Brooks Instrument 3750 Specifications

Page 1
DS-VA-MT3750C-eng
April, 2018
Data Sheet
MT3750C Series
Variable Area
Metal Tube Variable Area
Ships in 5 days
Overview
Brooks® MT3750 meter operation is based on the variable area principle. The all metal meter is ideal for a variety of gas and liquid applications. These meters are indispensable where high pressure operating conditions exist.
The primary meter is available in 316L stainless steel construction. But corrosion resistant
materials of construction are available which makes it a perfect t for the metering of
aggressive applications.
A broad range of threaded connection sizes and types provide for exible installations.
The very popular mechanical indicator option does not require power which reduces
installation costs and is a cost-effective solution for ow measurement in hazardous areas. Certied transmitters and alarms both ameproof and instrinsically safe are available for
hazardous installations anywhere in the world.
Product Description
The Brooks wetted parts. The magnetically coupled indicator provides a highly reliable method of
indication. This model is a practical and economical approach to low ow rate indication for high pressure and difcult to handle uids.
Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
®
Ar-MiteTM is a reliable, low ow metal tube owmeter with 316L stainless steel
Flowmeters
Features and Benets
Features Benets
®
Wetted Parts made from Stainless Steel or Monel
Ranges up to 100 I/h or 26 GPH Capable of measuring (very) low ows accurately
High Pressure and Temperature Rating Designed to work safely under difcult conditions
Miniature Size Compact even with process anges
Local Reading, Integral Control Valve, Needle Valve, Transmitter or Alarms, versatile product offering
Certied Ex-proof, Intrinsically safe ATEX, CSA, IECEx and NEPSI Approved
Compatible for a wide range of uids (liquids or gases)
1
Page 2
Product Specications / Capacities
Table 1 MT3750C Specications
Specications MT3750C
Measuring Range See Capacities Table 2
Rangeability 10:1 (most sizes)
Metering Tube 316L (stainless steel) Monel K-500
End Fittings 316L (stainless steel)
Monel K-500
Accuracy 5%, 3%, VDI/VDE class 4, 2.5
Repeatability 1% Full Scale
Scale Silver increments with black background - Aluminum Material (52 mm long), single or dual
Connections 1/4” to 3/4”NPT Female
1/4”, 6 mm tube compression
Floats 316L stainless steel Titanium Gr. II
O-rings Viton® uoroelastomers
PTFE Teon®, Buna-N, Kalrez® 4079 peruoroelastomers, Ethylene Propylene
Protection Category (Indicator only) IP66/67/NEMA 4X, (Alarms) IP65/NEMA 4X, (Transmitter) IP66/67/NEMA 4X
Indicator Housing & Cover Die cast Aluminum (Alloy 380), epoxy paint, glass window
Maximum Fluid Temperature 204°C/400°F (Refer to tables on Page 3)
Maximum Fluid Pressure 1500 PSIG (100 Bar)
4000 PSIG (276 Bar) (No valve, 1/4” NPT only)
Meter Dimensions Refer to Figures on Pages 4, 5 and 6
Model Code Refer to Pages 10, 11 & 12
Pressure Equipment Directive Flowmeter complies under Sound Engineering Practices (SEP)
(PED) 2014/68/EU
RoHS Products conform to the European Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU
Inductive Alarm Switches 1 or 2 inductive switches
Reed Switches 1 or 2 switches
Transmitter 4-20 mA output
Agency Approvals Refer to Tables 6-9
Optional Equipment Cartridge or NRSTM valves
Integrally mounted ow controllers
Table 2 MT3750C Capacities
Meter Flow Range Viscosity Pressure Size Water Air
gph l/h ln/h scfh m3n/h CP mBar Inches WC
0 0.025-0.25 0.096-0.96 4.3-43 0.16-1.6 - 5 12 4.8 1 0.034-0.34 0.13-1.3 5.6-56 0.21-2.1 - 10 12 4.8 2 0.096-0.96 0.36-3.6 13.0-120 0.5-4.9 - 20 12 4.8 3 0.29-2.8 1.0-10 - 1.2-12 0.033-0.33 35 12 4.8 4 0.55-5.5 2.1-21 - 2.5-23 0.063-0.62 70 32 12.8 5 1.1-11 4.2-42 - 5.4-53 0.15-1.3 100 38 15.3 6 2.8-26 11-100 - 12-110 0.31-3.1 130 44 17.7
Notes:
1. Air ows in scfh converted to 70°F and 14.7 psia when the meter is operated at 70°F and 14.7 psia.
2. Air ows in m
3
n/h (converted to normal conditions: 0° and 1.013 bar abs) when the meter is operated at 1.013 bar abs and 20°C.
3. When the viscosity of the uid exceeds the viscosity immunity ceiling (VIC), a calculated correction is applied to account for the difference between factory calibration uid and process uid.
2
(1, 2)
Limit
(3)
Drop
Page 3
Product Specications - Pressure / Temperature and Certications
Product Approvals - 3750
Table 3 MT3750C Pressure Ratings in PSIG (BarG)
Meter Pressure Rating
Type -58°F to 400°F / -50°C to 204°C
Standard Meter 1500 (100)
High Pressure Meter 4000 (276)
Table 4 MT3750C Fluid Temperature at Ambient Temperature
Max. Ambient Max. Fluid Temperature per Option Temperature Indicator Alarm Transmitter
°F °C °F °C °F °C °F °C
-58 -50 -58 to 400 -50 to 204 N/A N/A N/A N/A
-20 -29 400 204 -20 to 250 -29 to 120 -20 to 180 -29 to 82 104 40 400 204 250 120 180 82 110 43 390 199 250 120 175 79 120 49 380 193 250 120 170 76 130 54 370 187 250 120 165 74 140 60 360 182 240 115 155 68 150 65 350 176 235 112 150 65 Notes:
1. Ambient temperature is limited to 150°F (65°C) maximum. Contact factory for ambient temperature > 150°F (65°C)
Table 5 MT3750C Temperature Ratings for Elastomer Materials
Elastomer Minimum Temperature Maximum Temperature
Materials °F °C °F °C
Kalrez 4079 -58 -50 400 204 Viton A 5 -15 400 204
Teon PTFE -58 -50 400 204
Buna -22 -30 250 120
Ethylene Propylene -58 -50 250 120
Table 6 Product Approvals - MT3750C (Reference Tables 7, 8 & 9 for Certications with Transmitter, Reed Switch Alarm and Inductive Alarm)
ApprovalsMark
EU Declaration of Conformity
CRN IP66/67 & NEMA 4X IP66/67 IP65 Type 4X
Explosion safety "Constructional safety (c)"
   
ATEX
Meter Options
Mechanical
Transmitter
Inductive Switch


Declaration/CertificateStandards/Directives/Marking
Alarm
Reed Switch Alarm
EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU) Pressure Equipment Directive (2014/68/EU) ASME B31.1 & ASME B31.3 IEC 60529 & NEMA 250-2014 IEC 60529 IEC 60529 CSA
II 2GD c IIC TX
Special conditions for safe use:
Enclosure contains glass & painted aluminum parts. If it is m ounted in an area where the use of category 2G or 2D apparatus is required, it must be installed such that ignition source due to propagating brush discharge sparks are excluded.
The actual maximum surface temperature of the equipment depends not on the equipment itself, but on operating conditions of the process fluid/gas flowing through the equipment. The equipment by itself does not generate heat. Due to this reason the temperature class is marked as TX. The maximum permitted ambient and process temperature limits can be found in the operating instructions.
At start up especially for gas applications, ensure that the pressure is graduall y increased through the piping system. A sudden pressure spike situation may result in a fast movement of the float within the VA flowmeter & the float may hit hard against the float stop.
Declaration Declaration Declaration - SEP CRN Declaration DEKRA Certificate/ UL DEKRA Certificate CSA / UL Certificate
MBID 022
3
Page 4
Product Dimensions - Threaded Connections with Indicator Only
*Flow controller bracket not shown. Contact Brooks Instrument for drawing of ow controller with bracket.
4
Page 5
Product Dimensions - Threaded Connections w/Transmitter or Inductive Alarm
*Flow controller bracket not shown. Contact Brooks Instrument for drawing of ow controller with bracket.
5
Page 6
Product Dimensions - Threaded Connections w/Reed Switch Alarm
*Flow controller bracket not shown. Contact Brooks Instrument for drawing of ow controller with bracket.
6
Page 7
Product Specications - Transmitter
Mechanical
Transmitter
Inductive Switch
Alarm
Reed Switch Alarm
ATEX
IECEX
UL
NEPSI
Explosion safety "Intrinsic Safety (ia)"
ATEX
IECEX
NEPSI
Explosion safety "Non-sparking (nA)"
IECEX
Russia Custom Union Excessive Pressure
Russia Custom Union Explosion safety
II 2 G Ex ia IIC T6 II 2 D Ex iaD 21 IP66/IP67 T70°C, II 2 D Ex tD A21 IP66/IP67 T70°C EN 60079-0:2006, EN 60079-11:2007 EN 61241-0:2006, EN 61241-11:2006
Ex d IIC T6 Gb GB3836.1-2010 GB3836.2-2010
Ex ia IIC T6 IEC 60079-0:2004 IEC 60079-11:1999
Class I, II, III, Div.1, Groups A, thru G, T6 Class I, Zone 1 AEx ia IIC T6, Ex ia IIC T6
Ex ia IIC T6 Gb Ex iaD 21 T70°C GB3836.1/4-2010, GB 12476.4-2010
Ex nA II T6
Class I, Div.2, Grps A, B, C, and D; Class II Grps F and G, T6 Class I, Zone 2 AEx nA II T6, Ex nA II T6
Custom Union including Russia "On safety of the equipment for work in explosive environments" ТR СU 012/2011 (TR CU Ex)
Custom Union including Russia “On safety of the equipment operating under excessive pressure” TR CU 032/2013
Meter Options
EX d IIC T6 IEC 60079-0:2004 IEC 60079-1:2003
Special conditions for safe use:
For information regarding the dimension of the flameproof joints the manufacturer shall be contacted.
Class I, Div.1, Groups A, B, C, and D,T6 Class II, Div.1, Groups E, F, and G Class I, Zone 1 AEx d IIC T6, Ex d IIC T6
II 2 G Ex d IIC T6 II 2 D Ex tD A 21 IP66 T 85°C EN 60079-0:2006, EN 60079-1:2004, EN 61241-0:2006, EN 61241:2004
Special conditions for safe use:
For information regarding the dimension of the flameproof joints the manufacturer shall be contacted.
Explosion safety "Flame Proof"
Table x-xx Product Approvals - 3750 With Transmitter
Standards/Directives/MarkingApprovalsMark
KEMA 01ATEX2174
IECEx KEM 06.0049
UL File E73889
GYJ11.1638X
KEMA 01ATEX1033
IECEx KEM 06.0037
1292059
GYJ11.1637
IECEx KEM 06.0037
1292059
TC NRU Д-U.AУ04.B.05988
RU C-HU.ГБ08.B.00741
Declaration/Certificate
Table 7 Product Approvals - MT3750C with Transmitter
Description - Transmitter The transmitter provides accurate magnet angle detection and conversion to a 4 - 20 mA industry standard output signal,
based on the position of a oat assembly in the owmeter. This
rugged, compact, microprocessor-driven device is capable of
providing accurate ow information to your external support
systems. The patented magnetic sensor with automatic gain control enables an extremely high dynamic capture range with-
out sacricing accuracy. (Reference Transmitter Wiring Diagram on page 9)
7
Page 8
Product Specications - Reed Switch Alarm/Limit Switches
Table x-xx Product Approvals - 3750 With Reed Switch Alarm
Description - Reed Switch Alarm Two reed switches are installed in the alarm housing to provide
signaling or switching functions when a preset ow value has
been reached. The reed switches provide high, low or dual setpoints and latched output over the full range. The switches
are normally adjusted to the desired ow range in the factory. Modications to the switch settings can be made in the eld.
Minimum setting distance between two switches is approximately
40% of the scale. (Reference Reed Switch Wiring Diagram on page 9)
Data Reed Switch Maximum Voltage* 175 Vdc, 124 Vac Maximum Current* 250 mA Maximum Contact Rating* 3 Watts
(*Maximum Switch Specications)
Electrical Classication
Non Incendive: Maximum Voltage 30 Vdc Maximum Current 100 mA Maximum Contact Rating 3 Watts
Table 8 Product Approvals - MT3750C With Reed Switch Alarm
Meter Options
ApprovalsMark
Explosion safety "Intrinsic Safety (ia)"
Explosion safety "Non-incendive"
Explosion safety "Intrinsic Safety (ia)"
Mechanical
Transmitter
Standards/Directives/Marking Declaration/Certificate
Inductive Switch
Alarm
Reed Switch Alarm
Class I, Div 1, Groups A, B, C and D; Class II, Groups E, F and G; Class III; Encl Type 4X IS Entity Parameters: Vmax=30Vdc, Imax=100mA, Ci=0, Li=0
Class I, Div 2, Groups A, B, C and D; Class II, Groups E, F and G; Class III; Encl Type 4X
Reed Switch Alarms are classified as “Simple Apparatus” when used in Intrinsically Safe circuits. They comply with the requirements of EN60079-11 clause 5.7 – Simple apparatus.
Ambient Temperature ratings: -20° C ≤ Tamb ≤ 65° C Input parameters: Vmax = 30V, Imax = 100mA, Ci = 0μF, Li = 0μH
Special conditions for safe use:
• The product should be installed by suitably trained personnel, in accordance with the applicable code of practice.
• As the product has no source of internal heating, the temperature classification is dependent on the ambient air temperature.
• Since part of flowmeter enclosure is made of painted aluminum, if it is mounted in group II, category 1 area, it must be installed such, that, ignition sources due to propagating brush discharge spar ks are excluded
1788748
1788748
8
Page 9
Product Specications - Reed Switch Alarm/Limit Switches
Reed Switch Wiring Diagram
Transmitter Wiring Diagram
9
Page 10
Product Specications - Limit Switches/Inductive Alarm Switch
Table x-xx Product Approvals - 3750 With Inductive Alarm
Limit Switches - Inductive Alarm Switch One or two electronic limit switches type SJ2-N can be installed in the indicator housing to allow initiation of signaling or
switching functions on a preset ow value being reached. The
SJ2-N limit switch operates as a slot initiator that is inductively
actuated by a cam mounted to the pointer. Any ow value can
be used for setting the limit value by sliding the switch along the slot in the mounting plate for the initiators. Minimum setting distance between two limit switches is approximately 50% of the scale range.
Power supply 8 Vdc (Max. 15.5 Vdc) Current consumption active area clear: > 3 mA
Current consumption active area obscured: < 1 mA Self inductance 29 µH Self capacitance 20 nF
Max Temp 158°F (70°C)
The ow valve can be used for setting the limit value by sliding
the switch along the slot in the mounting plate for the initiators. Minimum setting distance between two limit switches is approximately 50% of the scale range.
Table 9 Product Approvals - MT3750C With Inductive Alarm
Meter Options
Approvals
Mechanical
Explosion safety "Intrinsic Safety (ia)"
Explosion safety "Non-sparking (nA)"
Russia Custom Union Excessive Pressure
Russia Custom Union Explosion safety
ATEX
IECEX
NEPSI
NEPSI
Transmitter
Standards/Directives/MarkingMark Declaration/Certificate
Inductive Switch
Alarm
Reed Switch Alarm
II 2 G Ex ia IIC T6 II 2 D Ex ia D 21 IP65 T75°C EN 60079-0:2006, EN 60079-11:2007 EN 61241-0:2006, EN 61241-11:2006
Ex ia IIC T6 Gb Ex ia IIIC T 75°C Db IP65 IEC 60079-0:2007-10 , IEC 60079-11:2006 , IEC 61241-11:2005
Class I, II, III, Div.1, Groups A thru G, T6 Class I, Zone 0, Zone 1 AEx ia IIC, T6 Ex ia IIC T6
Ex ia IIC T6 Gb GB3836.1-2010 GB3836.4-2010
Class I, II, III, Div. 2, Groups A thru G, T6 Class I, Zone 2 AEx nA II, T6 Ex nA II T6
Ex nA IIC T6 Gc GB3836.1:2010; GB3836.8:2003
Custom Union including Russia “On safety of the equipment operating under excessive pressure” TR CU 032/2013
Custom Union including Russia "On safety of the equipment for work in explosive environments" ТR СU 012/2011 (TR CU Ex)
KEMA 02ATEX1126
IECEx KEM 09.0046
1379260
GYJ11.1639
1379260
GYJ13.1315
TC N RU Д­U.AУ04.B.05988
RU C-HU.ГБ08.B.00741
10
Page 11
Model Code
Code Description Code Option Option Description
I. Base Model Number 3750C 55 mm, Armored Purge Flowmeter
II. Material Specication 1 316L Stn. Stl. & CRN Certication
4 316L Stn. Stl., CRN Certication & Section IX Welding 5 316L Stn. Stl., CRN Certication & Certied Material to EN 2.2/Section IX Welding 6 316L Stn. Stl., CRN Certication & Certied Material to EN 3.1/Section IX Welding
C 316L Stn. Stl., Certied material to EN 3.1 D 316L Stn. Stl. with Section IX Welding E 316L Stn. Stl., Certied Material to EN 2.2/Section IX Welding F 316L Stn. Stl., Certied Material to EN 3.1/Section IX Welding G Monel K500 H Monel K500 Certied Material to EN 3.1
III. Meter Size 316L Tube Monel K 500 Tube
2** Size 2 - 316L Stn. Stl. Float Size 2 - Monel K 500 Float 3** Size 3 - 316L Stn. Stl. Float Size 3 - Monel K 500 Float 4** Size 4 - 316L Stn. Stl. Float Size 4 - Monel K 500 Float 5** Size 5 - 316L Stn. Stl. Float Size 5 - Monel K 500 Float 6** Size 6 - 316L Stn. Stl. Float Size 6 - Monel K 500 Float
IV. Construction/Seals Construction Seals A** Standard Design Viton O-rings B Standard Design Teon O-rings (No Valve Only) C Standard Design Buna O-rings D** Standard Design Kalrez O-rings (With/Without Valve) E Standard Design EPM O-rings F Standard Design Teon in Meter and Kalrez in Valve G All Welded/High Pressure No Elastomer - No Valve Cavity
V. Connection Size and Type 1** 1/4” NPT (F) - Integral
VI. Connection Orientation 1** Horizontal Inlet and Outlet (Threaded Connections Only)
VII. Valve Conguration A** No Valve (Standard Fitting with Plug)
VIII. Accuracy/Inscription/Fluid Accuracy Inscription Fluid
B** 4 VDI / 5% FS % Scale Liquid
E** 4 VDI / 5% FS Direct Reading Gas F 4 VDI / 5% FS % Scale Liquid - High Viscosity G 4 VDI / 5% FS Direct Reading Liquid - High Viscosity
K 2.5 VDI / 3% FS % Scale Gas L 2.5 VDI / 3% FS Direct Reading Gas M 2.5 VDI / 3% FS % Scale Liquid - High Viscosity
** Select meters ship in 5 days. Max order quantity = 5 meters. Consult factory on orders of more than 5 meters.
2 316L Stn. Stl., CRN Certication & Certied Material to EN 2.2 3 316 Stn. Stl., CRN Certication & Certied Material to EN 3.1
A** 316L Stn. Stl.
B 316L Stn. Stl., Certied Material to EN 2.2
0 Size 0 - Titanium Float Size 0 - Titanium Float
1** Size 1 - 316L Stn. Stl. Float Size 1 - Monel K 500 Float
2 1/4” Tube Compression - With Adapter 3 6 mm Tube Compression - With Adapter 4 1/4” Rc (F) - With Adapter 5 1/2” NPT (F) With Adapter 6 3/4” NPT (F) - With Adapter
B** Low Flow Valve on Inlet - Typical for Sizes 0, 1, 2 C** Medium Flow Valve on Inlet - Typical for Sizes 3 & 4 D** High Flow Valve on Inlet - Typical for Sizes 5 & 6
E No Valve Cavity - All Welded / High Pressure Only K NRS Valve - Size 3 on Inlet - Typical for Sizes 0 & 1
L NRS Valve - Size 4 on Inlet - Typical for Size 2 M NRS Valve - Size 5 on Inlet - Typical for Size 3 N NRS Valve - Size 6 on Inlet - Typical for Sizes 4 & 5 P NRS Valve - Size 7 on Inlet - Typical for Size 6
T Mounted to 316L SS 8802 Flow Controller with Viton Diaphragm
U Mounted to 316L SS 8805 Flow Controller with Teon Diaphragm
V Mounted to 316L SS 8902 Flow Controller with Viton Diaphragm W Mounted to 316L SS 8905 Flow Controller with Teon Diaphragm 1 Mounted to 316L SS 8802 Flow Controller with Teon Diaphragm 3 Mounted to 316L SS 8902 Flow Controller with Teon Diaphragm
9 N/A No Scale N/A A N/A Blank Scale N/A
C** 4 VDI / 5% FS Direct Reading Liquid D** 4 VDI / 5% FS % Scale Gas
H 2.5 VDI / 3% FS % Scale Liquid
J 2.5 VDI / 3% FS Direct Reading Liquid
N 2.5 VDI / 3% FS Direct Reading Liquid - High Viscosity
(Model Code continued on next page)
11
Page 12
Model Code (continued)
Code Description Code Option Option Description
IX. Electrical Output A** None B Reed Switch Alarm, Meter Mounted E Single Inductive Alarm with M20 x 1.5 Electrical Connection F Single Inductive Alarm with 1/2” NPT (F) Electrical Connection G Double Inductive Alarm with M20 x 1.5 Electrical Connection H Double Inductive Alarm with 1/2” NPT (F) Electrical Connection J Mat Transmitter with M20 x 1.5 Electrical Connection K Mat Transmitter with 1/2” NPT (F) Electrical Connection
X. Alarm Relay/ A** None Transmitter Power Supply B Power Supply 24 Vdc with IS Barrier C Power Supply 120 Vac with IS Barrier D Power Supply 240 Vac with IS Barrier E 24 Vdc 1 Channel F 24 Vdc 2 Channel G 120 Vac 1 Channel H 120 Vac 2 Channel J 240 Vac 1 Channel K 240 Vac 2 Channel
XI. Certications/Approvals A** None C Zone 1, Intrinsically Safe CENELEC - ATEX D Zone 1, Flame-proof CENELEC - ATEX E Division 2/Zone 2, Non-incendive CSA - USA and Canada (Transmitter 1/2” NPT & Alarms) F Division 1/Zone 1, Intrinsically Safe CSA - USA and Canada (Transmitter 1/2” NPT & Alarms) G Division 1/Zone 1, Explosion-proof/Flame-proof UL Listed - USA and Canada H Zone 1 Intrinsically Safe NEPSI (China) (1/2” NPT and M20 Elec. Conn.) J Zone 2 Non-sparking NEPSI (China) (1/2” NPT and M20 Elec. Conn.) - Alarm Only K Zone 1 Flame-proof NEPSI - Transmitter Only (China) (M20 Elec. Conn. Only) L Zone 1 Intrinsically Safe IECEx (World) (1/2” NPT and M20 Elec. Conn.) M Zone 2 Non-sparking IECEx (World) - Transmitter Only (1/2” NPT and M20 Elec. Conn.) N Zone 1 Flame-proof IECEx (World) - Transmitter Only (M20 Elec. Conn.) P TR CU Ex Zone 2, Non-incendive/non-sparking (Customs Union including Russia) - Transmitter 1/2” NPT & Alarm R TR CU Ex Zone 1, Flame-proof XP - IIC (Customs Union including Russia) S TR CU Indicator only (Customs Union including Russia) T Zone 1 Flame-proof - KOSHA (Korea) U Zone 1/Zone 2 Non-Electrical ATEX
XII. Material Inspection A** None 1 NACE MR0175 MR0103 - 2.1 Certicate only (316L SS Construction Only) 2 Liquid Dye Penetrant Test Report - 3.1 (Welds Only) - (316L SS Construction Only) 3 Certied According to NACE MR0175 MR0103& Liquid Penetrant 4 International Calibration Certicate Includes Scale Check 5 ICC & NACE MR0175 MR0103 6 Positive Material Identication Report - 3.1 7 PMI & LDP 8 ICC & PMI 9 ICC, PMI & LDP B LDP, ICC C LDP, NACE MR0175 MR0103 D LDP, NACE MR0175 MR0103, PMI E LDP, NACE MR0175 MR0103, PMI, ICC F ICC, PMI, NACE H LDP, ICC, NACE
XIII. Accessory A** None B Flush Panel Mounting (Indicator and Threaded Connections Only) C No Brooks Identication (Indicator Only) D Degrease for Oxygen Service E Commercial Clean S Flush Panel Mounting & Degrease for Oxygen Service (Same as Option B) T Flush Panel Mounting & Special Cleaning (Same as Option B)
XIV. Accessory Group 2 0** None B Bracket, FCA, Standard C Bracket, FCA, Stainless Steel D Dual Scale E Dual Scale and Standard Bracket F Dual Scale and SS Bracket
Sample Standard Model Code
I II III IV V VI VII VIII IX X XI XII XIII XIV 3750C A 2 A 1 1 A B A A A A A 0
** Select meters ship in 5 days. Max order quantity = 5 meters. Consult factory on orders of more than 5 meters.
12
Page 13
Brooks Service and Support
Brooks is committed to assuring all of our customers receive the ideal ow solution for their application, along with outstanding ser­vice and support to back it up. We operate rst class repair facilities located around the world to provide rapid response and support. Each location utilizes primary standard calibration equipment to ensure accuracy and reliability for repairs and recalibration and is certied by our local Weights and Measures Authorities and traceable to the relevant International Standards.
Visit www.BrooksInstrument.com to locate the service location nearest to you.
START-UP SERVICE AND IN-SITU CALIBRATION
Brooks Instrument can provide start-up service prior to operation when required. For some process applications, where ISO-9001
Quality Certication is important, it is mandatory to verify and/or (re)calibrate the products periodically. In many cases this service
can be provided under in-situ conditions, and the results will be traceable to the relevant international quality standards.
SEMINARS AND TRAINING
Brooks Instrument can provide seminars and dedicated training to engineers, end users, and maintenance persons.
Please contact your nearest sales representative for more details.
Due to Brooks Instrument’s commitment to continuous improvement of our products, all specications are subject to change without notice.
TRADEMARKS
Brooks, Ar-Mite & NRS ....................................................Brooks Instrument, LLC
All other trademarks are the property of their respective owners.
13
Loading...