Bosch LTC 0335, LTC 0355 User Manual

Page 1
LTC 0335 & LTC 0355
Installation Manual
Digital Monochrome
EN
Cameras
Manuel d’installat ion
Caméra Numérique Noir et
Blanc
Installations anleitung
Digitale Schwarz-Weiß-
DE
Kamera
Manual de instalación
Cámara Digitales de
ES
Blanco y Negro
Installatiehandl eiding
Digitale Zwart/Wit Camera
NL
Manuale d’installazi one
Videocamera Digitale in
IT
Blanco e Nero
Manual de Instruções
Câmara Digital
PT
Monocromática
ZH
Page 2
LTC 0335 & LTC 0355 | Installation Manual
EN | 1
SAFETY PRECAUTIONS
DANGER
The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk to persons.
Installation ManualENGLISH
WARNING
The exclamation point, within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance accompanying the appliance.
CAUTION
To reduce the risk of electric shock, do not remove cover (or back). No user - servicable parts inside. Refer servicing to qualified service personnel.
Important Safeguards
1. Keep these instructions.
2. Heed all Warnings.
3. Follow all instructions.
4. Do not use the apparatus near water.
5. Clean with a dry cloth only.
6. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus that generates heat (including amplifiers).
EN
Bosch Security Systems | 2003-08 | Version 2
Page 3
LTC 0335 & LTC 0355 | Installation Manual
EN | 2
7. Do not defeat the purpose of a polarized or grounded mains plug. A polarized plug has dissimilar prongs (one wider than the other) to ensure correct polarity, while a grounded plug has an additional 'ground' prong provided for your safety. If the plug supplied with the apparatus does not fit into your outlet, consult an electrician for advice.
8. Protect the power-supply cord from being walked on or pinched, particularly close to plugs, receptacles and the point where it exits from the apparatus.
9. Only use attachments and accessories (including stands, tripods, mounting brackets and housings) specified or recommended by the manufacturer.
10. Unplug the apparatus during lightning storms and when unused for extended periods.
11. Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
12. Servicing is required when the apparatus does not function in the normal way, has been dropped, if liquid has been spilled on it, or if it has been exposed to rain or water. Unplug the unit from the outlet and refer servicing to qualified service personnel.
13. An all-pole mains switch with contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
EN
Bosch Security Systems | 2003-08 | Version 2
Page 4
LTC 0335 & LTC 0355 | Installation Manual
EN | 3
FCC INFORMATION
CAUTION
Any changes or modifications to construction of this device that are not expressly approved by the party responsible for compliance could void the userfs authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Bosch Security Systems | 2003-08 | Version 2
Page 5
LTC 0335 & LTC 0355 | Installation Manual
EN | 4
SPECIFICATIONS
LTC 0335/x0 LTC 0355/x0
Standard resolution High resolution Standard CCIR EIA CCIR EIA Active pixels (H x V) 512 x 582 512 x 492 752 x 582 768 x 494 Imager 1/3" interline CCD Resolution 380 TVL 570 TVL Minimum illumination <0.12 lux <0.09 lux Signal-to-noise ratio > 50 dB Video output 1 Vpp, 75 Synchronization Internal or Line-Lock (selectable) Shutter Auto / Flickerless / Off (selectable)
Autoblack On / Off (selectable) AGC On (0-21 dB)/ Off (0 dB) (selectable) BLC On / Off (selectable) Lens mount C and CS compatible ALC Video-iris or DC-iris (auto detect) Power supply LTC 03x5/10 & /20: 12 to 28 VAC or 11 to 36 VDC
Power consumption <4 W Dimensions (HxWxL) 58 x 66 x 122 mm (2.28 x 2.6 x 4.8 inch without lens) Wei g h t 450 g (0.99 lbs) (without lens) Camera mount Two 1/4" 20 UNC - isolated (bottom) and non-isolated
Operating temperature -20ºC to +50ºC (-4ºF to +122ºF) Controls On-screen display (OSD) with softkey controls
CCIR: 1/50 - 1/500000 - EIA: 1/60 - 1/600000
LTC 03x5/50 & /60: 100 to 230 VAC
(top)
Bosch Security Systems | 2003-08 | Version 2
Page 6
LTC 0335 & LTC 0355 | Installation Manual
EN | 5
Type number overview
Low voltage High voltage
CCIR (Eur.) EIA (USA) CCIR (Eur.) EIA (USA) Standard resolution LTC 033 5 /10 LT C 033 5 /2 0 LT C 0335/ 5 0 LTC 03 35 / 60 High resolution LTC 0355/10 LTC 0355/20 LTC 0355/ 50 LTC 0355/60
UNPACKING
Unpack carefully and handle the equipment with care. The packaging contains:
Camera
CCD protection cap
Spare lens connector (male)
These Instructions
Note: If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.
CONNECTION
Power
LTC 03x5/10 and /20 LTC 03x5/50 and /60.
Bosch Security Systems | 2003-08 | Version 2
Page 7
LTC 0335 & LTC 0355 | Installation Manual
To open the quick-connect, push in on the tabs. Connections are not polarity sensitive Use stranded or solid wire AWG16 to AWG22, cut back 10mm (0.4") of insulation.
EN | 6
Composite Video
LENS MOUNTING
Pin Video iris lens DC iris lens 1 Supply (11 V, 50 mA max.) Damp­2 Not used Damp+ 3 Video signal 1 Vpp, 1 k 4 Ground Drive-
Video-iris and DC-iris lenses are recommended for the best picture performance.
The camera automatically detects the type of lens used, and optimizes performance accordingly.
A spare male lens connector is provided if required.
Drive+
Bosch Security Systems | 2003-08 | Version 2
Page 8
LTC 0335 & LTC 0355 | Installation Manual
CAUTION
To avoid damaging the CCD sensor when using a C­mount lens, turn the 'green' back-focus ring counter clockwise until it stops ('Back focus adjustment') before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported.
Note: If a short circuit is detected on the lens connector, the on-screen display (OSD) failure message 'LENS SHORT CIRCUIT' is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections.
EN | 7
Back focus adjustment
Camera accepts both C and CS-mount lenses.
1. Unlock the back focus locking button.
2. Turn the back focus adjustment as required. (See Note 1).
3. Lock the back focus locking button.
Notes:
1. The camera's unique "Lens Wizard" allows focusing to optimize picture sharpness in both bright and low level lighting. The lens wizard can be found in the Installer menu.
Bosch Security Systems | 2003-08 | Version 2
Page 9
LTC 0335 & LTC 0355 | Installation Manual
2. When back focusing vari-focus lenses, it must be possible to obtain a sharp picture in both wide-angle and tele positions, and for both far and near focus.
3. When back focusing zoom lenses, ensure the object of interest remains in focus throughout the entire zoom range of the lens. (See Advanced Set up).
CAUTION
Do not point the camera/lens into direct sunlight. When viewing an outdoor scene, a video- or DC-iris lens is recommended.
EN | 8
MOUNTING THE CAMERA
The camera can be mounted from the top or bottom.
Note: The BOTTOM mounting is isolated from ground.
ADVANCED SET-UP
The camera will normally give an optimal picture without the need for further adjustments. However for special circumstances advanced set up options are available.
Bosch Security Systems | 2003-08 | Version 2
Page 10
LTC 0335 & LTC 0355 | Installation Manual
Hints for menu navigation
How to use the 5 keys
Up key
EN | 9
Menu/select key
Left key
Lock
Down key
• Press the menu/select key to access the menus or to move to the next or
previous menu.
Right key
Press the menu/select key for approximately 1.5 seconds to open the Installer menu.
Use the up or down keys to scroll up or down through a menu.
Use the left or right keys to move through options or to set parameters.
When in a menu, quickly pressing the menu/select key twice restores the selected item to its factory default.
• To close all menus at once from any menu, select the Exit item and hold
down the menu/select key until the menu display disappears.
Bosch Security Systems | 2003-08 | Version 2
Page 11
LTC 0335 & LTC 0355 | Installation Manual
LENS WIZARD
DETECTED LENS VIDEO
SET BACK FOCUS NOW
SET LVL
EXIT
LENS WIZARD
DETECTED LENS DCIRIS
SET BACK FOCUS NOW
EXIT
Menu Navigation
Press the menu button
EN | 10
MAIN MENU
LEVEL 0 SHUT/AGC BLC OFF
SYNC LINE LOCK VPHASE
EXIT
Main Menu
Press the menu button for more than 5sec.
INSTALLER
VERSION 00.0010.XX
LENS AUTO SPEED FAST WIZARD COAX COMM ON
DEFAULTS
EXIT
Installer Menu
SHUT/AGC MENU
SHUTTER AES
AGC ON
AUTOBLACK ON
Shutter/AGC Menu
Lens Wizard Menus
Bosch Security Systems | 2003-08 | Version 2
EXIT
Page 12
LTC 0335 & LTC 0355 | Installation Manual
EN | 11
Main menu
Function Selection Descripti on LEVEL -15 - 0 - +15 Adjusts video level. SHUT/AGC Select next menu Shutter / Automatic Gain Control menu. BLC ON ON
SYN C LINE LOCK Select 'LINE LOCK' to synchronize with the
V PHASE 0-358º Adjusts the vertical phase offset (when in
EXIT Exit the menu.
OFF
When 'ON', the level is optimized at the center of OFF the screen. Parts outside the center may be under- or over-exposed (this is normal).
power INTERNAL supply frequency. Select 'INTERNAL' for use with internal synchronization (automatically selected with DC supply).
'LINE LOCK' mode).
Shutter/AGC menu
Function Selection Descripti on SHUTTER AES (AES) Auto-shutter sets the optimum shutter
AGC ON/OFF Automatic gain control AUTOBL ACK ON/OFF Autoblack automatically increases the visibility
EXIT Exit the menu.
speed FL for manual iris lenses. (FL) Flickerless mode avoids OF F interference from light sources (recommended for use with video-iris or DC-iris lenses only).
of details.
Accessing installer menu
To access the installer menu, press and hold the menu/select key for five seconds.
Bosch Security Systems | 2003-08 | Version 2
Page 13
LTC 0335 & LTC 0355 | Installation Manual
EN | 12
Installer menu
Function Selection Descripti on VERSI ON Read-only firmware release number (for
LENS AU TO Automatically detect lens type.
SPEED FA ST Selects the response time of DC-iris lenses.
WIZAR D Access the lens wizard menu. COAX COM ON/OFF If OFF Bilinx™ communication is disabled DEFAULTS Select next menu Return all set-up settings to
EXIT Exit the menu.
service purposes).
A different lens type can be selected.
Some lenses require slow lens control to avoid overshoots.
factory defaults.
Lens wizard menu
Function Description SET BACK FOCUS NOW Back focus the lens (see 'Back focus adjustment'). The
SET LVL When a Video-iris lens is detected, a level
EXIT Exit the menu.
scene is focused at maximum lens opening to ensure that the object of interest remains in focus in bright and low-light conditions.
potentiometer is displayed to obtain the best picture performance. The lens wizard includes a level detector meter that must be set to the center using the potentiometer for best results.
Bosch Security Systems | 2003-08 | Version 2
Page 14
LTC 0335 & LTC 0355 | Installation Manual
EN | 13
Adjustment procedure DC-iris Lens:
1. Unlock the back focus locking button.
2. Access the "Lens Wizard" menu.
3. The "SET BACK FOCUS NOW" option is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Adjustment procedure Manual-iris Lens:
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
Adjustment procedure Video-iris Lens:
1. Unlock the back focus locking button.
2. Access the "Lens Wizard" menu.
3. The "SET BACK FOCUS NOW" option is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Select the "SET LVL" option in the menu, and the LEVEL bar appears.
6. Adjust the level potentiometer located on the lens until the LEVEL bar is in the central position.
7. Lock the back focus locking button.
8. Exit the menu.
Bosch Security Systems | 2003-08 | Version 2
Page 15
Bosch Sicherheitssysteme GmbH Ludwig-Bölkow-Allee 85521 Ottobrunn Germany www.bosch-sicherheitssysteme.de
3122 165 22651 03-40 © 2003 Bosch Security Systems B.V. Subject to change Printed in Portugal
Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands www.boschsecuritysystems.com
Loading...