Broan P12D User Manual

INTERNAL BLOWER
!
For use with compatible Best by Broan Outdoor Range Hoods.
MODEL P12D
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN­JURY T O PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and stan­dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori­ties.
5. Suitable for use in damp locations only when installed in a GFCI protected branch circuit.
6. When cutting or drilling into wall or ceiling, do not damage elec­trical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Do not use this range hood with any additional solid-state speed control device.
9. To reduce the risk of fire, use only steel ductwork.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT OF A RANGE T OP GREASE FIRE,OBSERVE THE FOL­LOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know how
to operate it.
B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard­ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. This blower has a thermal overload which will automatically shut off the motor if it becomes overheated.The motor will restart when it cools down.If the motor continues to shut off and restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood should be a minimum of 30” and a maximum of 36” above the cooking surface.
5. Please read specification label on product for further information and requirements.
6. To reduce the risk of fire and to properly exhaust air on a ducted installation, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or ga­rage.
7. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
8. The P12D Blower must be installed with WPD28I Series Range Hoods only. Other Range Hoods cannot be substituted. (Range Hood sold separately.)
Save this manual for Electrical Inspector and Homeowner to use.
INSTALLER:
BEST BY BROAN OUTDOOR
MODEL P12D
Page 2
RANGE HOOD SYSTEM
MODEL 441
(10” Rd. Wall Cap)
MODEL 418
(10” Rd.
Adjustable Elbow)
(10” Rd. Duct - 2 ft. sections)
(10” Rd. Vertical
In-Line Damper)
MODEL 410
MODEL 437
(High Capacity
Roof Cap)
MODEL 421
BLOWER INSTALLATION
Installation into Best by Broan Outdoor Range Hoods.
VERTICAL DISCHARGE
BOTTOM
SLOT
BLOWER TAB
THREADED
STUD
BARREL NUT
INSIDE VIEW
OF HOOD
BLOWER
POWER
CORD
TRANSITION
SV03428
(supplied with hood)
MODEL P12D
BLOWER
(Interior Blower)
AEWPD SERIES
SOFFIT CHIMNEY
(Required only for
soffit-less
installations)
OUTDOOR
SERIES
HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
(WPD281
shown)
ABWPD SERIES
BACKSPLASH
(Stainless Steel wall
covering with shelves.
Optional)
1. Assemble barrel nut (packed loose with blower) approxi­mately 1/2 way onto threaded stud on top inside of hood.
2. Lift blower to top inside of hood as shown. Slide blower back to engage blower tab with slot in hood top and slot in blower with barrel nut.
3. Tighten barrel nut to secure blower to hood. Use a long, flat­blade screwdriver.
4. Plug blower power cord into receptacle inside of hood.
MODEL P12D
Page 3
SERVICE PARTS
Model P12D Dual-Wheel Blower
KEY PART
NO. NUMBER DESCRIPTION QTY.
1 99020122 Blower Wheel, Clockwise 1 2 99170293 Screw, #8-18 x 3/8 12 3 97016751 Barrel Nut 1 4 97016748 Scroll, Left 1 5 97016750 Motor Mount 1 6 98010222 Scroll Brace 2 7 99080572 Motor 1 8 97016746 Scroll, Right 1 9 99020121 Blower Wheel, Counterclockwise 1
10 99260569 Nut, ¼-20 Flanged Hex 4
MODEL P12D
Page 4
WARRANTY
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instruc­tions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
BEST BY BROAN, P.O. Box 140, Hartford, Wisconsin 53027