Bosch ZX794Z Specsheet

Intrusion Alarm Systems | DS794Z and ZX794Z Series Long Range PIR Detectors
DS794Z and ZX794Z Series Long Range PIR Detectors
www.boschsecurity.com
u Motion Analyzer II processing
u Motion Monitor
The surface or corner mount, long-range DS794Z and ZX794Z Series PIR Detectors use Motion Analyzer II signal processing to reduce false alarms. Several unique test features, including Motion Monitor, provide coverage integrity. Field replaceable mirrored optics and three different coverage patterns provide installation flexibility.
Functions
Signal Processing
Motion Analyzer II uses multiple thresholds and timing windows to analyze timing, amplitude, duration, and polarity of signals to make an alarm decision. It will not alarm on extreme levels of thermal and illumination disturbances caused by heaters and air conditioners, hot and cold drafts, sunlight, lightning, and moving headlights. Three sensitivity settings are provided.
Test Features
External visible alarm LED flashes to indicate trouble condition. Internal Noise Voltage Test Pins provide precise pattern location and background disturbance
u Self test supervision systems
u Field-replaceable optics
evaluation using a standard analog meter. Internal sounder output for use with Sonalert® sounder (not supplied).
Motion Monitor
Switch-selectable four and thirty day timers verify that there is a clear view of the protection area.
PIR Supervision
Provides trouble output in the event that PIR circuitry fails.
Certifications and approvals
Europe DS794ZE complies with EN50131-1, Grade 2
Region Certification
Europe CE 2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive (LVD) [DS794Z]
USA UL DS794Z: ANSR: Intrusion Detection
Units (UL639)
24 m
0 m
0 m
8 m
8 m
80 ft
0 ft
0 ft
25 ft
25 ft
0 ft 80 ft
0 ft
25 ft
0 m
24 m
0 m
8 m
0 ft 5 ft
0 m
61 m
0 ft
200 ft
1.5 m
0 m
1.5 m
5 ft
0 ft
200 ft
0 ft
5 ft
61 m
0 m
1.5 m
0 m
0 m
0
m
37 m
3.8 m
3.8 m
120 ft
0
ft
0 ft
12.5 ft
12.5 ft
0 m
0 m
37 m
0 ft
0
ft
7.5 ft
2.3 m
120 ft
2 | DS794Z and ZX794Z Series Long Range PIR Detectors
Region Certification
UL ZX794Z: ANSR: Intrusion Detection
Units (UL639)
China CCC DS794ZE: 2007031901000035
Installation/configuration notes
Top View Standard Broad Coverage: 24 m x 16 m (80 ft x 50 ft)
Standby Power
If there is no internal standby battery, connect to DC power source capable of supplying standby power if the primary power fails.
Model Standby Power mAh required per hour
DS794Z No standby battery 18 mAh
DS794ZE No standby battery 25 mAh
DS794ZE-FRA No standby battery 18 mAh
ZX794Z Provided by the
0.5 mAh
Zonex bus
Notice
A minimum of four hours of standby power is required for UL Listed requirements.
Parts included
For your convenience, the OA200 Mirror and OA80 Mirror are included with the detector.
Technical specifications
Enclosure
Side View Standard Broad Coverage: 24 m x 16 m (80 ft x 50 ft)
Top View Standard Long Range: 61 m x 3 m (200 ft x 10 ft)
Side View Standard Long Range: 61 m x 3 m (200 ft x 10 ft)
Top View Optional Long Range 37 m x 8 m (120 ft x 26 ft)
Dimensions: 14 cm x 21 cm x 14 cm
(5 in. x 7.5 in. x 5 in.)
Material: High impact ABS plastic enclosure
Environmental Considerations
Operating Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to +49°C (+32°F to +120°F)
Radio Frequency
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m. Interference (RFI) Immunity:
DS794ZE: Complies with Environmental Class II (EN50130-5)
Mounting
Height: 5 m (15 ft.) maximum
Location: Surface or corner
Power Requirements
Current Draw: 18 mA at 12 VDC
25 mA at 12 VDC (DS794ZE)
Voltage (Input):
6 VDC to 15 VDC ZX794Z: Power comes from two-wire Zonex Bus. <0.5 mA nominal, 2 mA in alarm with LEDs enabled. Do not leave Walk Test LEDs enabled.
Side View Optional Long Range 37 m x 8 m (120 ft x 26 ft)