. Mueva el interruptor "ON/OFF" (“ENCENDIDO/APAGADO”) a la posi­ción "ON" ("ENCENDIDO").
NOTA: PARA OBTENER INSTRUC­CIONES DE OPERACIÓN, CONSULTE EL MANUAL DEL PRODUCTO.
1. Inserte la lanza en la pistola y gírela en el sentido de las agujas del reloj hasta que llegue a su tope, como se muestra en la Figura 4.
2. Verifique que el interruptor de energía esté en la posición "OFF" ("APAGADO").
11 Sp
Figura 5
System Connection
Figura 4 - Conexión de la pistola y lanza
Interruptor "On/Off" (Encendido/ Apagado)
Pistola
Manguera de alta presión
Manguera de jardín
Cable de Corriente Eléctrica Continuación
2. SE DEBE HACER ESTO CADA VEZ QUE LA
UNIDAD SE ENCHUFE EN UN TOMACOR­RIENTE.
Garden Hose Connection
GARDEN HOSE CONNECTION INSTRUCTIONS
1. Attach nipple adapter to inlet fitting on the unit (this may already be attached to the pump).
2. Attach quick connect fitting to garden hose.
3. Pull side “A” of quick connect fitting toward garden hose and push onto nipple adapter.
4. Push side “A” of quick connect fitting towards nipple adapter and release.
Figure 2 - Garden Hose Connection
Quick Connect Fitting
Garden Hose
Nipple Adapter
! IMPORTANT !
This pressure washer is equipped with a microswitch sensitive to water flow. This Instant Start/Stop switch (ISS) senses water flow in the pump. When the trig­ger is released, water stops flowing through the pump. The ISS then auto­matically turns the motor off to protect pump from overheating.
OPERATION
1. Pull trigger on gun.
2. Turn the “ON/OFF” switch to “ON”.
3. Release trigger. The pressure washer motor will stop running.
4. To spray again, pull trigger and motor and pump will restart.
Note: Occasionally the motor may run for a short time to bring fresh, cool water into the pump even if trigger is released. This is part of normal opera­tion and will not damage the unit.
Always turn the
“ON/OFF” switch to “OFF” then trigger gun to release hose pres­sure before unplugging power cord.
Risk of equipment dam-
age. Always make sure the “ON/OFF” switch on the unit is “OFF” and unit is unplugged prior to storage.
Risk of Injection.
Unit will start spraying when trigger is squeezed if on/off switch is in “ON” position. Always point gun in safe direction.
Call 1-800-330-0712
for Technical Service
Assembly Instructions and Parts List PW158010AV
2
www.chpower.com
Power Cord
1. Plug the power cord into a grounded 120V outlet and press the reset button as shown in Figure 3.
2. THIS MUST BE DONE EACH TIME THE UNIT IS PLUGGED IN AN OUTLET.
Figure 3 - Grounded plug/reset button
ENTRADA
SALIDA
"A"
Reset
!
CAUTION
!
CAUTION
!
WARNING
13 mm
OUTLET
INLET