FOTOCELLULA PHOTOCELL
Fig. 1 Fig. 2
Fig. 4
Fig. 5
Fig. 3
36
80
29
TX
RX
TX
RX
1
1 2 3 4 5
2
RX
TX
LED
NC
NO
COM
20-31V~=
(+) (+)
(VT X)
20-31V~=
35
40-60 cm
RX
RX
RX
PHOTOCELLULE PHOTOZELLE
FOTOCÉLULA FOTOCÉLULA
Via Lago di Vico 44
36015 SCHIO (VICENZA)
Tel.naz. 0445696511
Tel.int. +39 0445696533
Fax 04 4569652 2
INTERNET www.bft.it
E-MAIL sales@bft.it
ISTRUZIONI DI INSTALLAZIONE
INSTALLATION MANUAL
INSTRUCTIONS D’INSTALLATION
GEBRAUCHSANLEITUNG
INSTRUCCIONES DE INSTALACIONI
INSTRUÇÕES DE INSTALAÇÃO
D811289 ver.05 11-06-08
1) GENERAL OUTLINE
Cellula 130 Mod. recessed photocell to be fitted externally,
consisting of a pair of transmitters and receivers having a
double relay which is normally energised, as provided for by
CELLULA130
the relevant standards.
This product complies with the recognised technical standards and safety regulations. We declare that this product is in
conformity with the following European Directives: 73/23/EEC,
89/336/EEC (and subsequent amendments).
2) TECHNICAL SPECIFICATIONS
Power supply:20÷31 V~/
range: 30m(reduced in case of fog / rain); Relay contacts:1A
at 24V~/
protection:IP54. Dimensions: see Fig. 1.
; Working temperature:-15°C to +70°C; Degree of
3) PHOTOCELL FITTING
The photocells should be installed between 40 and 60 cm in
height, in the following ways:
• Installation on a wall (g. 1): check that the securing surfaces are
level and parallel. Make 2 ø 4 mm holes using the back mask
as a drilling template. Then insert the screw anchors supplied
and proceed to securing and connecting the photocell.
• Installation on an iron pillar (g. 2): check that the securing
surfaces are level and parallel. Fix the back mask to make 2 ø
2.5 mm holes where the self-tapping screws are to be fixed.
• If there is no pillar or wall for the photocells to be secured
to, request the appropriate metal posts. The posts can be
directly secured onto a concrete base by means of three
screw anchors.
Perfect alignment is ensured by the adjustment slots provi-
ded in the base (fig.3).
• In the case where two pairs of photocells are installed close
to each other, cross the RX-TX positions (fig. 4).
4) CONNECTION TO THE TERMINAL BOARD (Fig. 5)
Transmitter - Receiver
1-2 Power supply
3-4 Normally closed contact (When photocells are aligned the
contact opens).
3-5
Normally open contact (When photocells are aligned the
contact closes).
To connect more than one pair of photocells, connect the contacts of each RX receiver in series (fig. 4).
Warning! The installation must be carried out by qualified
personnel.
5) PHOTOCELL ALIGNMENT
Correct photocell alignment is achieved when the LED of the
RX receiver (fig. 5) lights up and stays on, even after fitting the
cover provided with the concentration lens. When an obstacle
is present between the RX receiver and TX transmitter, the LED
goes off and opens the contact.
; Absorbed power:70 mA; Max
1) GENERALITES
Cellule photoélectrique Mod. Cellula 130 encastrée et pour
application extérieure, constituée d’un couple émetteur récepteur avec double relais normalement excité comme prévu par
les normatives.
Ce produit est conforme aux règles reconnues de la technique et
aux dispositions de sécurité. Nous certions sa conformité avec
les directives européennes suivantes: 73/23/CEE, 89/336/CEE
(et modifications successives).
2) CARACTERISTIQUES TECHNI
Alimentation:20÷31 V~/