Bosch ZX776Z Specsheet

Intrusion Alarm Systems | ZX776Z PIR Intrusion Detector
ZX776Z PIR Intrusion Detector
www.boschsecurity.com
u Internal POPIT
u Motion Analyzer II processing
u Motion Monitor supervision
The ZX776Z PIR Intrusion Detector uses Motion Analyzer II signal processing to reduce false alarms. The detector’s internally pointable mirrors and three coverage patterns provide installation flexibility. The ZX776Z includes an internal POPIT for addressable alarm and trouble signaling while communicating on the Zonex bus.
Functions
Motion Analyzer II Processing
Motion Analyzer II uses multiple thresholds and timing windows to analyze timing, amplitude, duration, and polarity of signals to make an alarm decision. It tolerates extreme levels of heat and light disturbances caused by heaters, air conditioners, hot and cold drafts, sunlight, lightning, and moving headlights.
Motion Monitor Supervision
Confirms the detector has a clear view of the detection area. The Zonex Bus indicates a trouble condition and the LED pulses if the detector has not alarmed at least once during a selected time period.
Insect and Draft Immunity
The sealed optical chamber provides immunity to drafts and insects.
u PIR supervision
PIR Supervision
PIR operation is checked electronically approximately every 12 hours. If the circuit fails, the LED pulses four times and the trouble output is indicated through the Zonex bus.
Test Pins
Internal noise voltage test pins provide precise pattern location and background disturbance evaluation using a standard analog meter.
Three Sensitivity Settings
• Standard Sensitivity: Recommended setting for maximum false alarm immunity. Tolerates environment extremes on this setting. Not recommended for barrier or long range coverage patterns.
• Intermediate Sensitivity: Recommended setting for any location where an intruder is expected to cover only a small portion of the protected area. Tolerates normal environments on this setting.
• High Sensitivity: Fast response to intruder signals. For use in quiet environments where fluctuations in heat or light are not anticipated.
0 ft
0 m
0 ft
7.5 m
25 ft
25 ft
50 ft
7.5 m
15 m
0 m
0 m
0 ft
0 ft
0 m
3 m
15 m
50 ft
10 ft
0 ft
0 m
0 ft
0 m
10 f t
10 f t
80 f t
25 m
3 m
3 m
0 ft
0 m
0 ft
0 m
5 ft
10 ft
80 ft
3 m
25 m
0 m
0 ft
0 m
0 ft
5 ft
5 ft
120 ft
36 m
1.5 m
1.5 m
0 ft
0 m
0 ft
0 m
3 m
10 ft
120 ft
36 m
2 | ZX776Z PIR Intrusion Detector
Certifications and approvals
Region Certification
USA UL ANSR: Intrusion Detection Units
(UL639)
Installation/configuration notes
Compatibility Considerations
Model Compatible Control Panels
ZX776Z • GV2 and G Series
• 9000 Series
• D9112B1
• D7212B1
Notice
The ZX776Z connects to control panels on a Zonex bus.
Mounting Considerations
Select a location that is most likely to intercept an intruder moving across the coverage pattern. Ensure the mounting surface is solid and vibration free. Avoid hot and cold drafts, direct sunlight, heat sources, windows, air conditioning, and small animals. The ZX776Z does not detect through glass.
Broad: 15 m x 15 m (50 ft x 50 ft)
Top View Barrier (OMB77): 25 m x 5 m (80 ft x 16 ft)
Side View Barrier (OMB77): 25 m x 5 m (80 ft x 16 ft)
Top View Long Range (OMLR77): 36 m x 3 m (120 ft x 10 ft)
Notice
Misaligning the detector in an optional mounting bracket can reduce its range.
Top View Broad: 15 m x 15 m (50 ft x 50 ft)
Side View Long Range (OMLR77): 36 m x 3 m (120 ft x 10 ft)
Technical specifications
Enclosure Design
Dimensions: 14.6 cm x 9.5 cm x 6.4 cm
(5.75 in. x 3.75 in. x 2.5 in.)
Environmental Considerations
Temperature (Operating):
Radio Frequency Interference (RFI) Immunity:
-29°C to +49°C (-20°F to +120°F)
For UL Listed Applications, 0°C to + 49°C (+32°F to +120°F)
No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m.
Mounting
Height (recommended): 2 m to 2.6 m (6.5 ft to 8.5 ft)
Location: Surface or corner mount.
Internal Pointability: Coverage is adjustable ±10°
horizontally, +2° to -18° vertically.
Side View