Bosch RE005EV2 User Manual

Note: The button functions are fixed and cannot be changed as per the diagram below.
Panic Function: The fob can generate a panic on the Solution panel. Holding
down buttons 1 and 2 for a period of 2 seconds will cause a panic alarm.
AWAY Arm/Disarm STAY Arm/Disarm Output 1 Relay Output 2 Relay
Operating Voltage 9 - 15VDC Current Consumption 9mA Standby 43mA Both relays operating Relay Rating SPDT 1Amp Maximum carry @ 12VDC Reverse Polarity protection Yes. Diode Operating Frequency 433.92mhz Receiver Type Superheterodyne AM ASK Bandwidth 250khz Antenna 165mm solid core insulated wire Fob Storage EEPROM Maximum 21 Fobs
Transmitter (Fob)
Operating Voltage 3V Lithium Battery CR2032 Operating Frequency 433.92mhz Bandwidth 260khz Tuning SAW resonator locked Channels 4 Weight 33g including battery Visual Indicator Blue LED
RE005EV2
RF Arming Kit for SolutionTM 16
N2127
Overview The RE005EV2 RF Arming Kit is designed to provide a convenient ON/OFF
Control for the Solution16 alarm panels. Provision is also made for the control of up to two (2) external devices via on board relays.
Features
* Code Hopping RF security ( 4.2 billion combinations ) * Simple installation * Superheterodyne receiver (less interference) * Robust attractive keyfobs * Two onboard programmable relays
+ - CLK
Connect to +12 Connect to GND Connect to CLK
Connection for antenna. 17cm wire or coax to external 434mhz antenna. Coax shield connects to GND
Learn/Delete Switch
SPDT relays x 2
Microprocessor
Led
Connection to relays. 1 Amp maximum @ 12VDC
RE005EV2
Installation and Set up
1. Select a location to install the ABS bulkhead case of the receiver which is non metallic. Metal objects close to the receiver may affect range.
2. Connect wiring to Solution 16 keypad bus.
3. In the installer programming of the Solution 16 set; Location 666 = Option 1 enabled Location 665 = Option 8 enabled
if horn speaker beeps are required.
4. The supplied fobs are already learned to the RE005EV2 with both relays set for momentary operation. If however a different relay set up is required then the fobs will need to be deleted and learned again as below.
TO DELETE FO BS - Press and hold the Learn/Delete switch. Note that the LED will light and then extinguish after 4 seconds. The EEPROM memory is now erased. Individual fob deletion is not possible.
TO LEARN FOBS - Press the Learn/Delete switch once. Note that the LED will flash rapidly. Now press the button on the FIRST fob to be learned corresponding to the relay functions required ( see below). The LED will come on solid whilst receiving the transmission and then flash once to confirm learning. Repeat for additional fobs ( maximum 21). It is not important which button is pressed on fobs learned after the FIRST as the relay functions are set by the FIRST learned fob.
Relay Programming Button 1 = Both outputs momentary
Button 2 = Output 1 toggling, Output 2 momentary Button 3 = Output 2 toggling, Output 1 momentary Button 4 = Both outputs toggling
5. Press the Learn/Delete button once when finished learning fobs. Note that if no RF activity occurs the RE005EV2 will leave learn mode automatically after 20 seconds.
6. Test Operation.