The Ranger Pro Wireless Condition Monitoring vibration
sensor allows you to monitor velocity, acceleration, and
temperature plus timebase waveforms, spectra, and
PeakDemod spectrum. It's built for plant managers and
operators in power generation, oil and gas, and related
industrial markets.
The Bently Nevada Ranger Pro Wireless Condition Monitoring
sensor enables you to:
l Monitor and optimize the reliability of low- and
medium-criticality machines.
l Establish or expand existing reliability programs.
l Make maintenance decisions based on current data.
l Reduce maintenance costs.
l Decrease unplanned machine failures.
l Increase machinery life.
125M5237 Rev. H
Ranger Pro Wireless Condition Monitoring is a simple, easy to
implement solution for use in hazardous or difficult to access
environments where wired solutions are impractical.
Use the Ranger Pro Wireless Condition Monitoring to get
immediate notifications, short- and long-term trending data,
and diagnostic reporting. No more "reporting by walking
around."
Quickly publish overall data through Modbus to third-party
tools or spectra and waveform data through Generic Client or
Hart IPInterface to Bently Nevada System 1 software.
Configure Ranger Pro devices over-the-air using third-party
tools or the Ranger Pro Configuration software.
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
System 1Support
Machinery Applications
Ranger Pro Wireless Condition Monitoring is a
vibration sensor for machines with rollerelement bearings including:
l Agitators
l Air compressors
l Ball mills
l Blowers
l Centrifuges
l Cooling tower fans and pumps
l Motors
l Small reciprocating compressors
l Small hydro and steam turbines
Hardware Features
You can configure Ranger Pro Wireless
Condition Monitoring to work in a variety of
environments and applications.
l Uniaxial and tri-axial capable velocity and
acceleration detection.
l Environment temperature reporting.
l Mounting hardware options to fit most
battery.
l IP67 dust and water resistant.
l Embedded sensors connect using the
ISA100 wireless or WirelessHART network
protocols.
l Can act as a router for other Ranger Pro
sensors.
After installing Ranger Pro devices, you can set
a start time for multiple devices to begin data
acquisition using Ranger Pro Configuration
Software.
Ranger Pro collects overall vibration,
temperature measurements, timebase
waveforms, spectra, and Peak Demod
spectrum using Generic Client Interface (GCI)
for ISA100 Ranger Pro devices and HARTIPfor
WirelessHARTRanger Pro devices with System 1
software. You can filter overall and dynamic
timebase and spectra data.
Network Installation
A typical network installation uses several
Ranger Pro Wireless Condition Monitoring
sensors, Ranger Pro repeaters, wireless device
managers, and access points. Ranger Pro is
available in either uniaxial or tri-axial vibration
detection.
You can use third-party tools or the Ranger Pro
Configuration software to quickly provision and
configure Ranger Pro devices over-the-air.
Wireless range varies depending on
environmental obstacles, gateway antenna
type, and the orientation of the sensor relative
to the gateway antenna.
2/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Hazardous Area Approvals
WARNING
HAZARDOUS
ENVIRONMENT
Risk of explosive atmosphere.
DO NOT OPEN WHEN AN
EXPLOSIVE ATMOSPHERE IS
PRESENT. POTENTIAL
ELECTROSTATIC CHARGING
HAZARD. The equipment shall
only be cleaned with a damp
cloth when deployed in a
hazardous area.
Compliance and Certifications
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any interference
received, including interference that may
cause undesired operation.
CSA
Class I, Division 1 Groups A, B, C, D
ATEX/IECEx Standards
Ex ia IIC T4 Ga
Ex ia IMa
RoHSDirectives
2011/65/EU
3/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Specifications
FeatureCharacteristicValue
AccelerometersAxis1 or 3 axis (ISA100)
3 axis only (WirelessHART)
Sensing element Piezoelectric ceramic
Amplitude range ±20 g peak
Measurement
accuracy
Transverse
sensitivity (Typ.)
±5% (160 Hz) Z-axis
±10% (160 Hz) X and Y axis
7%
4/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
FeatureCharacteristicValue
Trending Variables
Acceleration
Acceleration
frequency range
Z axis: 5 Hz (±3dB) to 10 kHz (±3dB)
X and Y axis: 5 Hz (±3dB) to 4 kHz (±3dB) (tri-axial sensor
only)
Acceleration
0 – 200 m/s2 (0 - 20 g)
amplitude range
Acceleration units /
g or m/s2 / peak or rms
subunits
Fmin 2, 5, 10, 100, 200 (Hz)
Fmax
200, 500, 1000, 2000, 5000, 10000‡Hz
‡ 10,000 only on Z-axis
Velocity
Velocity frequency
5 – 2000Hz
range
Velocity amplitude
0 – 50 mm/s (0 - 2 in/s)
range
Velocity units /
in/s or mm/s peak or rms
subunits
Fmin 5, 10Hz
Fmax 200, 500, 1000, 2000Hz
Peak Demod
Peak Demod PkZ axis only
Parameters based on PeakDemod Spectrum settings
below
Measurement
6, 8, 12, 24, 48, 168, 336, 672 hours
interval
Output data Overall values using:
l Modbus from device gateway
l Generic Client Interface (GCI) for ISA100 devices
l HARTIPfor WirelessHART
5/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
FeatureCharacteristicValue
Waveforms and
Spectra
Acceleration
Acceleration
X, Y and Z axis depending on sensor model
waveform
Fmin 2, 5, 10Hz
Fmax 200, 500, 1000, 2000, 5000, 10000 ‡ Hz
‡ Z-axis only
Number of samples 1024, 2048, 4096, 8192
Units/subunits g or m/s2 / peak
Velocity
Velocity spectra X, Y and Z axis depending on sensor model
Fmin 5, 10
Fmax 200, 500, 1000, 2000
Number of lines 400, 800, 1600, 3200
Units/subunits in/s or mm/s / rms
Peak Demod
Temperature
sensor
Peak Demod
Z-Axis only
spectrum
Fmax 200, 500, 1000, 2000, 5000Hz
Demod Band Min 500, 1000, 2000, 5000Hz Max 40000 Hz
Wireless range 150 meters sensor to access point, 100 meters sensor to
sensor, line of sight. (Actual range depends on obstacles
present, gateway antenna type, and orientation of the
sensor relative to the gateway antenna.)
Type
Replaceable D size 3.6V lithium-thionyl chloride.
Warning:Use only one of the following batteries: Tadiran
TLH-5930/S, Tadiran TL-5930/S, Tadiran SL-2780, or Xeno
Energy XL-205F.
Life Up to five years depending on the operating mode and
configuration.
Hazardous area
temperature range
(Ta)
Battery models Temperature range
TLH-5930/S-40 °C < Ta < 80 °C
Operating
conditions
Operating
temperature
TL-5930/S, Xeno XL-205F, Tadiran
-40 °C < Ta < 70 °C
SL-2780
-40 °C to 85 °C (-40 °F to 185 °F)(Operating at extreme
temperatures or beyond negatively affects battery life and
may damage the sensor.)
7/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
FeatureCharacteristicValue
Vibration limit 20 g peak
Chemical resistance
Stainless steel and high temperature, solvent- and UV-
resistant PPS plastic.
Shock resistance 0.5 meter drop onto concrete
AltitudeMaximum 3,000 m (9,842 ft.) outdoors
Physical Weight 230 grams (without battery; 300 grams with battery)
Dimensions Height: 88 mm; diameter: 40 mm
Case material 316 stainless steel body and glass-reinforced, impact-
resistant PPS top
Mounting hole M6 x 1mm X 5mm deep internal thread
IP rating IP67 dust and water resistant
Regulatory
compliance
EMC conformity
standards
IEC 61326-1, ETSI EN 301 489-1, CISPR22, ETSI EN 301 489-17
Radio spectrum ETSI EN 300 328
Safety ETSI EN 61010-1, IEC 62479
Hazardous
Atmosphere
CSA Class 1 Division 1 Groups A, B, C, D T4
ATEX/IECEx Zone 0
Conformity Compliant with all CE and FCC/IC requirements
ISA100a
Valid forRangerPro
BN P/N
Yokogawa YFGW 410 Field Wireless Management Station
121M6466, 121M6469, 121M6470
147M7136-02-01 (pending)
compatible
gateways
YFGW 510 Field Wireless Access Points
Honeywell WDM Wireless Device Manager R310.2-4 or newer
FDAP Field Device Access Point
WirelessHART
Emerson 14101410 (compatible with firmware version 4.7.84 or newer)
compatible
gateways.
†
Emerson 14201420 (compatible with firmware version 4.7.84 or newer)
HoneywellHoneywell WDMR310.2-4 or newer (pending)
†
Generic Client Interface (GCI) or HARTIP required. Order when new or license as necessary.
Advanced Features
Data on DemandModeUser-initiated. Acquisition initiated from Ranger Pro
Configuration Software.
8/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
FeatureCharacteristicValue
StatusIdle, Requested or Busy
Data on VibrationThreshold User settings. Range: 0 to 0.1 in/s rms
ModeEnabled/Disabled
DetectionXYZ vector sum or Z axis only
StatusOn or Off
Data on SeverityModeEnabled/Disabled
TA Proven Method
User settings. Range: 0.05 to 2.5 in/s rms
Level 3
TA Proven Method
User settings. Range: 0.05 to 2.5 in/s rms
Level 4
DetectionXYZ vector sum or Z axis only
StatusGreen, Yellow or Red when enabled
9/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Accessories
The installation kit (130M5452)includes a battery installation tool, two installation wrenches, spare Orings, and USB docking station. These parts can also be ordered individually.
Product or
Document
138M0302 Ranger Pro e-module retaining ring and O-ring kit
121M7993Battery installation tool
121M7994C-spanner wrench, for Ranger Pro Wireless Condition
Monitoring sensor and M6x1 to ¼-28 and M6x1 to 3/8-24 25
tri-axial alignment stud
121M7995Wrench, for M6x1 to M8x1.25 tri-axial alignment stud
Ranger Pro Wireless Condition Monitoring configuration software (available for
download from BN Technical Supoort)
Ranger Pro Wireless Condition Monitoring User Guide
Ranger Pro Wireless Condition Monitoring Quick Start Guide
10/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Spare Mounting Adapters
Illustrations shown are not to scale. All mounting adapters are made from 316 stainless steel.
Part
Number
Standard Studs
121M7987M6x1 to M6x1
121M7988M6x1 to 1/4-
121M7989M6x1 to
121M7990
125M3920
SizeIllustration
stud
28 adapter
stud
M8x1.25
adapter
stud
M6x1 to 10-32
adapter
stud
M6x1 to 3/824 adapter
stud
Universal Magnetic Mounting Adapter
02200371
Cementing Pads and Adhesive
121M7991M6x1 epoxy
167236-01 3.5 g Click Bond CB200 acrylic adhesive for use with epoxy cementing pads. Sufficient for
Tri-axial Alignment Studs
121M7986M6x1.0 to
1.85” Ø x 1.09” H (47 x 27.7 mm), 100 lbf (45kg) pull, 2-pole, ¼-28 female UNF thread. Requires
mounting option A04.
cementing
pad
about four pads.
M8x1.25
11/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Part
Number
SizeIllustration
125M3921M6x1 to ¼-28
125M3922 M6x1 to 3/8-
24
143M5507 M6x1 epoxy
mount
alignment
stud
Expect a decrease in XY accuracy when using friction alignment studs.
12/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
A: Mounting Hardware Options
Ordering Information
For the detailed listing of country and
product specific approvals, refer to the
Approvals Quick Reference Guide
(108M1756) available from Bently.com.
Ranger Pro Tri-Axial Sensor ISA100
70M303 – AA-BB-CC-DD
Description: Tri-axial wireless accelerometer
and integral temperature sensor.
Ranger Pro Single Axis Sensor
ISA100
70M301 – AA-BB-CC-DD
Description: Uniaxial wireless accelerometer
and integral temperature sensor.
Ranger Pro Repeater ISA100
70M300 – AA-BB-CC-DD
Description: Wireless repeater.
Ranger Pro Tri-axial Sensor
WirelessHART
03M6x1 to M6x1 Stud
04M6x1 to ¼-28 Adapter Stud
05
06M6x1 to 3/8-24 Adapter Stud
07
08
09M6x1 Epoxy Cementing Pad
10Cementing tri-axial stud
B: Radio Option
01
C: Battery Option
00
01
D: Agency Approval Option
01
02
M6x1 to 10-32 Adapter Stud
M6x1 to ¼-28 tri-axial Alignment Stud
M6x1 to 3/8-24 tri-axial Alignment Stud
ISA100 or WirelessHART
No battery
Battery supplied, not installed
CSANorth America
ATEX/IECEx
Ranger Pro Installation Kit
130M5452 – AA
70M403 – AA-BB-CC-DD
Description: Tri-axial wireless accelerometer
and integral temperature sensor.
Ranger Pro versions 70M303, 70M301,
70M300, 70M403 use the same ordering
information.
A: Mounting Hardware Options
00
01M6x1 to M8x1.25 Tri-axial Alignment Stud
02
No Stud
M6x1 to M8x1.25 Adapter Stud
Description: Installation kit including battery
installation tool, O-rings, wrenches, and
USBreaders.
A: Installation Package
00
01 Installation Tools and USB Reader
02 USBReader only
13/18
Installation Tools
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
System 1 Ranger Pro Device License
3071/13 – AA-BB-CC
Description: System 1 device license for Ranger
Pro sensors installed for use with System 1. One
device license is required per Ranger Pro sensor.
A: Not Applicable for Ranger Pro
00
B: Not Applicable for Ranger Pro
00
C: Ranger Pro Device
00
## Number of licenses required
Option 3071/13 is only applicable to
Ranger Pro devices that are installed for
use with System 1. To order System 1, see
System 1 Software Package Datasheet
(document 108M5214). The AA option is
only for vbOnline Pro device licenses. The
BBoption is only for 2300 monitor device
licenses.
14/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Catalog
Order
Number
Part NumberFigure
(1)
70M303-XX-
01-XX-XX
70M301-XX-
01-XX-XX
121M6469
Figure 1: Ranger Pro Wireless Condition Monitoring 70M303 Sensor
Front/Rear Views
121M6466
70M300-XX-
01-XX-XX
Figure 2: Ranger Pro Wireless Condition Monitoring 70M301 Sensor
Front/Rear Views
121M6470
Figure 3: Ranger Pro Wireless Condition Monitoring 70M300
Repeater Front/Rear Views
15/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Catalog
Order
Number
Part NumberFigure
(1)
70M403-XX-
147M7136-02-
01-XX-XX
(1)
Customer order number
01
Figure 4: Ranger Pro Wireless Condition Monitoring 70M403
Front/Rear Views
16/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
eDrawings and Figures
Dimensions are given in inches [millimeters] unless noted otherwise.
Figure 1: Ranger Pro Wireless Condition Monitoring 70M303 sensor
(Identical specifications for the 70M300, 70M301, 70M403)
17/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Copyright 2020 Baker Hughes Company. All rights reserved.
Bently Nevada, System 1, Ranger and Orbit Logo are registered trademarks of Bently Nevada, a Baker Hughes
Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes
Company. All other product and company names are trademarks of their respective holders. Use of the trademarks
does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does
not make any representation as to the accuracy or completeness of the information and makes no warranties of
any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and
fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of BakerHughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com
18/18