Broan AERN110RGBL, AER110RGBL Installation Manual

ELBOWS*
ChromaComfortTM Fan/Light Installation READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product can be installed in a wall if mounted 8-ft. or more above the floor.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: In the United States - Broan.com 800-637-1453 or NuTone.com 888-336-6151. In Canada - Broan.ca or NuTone.ca 877-896-1119
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance
- lower or remove grille and vacuum interior of unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).
OPERATION
The Chroma Fan/Light must be operated using only the wall control included. See separate operating instructions. DO NOT operate the Chroma Fan/Light with any other switches or controls.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth® SIG, Inc. and any use of such marks by Broan-NuTone LLC is under license. Other trademark and trade names are those of their respective owners.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules and RSS-210 of Canada. Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC IDs: 2ADLL­RGB001 & 2ADLL-RGB002 IC IDs: 2143B-RGB001 & 2143B-RGB002
This Bluetooth® wireless technology enabled luminaire complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying exposure compliance. This luminaire must not be co-located or operate in conjunction with any other antenna or transmitter.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
COOKING AREA
Do not install above or
inside this area.
NOT FOR USE IN
A COOKING AREA.
IMPORTANT -
o
45
Cooking
Equipment
The ducting from this fan to the outside of the building
45
o
Floor
has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
ROOF CAP* (with built-in damper)
INSULATION (Place around and over fan housing.)
FAN
HOUSING
POWER
CABLE *
Seal gaps
around
housing.
DUCT*
* Purchase separately.
Seal duct joints
with tape.
OR
Keep duct
runs short.
WALL CAP* (with built-in
damper)
OPTION - To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors or website). Follow mounting instructions included with kit.
1
ALL INSTALLATIONS
Remove all packing material, unplug
1
1
and remove blower from fan housing.
Remove wiring panel
2
1
from fan housing.
NEW INSTALLATION
A pair of anges
3
1
may be attached to housing if desired or required.
Snap both flange pieces under rolled-over edge of housing (all four sides).
For Retrot Installation ­Skip to Page 3.
Attach damper/duct connector to
4
1
fan housing.
Push connector through opening from inside of housing.
Engage tabs and secure with screw from parts bag.
Connect 4-in.
6 7
round duct.
TABS
Mount housing to ceiling structure.
5
1
Make sure bottom of housing will be flush with finished ceiling.
For proper location using ½” ceiling material: Bend out housing tabs (on outside of housing) to fit against bottom of joist.
Secure housing through mounting ears with appropriate fasteners. If mounting housing to I-joist, use wood blocking as shown.
Connect wiring.
11
Connect power cable to wiring plate (from parts bag) using UL approved connector. Connect house wiring to fan wiring. Use screw (from parts bag) to secure wiring plate to fan housing. Re-install wiring panel and secure with screw from parts bag.
2
HOUSING TABS
Finish ceiling.
8
1
Then continue with Step 9.
I-JOIST
WOOD BLOCKING
RETROFIT INSTALLATION
Remove old
4
1
fan and prepare ceiling.
Enlarge ceiling opening (if necessary) to 9¾” parallel to joist) by 10½” (perpendicular to joist). (Some models have a cut-out template on side of carton.)
Existing fan housings are typically attached to the structure:
with screws, nails, or staples, which must be removed.
• with hangers or rails which are fastened to joists and must be removed along with housing.
A pry bar may be needed to remove the old housing. Leave ductwork and wiring in place.
Connect wiring.
6
1
Connect power cable that will
supply constant 120VAC to unit. Attach wiring to wiring plate (from parts bag) using UL approved connector. Connect house wiring to fan wiring - black to black, white to white, and green to green or bare wire. Use screw (from parts bag) to secure wiring plate to fan housing. Re-install wiring panel and secure with screw from parts bag.
1
9¾-in.
10½-in.
5
1
JOIST
2
Mount fan to
7
1
ceiling structure.
Mount housing to ceiling structure with appropriate fasteners in locations shown.
Center hole is optional.
*
Fold mounting ears at against housing.
*
Connect 4-in. round duct.
8
1
9
1
Pull existing ducting through housing discharge
opening and tape ducting to duct connector.
Push connector/ducting back through opening.
Engage tabs and secure with screw from parts
bag.
Install blower.
Re-install blower removed in Step1. Secure blower with 2 screws from parts bag. Plug blower into black receptacle.
3
2
ALL INSTALLATIONS
TABS
1
4
Continue with Step 9.
3
Loading...
+ 5 hidden pages