Data Sheet
Synthesized In-Circuit LCR/ESR Meters
Models 885 & 886
Specifications 885 & 886
Test Frequencies 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz (model 886 only)
Frequency Accuracy ± 0.1%
Test Levels 1 Vrms, 0.25 Vrms, 0.05 Vrms, 1 Vdc (for DCR)
Level Accuracy ± 5%
Output Impedance 100 Ω, ± 5%
Impedance (Z)
Model 885
The B&K Precision models 885 and 886 synthesized in-circuit LCR/ESR
meters are the first handheld meters of this type on the market, with a wide
range of test frequencies up to 10 kHz for model 885 and 100 kHz for
model 886, many measurement parameters including Z, L, C, DCR, ESR, D,
Q, and Ø as well. The 885 and 886 are designed for both component
evaluation on the production line and fundamental impedance testing for
benchtop applications. With a built-in direct test fixture, you can test the lead
components very easily. The optional 4-wire test clip can give a convenient
connection to larger components and assemblies with the accuracy of 4-wire
testing. The LCR meters offer fast, reliable, and versatile testing at low cost,
making the 885 and 886 the most advanced handheld LCR meters available
on the market today.
Features & Benefits
■ Measurement parameters: Z, L, C, DCR, ESR, D, Q, and Ø
■ Test conditions: 100 Hz, 120 Hz, 1 kHz, 10 kHz,
100 kHz (model 886 only), 1 Vrms, 0.25 Vrms, 0.05 Vrms
■ 0.5% basic accuracy
■ Dual LCD display
■ SMD surface mount tweezer probe included
■ Very quick response, user-friendly
■ Fully auto/manual selection
■ DC resistance measurement
■ Rechargeable battery / AC powered
SMD Probe
(included)
Capacitance (C)
Inductance (L)
General
Operating Temperature 32 ˚F to 104 ˚F (0 ˚C to 40 ˚C)
Storage Temperature -4 ˚F to 158 ˚F (-20 ˚C to 70 ˚C)
Relative Humidity up to 85%
Battery Type Ni-MH or Alkaline (2 x AA size)
Battery Charge Constant current 150 mA approximately
Battery Operating Life 2.5 hours typical
AC Operation 110 V/220 VAC, 60/50 Hz with proper adapter*
Low Power Warning under 2.2 V
Dimensions (LxWxH) 6.9” x 3.4” x 1.9" (174 x 86 x 48mm)
Weight 1.1 lbs (470 g)
Standard Accessories
Optional Accessories
* The 885 and 886 include a 110 V AC adapter. For a 220 V AC adapter, order model
885 EXD or 886 EXD.
Frequency Maximum Minimum Best Resolution
DCR 20 MΩ 0.1 Ω 0.001
100 Hz 20 MΩ 0.1 Ω 0.001
120 Hz 20 MΩ 0.1 Ω 0.001
1 kHz 20 MΩ 0.1 Ω 0.001
10 kHz 20 MΩ 0.1 Ω 0.001
100 kHz 10 MΩ 0.1 Ω 0.001
Frequency Maximum Minimum Best Resolution
100 Hz 15.91 mF 79.57 pF 0.001
120 Hz 13.26 mF 66.31 pF 0.001
1 kHz 1.591 mF 7.957 pF 0.001
10 kHz 159.1 µF 0.795 pF 0.001
100 kHz 15.91 µF 0.159 pF 0.001
Frequency Maximum Minimum Best Resolution
100 Hz 31.83 kH 159.1 µH 0.001
120 Hz 26.52 kH 132.6 µH 0.001
1 kHz 31.83 kH 15.91 µH 0.001
10 kHz 318.3 H 1.591 µH 0.001
100 kHz 31.83 H 0.159 µH 0.001
Three-Year Warranty
User manual, SMD probe, rechargeable battery,
shorting bar, and AC adapter*
Carrying case, TL08C Kelvin clip, TL885B 4-wire test clip,
BC 885 110 V AC adapter, and BC 885 EXD 220 V AC
adapter
Technical data subject to change
© B&K Precision Corp. 2013
v060413