The lighting flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude to
constitute a risk to persons.
Installation ManualENGLISH
WARNING
The exclamation point, within an equilateral triangle, is
intended to alert the user to the presence of important
operating and maintenance accompanying the appliance.
CAUTION
To reduce the risk of electric shock, do not remove cover
(or back). No user - servicable parts inside. Refer
servicing to qualified service personnel.
Important Safeguards
1. Keep these instructions.
2. Heed all Warnings.
3. Follow all instructions.
4. Do not use the apparatus near water.
5. Clean with a dry cloth only.
6. Do not install near heat sources such as radiators, heat registers,
stoves, or other apparatus that generates heat (including
amplifiers).
EN
Bosch Security Systems | 2003-08 | Version 2
Page 3
LTC 0335 & LTC 0355 | Installation Manual
EN | 2
7. Do not defeat the purpose of a polarized or grounded mains plug.
A polarized plug has dissimilar prongs (one wider than the other)
to ensure correct polarity, while a grounded plug has an
additional 'ground' prong provided for your safety. If the plug
supplied with the apparatus does not fit into your outlet, consult
an electrician for advice.
8. Protect the power-supply cord from being walked on or pinched,
particularly close to plugs, receptacles and the point where it exits
from the apparatus.
9. Only use attachments and accessories (including stands, tripods,
mounting brackets and housings) specified or recommended by
the manufacturer.
10. Unplug the apparatus during lightning storms and when unused
for extended periods.
11. Do not attempt to service this unit yourself as opening or
removing covers may expose you to dangerous voltage or other
hazards. Refer all servicing to qualified service personnel.
12. Servicing is required when the apparatus does not function in the
normal way, has been dropped, if liquid has been spilled on it, or
if it has been exposed to rain or water. Unplug the unit from the
outlet and refer servicing to qualified service personnel.
13. An all-pole mains switch with contact separation of at least 3 mm
in each pole shall be incorporated in the electrical installation of
the building.
WARNING
To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture.
EN
Bosch Security Systems | 2003-08 | Version 2
Page 4
LTC 0335 & LTC 0355 | Installation Manual
EN | 3
FCC INFORMATION
CAUTION
Any changes or modifications to construction of this
device that are not expressly approved by the party
responsible for compliance could void the userfs authority
to operate the equipment.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
•Re-orient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for
help.
Bosch Security Systems | 2003-08 | Version 2
Page 5
LTC 0335 & LTC 0355 | Installation Manual
EN | 4
SPECIFICATIONS
LTC 0335/x0 LTC 0355/x0
Standard resolutionHigh resolution
StandardCCIREIA CCIREIA
Active pixels (H x V)512 x 582 512 x 492752 x 582768 x 494
Imager1/3" interline CCD
Resolution380 TVL 570 TVL
Minimum illumination<0.12 lux<0.09 lux
Signal-to-noise ratio > 50 dB
Video output1 Vpp, 75
SynchronizationInternal or Line-Lock (selectable)
ShutterAuto / Flickerless / Off (selectable)
AutoblackOn / Off (selectable)
AGCOn (0-21 dB)/ Off (0 dB) (selectable)
BLCOn / Off (selectable)
Lens mountC and CS compatible
ALCVideo-iris or DC-iris (auto detect)
Power supplyLTC 03x5/10 & /20: 12 to 28 VAC or 11 to 36 VDC
Power consumption <4 W
Dimensions (HxWxL)58 x 66 x 122 mm (2.28 x 2.6 x 4.8 inch without lens)
Wei g h t 450 g (0.99 lbs) (without lens)
Camera mountTwo 1/4" 20 UNC - isolated (bottom) and non-isolated
Operating temperature-20ºC to +50ºC (-4ºF to +122ºF)
ControlsOn-screen display (OSD) with softkey controls
CCIR: 1/50 - 1/500000 - EIA: 1/60 - 1/600000
LTC 03x5/50 & /60: 100 to 230 VAC
Ω
(top)
Bosch Security Systems | 2003-08 | Version 2
Page 6
LTC 0335 & LTC 0355 | Installation Manual
EN | 5
Type number overview
Low voltage High voltage
CCIR (Eur.) EIA (USA) CCIR (Eur.) EIA (USA)
Standard resolutionLTC 033 5 /10 LT C 033 5 /2 0 LT C 0335/ 5 0 LTC 03 35 / 60
High resolutionLTC 0355/10 LTC 0355/20 LTC 0355/ 50 LTC 0355/60
UNPACKING
Unpack carefully and handle the equipment with care. The
packaging contains:
•Camera
•CCD protection cap
•Spare lens connector (male)
•These Instructions
Note:
If equipment appears to have been damaged during shipment, repack
it in the original packaging and notify the shipping agent or supplier.
CONNECTION
Power
LTC 03x5/10 and /20LTC 03x5/50 and /60.
Bosch Security Systems | 2003-08 | Version 2
Page 7
LTC 0335 & LTC 0355 | Installation Manual
To open the quick-connect, push in on the tabs.
Connections are not polarity sensitive
Use stranded or solid wire AWG16 to AWG22, cut back 10mm (0.4")
of insulation.
EN | 6
Composite Video
LENS MOUNTING
Pin Video iris lensDC iris lens
1Supply (11 V, 50 mA max.)Damp2Not usedDamp+
3Video signal 1 Vpp, 1 k
4Ground Drive-
•Video-iris and DC-iris lenses are recommended for the best
picture performance.
•The camera automatically detects the type of lens used, and
optimizes performance accordingly.
•A spare male lens connector is provided if required.
Ω
Drive+
Bosch Security Systems | 2003-08 | Version 2
Page 8
LTC 0335 & LTC 0355 | Installation Manual
CAUTION
•To avoid damaging the CCD sensor when using a Cmount lens, turn the 'green' back-focus ring counter
clockwise until it stops ('Back focus adjustment')
before mounting the lens.
•Lenses weighing more than 0.5 kg (1.1lbs) must be
separately supported.
Note:
If a short circuit is detected on the lens connector, the on-screen
display (OSD) failure message 'LENS SHORT CIRCUIT' is shown.
The lens circuit is automatically disabled to avoid internal damage.
Remove the lens connector and check the pin connections.
EN | 7
Back focus adjustment
•Camera accepts both C and CS-mount lenses.
1. Unlock the back focus locking
button.
2. Turn the back focus adjustment as
required. (See Note 1).
3. Lock the back focus locking button.
Notes:
1. The camera's unique "Lens Wizard"
allows focusing to optimize picture
sharpness in both bright and low
level lighting. The lens wizard can
be found in the Installer menu.
Bosch Security Systems | 2003-08 | Version 2
Page 9
LTC 0335 & LTC 0355 | Installation Manual
2. When back focusing vari-focus lenses, it must be possible to
obtain a sharp picture in both wide-angle and tele positions, and
for both far and near focus.
3. When back focusing zoom lenses, ensure the object of interest
remains in focus throughout the entire zoom range of the lens.
(See Advanced Set up).
CAUTION
Do not point the camera/lens into direct sunlight. When
viewing an outdoor scene, a video- or DC-iris lens is
recommended.
EN | 8
MOUNTING THE CAMERA
The camera can be mounted from the top or bottom.
Note:
The BOTTOM mounting is
isolated from ground.
ADVANCED SET-UP
The camera will normally give an optimal picture without the need
for further adjustments. However for special circumstances advanced
set up options are available.
Bosch Security Systems | 2003-08 | Version 2
Page 10
LTC 0335 & LTC 0355 | Installation Manual
Hints for menu navigation
How to use the 5 keys
Up key
EN | 9
Menu/select key
Left key
Lock
Down key
• Press the menu/select key to access the menus or to move to the next or
previous menu.
Right key
•Press the menu/select key for approximately 1.5 seconds to open
the Installer menu.
•Use the up or down keys to scroll up or down through a menu.
•Use the left or right keys to move through options or to set
parameters.
•When in a menu, quickly pressing the menu/select key twice
restores the selected item to its factory default.
• To close all menus at once from any menu, select the Exit item and hold
down the menu/select key until the menu display disappears.
Bosch Security Systems | 2003-08 | Version 2
Page 11
LTC 0335 & LTC 0355 | Installation Manual
LENS WIZARD
DETECTED LENS VIDEO
SET BACK FOCUS NOW
SET LVL
EXIT
LENS WIZARD
DETECTED LENS DCIRIS
SET BACK FOCUS NOW
EXIT
Menu Navigation
Press the menu button
EN | 10
MAIN MENU
LEVEL0
SHUT/AGC
BLCOFF
SYNCLINE LOCK
VPHASE0¡
EXIT
Main Menu
Press the menu button
for more than 5sec.
INSTALLER
VERSION00.0010.XX
LENSAUTO
SPEEDFAST
WIZARD
COAX COMMON
DEFAULTS
EXIT
Installer Menu
SHUT/AGC MENU
SHUTTERAES
AGCON
AUTOBLACKON
Shutter/AGC Menu
Lens Wizard Menus
Bosch Security Systems | 2003-08 | Version 2
EXIT
Page 12
LTC 0335 & LTC 0355 | Installation Manual
EN | 11
Main menu
FunctionSelectionDescripti on
LEVEL-15 - 0 - +15Adjusts video level.
SHUT/AGC Select next menu Shutter / Automatic Gain Control menu.
BLC ONON
SYN C LINE LOCK Select 'LINE LOCK' to synchronize with the
V PHASE0-358ºAdjusts the vertical phase offset (when in
EXITExit the menu.
OFF
When 'ON', the level is optimized at the center
of OFF the screen. Parts outside the center
may be under- or over-exposed (this is normal).
power INTERNAL supply frequency. Select
'INTERNAL' for use with internal
synchronization (automatically selected with
DC supply).
'LINE LOCK' mode).
Shutter/AGC menu
FunctionSelectionDescripti on
SHUTTERAES(AES) Auto-shutter sets the optimum shutter
AGC ON/OFFAutomatic gain control
AUTOBL ACKON/OFFAutoblack automatically increases the visibility
EXITExit the menu.
speed FL for manual iris lenses. (FL)
Flickerless mode avoids OF F interference from
light sources (recommended for use with
video-iris or DC-iris lenses only).
of details.
Accessing installer menu
•To access the installer menu, press and hold the menu/select key
for five seconds.
Bosch Security Systems | 2003-08 | Version 2
Page 13
LTC 0335 & LTC 0355 | Installation Manual
EN | 12
Installer menu
FunctionSelectionDescripti on
VERSI ONRead-only firmware release number (for
LENSAU TOAutomatically detect lens type.
SPEEDFA STSelects the response time of DC-iris lenses.
WIZAR DAccess the lens wizard menu.
COAX COMON/OFFIf OFF Bilinx™ communication is disabled
DEFAULTSSelect next menu Return all set-up settings to
EXIT Exit the menu.
service purposes).
A different lens type can be selected.
Some lenses require slow lens control to avoid
overshoots.
factory defaults.
Lens wizard menu
FunctionDescription
SET BACK FOCUS NOW Back focus the lens (see 'Back focus adjustment'). The
SET LVLWhen a Video-iris lens is detected, a level
EXIT Exit the menu.
scene is focused at maximum lens opening to ensure
that the object of interest remains in focus in bright and
low-light conditions.
potentiometer is displayed to obtain the best picture
performance. The lens wizard includes a level detector
meter that must be set to the center using the
potentiometer for best results.
Bosch Security Systems | 2003-08 | Version 2
Page 14
LTC 0335 & LTC 0355 | Installation Manual
EN | 13
Adjustment procedure DC-iris Lens:
1. Unlock the back focus locking button.
2. Access the "Lens Wizard" menu.
3. The "SET BACK FOCUS NOW" option is highlighted in the
menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Adjustment procedure Manual-iris Lens:
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
Adjustment procedure Video-iris Lens:
1. Unlock the back focus locking button.
2. Access the "Lens Wizard" menu.
3. The "SET BACK FOCUS NOW" option is highlighted in the
menu.
4. Turn the back focus adjustment as required.
5. Select the "SET LVL" option in the menu, and the LEVEL bar
appears.
6. Adjust the level potentiometer located on the lens until the
LEVEL bar is in the central position.