Bently Nevada Ranger Pro Data sheet

Ranger Pro Wireless Condition Monitoring
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

The Ranger Pro Wireless Condition Monitoring vibration sensor allows you to monitor velocity, acceleration, and temperature plus timebase waveforms, spectra, and PeakDemod spectrum. It's built for plant managers and operators in power generation, oil and gas, and related industrial markets.
The Bently Nevada Ranger Pro Wireless Condition Monitoring sensor enables you to:
l Monitor and optimize the reliability of low- and
medium-criticality machines. l Establish or expand existing reliability programs. l Make maintenance decisions based on current data. l Reduce maintenance costs. l Decrease unplanned machine failures. l Increase machinery life.
125M5237 Rev. H
Ranger Pro Wireless Condition Monitoring is a simple, easy to implement solution for use in hazardous or difficult to access environments where wired solutions are impractical.
Use the Ranger Pro Wireless Condition Monitoring to get immediate notifications, short- and long-term trending data, and diagnostic reporting. No more "reporting by walking around."
Quickly publish overall data through Modbus to third-party tools or spectra and waveform data through Generic Client or Hart IPInterface to Bently Nevada System 1 software. Configure Ranger Pro devices over-the-air using third-party tools or the Ranger Pro Configuration software.
Ranger Pro Wireless Condition Monitoring Datasheet 125M5237 Rev. H
System 1Support

Machinery Applications

Ranger Pro Wireless Condition Monitoring is a vibration sensor for machines with roller­element bearings including:
l Agitators l Air compressors l Ball mills l Blowers l Centrifuges l Cooling tower fans and pumps l Motors l Small reciprocating compressors l Small hydro and steam turbines
Hardware Features
You can configure Ranger Pro Wireless Condition Monitoring to work in a variety of environments and applications.
l Uniaxial and tri-axial capable velocity and
acceleration detection. l Environment temperature reporting. l Mounting hardware options to fit most
applications. l Replaceable lithium-thionyl chloride
battery. l IP67 dust and water resistant. l Embedded sensors connect using the
ISA100 wireless or WirelessHART network
protocols. l Can act as a router for other Ranger Pro
sensors.
After installing Ranger Pro devices, you can set a start time for multiple devices to begin data acquisition using Ranger Pro Configuration Software.
Ranger Pro collects overall vibration, temperature measurements, timebase waveforms, spectra, and Peak Demod spectrum using Generic Client Interface (GCI) for ISA100 Ranger Pro devices and HARTIPfor WirelessHARTRanger Pro devices with System 1 software. You can filter overall and dynamic timebase and spectra data.
Network Installation
A typical network installation uses several Ranger Pro Wireless Condition Monitoring sensors, Ranger Pro repeaters, wireless device managers, and access points. Ranger Pro is available in either uniaxial or tri-axial vibration detection.
You can use third-party tools or the Ranger Pro Configuration software to quickly provision and configure Ranger Pro devices over-the-air.
Wireless range varies depending on environmental obstacles, gateway antenna type, and the orientation of the sensor relative to the gateway antenna.
2/18
Ranger Pro Wireless Condition Monitoring Datasheet 125M5237 Rev. H
Hazardous Area Approvals
WARNING
HAZARDOUS ENVIRONMENT
Risk of explosive atmosphere.
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. POTENTIAL ELECTROSTATIC CHARGING HAZARD. The equipment shall only be cleaned with a damp cloth when deployed in a hazardous area.
Compliance and Certifications
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any interference
received, including interference that may
cause undesired operation.
CSA
Class I, Division 1 Groups A, B, C, D
ATEX/IECEx Standards
Ex ia IIC T4 Ga Ex ia IMa
RoHS Directives
2011/65/EU
3/18
Ranger Pro Wireless Condition Monitoring Datasheet 125M5237 Rev. H

Specifications

Feature Characteristic Value
Accelerometers Axis 1 or 3 axis (ISA100)
3 axis only (WirelessHART)
Sensing element Piezoelectric ceramic
Amplitude range ±20 g peak
Measurement accuracy
Transverse sensitivity (Typ.)
±5% (160 Hz) Z-axis ±10% (160 Hz) X and Y axis
7%
4/18
Ranger Pro Wireless Condition Monitoring Datasheet 125M5237 Rev. H
Feature Characteristic Value
Trending Variables
Acceleration
Acceleration frequency range
Z axis: 5 Hz (±3dB) to 10 kHz (±3dB) X and Y axis: 5 Hz (±3dB) to 4 kHz (±3dB) (tri-axial sensor only)
Acceleration
0 – 200 m/s2 (0 - 20 g)
amplitude range
Acceleration units /
g or m/s2 / peak or rms
subunits
Fmin 2, 5, 10, 100, 200 (Hz)
Fmax
200, 500, 1000, 2000, 5000, 10000‡Hz ‡ 10,000 only on Z-axis
Velocity
Velocity frequency
5 – 2000Hz
range
Velocity amplitude
0 – 50 mm/s (0 - 2 in/s)
range
Velocity units /
in/s or mm/s peak or rms
subunits
Fmin  5, 10Hz
Fmax 200, 500, 1000, 2000Hz 
Peak Demod
Peak Demod Pk Z axis only
Parameters based on PeakDemod Spectrum settings below
Measurement
6, 8, 12, 24, 48, 168, 336, 672 hours
interval Output data Overall values using:
l Modbus from device gateway l Generic Client Interface (GCI) for ISA100 devices l HARTIPfor WirelessHART
5/18
Ranger Pro Wireless Condition Monitoring Datasheet 125M5237 Rev. H
Feature Characteristic Value
Waveforms and Spectra
Acceleration
Acceleration
X, Y and Z axis depending on sensor model
waveform
Fmin 2, 5, 10Hz
Fmax 200, 500, 1000, 2000, 5000, 10000 ‡ Hz
‡ Z-axis only
Number of samples 1024, 2048, 4096, 8192
Units/subunits g or m/s2 / peak
Velocity
Velocity spectra X, Y and Z axis depending on sensor model
Fmin 5, 10
Fmax 200, 500, 1000, 2000
Number of lines 400, 800, 1600, 3200
Units/subunits in/s or mm/s / rms
Peak Demod
Temperature sensor
Peak Demod
Z-Axis only
spectrum
Fmax 200, 500, 1000, 2000, 5000Hz
Demod Band Min 500, 1000, 2000, 5000Hz Max 40000 Hz
Units/subunits g, m/s2 / peak
Waveforms and
6, 8, 12, 24, 48, 168, 336, 672hours spectra measurement intervals
Output data
Waveforms and spectra via:
l Generic Client Interface (GCI) for ISA100 l HARTIPfor WirelessHART
Measurement range
-40 °C to 120 °C (-40 °F to 248 °F) (Temperature sensor
range. Not to be confused with allowable operating
temperatures. Limited by battery and ambient
conditions.) Resolution 0.1 °C (°F)