USER’S MANUAL
Thank you for buying this product, our company is sure that you will be more than satisfied with the products performance. The product is supplied with
D811184A_04
a WARNINGS leaflet and an INSTRUCTION MANUAL. These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product complies with the recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 89/336/EEC and 73/23/EEC (and subsequent amendments).
1) GENERAL OUTLINE
The ARIES control unit has been designed for swing gates. It can be used for one or two gate controllers. The control unit mod. ARIES P can also be used to perform opening of a single actuator while keeping the other one closed (pedestrian access).
2) FUNCTIONS
STOP: In all cases: it stops the gate until a new start command is given. PHOT: Functions can be set with Dip-Switch.
Activated during closing. Activated during opening and closing.
Rapid closing
ON: When the position of the gate photocells is exceeded, during both opening and closing, the gate automatically starts to close even if TCA is
activated. We recommend setting DIP3 to ON (photocells only activated during closing).
Blocks impulses
ON: During opening, START commands are not accepted. OFF: During opening, START commands are accepted.
Photocells
ON: Photocells only activated during closing. OFF: Photocells activated during opening and closing.
Automatic closing time (TCA)
ON: Automatic closing activated (can be adjusted from 0 to 90s)
Preallarm (mod. ARIES P only)
ON: The flashing light turns on abt 3 seconds before the motors start.
ENGLISH
FOR THE INSTALLER: check the boxes you are interested in.
START: four-step logic Gate closed During opening Gate open
During closing
After stop
ATTENTION: Dip non used in mod. ARIES (always in OFF set).
3) MAINTENANCE AND DEMOLITION The maintenance of the system should only be carried out by qualified personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force.
Batteries must be properly disposed of.
WARNINGS Correct controller operation is only ensured when the data contained in the present manual are observed. The compa ny is not t o be he ld respon si ble for any damage resulti ng fro m failur e to observe the installat io n stan dards an d the instru ct ions contained in the pres ent manual .
The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication.
it stops and activates TCA
it stops and does not activate TCA
it opens it opens
it closes
it starts opening
START: two-step logic
it stops and activats TCA (if activated)
it closes
it opens
it opens
SCA: Gate open indicating light
off on on
flashing
ARIES/ARIES-P - Ver. 04 -
5
Page 4
ENGLISH
Thank you for buying this product, our company is sure that you will be more than satisfied with the products performance. The product is supplied with a WARNINGS leaflet and an INSTRUCTION MANUAL. These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product complies with the recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 89/336/EEC and 73/23/EEC (and subsequent amendments).
1) GENERAL OUTLINE
The ARIES control unit has been designed for swing gates. It can be used for one or two gate controllers. The control unit mod. ARIES P can also be used to perform opening of a single actuator while keeping the other one closed (pedestrian access).
2) GENERAL SAFETY WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.
The Warnings leaflet and Instruction booklet supplied with this
product should be read carefully as they provide important information about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene bags out of childrens reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/EEC, 73/23 /EEC, 98/37/ECC and subsequent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an earth terminal.
The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
Do not allow persons or children to remain in the aut omation operation area.
Keep radio control or other control devices out of childrens reach, in order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions, is not allowed.
3) TECHNICAL SPECIFICATIONS
Power supply:...............................................................230V ± 10% 50Hz
Absorption on empty:.................................................................0.5A max
Output power for accessories:..........................................24V~ 6VA max
Max relay current:................................................................................8A
Max power of motors:...............................................................300 W x 2
Torque limiter:.................................................Self-transformer with 4 pos
Limit switch:................................................................Adjustable run time
INSTALLATION MANUAL
Panel dimensions:.........................................................................See fig.1
Cabinet protection:............................................................................IP55
Working temperature:...............................................................-20 +55° C
4) TERMINAL BOARD CONNECTIONS (Fig.2)
CAUTION: Keep the low voltage connections completely separated from the power supply connections.
Fig.3 shows the fixing and connection method of the drive condensers whenever they are not fitted to the motor.
JP5
1-2 Single-phase power supply 230V ± 10%, 50 Hz (1=L/2=N). For connection to the mains use a multiple-pole cable with a minimum cross section of 3x1.5mm standard (by way of example, if the cable is not shielded it must be at least equivalent to H07 RN-F while, if shielded, it must be at least equivalent to H05 VV-F with a cross section of 3x1.5mm
JP3
3-4 (mod.ARIES-P) 230V 40W max. blinker connection. 5-6 (mod.ARIES) 230V 40W max. blinker connection. 7-8-9 Motor M1 connection - 8 common, 7-9 start. 10-11-12 Motor M2(r) connection - 11 common, 10-12 start.
JP4
13-14 Open-close button and key switch (N.O.). 13-15 Stop button (N.C.). If unused, leave bridged. 13-16 Photocell or pneumatic edge input (N.C.). If unused, leave bridged. 17-18 24V 3W max. gate open warning light. 18-19 24V~ 0.25A max. (6VA) output (for supplying photocell or other device). 20-21 Antenna input for radio-receiver board (20 signal - 21 braid). 22 Common terminal (equivalent to terminal 13). 23 Terminal for pedestrian control. It moves the leaf of motor M2 connected to terminal 10-11-12. This terminal is available only in ARIES-P control unit.
JP2
25-26 2nd radio channel output of the double-channel receiver board (terminals not fitted on ARIES but fitted on ARIES-P) contact N.O.
JP1 Radio-receiver board connector 1-2 channels.
5) FUNCTIONS DL1: Power-on Led
It is switched on when the board is electrically powered.
START: four-step logic: (DIP5 OFF)
gate closed:..................................................................................it opens
during opening:............................................... it stops and activates TCA
gate open:................................................................................... it closes
during closing:.................................... it stops and does not activate TCA
after stop:.........................................................................it starts opening
START: two-step logic: (DIP5 ON)
gate closed:..................................................................................it opens
during opening:................................it stops and activats TCA (if activated)
gate open:....................................................................................it closes
during closing:..............................................................................it opens
after stop:.....................................................................................it opens
STOP: In all cases: it stops the gate until a new start command is given. PHOT: Functions can be set with DIP-SWITCH.
Activated during closing if DIP3-ON. Activated during opening and closing if DIP3-OFF.
SCA: Gate open indicating light.
with gate closed:...................................................................................off
when gate is opening:...........................................................................on
with gate open:.......................................................................................on
when gate is closing:.....................................................................flashing
6) DIP-SWITCH SELECTION DIP1 Rapid closing
ON: When the position of the gate photocells is exceeded, during both opening and closing, the gate automatically starts to close even if TCA is activated. We recommend setting DIP3 to ON (photocells only activated during closing). OFF: Function not activated.
DIP2 Blocks impulses
ON: During opening, START commands are not accepted. OFF: During opening, START commands are accepted.
DIP3 Photocells
ON: Photocells only activated during closing. OFF: Photocells activated during opening and closing.
2
of the type indicated in the above-mentioned
2
).
D811184A_04
12
-
ARIES/ARIES-P - Ver. 04
Page 5
INSTALLATION MANUAL
DIP4 Automatic closing time (TCA)
D811184A_04
ON: Automatic closing activated (can be adjusted from 0 to 90s). OFF: Automatic closing not activated.
DIP5 Control logic
ON: 2-step logic is activated (see start paragraph). OFF: 4-step logic is activated (see start paragraph).
DIP6: Preallarm (mod.ARIES P only)
ON: The flashing light turns on abt 3 seconds before the motors start. OFF The flashing light turns on simultaneously with the start of the motors.
ATTENTION: Dip non used in mod. ARIES (always in OFF set).
7) TRIMMER ADJUSTMENT
TCA This adjusts the automatic closing time, after which time the gate
automatically closes (can be adjusted from 0 to 90s). TW This adjusts the motor working time, after which time the motor stops (can be adjusted from 0 to 40s).
TDELAY This adjusts the closing delay time of the second motor (M2).
8) MOTOR TORQUE ADJUSTMENT
The ARIES control unit has electric torque adjustment which allows the motor force to be adjusted. The adjustment should be set for the minimum force required to carry out the opening and closing strokes completely. Adjustment is carried out by moving the connection 55 (fig.3) on the tran­sformer sockets as described below: Pos.T1 1st TORQUE (MINIMUM TORQUE) Pos.T2 2nd TORQUE Pos.T3 3rd TORQUE Pos.T4 4th TORQUE (MAXIMUM TORQUE) 4 motor torque values can be obtained. To gain access to the torque adjustment sockets, disconnect the mains supply and remove the protective case P of the transfomer. CAUTION: Excessive torque adjustment may jeopardise the anti-squash safety function. On the other hand insufficient torque adjustment may not guarantee correct opening or closing strokes.
ENGLISH
9) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force.
Batteries must be properly disposed of.
WARNINGS Correct controller operation is only ensured when the data contained in the present manual are observed. The co mp any is not to be he ld respon si ble for any dama ge res ulting from failure to observ e the instal la tion s tandards and t he ins tr uctions contain ed in the presen t manual.
The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication.
ARIES/ARIES-P - Ver. 04 -
13
Page 6
125
Fig. 1
D811184A_04
¿5
195
90
Fig. 2
ARIES ARIES P
JP5
COMM START
STOP PHOT
SCA
0V
24Vac
COMM
1 2
JP3
5 6 7 8
9 10 11 12
JP4
13 14 15 16 17 18 19 20 21 22
JP2
25
26
JP12
MOT1
JP13 JP14
MOT2
JP15
NOII¡ CH
NL230V ± 10%
MAX 40 W
M1
M2
NO NC
NC
ANTEN.
NO
NL230V ± 10%
MAX 40 W
M1
(r)
M2
NO NC
NC
ANTEN.
(r)
COMM START
STOP PHOT
24Vac
COMM
PED.
SCA
0V
225
3
8
1
JP5
1 2
JP3
3 4
JP12
7
MOT1
8
JP13
9
JP14
10
MOT2
11
JP15
12
JP4
13 14 15 16 17 18 19 20 21 22
23
JP2
25
NOII¡ CH
26
22
-
ARIES/ARIES-P - Ver. 04
Page 7
COLLEGAMENTO CONDENSATORI IN CENTRALINA - CONNECTIONS TOTHE TERMINALBOARD FORTHECAPACITOR
CONNECTION DESCONDENSATEURS DANS LACENTRALE - KONDENSATOREN VERBINDUNG INDERSTEURUNG
CONEXIONDELLOSCONDENSADORES ENLACENTRAL DEMANDO- LIGAÍE CONDENSADORES NACENTRAL DE MANDO
P
D811184A_04
12
0
12
55
0V
L
T2
T3
44
55
JP6
JP7
JP11
66
DL1
T 1A 110V
T 0,5A 230V
JP12
T 5A 110V
T 2,5A 230V
2
1
JP5
6
5
JP3
JP13
9
8
7
11
12
10
ARIES/ARIES-P - Ver. 04 -
T4
TDELAY
JP14 JP15
N
221133
Fig. 3
1 2 3 4 5 6
ON
DIP