ENGLISH
Index
1. General information
1.1 Introduction ...................................................................pag. 10
1.2 General safety ...............................................................pag. 10
1.3 General ............................................................................pag. 10
1.4 Technical speci cation ..............................................pag. 10
1.5 Overall dimensions ..................................................... pag. 11
2. Installation
2.1 Cable note ......................................................................pag. 11
2.2 Fixing the structure ....................................................pag. 11
2.3 Springs mounting .......................................................pag. 12
2.4 Instal the arm ...............................................................pag. 13
2.5 Align the arm ................................................................pag. 13
2.6 Balancing the arm ....................................................... pag. 14
2.7 Optionals ........................................................................ pag. 14
2.8 Electrical connections ................................................pag. 14
3. Use and maintenance
3.1 General safety ...............................................................pag. 15
3.2 Warnings .........................................................................pag. 15
3.3 Use .................................................................................... pag. 15
3.4 Manual manoeuvre .................................................... pag. 15
3.5 Routine maintenance ................................................ pag. 15
- 10 -
ENGLISH
1.3 GENERAL
The automatic electromechanical barrier is designed to control passage openings up to 8 metres wide, for a maximum torque applicable to the bar shaft of 1150 Nm, in compliance with European standards. It is suitable for industrial applications and it is the ideal solution for managing vehicle tra c.
1.1 INTRODUCTION
Please read it carefully before installing the appliance, before using it and before routine or extraordinary maintenance work.
The notices preceded by this symbol provide important information, the non-compliance with such instructions voids the manufacturer’s guarantee.
OPERATIONS THAT, IF NOT CARRIED OUT CORRECTLY, CAN BE RISKY, ARE INDICATED WITH THE FOLLOWING SYMBOLS
ELECTROCUTION CRUSHING
The INSTALLATION, USE AND MAINTENANCE handbook is for installers, users and maintenance engineers
The Company is not liable for injury to people or animals or damage to things in the case of applications that exceed the limits speci ed on the enclosed technical data sheet or by a use di erent from what the appliance has been designed.
Warning! Observe all the instructions, improper installation can result in serious injury.
1.2 GENERAL SAFETY
• Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current stan­dards. Keep nylon or polystyrene bags out of children’s reach.
• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any bu er batteries, if  tted.
• Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3,5 mm.
• Check that a di erential switch with a 0,03A threshold is  tted just before the power supply mains.
• The outputs are not of type SELV (separated extra-low voltage), therefore it must not be possible to reach them.
• Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing, according to and in compliance with the applicable directives and technical standards.
• The Company decline s all responsibility with respect to the automation safety and correct operation when other manufacturer’s components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised by the Company.
• Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation area.
• Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation.
• Do not allow children to play with the equipment.
• The equipment may be used by children aged over 8 years old and by people with reduced physical, sensory or mental capabilities, or without experience or the necessary knowledge, provided they are supervised or after they have received instructions relating to the safe use of the equipment and have understood the dangers inherent in it.
• Cleaning and maintenance meant to be performed by the user must not be performed by unsupervised children.
• Anything which is not expressly provided for in the present instructions, is not allowed.
1.4 TECHNICAL SPECIFICATIONS
Power...................230Vac/115Vac ±10% 50/60Hz
Motor.....................230Vac 900RPM 14uF 0.50kW
Absorbed power.................................................650W
Control unit.............................................CSB-Xtreme
Impact safety...................................................Encoder
Opening time...............4.5
÷ 6.0
s **
Arm length................................4 ÷ 8 m
Working temp..............-30*** +60°C
Manoeuvres in 24h.....................3 000
Protection level..............................IP 54
Net weight.............................................................95 kg
Gross weight.........................................................98 kg
Sound pressure level...................LpA≤70 dB (A)