1) GENERAL OUTLINE Cellula 130 Mod. recessed photocell to be fitted externally,
consisting of a pair of transmitters and receivers having a double relay which is normally energised, as provided for by
CELLULA130
the relevant standards. This product complies with the recognised technical standar­ds and safety regulations. We declare that this product is in conformity with the following European Directives: 73/23/EEC, 89/336/EEC (and subsequent amendments).
2) TECHNICAL SPECIFICATIONS
Power supply:20÷31 V~/
range: 30m(reduced in case of fog / rain); Relay contacts:1A at 24V~/
protection:IP54. Dimensions: see Fig. 1.
; Working temperature:-15°C to +70°C; Degree of
3) PHOTOCELL FITTING
The photocells should be installed between 40 and 60 cm in height, in the following ways:
• Installation on a wall (g. 1): check that the securing surfaces are
level and parallel. Make 2 ø 4 mm holes using the back mask as a drilling template. Then insert the screw anchors supplied and proceed to securing and connecting the photocell.
• Installation on an iron pillar (g. 2): check that the securing
surfaces are level and parallel. Fix the back mask to make 2 ø
2.5 mm holes where the self-tapping screws are to be fixed.
• If there is no pillar or wall for the photocells to be secured
to, request the appropriate metal posts. The posts can be directly secured onto a concrete base by means of three screw anchors.
Perfect alignment is ensured by the adjustment slots provi-
ded in the base (fig.3).
In the case where two pairs of photocells are installed close
to each other, cross the RX-TX positions (fig. 4).
4) CONNECTION TO THE TERMINAL BOARD (Fig. 5) Transmitter - Receiver 1-2 Power supply 3-4 Normally closed contact (When photocells are aligned the
contact opens).
3-5
Normally open contact (When photocells are aligned the
contact closes).
To connect more than one pair of photocells, connect the con­tacts of each RX receiver in series (fig. 4).
Warning! The installation must be carried out by qualified personnel.
5) PHOTOCELL ALIGNMENT
Correct photocell alignment is achieved when the LED of the RX receiver (fig. 5) lights up and stays on, even after fitting the cover provided with the concentration lens. When an obstacle is present between the RX receiver and TX transmitter, the LED goes off and opens the contact.
; Absorbed power:70 mA; Max
1) GENERALITES
Cellule photoélectrique Mod. Cellula 130 encastrée et pour application extérieure, constituée d’un couple émetteur récep­teur avec double relais normalement excité comme prévu par
les normatives. Ce produit est conforme aux règles reconnues de la technique et
aux dispositions de sécurité. Nous certions sa conformité avec les directives européennes suivantes: 73/23/CEE, 89/336/CEE
(et modifications successives).
2) CARACTERISTIQUES TECHNI
Alimentation:20÷31 V~/
Loading...