MODEL HLB3
IN-LINE BLOWER
For use with Broan Elite and NuTone Premier Hoods.
READ AND SAVE THESE INSTRUCTIONS
Page 1
!
FOR DOMESTIC COOKING ONLY
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
C. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels violent steam explosion will result.
!
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
• “TYPICAL INST ALLA TION”
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (straight-through blower discharge)
- Wiring
• “MOUNTING OPTIONS”
• “WIRING OPTIONS”
- Wiring Plate Position
• “DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• “USE AND CARE”
• “SERVICE PARTS”
• “WARRANTY”
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
!
Page 2
TYPICAL INSTALLATION
MOUNTING
ADDITIONAL
1½” FRAMING
Blower
factory-
shipped
in straight
through
discharge
position.
Factory-shipped unit installed in new construction.
MOUNTING
10” ROUND DUCT
CEILING JOIST
(16” centers
shown)
(New Frame Construction)
10” ROUND DUCT
8” TO 10” ROUND
TRANSITION
10” ROUND
CEILING JOIST
Mounting brackets factory-
shipped in position for
½” ceiling material.
MOUNTING SCREW
(Existing Frame Construction)
8” TO 10” ROUND
TRANSITION
(OUTLET)
DUCT
(16” centers
shown)
TYPICAL INSTALLATION
MOUNTING USING HANGER KIT (included)
HANGER
KIT BOLT
& WASHER
EXTENSION
SPRING
HANGER
KIT CHAIN
HANGER KIT
EYE-BOLT
8” TO 10”
ROUND
TRANSITION
10” ROUND
DUCT
(OUTLET)
ACCESS PANEL
Blower factory-shipped in straight-through
discharge position.
DUCTING
(Horizontal blower discharge)
10” ROUND
DUCT (INTAKE)
HANGER
KIT NUT &
WASHER
MOUNTING
BRACKET
GRILLE NUT
(Install into
square holes in
housing)
ACCESS
PANEL SCREW
10” ROUND
DUCT
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing &
upside-down)
2 X 4 FRAMING
(wide side down)
(INTAKE)
Blower factory-shipped in straight-through
discharge position.
IMPORTANT:
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.
Remove shipping tape from damper
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating
the ventilator.
ROOF CAP
ROUND DUCT
ROUND
ELBOW
WALL
CAP
Two ways to connect ductwork to a factory-shipped unit.
Page 3
WIRING
BLACK
TO
BLACK
TOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
WIRING
PLATE
120 VAC
WHITE
TO
WHITE
LINE IN
(from
range
hood)
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
MOUNTING OPTIONS
¼-20 hex nuts secure mounting brackets to housing. Loosen and
re-tighten or remove and replace nuts as necessary for desired
mounting bracket position.
WIRING OPTIONS
WIRING PLATE POSITION
HORIZONTAL POWER
CABLE CONNECTION
Wiring plate mounts to side or top of housing.
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
DUCT
CONNECTOR
DUCT
CONNECTOR
VERTICAL
POWER
CABLE
CONNECTION
1
1
MAX.
12¼"
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
(New construction)
12¼"
Mounting brackets
mounted to outlet sides of
housing.
(Outlet perpendicular to joists.)
(New construction)
9
10
/
8
"
12¼"
Mounting brackets flipped
over and mounted to
outlet sides of housing.
(Outlet parallel to joists.)
(
Existing construction)
12¼"
Mounting brackets flipped
over to give approx. 1”
more clearance.
(Outlet parallel to joists.)
(New construction)
1
/
2"
to
1
/
2"
10
11
1½"
to
2½"
1
2
to
Change
blower &
duct
connector
positions for
right angle
discharge.
1
/
2
"
to
1
/
2
"
BLOWER
Blower and duct connec-
tor in
straight through
discharge position.
BLOWER
Blower and duct connec-
right angle dis-
tor in
charge position.
(Factory shipped)
DUCTING
3
/
4
3
/
4
ROUND
DUCT
(Right angle blower discharge)
ROOF CAP
12¼"
Mounting brackets
mounted to top of sides of
housing.
(Outlet parallel to joists.)
(New or existing construction)
12¼"
Mounting brackets flipped
over and mounted to top
of sides of housing.
(Outlet parallel to joists.)
(New or existing construction)
Typical ductwork connection to a ventilator converted
to right angle discharge.
Page 4
USE AND CARE
Follow wiring instructions packed with range hood, and adhere to
all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
SERVICE PARTS
KEY NO. PART NO. DESCRIPTION
1 97014735 Housing Assembly
97014736 Housing Assembly
2 97014728 Mounting Bracket (2 req.)
3 97014761 Damper Assembly (8” dia.)
4 99390099 Duct Connector (8” dia.)
5 99150415 Screw, 8-18 x ¼ (12 req.)*
6 98005513 Wire Box Cover
7 99400035 Strain Relief Bushing
8 98005512 Wiring Plate
9 99150471 Ground Screw, 10-32 x ½ (2 req.)
10 97014775 Scroll Assembly
11 98009399 Inlet Ring
12 99020273 Blower Wheel
13 99080485 Motor
14 99260558 Lock Nut, 8-32 (4 req.)*
15 99250959 Washer (4 req.)*
16 99100491 Grommet (4 req.)
+ 97016792 Blower Assembly, Complete
(Includes Key Nos. 5 & 10-17)
17 99260477 Nut, ¼-20 (6 req.)*
18 97006039 Wire Harness
19 98009417 Access Panel
20 99420470 Cover Nut (2 req.)
21 99150472 Cover Mounting Screw (2 req.)
22 99150591 Screw, 10-16 x 7/8 (4 req.)*
23 97016791 Hanger Kit
24 S414 Transition 8-10” Round
Order replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
+ Not shown assembled.
T o clean blower assembly: Remove access panel, unplug blower
from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment
or a soft cloth and mild soap or detergent to clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER
MOTOR. Make sure blower assembly is completely dry before
reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
24
8
5
3
5
9
2
23
22
1
5
20
4
22
16
5
6
7
5
18
16
11
12
10
14
15
17
13
BLOWER
ASSEMBLY
19
21
WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year
from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and
service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation
contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied
warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER
THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply
to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or phone number stated below (b) give the model number and part identification and (c)
describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
In the U.S., contact: Broan-NuTone, 926 West State Street, Hartford, WI U.S.A. 53027 (1-800-637-1453)
In Canada, contact: Broan-NuTone Canada, 1140 Tristar Drive Mississauga, Ontario L5T 1H9 (1-888-882-7626)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
99043698B