Broan Nutone RDM1 Installation Manual

READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Register your product online at: www.broan.com/register or www.nutone.com/register.
RDM1
Radiation Damper
INSTALLATION GUIDE
Easy installation
© 2016 Broan-NuTone LLC
Page 2
Usage
For use with 1, 2 or 3-Hour-Rated Floor-Ceiling and Roof-Ceiling Designs.
Flat Ceiling / Horizontal Mount Only.
For use with the following ventilation fan models: Broan A000HF, A000HFC, A000HL, A110, A110C, A110F, A110FC, A110HF, A80, A80C, A80F, A80FC,
A80HD, A80HDF, AE110, AE110C, AE110F, AE110FC, AE110L, AE50, AE50F, AE80, AE80B, AE80BF, AE80BL, AE80BLF, AE80F, AE80L, AE80LF, AE80S, AE80SL, AE110S, AE110SL, A000HFS
NuTone AEN110, AEN110C, AEN110F, AEN110L, AEN50, AEN50F, AEN80, AEN80B, AEN80BF, AEN80BL, AEN80BLF, AEN80F, AEN80L, AEN80LF, AN000HF, AN000HFC, AN000HL, AN110, AN110C, AN110F, AN110FC, AN110HF, AN80C, AN80FC, AN80HDF
RDM1 Installation Guide
SEE DETAILS ON
UL CLASSIFICATION
MARKING ON PRODUCT
Remove Blower & Wiring Panel
The following steps are best performed on a work surface before fan installation. Protect counter tops by placing corrugated sheet under the fan.
1. Remove blower and all packing material from fan housing.
Install Duct Connector
TABS
3. Install duct connector supplied with fan. a. Push duct connector through opening from inside of
housing.
b. Engage tabs and secure with #8-18 hex head screw from
parts bag.
2. Remove wiring panel from fan housing.
Page 3
Attach Radiation Damper Extension to Fan Housing
A
B
D
C
E
4. Attach RADIATION DAMPER EXTENSION (A) to the fan
housing.
For lighted units only: Make sure WIRE HARNESS (B) is
positioned above 7/8” diameter ELECTRICAL ACCESS HOLES (C).
5. Use (4) #8 x 3/8” SHEET METAL SCREWS (D) and 4 SHEET METAL NUTS (E) supplied in radiation damper parts bag.
RDM1 Installation Guide
c. Lift fan housing up into position in ceiling support
structure.
d. MAKE SURE BOTTOM EDGE OF RADIATION
DAMPER IS FLUSH WITH INTERIOR SIDE OF FINISHED CEILING.
e. Extend support bars and secure to ceiling structure
with #8 (M4) sheet metal screws or ¼” diameter bolts with nuts.
J
Install Fan Housing
G
F
H
6. If fan will be mounted between ceiling structure, purchase Hanger
Bar Kit MHB4 from your local Broan-NuTone dealer or distributor.
a. Fasten (2) MOUNTING CHANNELS (F) to the fan
housing or radiation damper with supplied #8 HEX HEAD SCREWS (G).
b. Install (2) SUPPORT BARS (H) per side.
7. If the fan will be mounted directly to the ceiling support structure:
a. MAKE SURE BOTTOM EDGE OF RADIATION
DAMPER IS FLUSH WITH INTERIOR SIDE OF FINISHED CEILING.
b. Additional BLOCKING (J) may be necessary to
securely fasten fan housing to ceiling support structure.
Page 4
RDM1 Installation Guide
Attach 4-inch Round Metal Duct
8. Attach 4-inch round metal duct to the duct connector and discharge air to an outside location. Seal all joints with duct tape.
9. Make sure damper flap opens and closes freely without binding.
Connect Wiring
10. Refer to instructions supplied with the fan for various electrical wiring options.
11. Install electrical box cover removed in Step 2. Secure with one #8-18 hex head screw provided in fan parts bag.
12. Lighted fan models: Connect WIRE HARNESS (B) from radiation damper extension to the CONNECTOR (K) on the wiring box.
Non-lighted fan models: WIRE HARNESS (B) from radiation
damper extension is not used and can be removed. Cut wire tie and discard the harness.
Install Blower into Fan Housing
K
13. Push blower straight up in fan housing and snap into position.
14. Secure blower with (2) #8-18 hex head screws from the fan parts bag.
15. Plug blower motor into receptacle located on wiring panel.
Attach Radiation Damper
A
M
16. Align RADIATION DAMPER (L) holes with holes in the fan EXTENSION (A).
17. Push radiation damper up into the fan extension. Make sure flange is installed as shown. Label inside damper shows correct installation position.
18. Fasten radiation damper to the fan extension with (4) #8 X 3/8” SHEET METAL SCREWS (M) from the radiation damper parts bag.
L