Power Tools Division
70745 Leinfelden-Echterdingen
Germany
www.bosch-pt.com
GMS 120 Professional
2 609 140 939 (2012.03) T / 157 XXX
de Originalbetriebsanleitung
en Original instructions
fr Notice originale
es Manual original
pt Manual original
it Istruzioni originali
nl Oorspronkelijke gebruiksaanwijzing
da Original brugsanvisning
sv Bruksanvisning i original
no Original driftsinstruks
fi Alkuperäiset ohjeet
el Рсщфьфхрп пдзгйюн чсЮузт
tr Orijinal işletme talimat
pl Instrukcja oryginalna
cs Původní návod k používání
sk Pôvodný návod na použitie
hu Eredeti használati utasítás
ru Оригинальное руководство по
эксплуатации
uk Ориг³нальна ³нструкц³я з експлуатац³¿
ro Instrucţiuni originale
bg Оригинална инструкция
sr Originalno uputstvo za rad
sl Izvirna navodila
hr Originalne upute za rad
et Algupärane kasutusjuhend
lv Instrukcijas oriģinālvalodā
lt Originali instrukcija
ja オリジナル取扱説明書
正本使用说明书
cn
tw 正本使用說明書
ko 사용 설명서 원본
th หนังสือคูมือการใชงานฉบับตนแบบ
id Petunjuk-Petunjuk untuk
Penggunaan Orisinal
vi
BΩng hõëng dÿn nguy›n bΩn
ar
fa
Page 2
3 |
1
2
10
N
S
3
4
9
8
5
6
GMS 120
Professional
7
GMS 120
2 609 140 939 | (8.3.12)Bosch Power Tools
Page 3
4 |
11
12
13
11
2
GMS
Professional
11
17
14
15
18
18
16
2 609 140 939 | (8.3.12)Bosch Power Tools
Page 4
5 |
Sensor
N
S
A
e
B
12
A
ab cd
B
11
2
Sensor
11
N
S
fgh
N
S
i
j
k
N
S
3x
N
S
B
11
GMS 120
Professional
GMS 120
Professional
B
B
2 609 140 939 | (8.3.12)Bosch Power Tools
Page 5
10 | English
English
Safety Notes
Read and observe all instructions. SAVE
THESE INSTRUCTIONS FOR FUTURE REFERENCE.
f Have the measuring tool repaired only through quali-
fied specialists using original spare parts. This ensures
that the safety of the measuring tool is maintained.
f Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
f For technological reasons, the measuring tool cannot
ensure 100 % certainty. To rule out hazards, safeguard
yourself each time before drilling, sawing or routing in
walls, ceilings or floors by means of other information
sources, such as building plans, pictures from the construction phase, etc. Environmental influences, such as
humidity or closeness to electrical devices, can influence
the accuracy of the measuring tool. Surface quality and
condition of the walls (e.g., moisture, metallic building materials, conductive wallpaper, insulation materials, tiles)
as well as the amount, type, size and position of the objects
can lead to faulty measuring results.
Product Description and
Specifications
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operating instructions.
Intended Use
The measuring tool is intended for the detection of metals
(ferrous and non-ferrous metals, e.g., rebar), joists and “live”
wires/conductors in walls, ceilings and floors.
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1 Illuminated ring
2 Marking hole
3 Display
4 Operating-mode indication
5 On/Off button
6 Display-illumination button
7 Audio signal button
8 Button for detecting “live” conductors/Operating mode
“Power cable”
9 Button for metal detection/Operating mode “Metal”
10 Button for detecting wood and metal beams/Operating
mode “Drywall”
11 Contact pads
12 Sensor area
13 Type plate
14 Battery lid
15 Latch of battery lid
16 Fixture for carrying strap
17 Protective pouch
18 Carrying strap
The accessories illustrated or described are not included as standard delivery.
Page 6
English | 11
Display Elements (see figure A)
a Switched-off audio signal indicator
b Warning-function indicator
c Indication of the object type “Non-metal object”
d Indication of the object type “Non-magnetic metal”
e Indication of the object type “Magnetic metal”
f Indication of the object type “Live conductor”
g Temperature control indicator
h Battery indicator
i Measuring indicator
j Fine scale
k Indication “CENTER”
Technical Data
Digital DetectorGMS 120
Article number
Maximum scanning depth*
– Ferrous metals
– Non-ferrous metals (copper)
– Live conductors 110– 230 V
(voltage applied)**
– Wood
Automatic switch-off after approx.
Operating temperature
Storage temperature
Battery
Operating life time, approx.
Weight according to
EPTA-Procedure 01/2003
Degree of protection
*depending on operating mode, material and size of the objects, as well
as material and condition of the base material
**less scanning depth for wires/conductors that are not “live”
f In terms of accuracy, the measuring result can be inferior in case
of unfavourable surface quality of the base material.
3 601 K81 0..
120 mm
80 mm
50 mm
38 mm
5min
–10°C...+50°C
–20°C...+70°C
1 x 9 V 6LR61
270 g
IP 54 (dust and splash
water protected)
Declaration of Conformity
We declare under our sole responsibility that the product
described under “Technical Data” is in conformity with the following standards or standardization documents:
EN 61010-1:2010-10, EN 61326-1:2006-05,
EN 301489-3:2002-08, EN 301489-1:2008-04,
EN 300330-1:2010-02, EN 300330-2:2010-02 according
to the provisions of the directives 2011/65/EU,
2004/108/EC, 1999/5/EC.
Dr. Egbert Schneider
Senior Vice President
Engineering
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 02.03.2012
Bosch Power Tools2 609 140 939 | (8.3.12)
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
Assembly
Inserting/Replacing the Battery
Alkali-manganese batteries are recommended for the measuring tool.
To open the battery lid 14, press the latch 15 in the direction
of the arrow and fold up the battery lid. Insert the supplied
battery. Pay attention that the polarity is correct, according to
the representation on the inside of the battery lid.
The battery indicator h always indicates the current battery
status:
–Battery fully charged
–Battery has 2/3 of its capacity or less
–Battery has 1/3 of its capacity or less
–Please change battery
f If the measuring tool is not used for a long period of
time, the battery must be removed. The battery can cor-
rode or discharge itself over long periods.
Operation
f Protect the measuring tool against moisture and direct
sun light.
f Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before switching it on.
In case of extreme temperatures or variations in tempera-
5h
ture, the accuracy of the measuring tool and the display indication can be impaired.
f Use or operation of transmitting systems, such as
WLAN, UMTS, radar, transmitter masts or microwaves,
in the close proximity can influence the measuring
function.
Initial Operation
Switching On and Off
f Before switching the measuring tool on, make sure that
the sensor area 12 is not moist. If required, dry the meas-
uring tool using a soft cloth.
f If the measuring tool was subject to an extreme tem-
perature change, allow it to adjust to the ambient temperature before switching on.
To switch on the measuring tool, press the On/Off button 5.
To switch off the measuring tool, press the On/Off button 5
again.
When no button on the measuring tool is pressed for approx.
5 minutes and when no objects are detected, the measuring
tool automatically switches off to save the battery.
Switching the Display Illumination On/Off
The display illumination can be switched on/off with displayillumination button 6.
Switching the Audio Signal On/Off
The audio signal can be switched on/off with the audio signal
button 7. When the audio signal is switched off, indication a
appears on the display.
Page 7
12 | English
Method of Operation (see figures A–B)
The measuring tool checks the base material of sensor area
12 in measurement direction A to the max. detection depth
(see “Technical Data”). Objects are detected that differ from
the material of the wall.
Always move the measuring tool in a straight line over the surface applying slight pressure, without lifting it off or changing
the pressure. During measurement, the contact pads 11 must
always have contact to the surface.
Measuring Procedure
Position the measuring tool on/against the surface being
detected, and move it in direction B. When the measuring tool
comes closer to an object, the amplitude in measuring indicator i increases and ring 1 lights up yellow; when it is moved
away from the object, the amplitude decreases. Measuring
indicator i indicates the maximal amplitude above the centre
of the object; ring 1 lights up red and an audio signal sounds.
For small or deeply embedded objects, ring 1 can continue to
light up yellow, while there is no audio signal.
f Wide objects are not indicated by the illuminated ring
or the audio signal throughout their complete width.
To localise the object more precisely, move the measuring
tool repeatedly (3x) back and forth over the object. The fine
scale j is automatically activated in all operating modes. Fine
scale j indicates a full amplitude when the object is below the
centre of the sensor or when the maximum amplitude of
measuring indicator i is reached. In the operating modes
“Drywall” and “Metal”, the indication “CENTER”k lights up
additionally.
Wider objects in the base material are detected through a
continuous, high amplitude of measuring indicators i and j.
Ring 1 lights up yellow. The duration of the high amplitude
corresponds approximately with the object width.
When very small or deeply embedded objects are being
sought and measuring indicator i reacts only slightly, move
the measuring tool repeatedly over the object in horizontal
and vertical direction. Pay attention to the amplitude of fine
scale j, and when in operating mode “Drywall” and “Metal”,
additionally to the
low for precise detection.
f Before drilling, sawing or routing into a wall, protect
yourself against hazards by using other information
sources. As the measuring results can be influenced
through ambient conditions or the wall material, there may
be a hazard even though the indicator does not indicate an
object in the sensor range (no audio signal or beep and and
the illuminated ring 1 lit green).
“CENTER ” k indication, which will then al-
Operating Modes
The best measuring results are achieved through selection of
the operating modes. The maximal detection depth for metal
objects is achieved in the operating mode “Metal”. The maximal detection depth for “live” conductors is achieved in the
operating mode “Power cable”. The selected operating
mode can be recognized at any time via the green illuminated
operating-mode indication 4.
2 609 140 939 | (8.3.12)Bosch Power Tools
Drywall
The operating mode “Drywall” is suitable for detecting wood
or metal objects in drywalls.
Press button 10 to activate the operating mode “Drywall”.
The operating-mode indication 4 above button 10 lights up
green. As soon as the measuring tool is positioned against the
base material to be detected, ring 1 lights up green and signals operational readiness.
In the operating mode “Drywall” all object types are detected
and indicated:
–Non-metal, e.g. a wood beam
–Magnetic, e.g. reinforcing steel
–Non-magnetic, but metal, e.g. copper pipe
–“Live”, e.g. a “live” conductor
Notes: In the operating mode “Drywall”, other objects, apart
from wood and metal objects and “live” conductors are also
detected, such as plastic tubing filled with water. For such
objects, the indication c for non-metal objects is indicated in
display 3.
Nails and screws in the base material may cause a wooden
beam to be indicated as a metal object on the display.
When display 3 indicates a continuously high amplitude of
measuring indicator i and fine scale j, restart the measuring
procedure again by positioning the measuring tool at a different location on the base material.
When the illuminated ring 1 does not signal operational readiness when positioning the measuring tool on the base material being detected, the measuring tool cannot properly detect the base material.
– Press and hold button 10 until the illuminated ring lights up
green.
– When starting a new measuring procedure afterwards and
positioning the measuring tool onto a different wall or surface, you must briefly press button 10.
– In rare cases, the measuring tool may not be able to detect
the base material because the side with the sensor area 12
and the type plate 13 is soiled or dirty. Clean the measuring tool with a dry, soft cloth and restart the measuring procedure.
Metal
The operating mode “Metal” is suitable for detecting magnetic and non-magnetic objects independent of the wall material.
Press button 9 to activate the operating mode “Metal”. The il-
luminated ring 1 and indication 4 above button 9 light up
green.
When the detected metal object is of magnetic metal (e.g.
iron), the symbol e is indicated on display 3. For non-magnetic metals, the symbol d is indicated. In order to differentiate
between metal types, the measuring tool must be positioned
above the detected metal object (ring 1 is lit red).
Note: For reinforcement steel mesh and steel in the examined
base material, an amplitude is indicated over the complete
surface of measuring indicator i. For reinforcement steel
mesh, it is typical that the symbol e for magnetic metal is indicated on the display directly above the iron rods, whereas between the iron rods, the symbol d for non-magnetic metal will
appear.
Page 8
Power Cable
The operating mode “Power cable” is suitable only for detecting "live" conductors (110– 230 V).
Press button 8 to activate the operating mode “Power cable”.
The illuminated ring 1 and indication 4 above button 8 light up
green.
When a “live” conductor is detected, indication f appears on
the display 3. Move the measuring tool repeatedly over the area to localise the “live” conductor more precisely. After moving over the “live” conductor several times, it can be indicated
very accurately. When the measuring tool is very close to the
conductor, the illuminated ring 1 flashes red and the audio
signal beeps swiftly.
Notes:
– “Live” conductors are indicated in any operating mode.
– “Live” conductors can be detected easier when power con-
sumers (e.g. lamps, machines) are connected to the
sought conductor and switched on.
– Under certain conditions (such as below metal surfaces
or behind surfaces with high water content), “live” conductors cannot be securely detected. The signal
strength of a “live” conductor depends on the position of
the cable. Therefore, apply further measurements in close
proximity or use other information sources to check if a
“live” conductor exists.
– Voltage-free conductors can be detected as metal objects
in the operation mode “Metal”. This does not apply for
stranded conductors (contrary to solid conductors or
cable).
– Static electricity can lead to inaccurate indication of elec-
tric lines, e.g., over a large range. To improve the indication, place your free hand flat on the wall next to the measuring tool, in order to remove the static electricity.
Working Advice
f Measuring values can be impaired through certain am-
bient conditions. These include, e.g., the proximity of
other equipment that produce strong magnetic or electromagnetic fields, moisture, metallic building materials, foil-laminated insulation materials or conductive
wallpaper or tiles. Therefore, please also observe other
information sources (e.g. construction plans) before drilling, sawing or routing into walls, ceilings or floors.
Marking Objects
If required, detected objects can be marked. Perform a measurement as usual. Once you have found the boundaries or the
centre of an object, mark the sought location through the
marking hole 2.
Temperature Control
The measuring tool is equipped with a temperature control indicator, as accurate measurements are only possible as long as
the temperature within the measuring tool remains constant.
When the temperature control indicator g lights up, the measuring tool is not within the operating temperature range or
was subject to large variations in temperature. Switch the
measuring tool off and allow it to adjust to the ambient
temperature before switching it on again.
English | 13
Warning Function
When indicator b lights up on display 3 and indication 4 flashes above button 10, the measurement must be restarted. Remove the measuring tool from the wall and place it on the base
material at a different location.
When indicator b flashes on display 3, send the measuring
tool in the provided protective pouch to an authorised customer services agent.
Recalibration
When measuring indicator i indicates a continuously high amplitude in the operating mode “Metal”, even though there is
no metal object near the measuring tool, the measuring tool
can be manually recalibrated.
– Switch the measuring tool off.
– Remove all objects near the measuring tool that could be
detected, including your wrist watch or rings made of
metal, and hold the measuring tool up.
Pay attention that battery indicator h indicates at least 1/3
capacity:
Hold the measuring tool in such a manner that the type
plate 13 faces toward the ground. Avoid bright light sources or direct sunlight from shining on the area 12 and 13,
without covering off this area.
– Press and hold buttons 5 and 7 until the illuminated ring 1
lights up red. Then release both buttons.
– When the calibration was successful, the measuring tool
will automatically start after a few seconds, and will be
ready for operation again.
Note: If the measuring tool does not automatically start,
repeat the recalibration. If the measuring tool still does not
start, send it in the provided protective pouch to an authorised customer services agent.
Maintenance and Service
Maintenance and Cleaning
f Check the measuring tool each time before use. In case
of visible damage or loose components inside the measuring tool, safe function can no longer be ensured.
Keep the measuring tool clean and dry at all times to ensure
proper and safe working.
Do not immerse the measuring tool in water or other fluids.
Wipe away debris or contamination with a dry, soft cloth. Do
not use cleaning agents or solvents.
In order not to affect the measuring function, decals/stickers or
name plates, especially metal ones, may not be attached in the
sensor area 12 on the front or back side of the measuring tool.
Do not remove the contact pads 11 on the backside of the
measuring tool.
If the measuring tool should fail despite the care taken in
manufacturing and testing procedures, repair should be
carried out by an authorised after-sales service centre for
Bosch power tools. Do not open the measuring tool yourself.
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the type plate of
the measuring tool.
Bosch Power Tools2 609 140 939 | (8.3.12)
Page 9
14 | English
Store and transport the measuring tool only in the supplied
protective pouch.
In case of repairs, send in the measuring tool packed in its
protective pouch 17.
After-sales Service and Customer Assistance
Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can
also be found under:
www.bosch-pt.com
Our customer service representatives can answer your questions concerning possible applications and adjustment of
products and accessories.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: +44 (0844) 736 0109
Fax: +44 (0844) 736 0146
E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: +353 (01) 4 66 67 00
Fax: +353 (01) 4 66 68 88
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: +61 (01300) 307 044
Fax: +61 (01300) 307 045
Inside New Zealand:
Phone: +64 (0800) 543 353
Fax: +64 (0800) 428 570
Outside AU and NZ:
Phone: +61 (03) 9541 5555
www.bosch.com.au
Bosch Power Tools (China) Co., Ltd.
567, Bin Kang Road
Bin Jiang District 310052
Hangzhou, P.R. China
Service Hotline: 400 826 8484
Fax: +86 571 8777 4502
E-Mail: contact.ptcn@cn.bosch.com
www.bosch-pt.com.cn
HK and Macau Special Administrative Regions
Robert Bosch Hong Kong Co. Ltd.
21st Floor, 625 King’s Road
North Point, Hong Kong
Customer Service Hotline: +852 2101 0235
Fax: +852 2590 9762
E-Mail: info@hk.bosch.com
www.bosch-pt.com.hk
Indonesia
PT. Multi Mayaka
Kawasan Industri Pulogadung
Jalan Rawa Gelam III No. 2
Jakarta 13930
Indonesia
Tel.: +62 (21) 46 83 25 22
Fax: +62 (21) 46 82 86 45/ 68 23
E-Mail: sales@multimayaka.co.id
www.bosch-pt.co.id
Philippines
Robert Bosch, Inc.
28th Floor Fort Legend Towers,
3rd Avenue corner 31st Street,
Fort Bonifacio Global City,
1634 Taguig City, Philippines
Tel.: +63 (2) 870 3871
Fax: +63 (2) 870 3870
matheus.contiero@ph.bosch.com
www.bosch-pt.com.ph
Page 10
Bosch Service Center:
9725-27 Kamagong Street
San Antonio Village
Makati City, Philippines
Tel.: +63 (2) 899 9091
Fax: +63 (2) 897 6432
rosalie.dagdagan@ph.bosch.com
Robert Bosch Vietnam Co. Ltd
10/F, 194 Golden Building
473 Dien Bien Phu Street
Ward 25, Binh Thanh District
84 Ho Chi Minh City
Vietnam
Tel.: +84 (8) 6258 3690 ext. 413
Fax: +84 (8) 6258 3692
hieu.lagia@vn.bosch.com
www.bosch-pt.com
Français | 15
Disposal
Measuring tools, accessories and packaging should be sorted
for environmental-friendly recycling.
Do not dispose of measuring tools and batteries/rechargeable batteries into household waste!
Only for EC countries:
According to the European Guideline
2002/96/EC, measuring tools that are no
longer usable, and according to the European
Guideline 2006/66/EC, defective or used
battery packs/batteries, must be collected
separately and disposed of in an environmentally correct manner.
Batteries no longer suitable for use can be directly returned at:
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: +44 (0844) 736 0109
Fax: +44 (0844) 736 0146
E-Mail: boschservicecentre@bosch.com
Subject to change without notice.
Bosch Power Tools2 609 140 939 | (8.3.12)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.