The Ranger Pro Wireless Condition Monitoring vibration
sensor allows you to monitor velocity, acceleration, and
temperature plus timebase waveforms, spectra, and
PeakDemod spectrum. It's built for plant managers and
operators in power generation, oil and gas, and related
industrial markets.
The Bently Nevada Ranger Pro Wireless Condition Monitoring
sensor enables you to:
l Monitor and optimize the reliability of low- and
medium-criticality machines.
l Establish or expand existing reliability programs.
l Make maintenance decisions based on current data.
l Reduce maintenance costs.
l Decrease unplanned machine failures.
l Increase machinery life.
125M5237 Rev. H
Ranger Pro Wireless Condition Monitoring is a simple, easy to
implement solution for use in hazardous or difficult to access
environments where wired solutions are impractical.
Use the Ranger Pro Wireless Condition Monitoring to get
immediate notifications, short- and long-term trending data,
and diagnostic reporting. No more "reporting by walking
around."
Quickly publish overall data through Modbus to third-party
tools or spectra and waveform data through Generic Client or
Hart IPInterface to Bently Nevada System 1 software.
Configure Ranger Pro devices over-the-air using third-party
tools or the Ranger Pro Configuration software.
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
System 1Support
Machinery Applications
Ranger Pro Wireless Condition Monitoring is a
vibration sensor for machines with rollerelement bearings including:
l Agitators
l Air compressors
l Ball mills
l Blowers
l Centrifuges
l Cooling tower fans and pumps
l Motors
l Small reciprocating compressors
l Small hydro and steam turbines
Hardware Features
You can configure Ranger Pro Wireless
Condition Monitoring to work in a variety of
environments and applications.
l Uniaxial and tri-axial capable velocity and
acceleration detection.
l Environment temperature reporting.
l Mounting hardware options to fit most
battery.
l IP67 dust and water resistant.
l Embedded sensors connect using the
ISA100 wireless or WirelessHART network
protocols.
l Can act as a router for other Ranger Pro
sensors.
After installing Ranger Pro devices, you can set
a start time for multiple devices to begin data
acquisition using Ranger Pro Configuration
Software.
Ranger Pro collects overall vibration,
temperature measurements, timebase
waveforms, spectra, and Peak Demod
spectrum using Generic Client Interface (GCI)
for ISA100 Ranger Pro devices and HARTIPfor
WirelessHARTRanger Pro devices with System 1
software. You can filter overall and dynamic
timebase and spectra data.
Network Installation
A typical network installation uses several
Ranger Pro Wireless Condition Monitoring
sensors, Ranger Pro repeaters, wireless device
managers, and access points. Ranger Pro is
available in either uniaxial or tri-axial vibration
detection.
You can use third-party tools or the Ranger Pro
Configuration software to quickly provision and
configure Ranger Pro devices over-the-air.
Wireless range varies depending on
environmental obstacles, gateway antenna
type, and the orientation of the sensor relative
to the gateway antenna.
2/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Hazardous Area Approvals
WARNING
HAZARDOUS
ENVIRONMENT
Risk of explosive atmosphere.
DO NOT OPEN WHEN AN
EXPLOSIVE ATMOSPHERE IS
PRESENT. POTENTIAL
ELECTROSTATIC CHARGING
HAZARD. The equipment shall
only be cleaned with a damp
cloth when deployed in a
hazardous area.
Compliance and Certifications
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any interference
received, including interference that may
cause undesired operation.
CSA
Class I, Division 1 Groups A, B, C, D
ATEX/IECEx Standards
Ex ia IIC T4 Ga
Ex ia IMa
RoHSDirectives
2011/65/EU
3/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
Specifications
FeatureCharacteristicValue
AccelerometersAxis1 or 3 axis (ISA100)
3 axis only (WirelessHART)
Sensing element Piezoelectric ceramic
Amplitude range ±20 g peak
Measurement
accuracy
Transverse
sensitivity (Typ.)
±5% (160 Hz) Z-axis
±10% (160 Hz) X and Y axis
7%
4/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
FeatureCharacteristicValue
Trending Variables
Acceleration
Acceleration
frequency range
Z axis: 5 Hz (±3dB) to 10 kHz (±3dB)
X and Y axis: 5 Hz (±3dB) to 4 kHz (±3dB) (tri-axial sensor
only)
Acceleration
0 – 200 m/s2 (0 - 20 g)
amplitude range
Acceleration units /
g or m/s2 / peak or rms
subunits
Fmin 2, 5, 10, 100, 200 (Hz)
Fmax
200, 500, 1000, 2000, 5000, 10000‡Hz
‡ 10,000 only on Z-axis
Velocity
Velocity frequency
5 – 2000Hz
range
Velocity amplitude
0 – 50 mm/s (0 - 2 in/s)
range
Velocity units /
in/s or mm/s peak or rms
subunits
Fmin 5, 10Hz
Fmax 200, 500, 1000, 2000Hz
Peak Demod
Peak Demod PkZ axis only
Parameters based on PeakDemod Spectrum settings
below
Measurement
6, 8, 12, 24, 48, 168, 336, 672 hours
interval
Output data Overall values using:
l Modbus from device gateway
l Generic Client Interface (GCI) for ISA100 devices
l HARTIPfor WirelessHART
5/18
Ranger Pro Wireless Condition Monitoring
Datasheet125M5237 Rev. H
FeatureCharacteristicValue
Waveforms and
Spectra
Acceleration
Acceleration
X, Y and Z axis depending on sensor model
waveform
Fmin 2, 5, 10Hz
Fmax 200, 500, 1000, 2000, 5000, 10000 ‡ Hz
‡ Z-axis only
Number of samples 1024, 2048, 4096, 8192
Units/subunits g or m/s2 / peak
Velocity
Velocity spectra X, Y and Z axis depending on sensor model
Fmin 5, 10
Fmax 200, 500, 1000, 2000
Number of lines 400, 800, 1600, 3200
Units/subunits in/s or mm/s / rms
Peak Demod
Temperature
sensor
Peak Demod
Z-Axis only
spectrum
Fmax 200, 500, 1000, 2000, 5000Hz
Demod Band Min 500, 1000, 2000, 5000Hz Max 40000 Hz