Intrusion Alarm Systems | DS794Z and ZX794Z Series Long Range PIR Detectors
DS794Z and ZX794Z Series Long Range
PIR Detectors
www.boschsecurity.com
u Motion Analyzer II processing
u Motion Monitor
The surface or corner mount, long-range DS794Z and
ZX794Z Series PIR Detectors use Motion Analyzer II
signal processing to reduce false alarms. Several
unique test features, including Motion Monitor,
provide coverage integrity. Field replaceable mirrored
optics and three different coverage patterns provide
installation flexibility.
Functions
Signal Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. It will
not alarm on extreme levels of thermal and
illumination disturbances caused by heaters and air
conditioners, hot and cold drafts, sunlight, lightning,
and moving headlights. Three sensitivity settings are
provided.
Test Features
External visible alarm LED flashes to indicate trouble
condition. Internal Noise Voltage Test Pins provide
precise pattern location and background disturbance
u PIR supervision
u Self test supervision systems
u Field-replaceable optics
evaluation using a standard analog meter. Internal
sounder output for use with Sonalert® sounder (not
supplied).
Motion Monitor
Switch-selectable four and thirty day timers verify that
there is a clear view of the protection area.
PIR Supervision
Provides trouble output in the event that PIR circuitry
fails.
Certifications and approvals
Europe DS794ZE complies with EN50131-1, Grade 2
Region Certification
Europe CE 2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD) [DS794Z]
USA UL DS794Z: ANSR: Intrusion Detection
Units (UL639)
24 m
0 m
0 m
8 m
8 m
80 ft
0 ft
0 ft
25 ft
25 ft
0 ft 80 ft
0 ft
25 ft
0 m
24 m
0 m
8 m
0 ft
5 ft
0 m
61 m
0 ft
200 ft
1.5 m
0 m
1.5 m
5 ft
0 ft
200 ft
0 ft
5 ft
61 m
0 m
1.5 m
0 m
0 m
0
m
37 m
3.8 m
3.8 m
120 ft
0
ft
0 ft
12.5 ft
12.5 ft
0 m
0 m
37 m
0 ft
0
ft
7.5 ft
2.3 m
120 ft
2 | DS794Z and ZX794Z Series Long Range PIR Detectors
Region Certification
UL ZX794Z: ANSR: Intrusion Detection
Units (UL639)
China CCC DS794ZE: 2007031901000035
Installation/configuration notes
Top View
Standard Broad Coverage: 24 m x 16 m (80 ft x 50 ft)
Standby Power
If there is no internal standby battery, connect to DC
power source capable of supplying standby power if
the primary power fails.
Model Standby Power mAh required per hour
DS794Z No standby battery 18 mAh
DS794ZE No standby battery 25 mAh
DS794ZE-FRA No standby battery 18 mAh
ZX794Z Provided by the
0.5 mAh
Zonex bus
Notice
A minimum of four hours of standby power is
required for UL Listed requirements.
Parts included
For your convenience, the OA200 Mirror and OA80
Mirror are included with the detector.
Technical specifications
Enclosure
Side View
Standard Broad Coverage: 24 m x 16 m (80 ft x 50 ft)
Top View
Standard Long Range: 61 m x 3 m (200 ft x 10 ft)
Side View
Standard Long Range: 61 m x 3 m (200 ft x 10 ft)
Top View
Optional Long Range 37 m x 8 m (120 ft x 26 ft)
Dimensions: 14 cm x 21 cm x 14 cm
(5 in. x 7.5 in. x 5 in.)
Material: High impact ABS plastic enclosure
Environmental Considerations
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
Radio
Frequency
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
Interference
(RFI) Immunity:
DS794ZE: Complies with Environmental Class II (EN50130-5)
Mounting
Height: 5 m (15 ft.) maximum
Location: Surface or corner
Power Requirements
Current Draw: 18 mA at 12 VDC
25 mA at 12 VDC (DS794ZE)
Voltage (Input):
6 VDC to 15 VDC
ZX794Z: Power comes from two-wire Zonex Bus.
<0.5 mA nominal, 2 mA in alarm with LEDs
enabled. Do not leave Walk Test LEDs enabled.
Side View
Optional Long Range 37 m x 8 m (120 ft x 26 ft)