Table of Contents
Connecting Instrument to PC ...................................................................................................... 3
USB (Virtual COM) Configuration ............................................................................................... 3
SOUT< Output > [CR] .................................................................................................................. 5
GOUT[CR] .................................................................................................................................... 5
VOLT< preset0/1/2/3><Voltage>[CR] ......................................................................................... 5
CURR< preset0/1/2/3><Current> [CR] ....................................................................................... 5
SOVP<voltage >[CR] .................................................................................................................... 5
GETD[CR] ..................................................................................................................................... 5
SOCP<Current>[CR] ..................................................................................................................... 5
GOVP[CR] .................................................................................................................................... 5
GOCP[CR] .................................................................................................................................... 5
SETD<preset0/1/2/3><VOLTAGE> .............................................................................................. 6
<CURRENT>[CR] .......................................................................................................................... 6
GETS<preset0/1/2/3>[CR] .......................................................................................................... 6
GABC[CR] ..................................................................................................................................... 6
SABC< preset0/1/2/3>[CR] ......................................................................................................... 6
GDLT<{0-5}>[CR] ......................................................................................................................... 6
SDLT <location {0-5}; time {00-20}>[CR] ..................................................................................... 6
GSWT<location {0-2}> ................................................................................................................. 6
SSWT<location {0-2} time {000-600}> [CR] ................................................................................. 6
RUNP< first {0-2}; end {0-2}>[CR] ............................................................................................... 6
STOP[CR] ..................................................................................................................................... 7
SESS[CR] ...................................................................................................................................... 7
ENDS[CR] ..................................................................................................................................... 7
GALL[CR] ...................................................................................................................................... 7
SETM ........................................................................................................................................... 8
1. USB Interface Connection
Users can remotely control the power supply via PC over the USB interface. Upon installation of the USB driver, the PC can control the instrument over virtual COM.
Connecting Instrument to PC
a) Download the USB drivers from www.bkprecision.com . b) Connect the included USB cable to the power supply and the USB port on the PC. c) When Windows recognizes the USB connection, do not follow the default Windows driver
installation wizard. Simply run the setup file from the downloaded USB drivers and follow the prompt to install drivers.
d) The computer will recognize the instrument as a USB (virtual COM) device, it will be
detected as a serial COM port. Windows will automatically assign a COM port to the instrument. Please verify which COM port Windows has assigned by going into Device Manager.
USB (Virtual COM) Configuration
The following serial port settings are used by the power supply.
Baudrate: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None