Blaupunkt KP-S3, KP-S2 User Manual

Wireless Remote Keypad (KP-S3)
PPaarrttss DDeessccrriippttiioonn
1. Active LED (Green)
2. Transmission LED (Red)
3. Fault LED (Orange)
4. Away Arm Key
5. Home Arm Key
6. Key
7. Disarm Key
8. Mounting Hole Cover
9. Panic Alarm
Press both 1 and 3 key to trigger Panic alarm
10. Fire Alarm
Press both 4 and 6 key to trigger Fire alarm
11. Emergency Alarm
Press both 7 and 9 key to trigger Emergency alarm
12. Mounting Holes
13. Tamper Switch
The Tamper switch protects the PIR from unauthorized cover opening or removal from mounted surface.
14. Battery Insulator
PPaacckkaaggee CCoonntteenntt
1 x Remote Keypad 2 x wall plugs and screws 1 x CR2450 3V lithium battery (pre-installed)
For learning the Remote Keypad:
1. Pull out the battery insulator to activate battery.
2. Put the Control Panel into learning mode.
3. Press both # and keys to transmit learn code
4. Refer to Control Manual to complete the learning process.
The Remote Keypad has 2 mounting holes which are covered from the front for wall mounting.
1. Lift the mounting hole cover to reveal the 2 mounting holes.
2. Use the two mounting holes to mark position on the wall at chest height.
3. Drill holes into the wall in marked location.
4. Fix the keypad onto the wall with the screw and plugs provided.
5. Replace the mounting hole covers.
SSttaannddbbyy MMooddee
The Remote Keypad features a power saving feature. When no key is pressed for 5 seconds, the Remote Keypad will turn off automatically to conserve power. When any key is pressed, the Remote Keypad will wake up and turn on Active LED to indicate it is now under normal operation
KKeeyyppaadd SSeettttiinngg
The Remote Keypad features a Test (programming) mode for you to customize its setting. Before you start using the Remote Keypad, you should first finish configuration setting.
The Remote Keypad also feature a Keypad PIN code which is used to access the Test mode, To enter Test Mode, Enter
0000(Default Keypad PIN code) + key, the Active LED will begin to flash to indicate Keypad is now under Test Mode.
Under Test Mode, the following functions include:
Key
Function
” + “1
Transmit learn code (same as pressing both # and keys under normal mode)
” + “2”
Enable dual key Panic Alarm function
” + “3”
Enable dual key Fire Alarm function
” + “4”
Enable dual key Medical Alarm function
” + “5
Disable all dual key functions (Default)
LLeeaarrnniinng
g
OOppeerraattiioon
n
IInnssttaallllaattiioon
n
Remove
Remove
Mounting Hole
Mounting Hole
” + “6”
Change Keypad PIN Code:
1. Enter old code + “” Key
2. Enter new 4-digit code + “#” key
” + “8”
Enable Arming without Use PIN code function
” + “9”
Enable Arm with User PIN code function (Default)
“Disarm” twice
To leave Test Mode
AArrmm//HHoommee//DDiissaarrmm
If Remote Keypad is set to Arm with Use PIN code (” + “9” under Test Mode)
Away Arm
Enter a Control Panel User PIN Code + Arm Key
Home Arm
Enter a Control Panel User PIN Code + Home Key
Disarm
Enter a Control Panel User PIN Code + Disarm Key
If Remote Keypad is set to Arm without Use PIN code (” + “8 under Test Mode)
Away Arm
Press Arm Key
Home Arm
Press Home Key
Disarm
Enter a Control Panel User PIN Code + Disarm Key
DDuuaall KKeeyy AAllaarrmm FFuunnccttiioonn
Dual Key Alarm function will activate alarm when both keys are pressed at the same time. To use the functions, please enable them under Test Mode. (Default are disabled)
1 + 3
Panic Alarm
4 + 6
Fire Alarm
7 + 9
Emergency Alarm
LLEEDD IInnddiiccaattoorrss
AAccttiivvee LLEEDD
The Active LED light up whenever any key is pressed.
Off
Keypad in Standby Mode
Green LED On
Keypad in Normal Operation
Green LED Flash
Keypad in Test Mode
TTrraannssmmiissssiioonn LLEEDD
The Transmission LED lights up whenever the Keypad transmits a radio signal
FFaauulltt LLEEDD
The Fault LED light up when the Keypad is activated under fault condition
Orange LED On
Keypad tamper switch is triggered
Orange LED Flash
Keypad is under low battery
BBaatttteerryy
The Remote Keypad uses one 3V CR2450 lithium battery as its power source. It also features low battery detection function to notify the Control Panel when battery voltage is low.
When the Remote Keypad is on low battery, follow the procedure below to change the battery.
1. Open the back cover.
2. Remove the old battery carefully with a minus screw driver by inserting the screw into gap in battery compartment, the lift the battery as picture below.
Do not remove the battery by hand to avoid risk of damaging the battery compartment.
3. Press any key several times to fully discharge.
4. Insert the new battery observing correct polarity.
5. Replace the back cover.
FFaaccttoorryy RReesseett
If you forget your Keypad PIN code, or the Remote Keypad has any problem, you can reset the Remote Keypad to factory default.
1. Open the back cover.
2. Open the back cover and remove the battery.
3. Press and hold 3 key and insert battery.
4. The Remote Keypad will sound 3 short beeps.
5. Release 3 key, the reset process is now complete
EEnnvviirroonnmmeennttaall CCoonnddiittiioonn
-10°C to 40°C, relative humidity 85% non-condensing.
RRaaddiioo
868 MHz
SSppeecciiffiiccaattiioon