Campbell Hausfeld IN728900AV, CHN70899 User Manual

3-1/2 inch 34˚
MAKES IT EASY TO DO IT LIKE A PRO chpower.com
Framing Nailer
Operating Instructions and Parts Manual
CHN70899
FRANÇAISE: Page 21 ESPAÑOL: Página 41
© 2010 Campbell Hausfeld/Scott Fetzer
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications. . . . . . . . . . . . . . . . . . . . . . . 3
Safety Guidelines. . . . . . . . . . . . . . . . . . . . 4
Safety Symbols. . . . . . . . . . . . . . . . . . . . . . 4
Important Safety Information . . . . . . . . 4
Instructions Pertaining to a Risk of Fire, Electric Shock, or Injury
to Persons. . . . . . . . . . . . . . . . . . . . . . . . . 4
California Proposition 65 . . . . . . . . . . . 4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Work Area. . . . . . . . . . . . . . . . . . . . . . . . . 4
Personal Safety . . . . . . . . . . . . .. . . . . . . 5
Electrical Safety. . . . . . . . . . . . . . . . . . . . 5
Tool Use and Care . . . . . . . . . . . . . . . . . 5
Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Air Source. . . . . . . . . . . . . . . . . . . . . . . . . 6
Unpacking. . . . . . . . . . . . . . . . . . . . . . . . . . 7
Contents. . . . . . . . . . . . . . . . . . . . . . . . . . 7
Additional Items Not Included . . . . . . 7
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Getting To Know Your
Framing Nailer Like A Pro . . . . . .. . . . . . 9
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Anti-Dry Fire . . . . . . . . . . . . . . . . . . . . . . 9
Tethered No-Mar Decking Tip . . . . . . 9
Low Nail Indicator Lights. . . . . . . . . . . 9
Bubble Level . . . . . . . . . . . . . . . . . . . . . . 9
Set-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Lubrication . . . . . . . . . . . . . . . . . . . . . . 10
Minimum Components Required
for Hook-up. . . . . . . . . . . . . . . . . . . . . . 10
Hook-up Instructions For Nailer
to Air Supply . . . . . . . . . . . . . . . . . . . . . 10
Air Hose Requirements. . . . . . . . . . . . 10
Loading / Unloading The Nailer . . . . 11
Loading the Nailer . . . . . . . . . . . . . . 11
Unloading the Nailer . . . . . . . . . . . . 11
Adjusting The Nail Penetration. . . . . 11
Adjusting the Direction
of the Exhaust . . . . . .. . . . . . . . . . . . . . 12
Installing No-Mar Tip . . . . . . . . . . . . . 12
Removing No-Mar Tip . . . . . . . . . . . . 12
Pre-Operation. . . . . . . . . . . . . . . . . . . . . . 12
Operational Modes . . . . . . . . . . . . . . . 12
Sequential Mode. . . . . . . . . . . . . . . . 12
Bump Mode . . . . . . . . . . . . . . . . . . . . 13
Safety Lockout Mode . . . . . . . . . . . . 13
Work Contact Element (WCE). . . . . . 13
Electronics ON / OFF Switch . . . . . . . 13
Operation . . . . . . . . . . . . . . . . . . . . . . . . . 14
Firing the Nailer . . . . . . . . . . . . . . . . . . 14
Low Nail Indicator Lights. . . . . . . . . . 14
Bubble Level . . . . . . . . . . . . . . . . . . . . . 14
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maintenance. . . . . . . . . . . . . . . . . . . . . . . 15
Clearing a Jam from the Nailer . . . . . 15
Nailer Repair . . . . . . . . . . . . . .. . . . . . . 15
Replacement Parts. . . . . . . . . . . . . . . . 15
Battery Replacement. . . . . . . . . . . . . . 15
Assembly Procedure for Seals . . . . . . 15
Technical Service . . . . . . . . . . . . . . . . . 16
Fastener Interchange Information. . 16
Troubleshooting Guide . . . . . . . . . . . . . 17
Replacement Parts List
for Framing Nailer. . . . . . . . . . . . . . 18 - 19
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 20
For parts, product and service information
Visit: www.chpower.com Call : Customer Service at 1-800-543-6400
Address any correspondence to: Campbell Hausfeld Attn: Customer Service
100 Production Drive
Harrison, OH 45030 U.S.A.
Operating Instructions and Parts Manual
Framing Nailer
Description
This nailer is designed for framing, trusses, sub-floors, sheathing, exterior decks, and pallet/create assembly. Features include: convenient rear loading magazine which holds up to 100 nails, tethered no-mar decking tip, quick clear nose, an adjustable depth of drive mechanism, oil free, electronic low nail indicator, in-line magazine, bubble level, anti-dry fire, conversion trigger with safety lockout, rubber comfort grip, swivel plug, and adjustable exhaust.
Specifications
Model CHN70899
Requires: 2.5 Avg SCFM using 16 fasteners per minute at 90 psi
Air Inlet: 1/4 inch NPT
Fastener Size Range:
u 2 inches to 3-1/2 inches long u 0.113 inch to 0.131 inch
shank diameter
u 31° to 34°
Magazine Capacity: 85 to 100 fasteners per load
Weight: 9 lbs. 4 oz.
Length: 21 inches
Height: 14-1/2 inches
Maximum Pressure:
120 psi
Pressure Range: 70 psi to 120 psi
Batteries: Two (2) AAA
Figure 1 - CHN70899 Framing Nailer
Locate model number and date code on magazine and / or tool body. Record below:
Model #: _____________________________
Date Code: ___________________________
Retain these numbers for future reference.
www.chpower.com
3
Operating Instructions and Parts Manual
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger
indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning
indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution
indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice
indicates important information, that if not followed, may cause damage to
equipment.
IMPORTANT: Information that requires special attention.
Safety Symbols
The following Safety Symbols appear throughout this manual to alert you to important safety hazards and precautions.
Wear Eye and Mask Protection
Risk of Falling Wear Eye
Read Manual First
Protection
Risk of Personal Injury
Wear Hearing Protection
CHN70899
Important Safety Information
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
This manual contains important safety, operational and maintenance information. If you have any questions, please call 1-800-543-6400 for customer assistance.
When using tools, basic precautions should always be followed,
including the following:
CALIFORNIA PROPOSITION 65
This product or its power cord may contain chemicals known to the State
of California to cause cancer and birth defects or other reproductive
harm. Wash hands after handling.
You can create dust when you cut, sand, drill or grind
materials such as wood, paint, metal, concrete, cement, or other masonry. This dust often contains chemicals known to cause cancer, birth defects, or other reproductive harm. Wear protective gear.
GENERAL
a. To reduce the risks of electric shock, fire, and injury to persons, read
all the instructions before using the tool. Failure to follow warnings, dangers, and cautions could result in DEATH or SERIOUS INJURY.
b. Be thoroughly familiar with the controls and the proper use of the
equipment. Follow all instructions. Contact your Campbell Hausfeld representative if you have any questions.
c. Only persons well acquainted with these rules of safe operation should be allowed
to use the unit.
Do not operate or allow anyone else to operate the nailer if any warnings
or warning labels are not legible. Warnings or warning labels are located on the nailer magazine and body.
Always assume the nailer contains nails. Respect the tool as a working
implement; no horseplay. Always keep others at a safe distance from the work area in case of accidental discharge of nails. Do not point the tool toward yourself or anyone whether it contains fasteners or not. Accidental triggering of the nailer could result in death or serious personal injury.
Do not make any modifications to the tool without first obtaining
written approval from Campbell Hausfeld. Do not use the nailer if any shields or guards are removed or altered. Do not use the nailer as a hammer. Personal injury or tool damage may occur.
Clean and check all air supply hoses and fittings before connecting the
nailer to an air supply. Replace any damaged or worn hoses or fittings.
Tool performance or durability may be reduced.
WORK AREA
a. Keep the work area clean and well lighted. Cluttered benches and dark areas
increase the risks of electric shock, fire, and injury to persons.
b. Do not operate the tool in explosive atmospheres, such as in the
presence of flammable liquids, gases, or dust. The tool is able to create sparks resulting in the ignition of the dust or fumes.
c. Keep bystanders, children, and visitors away while operating the tool.
Distractions are able to result in the loss of control of the tool.
Risk of Fire
4
www.chpower.com
Risk of Explosion
Risk of Shock
Operating Instructions and Parts Manual
Important Safety Information (Continued)
PERSONAL SAFETY
a. Stay alert. Watch what you are doing and use common
sense when operating the tool. Do not use the tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating the
tool increases the risk of injury to persons.
b. Dress properly. Do not wear loose clothing or jewelry.
Contain long hair. Keep hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair
increases the risk of injury to persons as a result of being caught in moving parts.
c. Do not overreach. Keep proper footing and
balance at all times. Proper footing and balance enables better control of the tool in unexpected situations.
d. Use safety equipment. A dust mask, non-skid safety shoes
and a hard hat must be used for the applicable conditions.
Ensuring that the tool is used
only when the operator and all other personnel in the work area are wearing ANSI Z87 eye protection equipment, and when required, other appropriate protection equipment such as head, hearing and foot protection equipment. Serious eye or permanent hearing loss could result.
e. Always wear hearing protection when using the
tool. Prolonged exposure to high intensity noise
is able to cause hearing loss.
f. Do not attach the hose or tool to your body.
Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts.
g. Always assume that the tool contains fasteners.
Do not point the tool toward yourself or anyone whether it contains fasteners or not.
Do not drop or throw the tool. Dropping
or throwing the tool can result in damage that will make the tool unusable or unsafe. If the tool has been dropped or thrown, examine the tool closely for bent, cracked or broken parts and air leaks. STOP and repair before using or serious injury could occur.
Avoid long extended periods of work with the
nailer. Stop using the nailer if you feel pain in hands or arms.
Hold tool by insulated gripping surface when performing an operation where the tool or fastener may contact hidden wiring. Contacting a “live” wire will make exposed metal parts of the tool “live” and shock the operator.
Never place hands or any other
body parts in the nail discharge area of the nailer. The nailer might eject a fastener and could result in death or serious personal injury.
CHN70899
ELECTRICAL SAFETY
Replace batteries only with same
size batteries. Do not mix old and new batteries. Using wrong size batteries can create a risk of fire or injury.
The front end of the tool may be
made “live” if the tool comes into contact with live wiring in the wall. TO PREVENT ACCIDENTAL ELECTRICAL SHOCK, HOLD TOOL ONLY BY THE SOFT GRIP HANDLE.
TOOL USE AND CARE
a. Do not force the tool. Use the correct tool for the application.
The correct tool will do the job better and safer at the rate for which the tool is designed.
Disconnect the tool from the air source before
making adjustments, doing tool maintenance, clearing jams, touching the safety yoke, leaving work area, loading, or unloading the tool. Such precautionary measures reduce the risk of injury to persons.
b. Store the tool when it is idle out of reach of children and
other untrained persons. A tool is dangerous in the hands of
untrained users.
c. Maintain the tool with care. A properly maintained tool
reduces the risk of problems and is easier to control.
d. Use only those fasteners listed in the “Fastener Interchange
Information” section on page 12 of this manual. Fasteners not identified for use with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool.
e. Always work in a well-ventilated area. Wear OSHA-
approved dust mask.
Always disconnect the tool from the power
source when unattended, performing any maintenance or repair, clearing a jam, loading, unloading , or moving the tool to a new location.
Always fit tool with a fitting or hose coupling
on or near the tool in such a manner that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected. Do not use a check valve or any other fitting which allows air to remain in the nailer. Death or serious personal injury could occur.
Never carry the nailer by the air hose or pull
the hose to move the nailer or a compressor. Keep hoses away from heat, oil and sharp edges. Replace any hose that is damaged, weak or worn. Personal injury or tool damage could occur.
Do not drive a nail on top of other nails. The
nail could glance and cause death or a serious puncture wound.
Do not expose tool to extreme heat.
f. Do not store in locations where the temperature may reach
or exceed 120°F (49°C), such as a metal tool shed, or a car in the summer. This can lead to deterioration of the battery.
www.chpower.com
5
Operating Instructions and Parts Manual
Important Safety Information (Continued)
CHN70899
g. Do not disassemble tool.
h. Remove batteries when storing tool for an extended time.
NOTE: Battery temperature will increase during and shortly
after use. Only use new Alkaline replacement batteries [two (2) AAA
required]. Do not mix old and new batteries. Battery shelf life - the included batteries may be in a slightly
depleted state or dead depending on how long the product has awaited purchase. Do not return product to store for depleted batteries; please call Campbell Hausfeld at 1-800-543-6400 for assistance.
i. Do not modify or alter the nailer or any nailer parts. Do
not use the nailer if any shields or guards are removed or altered. Do not use the nailer as a hammer. Personal injury
or tool damage may occur.
Do not use any type of flammable gases or
oxygen as a power source for the nailer. Use filtered, lubricated, regulated compressed air only. Use of a compressed gas instead of compressed air may cause the nailer to explode which will cause death or serious personal injury.
Never use gasoline or other flammable liquids
to clean the nailer. Never use the nailer in the presence of flammable liquids or gases. Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury.
Do not modify or disable the Work Contact
Element (WCE). Do not tie or tape the WCE or trigger in a depressed position. Death or serious personal injury could result.
Always check that the Work Contact Element
(WCE) is operating properly. A nail could accidentally be driven if the WCE is not working properly. Personal injury may occur.
Do not touch the trigger unless driving nails.
Never attach air line to nailer or carry nailer while touching the trigger. The tool could eject a fastener which will result in death or serious personal injury.
SERVICE
a. Tool service must be performed only by qualified repair
personnel.
b. When servicing a tool, use only identical replacement
parts. Use only authorized parts.
c. Use only the lubricants supplied with the tool or specified
by the manufacturer.
Disconnect air supply and release tension
from the pusher before attempting to clear
jams because fasteners can be ejected from the front of the nailer. Personal injury may occur.
AIR SOURCE
a. Never connect to an air source that is capable of exceeding
200 psi. Over pressurizing the tool is able to result in
bursting, abnormal operation, breakage of the tool or serious injury to persons. Use only clean, dry, regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool. Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air-pressure range.
b. Never use oxygen, carbon dioxide, combustible gases or
any bottled gas as an air source for the tool. Such gases are capable of explosion and serious injury to persons.
Air compressors providing air to the nailer
should follow the requirements established by the American National Standards Institute Standard B19.3-1991; Safety Standard for Compressors for Process Industries. Contact your air compressor manufacturer for information.
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
The DANGER, WARNING, CAUTION, and NOTICE notifications and instructions in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
6
www.chpower.com
Operating Instructions and Parts Manual
CHN70899
Framing Nailer
Operating Instructions
r
e
l
ai
N
g
n
i
am
r
F
Carry Bag
Batteries
Allen Wrenches
3-1/2 inch, 34° nails
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or damaged parts. Make sure to tighten fittings, bolts, etc., before putting unit into service. Check to be sure all supplied accessories are enclosed with the unit. In case of questions, damaged or missing parts, please call 1-800-543-6400 for customer assistance.
CONTENTS
u Framing Nailer u 3-1/2 inch, 34° nails u Batteries u Allen Wrenches u Operating Instructions u Warranty Card u Carry Bag
ADDITIONAL ITEMS NOT INCLUDED
u Compressor (must be able to maintain
a minimum of 70 psi when the nailer is being used)
u Air hose u Small tool for clearing jams u Threadlock glue u ANSI Z87 eye protection
u Hearing protection and other personal
protective equipment as required
Figure 2
Assembly
This tool comes fully assembled.
www.chpower.com
7
Operating Instructions and Parts Manual
Glossary
Become familiar with these terms before operating the unit.
ACTUATE (TOOL) — To cause movement to the tool’s component(s) intended to drive the fastener.
ACTUATION SYSTEM — The use of a trigger, work contact element (WCE) and/ or other operating control, separately or in combination or sequence, to actuate the tool.
CHN70899
AIR INLET — The opening in which the compressed air supply is connected, usually by means of a threaded fitting.
FASTENERS — The nailer uses fasteners ranging from 2 inches to 3-1/2 inches long, from 0.113 inch to 0.131 inch in shank diameter, and from 31° to 34°.
MAGAZINE — The part of the nailer that holds the Fasteners.
MAXIMUM AIR PRESSURE — The maximum allowable pressure of compressed
air, as specified by the manufacture, for operating the tool.
NO-MAR DECKING TIP — The no-mar decking tip is designed to eliminate marks caused by the serrated Work Contact Element (WCE). The no-mar tip may be removed and tethered to the tool if not required (See REMOVING NO-MAR DECKING TIP) or when a slightly deeper countersink is preferred. Simply slide the no-mar off the WCE and attach to the retainer on the magazine. Use tool in single cycle mode (SEE OPERATIONAL MODES) when no-mar tip is in place (see Figure 5).
psi (POUNDS PER SQUARE INCH) —Measurement of the pressure exerted by the force of the air. The actual psi output is measured by a pressure gauge on the compressor.
QUICK COUPLER — A quick coupler is designed to work in combination with a quick plug to quickly and easily join a pneumatic tool to an air hose (see Figure 3).
QUICK PLUG — A quick plug is designed to work in combination with a quick coupler to quickly and easily join a pneumatic tool to an air hose (see Figure 4).
Figure 3 - Quick Coupler
Figure 4 - Quick Plug
Figure 5 - No-mar Decking Tip
REGULATOR — A device used to control air pressure to an air operated tool
THREAD LOCK GLUE — A locking glue that is applied to the screw threads
before installing. Prevents the screws from working loose during tool operation.
8
www.chpower.com
Operating Instructions and Parts Manual
Getting To Know Your Framing Nailer Like A Pro
CHN70899
Bubble Level
Adjustable Exhaust Deflecter
Trigger
Rubber Comfort Grip
Swivel Plug
Low Nail Indicator Light
Conversion Switch
Adjustable Depth Control Knob
Electronics ON / OFF Switch
Magazine
Work Contact Element (WCE)
Pull-out Warning Decal
Tethered No-mar Decking Tip
Quick Clear Nose Lever
Battery Cover/ Compartment
Low Nail Indicator Light
Features
ANTI-DRY FIRE
This tool is equipped with an Anti-Dry Fire feature. This prevents the Work Contact Element (WCE) from being pushed in when only a few nails remain. Simply load new nail clip behind
remaining nails to continue shooting.
TETHERED NO-MAR DECKING TIP
The tool is fitted with a no-mar tip which is tethered to the tool to prevent loss when not mounted to tool. To utilize the no-mar tip, simply slide it over the tools WCE.
LOW NAIL INDICATOR LIGHTS
The tool is equipped with lights on either side of the tool near the nose. When the nail count becomes low, the lights will turn yellow. When the nail count is nearly out, the Anti-Dry Fire feature will engage and the lights will turn red. (See Loading the Nailer section).
BUBBLE LEVEL
The tool is equipped with a bubble level located on the head cap. This will assist in alighning the tool for level driving of the fastener. The bubble level will assist in vertical and horizontal positioning of the tool.
No-mar Tip Storage
Pusher Latch Button
Nail Pusher
Figure 6 - Components of the Framing Nailer
Nail Loading Area
www.chpower.com
9
Operating Instructions and Parts Manual
Set-Up
CHN70899
LUBRICATION
This nailer requires NO lubrication for normal operation. However, lubrication will NOT harm the tool.
The work surface can become damaged by excessive lubrication.
MINIMUM COMPONENTS REQUIRED FOR HOOK-UP
AIR COMPRESSOR: The air compressor must be able to maintain a minimum of 70 psi when the nailer is being used. An inadequate air supply can cause a loss of power and inconsistent driving (see Chart 1).
PRESSURE REGULATOR: A pressure regulator is required to control the operating pressure of the nailer between 70 psi and 120 psi.
AIR SUPPLY HOSE: ALWAYS use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source, or 150 psi, whichever is greater. Use 3/8 inch air hose for runs up to 50 feet. Use 1/2 inch air hoses for 50 ft. run or longer (see Figure 7 and Chart 2).
HOOK-UP INSTRUCTIONS FOR NAILER TO AIR SUPPLY
Figure 8 shows the recommended hookup for the nailer. NOTE: For better performance, install a 3/8 inch quick plug (1/4 inch NPT threads) with
an inside diameter of 0.315 inch (8 mm) on the nailer and a 3/8 inch quick coupler on the air hose.
1. With ON/OFF switch in OFF position, plug compressor into electrical outlet.
2. Close pressure regulator by turning all the way to the left. Turn compressor ON and let it pump all the way up to automatic shut-off pressure.
3. Attach air hose to regulator outlet. Adjust pressure regulator by turning to the right so that outlet pressure is between 70 psi to 120 psi.
4. Load fasteners into nailer (See Loading/Unloading the Nailer section on page 11).
5. Point the nailer in a safe direction while attaching to air hose.
6. Nailer is ready for use. You may need to adjust outlet pressure to achieve proper fastener depth.
70 psi Minimum
120 psi Maximum
Chart 1
Rated 150 psi or greater
Interior Diameter
Figure 7 - Air Hose Requirements
AIR HOSE REQUIREMENTS
DIAMETER LENGTH OF RUN
3/8 inch Less than 50 feet 1/2 inch Greater than or equal
to 50 feet
Chart 2
Outlet
Tank
Pressure
Gauge
Regulator
Figure 8 - Recommended Hookup
10
www.chpower.com
Pressure
Gauge
Regulator
Outlet
Quick
Coupler
Quick
Plug
Quick
Coupler
Air
Hose
Swivel
Plug
Operating Instructions and Parts Manual
Set-Up (Continued)
LOADING / UNLOADING THE NAILER
Always disconnect the tool from the air supply before loading / unloading fasteners. Choose which type of fastener you want to use for you project. Additional fasteners can be found at major home centers.
Loading the Tool
1. Load strips of fasteners into the slot in the rear of the magazine. Make sure that the nails are placed into tool at the proper orientation.
2. Press pusher bypass button and drag pusher over nail clip. Release pusher.
3. Reconnect tool to air supply.
Unloading the Tool
1. Always unload all fasteners before removing tool from service.
2. Pull pusher back away from nail clip. Press pusher bypass button and allow pusher to ride over remaining nails.
3. Hold tool upright so nails will slide backwards toward magazine slot.
4. Remove nails.
ADJUSTING THE NAIL PENETRATION
The CHN70899 is equipped with an adjustable depth of drive feature. This allows the user to determine how deep a fastener will be driven into the work surface.
1. Adjust the operating pressure to a pressure which will consistently drive the fasteners. Do not exceed the maximum operating pressure of 120 psi.
2. Pull red pin out. Twist Work Contact Element (WCE) 1/4 turn as shown. Release red pin. See Figure 10.
3. Move WCE back and forth to the extent desired. Move the WCE toward the tool to increase nail depth. Move WCE away from tool to reduce nail depth. See Figure 11.
4. Twist WCE 1/4 turn back to its original position as shown. See Figure 12.
5. Make sure that the trigger and WCE move freely up and down without binding or sticking after each adjustment.
CHN70899
Figure 9 - Loading the Nailer
Figure 10 - Nail Depth Adjust
Figure 11 - Nail Depth Adjust
Figure 12 - Nail Depth Adjust
www.chpower.com
11
Operating Instructions and Parts Manual
Set-Up (Continued)
ADJUSTING THE DIRECTION OF THE EXHAUST
The CHN70899 is equipped with an adjustable direction exhaust deflector. This is intended to allow the user to change the direction of the exhaust. Simply twist the deflector to any direction desired.
INSTALLING NO-MAR TIP
1. Disconnect air supply from nailer.
2. Remove no-mar tip from storage post.
3. Remove retaining ring from no-mar tip.
4. Carefully place no-mar tip over the end of work contact element. Position tip onto WCE making certain serrated gooves on each piece are in line and fit snugly together.
5. Position retaining ring on no-mar tip and press firmly in place.
6. Check that the WCE and trigger move up and down freely without sticking or binding.
REMOVING NO-MAR TIP
1. Disconnect air supply from nailer.
2. Remove no-mar tip retaining ring.
3. Pry no-mar tip away from the work contact element.
4. Replace retaining ring onto no-mar tip, then store tip on storage post for future use.
CHN70899
Figure 13 - Exhaust Adjustment
No-mar Tip
Storage Post
Figure 14 - No-mar Tip
Storage Post
Pre-Operation
OPERATIONAL MODES
Always know the operational mode of the nailer before using. Failure to
know the operational mode could result in death or serious injury.
This nailer may be operated in the “Sequential” mode (as supplied by the manufacturer) or “Bump” mode. The tool may be converted from one mode to the other by firmly pressing the conversion switch from one position to the other.
Press the conversion switch on the “
Press the conversion switch on the “ ” side to activate Bump Mode.
Press either side to the middle position to activate the Safety Lockout Mode.
Sequential Mode
This method is recommended when precise nail placement is required. Operation in this mode requires trigger to be pulled each time a nail is driven. Nailer can be actuated by depressing the Work Contact Element (WCE) against work surface followed by pulling the trigger.
The trigger must be released after each fastener is driven to allow tool to reset.
Since the tool can only be actuated by first removing the finger from the trigger, this is considered to be a more restrictive mode of operation, suitable for less experienced users.
” side to activate Sequential Mode.
Figure 15 - Remove No-mar Tip
Depress WCE first...
Work Surface
Then pull trigger.
Work Surface
Figure 16 - Sequential Mode
12
www.chpower.com
Operating Instructions and Parts Manual
Pre-Operation (Continued)
CHN70899
Bump Mode
This method is recommended when less precise nail placement is required. Operation in this mode requires the trigger to be depressed with nailer off of the work surface. Then, the nose of the nailer is tapped against the work surface causing a nail to be driven.
Each time the Work Contact Element is depressed, a nail is driven into the work surface. Extreme care should be taken because a nail will be driven when the WCE is pressed against any surface.
Since the tool can be actuated without removing the finger from the trigger, this is considered to be a less restrictive mode, suitable for more experienced users.
Safety Lockout Mode
When the conversion switch is pressed into the middle position, the trigger is in Safety Lockout Mode. In this mode, no combination of WCE and trigger activations will allow the tool to cycle or fire. If tool does operate while in Safety Lockout Mode, contact Campbell Hausfeld for technical support, and do not use the nailer until repaired.
WORK CONTACT ELEMENT (WCE)
Check the operation of the Work Contact Element (WCE) trip mechanism
before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly. Personal injury may occur.
1. Disconnect the air supply from the nailer.
2. Make sure the trigger and Work Contact Element (WCE) move freely up and down
without sticking or binding.
NOTE: If the tool is not loaded with nails, the anti-dry fire feature will not allow the WCE to be depressed.
3. Reconnect air supply to the nailer.
4. Use a scrap piece of wood as a work surface.
5. Depress the WCE against the work surface without pulling the trigger (See
Figure 18). The nailer MUST NOT OPERATE. Do not use the tool if it operates without pulling the trigger. Personal injury may result.
6. Remove nailer from work surface. The WCE must return to its original down
position. Pull the trigger (See Figure 19). The nailer MUST NOT OPERATE. Do not use the tool if it operates while lifted from the work surface. Personal injury may result.
7. Pull the trigger and depress the WCE against the work surface. The nailer MUST
OPERATE when in bump mode. The nailer MUST NOT OPERATE if in sequential mode.
8. Depress the WCE against work surface. Pull the trigger. The nailer MUST OPERATE.
9. Switch nailer into the other Mode as described in Operational Modes section and
repeat.
Pull trigger first...
Work Surface
Then depress WCE.
Work Surface
Figure 17 - Bump Mode
Work Surface
Figure 18
Work Surface
IMPORTANT: Repeat steps one through nine with tool in Safety Lockout Mode. Tool SHOULD NOT operate at any step. If tool does operate while in Safety Lockout Mode, contact Campbell Hausfeld for technical support.
ELECTRONICS ON / OFF SWITCH
Located on the battery compartment is an ON/ OFF for the tool’s electronic functions and low nail indicator LEDs (See Figure 20).
To utilize the function, turn the battery switch to the “ON” position. To avoid unwanted battery depletion during storage, turn the switch to the “OFF” position.
Figure 19
Figure 20 - Electronic ON/OFF Switch
www.chpower.com
13
Operating Instructions and Parts Manual
Operation
FIRING THE NAILER
1. Load fasteners (see Loading / Unloading the Nailer section).
2. Connect the air supply to the nailer.
An improperly functioning tool must not be used. Do not actuate
the tool unless the tool is placed firmly against the work piece.
In Sequential Mode
CHN70899
Press the conversion switch to the “
1. Fully depress WCE.
2. Pull trigger. Fastener will be driven into workpiece.
In Bump Mode
Press the conversion switch to the “
1. Remove tool from work surface. DO NOT point tool at yourself or others.
2. Pull trigger.
3. Firmly depress Work Contact element (WCE) against work surface. Tool will cycle.
4. Remove tool from work surface. Move tool to the next area where fastener is to be driven and repeat.
LOW NAIL INDICATOR LIGHTS
The tool is equipped with lights on either side of the tool near the nose. Turn the electronics switch to the ON position. When the nail count becomes 10 or so nails remaining in the magazine, the lights will come on yellow. You may reload at that time (See Loading the Nailer section). When the nail count becomes 5 or so remaining nails, the Anti-Dry Fire will engage and the lights will turn red. You MUST reload at that time.
BUBBLE LEVEL
The tool is equipped with a bubble level located on the head cap. When the gun is in a horizontal driving orientation, a level condition can easily be observed and controlled by simply aligning the tool in such a manner whereas the bubble is between the center markings on the length of the level. The same is true when in a vertically downward driving orientation by aligning the tool such that the bubble is centered in the circular
marking at the top of the level.
” side to activate Sequential Mode.
” side to activate Bump Mode.
Figure 21 - Low Nail Indicator Lights
Figure 22 - Bubble Level
14
www.chpower.com
Operating Instructions and Parts Manual
Storage
The nailer should be stored in a cool dry location.
Maintenance
CLEARING A JAM FROM THE NAILER
1. Disconnect nailer from air supply.
2. Remove all nails from the magazine (See Loading/ Unloading).
3. Press down on the Quick-Clear Nose (QCN) lever to disengage portion of nose barrel (See Figure 23).
4. If necessary, use small hand tools to help free the jammed nail. Sometimes it is necessary to use a hammer and a long, thin screwdriver to force the driver ram back all the way into the gun (See Figure 24).
5. Dump jammed nail out.
6. Release QCN lever.
7. Nail pusher must be in the back lock position.
8. Disconnect air supply and reload (See Loading the Tool section).
NAILER REPAIR
Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.
CHN70899
Figure 23 - Quick Clear Nose Lever
REPLACEMENT PARTS
Use only genuine Campbell Hausfeld service parts. Tool performance,
safety and durability could be reduced if improper parts are used.
When ordering replacement parts, specify by part number.
BATTERY REPLACEMENT
Always disconnect the tool from the power source when unattended,
performing any maintenance or repair, clearing a jam, loading,
unloading, or moving the tool to a new location.
The electronics on the tool (low nail indicator lights) run off of two (2) AAA batteries located in the compartment on the back of the magazine. When the batteries’ power is running low and they need to be replaced, the electronic functions may not work properly or at all. Disconnect the tool from air source. Remove screw and battery compartment cover. Insert two (2) new batteries in the proper orientation. Do not mix old and new batteries. Close cover. Replace screw.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a nailer, the internal parts must be cleaned and lubricated. Parker O­lube or equivalent must be used on all o-rings. Each o-ring must be coated with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots. After reassembling, a few drops of 30W non-detergent oil or equivalent, must be added through the air line one time before normal operational use.
Figure 24
Screw
Figure 25 - Battery Replacement
Figure 26 - Battery Replacement
www.chpower.com
15
Operating Instructions and Parts Manual
Maintenance (Continued)
TECHNICAL SERVICE
For information regarding the operation or repair of this product, please call 1-800-543-6400.
FASTENER INTERCHANGE INFORMATION
Fasteners used in the Campbell Hausfeld CHN70899 Framing Nailer will also work in the following brand units:
• DeWalt D51822 and D51823
• Hitachi NR83AA2
• Paslode F-3505
• Porter Cable FC 350A
• Ridgid R350CHA
• Senco FramePro 701XP and 751XP
CHN70899
16
www.chpower.com
Operating Instructions and Parts Manual
Troubleshooting Guide
Stop using nailer immediately if any of the following problems occur. Serious personal injury could result.
Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
SYMPTOM CAUSE SOLUTION
Air leaking at trigger valve O-rings in trigger valve housing are
damaged
Air leaking between housing and nose
Air leaking between housing and cap
Nailer skips driving nail 1. Worn bumper 1. Replace bumper
Nailer runs slow or has loss of power
Nails are jammed in nailer 1. Guide on driver is worn 1. Replace guide
Low nail indicators not working
1. Damaged O-rings and / or seals 1. Replace O-rings and / or seals
2. Damage to bumper 2. Replace bumper
1. Loose screws 1. Tighten screws
2. Damaged gasket 2. Replace gasket
2. Dirt in nose piece 2. Clean drive channel
3. Dirt or damage prevent nails or pusher from moving freely in magazine
4. Damaged pusher spring 4. Replace spring
5. Inadequate air flow to nailer 5. Check fitting, hose, or compressor
6. Worn O-ring on piston or lack of lubrication
7. Damaged O-ring on trigger valve 7. Replace O-rings
8. Air leaks 8. Tighten screws and fitings
1. Nailer not lubricated sufficiently 1. Lubricate nailer
2. Broken spring in cylinder cap 2. Replace spring
3. Exhaust port in cap is blocked 3. Replace damaged internal parts
2. Nails are not correct type 2. Use only recommended nails
3. Nails are bent 3. Replace with undamaged nails
4. Magazine or nose screws are loose 4. Tighten screws
5. Driver is damaged 5. Replace driver
6. Nails loaded incorrectly 6. Review Loading / Unloading section of manual
1. System power switch not turned on 1. Turn switch on
2. Batteries need to be replaced 2. Replace batteries (see “Changing batteries”
3. Components not properly replaced during re-assembly after customer maintenance
Replace O-rings. Check operation of Work Contact Element (WCE)
3. Clean magazine
6. Replace piston seals
section)
3. Review parts view for assistance in proper re­assembly
CHN70899
www.chpower.com
17
Operating Instructions and Parts Manual
For Replacement Parts or Technical Assistance, Call 1-800-543-6400
Please provide following information: Address any correspondence to:
- Model number Campbell Hausfeld
- Serial number (if any) Attn: Customer Service
- Part description and number as shown in parts list 100 Production Drive
Harrison, OH 45030 U.S.A.
CHN70899
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
20
25
27
28
21
23
12
26
29
22
15
30
19
24
35
37
34
31
33
38
32
40
44
41
36
39
43
42
46
48
49
50
110
109
51
53
52
50
54
45
47
72
103
108
85
69
8 73
75 76
58 59 60
55 56
57
82
104
83
86
70
84
74
63
65
66
87
80 81
35
105
61 62
64
106
50
71
52
98
88
77
79
78
89
90
100
107
67
68
101
50
37
96
92
99
74
94
91
102
97
95
93
35
Figure 25 – Repair Parts Illustration for Air Powered Framing Nailer, model CHN70899AV
18
www.chpower.com
Loading...
+ 42 hidden pages