Bosch D5060 User Manual

Page 1
Multiplex Point Programmer D5060
User’s Guide May 2004
1.0 Introduction
Use the multiplex point programmer (Figure 1 and Table 1) to program multiplex bus points for the Bosch
Security Systems D9412G, D9412, D9112, D7412G, D7412, D7212G, and D7212 Control Panels. In addition to programming points, the D5060 can also be used to program and read information from a D8125MUX.
Figure 1: Multiplex Point Programmer
EXT.
POWER
INTERROGATION MODE
YES NO
DOWN
MULTIPLEX POINT PROGRAMMER
SERIAL PORT MUX
ON
(HOLD)
3
2
1 4 56
0
OFF
(HOLD)
(HOLD)
9 #
ENTER
7 8
*
CLEAR
INTERROGATE
POINTS
UP
2.0 Installation
1. If using external power, attach the flying leads of
the included power cable to the output terminals of a 16.5 VAC transformer. Insert the plug end into the jack labeled EXT. POWER on the programmer. Refer to Figure 2, Figure 3, and Figure 4.
2. For control panels, use the serial cable provided to connect the D8125MUX to the D9412G, D9412, D9112, D7412G, D7412, D7212G, or D7212 Control Panel to the jack labeled SERIAL PORT on the programmer.
3. For MUX devices without DIP switches, use the multiplex programmer cable provided to connect the point to be programmed to the port labeled MUX POINTS as shown in Figure 2. Use the appropriate connector, either the alligator clips or the probes, to connect the programmer to a point.
For MUX devices with DIP switches, program the point using the DIP switches. Connect the programmer to the D8125 MUX as shown in Figure 3, using the C318 serial cable (Figure 4) to program the point number and point type into the D8125MUX.
Figure 2: Wiring Diagram When Installing MUX
Points Without DIP Switches
Table 1: D5060 LED Display Definitions
Display Definition
Adr A.dr bAd Err Lob noP PnL rSP tYP t.YP
Enter address Enter address for Interrogation Mode Battery voltage is below 15 V Point was not programmed correctly Battery voltage is below 16 V No response from point Communications with the D8125 failed Point responds to address Enter point type Enter point type for Interrogation Mode
1
12V IN OUT GND
ZONEX BUS
EXT.
POWER
INTERROGATION MODE
RESET
FIREMANUAL WALK TEST
SERIAL PORT MUX
2
PROG
+-+-+- +-
PORT
POWER A
MUX BUS A
POWER B
MUX BUS B
POINTS
4
1 - External power 2 - D8125 MUX 3 - MUX point without DIP switches (non-i
models)
4 - D5060 Multiplex Point Programmer
3
Page 2
D5060
It is not necessary to connect a MUX module to the D5060 to program MUX points with programming DIP switches.
Figure 3: Wiring Diagram When Installing MUX
Points With DIP Switches
1
12V IN OU T GND
ZONEX BUS
EXT.
POWER
INTERROGATION MODE
RESET
FIREMANUAL
PROG PORT
WALK TEST
SERIAL PORT MUX
3
2
+-+-+ -+-
POWER A
MUX BUS A
POWER B
MUX BUS B
POINTS
1 - External power 2 - D8125 MUX 3 - D5060 Multiplex Point Programmer
Figure 4: Cables Included with the Programmer
1
2
3.0 Programming Procedure
3.1 Powering the D5060
To turn the D5060 on, press and hold the [1] key until the unit beeps. To turn the unit off, press and hold the [#] and [*] keys simultaneously until the unit beeps.
After 5 min of inactivity, the programmer powers down automatically to conserve
3.2 Programming the Points
1. The D5060 displays the prompt Adr after it is
2. If the MUX device has no DIP switches, connect
3. Enter the point’s three-digit address. The address
power.
powered on. This indicates that it is ready to begin programming.
the D5060 to the point to be programmed (Figure
2). If the MUX device has DIP switches, program
the device using its DIP switches.
The point must be connected only to the programmer and not to the D8125MUX or the MUX bus.
If programming points for a Bosch Security Systems control panel, and if the MUX device has no DIP switches, connect the D8125MUX and the MUX device to be programmed to the D5060 for simultaneous programming (Figure 2). If the MUX device has DIP switches, program the device using its DIP switches.
must be between 1 and 255. Press [#].
4. The programmer displays tyP. Enter the number
3
corresponding to the point type you are programming (Table 2), then press [#]. The programmer alternately displays the address and the point type.
1 - C318 Serial Cable 2 - C319 External Power Supply Cable 3 - C320 Multiplex Programmer Cable
When programming a Mux Smoke point (decimal value 4 or 5, as shown in Table
2), an 18-second timer starts counting. Do not disconnect the Mux Smoke point until after the timer counts down to zero.
D5060 User's Guide
35262L Page 2 © 2004 Bosch Security Systems
Page 3
Table 2: Point Type Entry Code
Decimal Value Point Type
0 Remove point from D8125MUX 1 Contact 2 Sensor (or Single Point Module) 3 I/O Module 4 Mux smoke without low temperature 5 Mux smoke with low temperature 6 Dual point
5. Press [#] to program a point connected to the D5060 and the D8125MUX (if connected), or press [1] to program the D8125MUX only. If the MUX device has DIP switches, program the device using its DIP switches.
Press [*] at any time to back up through
6. If the point is programmed correctly, the unit
the sequence.
beeps once and displays Adr indicating that it is ready to program the next point. If the point was not programmed correctly, the unit sounds a three-beep error tone and one of the following messages displays:
D5060
4.1 Reading Information from the D8125MUX
1. To put the unit into Interrogation Mode, press
and hold [7] and [9] simultaneously until the unit beeps. The LED marked INTERROGATION MODE lights.
2. The display shows A.dr and the left-most
decimal point lights, prompting the user to enter a starting address. Enter an address followed by [#].
3. The Interrogation LED flashes. Press [#] to read
point information from the D8125MUX at that address.
4. Press [4] to read the previous address information
from the D8125MUX.
5. Press [6] to read the next address information
from the D8125MUX.
If communication between the unit and the D8125MUX fails, the unit sounds a three-
6. To exit Interrogation Mode, press and hold [*]
4.2 Reading Information from MUX
beep error tone and displays PnL.
until the unit beeps.
Points
Err: The point was not programmed correctly. PnL: Communications with the D8125MUX
failed.
7. Press [*] to clear the entry, or press [#] to reprogram.
3.3 Removing a Point from the
D8125MUX
1. Apply power to the D5060 and connect the programmer to the D8125MUX only.
2. Enter the address of the point you wish to remove.
3. When prompted for a point type, press [0]. Refer to Table 2.
4.0 Interrogation Mode
You can also use the programmer to read information from a D8125MUX and from MUX points. Refer to Section 2.0 Installation for D5060 installation information.
Disconnect all multiplex points from the D8125MUX and the multiplex bus before
1. To put the unit into Interrogation Mode, press
2. The display reads A.dr and the left-most decimal
3. Press [1].
4. When t.YP displays at the keypad, enter the
5. If a point responds to the address, the
6. To exit Interrogation Mode, press and hold [*]
reading multiplex point information.
and hold [7] and [9] simultaneously until the unit beeps. The LED marked INTERROGATION MODE lights.
point lights, prompting you to enter a starting address. Enter an address and press [#].
point type of the Mux point (Table 2) and press [#].
programmer beeps once and displays rSP. If the point does not respond, the unit beeps three times and the display reads noP.
until the unit beeps.
D5060 User's Guide
© 2004 Bosch Security Systems Page 3 35262L
Page 4
4
0
4
5.0 Batteries
This device is intended for use with AC power. Extended use of batteries is not recommended due to the power requirements of the unit.
This unit includes a feature that monitors the charge of the batteries. If the battery voltage falls below 16 V, the unit displays Lob. If the battery voltage falls below 15 V, the unit displays bAd. The display of Lob or bAd indicates insufficient power for programming. D8125MUX communications might still function properly even if these conditions exist.
To preserve the life of the batteries, remove them from the multiplex point programmer whenever you will not use the unit for any length of time.
6.0 Specifications
Table 3: Specifications
Description Value
Display Three-digit, seven-segment LED Power 16.5 VAC (20 VA to 50 VA) external
power source (recommended), or two 9 VDC batteries (optional)
This product is intended for use with AC power. Extended use of batteries is not recommended due to the power requirements of the unit.
© 2004 Bosch Security Systems 130 Perinton Parkway, Fairport, NY 14450-9199 USA Customer Service: (800) 289-0096; Technical Support: (888) 886-6189