Intrusion Alarm Systems | DS9370 Series Panoramic TriTech Detector
DS9370 Series Panoramic TriTech Detector
www.boschsecurity.com
u Up to 7.6 m (25 ft) mounting height
u Fully adjustable optics for coverage integrity and
customization
Each DS9370 Series TriTech® PIR/Microwave Detector model is panoramic and uses several patented processing techniques to provide excellent catch performance with freedom from false alarms. Each model can be mounted on ceilings as high as 7.6 m (25 ft). With three separate PIR sections that are fully adjustable, the DS9370 Series provides coverage integrity at all mounting heights, plus the ability to customize the coverage for specific areas.
Functions
Signal Processing
Uses passive infrared and microwave technologies to provide an alarm condition when both fields of protection are simultaneously activated. Alarm signals must meet the signaling requirements of both technologies to activate an alarm.
First Step Processing
FSP allows virtually instant response to human targets without sacrificing false alarm immunity to other sources. By adjusting its sensitivity based upon signal amplitude, polarity, slope and timing, FSP eliminates the need for the installer to select the sensitivity level for the application. Each sensor is processed individually and both must agree there is an alarm before the alarm relay is activated.
u High efficiency LED and light pipe system for easy
walk testing
u First Step processing (FSP)
Microwave Signal Processing
Adaptive processing adjusts to background disturbances. This helps to reduce false alarms while maintaining catch performance.
Microwave Supervision
Patented fully supervised microwave provides single technology coverage in the event the microwave subsystem fails.
Test Features
• High efficiency LED and light-pipe system provide walk test indication that is easily viewable from any angle and at any mounting height.
• Alarm memory feature allows detector to latch the alarm LED to aid in response.
• Remote LED walk-test control allows the LED to be enabled or disabled using a switched input without accessing the detector.
Certifications and approvals
Australia DS9370: AUS C-tick
China CCC 2004031901000038
Europe Complies with EN50131‑1, Grade 2
0m
8m
0ft
2m
4m
6m
4m
2m
0m
2m
4m
6m
8m
7ft
13ft
20ft
26ft
33ft
39ft
0ft
7ft
13ft
10m
12m
10m
12m
39ft
33ft
26ft
20ft
13ft
7ft
2 | DS9370 Series Panoramic TriTech Detector
Region Certification
Australia RCM
Europe CE 2014/30/EU EMC Directive (EMC);
2014/35/EU Low-Voltage Directive (LVD); 1999/5/EC Radio equipment and Telecommunications Terminal Equip­ment (R&TTE); 2011/65/EU Restriction of the use of certain hazardous substan­ces in electrical and electronic equip­ment(RoHS) [DS9370][DS9371] [DS9370-C]
EN5013 1
Belgium INCERT B-509-0013 (DS9370 only)
INCERT B-509-0013/b (DS9370-BEL only)
USA UL DS9370: ANSR: Intrusion Detection
Units (UL639), ANSR7: Intrusion Detec­tion Units Certified for Canada (cULus)
FCC ESV9370
Canada IC 1249A-12073
France AFNOR 28002000101A0
China CCC DS9370-CHI: 2009031901000550
Sweden INTYG 15-473 Alarm Class 1/2, Environmental
Class II (Larmklass 1/2 miljöklass II)
Brazil ANATEL Certificado Anatel 0871-03-1855
[DS9370 & DS9371]
Singapore iDA LPREQ-S0154-2004
Installation/configuration notes
Side View
Coverage Information
Provides 360° x 21 m (70 ft) diameter coverage when the detector is mounted at 3.7 m to 7.6 m (12 ft to 25 ft). Provides 360° x 15 m (50 ft) diameter coverage when the detector is mounted at 3 m (10 ft). 12 m (40 ft) when mounted at 2.4 m (8 ft). Pattern consists of 69 zones in 21 barriers. Each barrier is 11 m (35 ft) long and 1.5 m (5 ft) wide at 11 m (35 ft). The barriers are grouped into three groups of seven barriers each. Each group has vertical adjustment for customized coverage.
Technical specifications
Enclosure Design
Design: Modular chassis and hinged mounting
base design provide easy access to field setup switches and wiring.
Dimensions: 8.9 cm x 17.8 cm
(3.5 in. X 7 in.)
Material: High impact ABS plastic enclosure
Environmental Considerations
Top View
Operating Temperature: -40°C to +49°C (-40°F to +120°F)
For UL Certificated installations, 0°C to +49°C (+32°F to +120°F)
Radio Frequency Interference (RFI) Immunity:
No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m.
DS9370-C: Complies with Environmental Class II
(EN50130-5)
Microwave Frequency
DS9370 and DS9370-
10.525 GHz
BEL
DS9370-C 10.588 GHz
Mounting
Height Range: 3 m to 7.6 m (8 ft to 25 ft) recommended
Location: Mounts directly to ceiling or to standard 10.2 cm
(3.5 in.) octagonal electrical box.