Beckett CL201UL, CL202UL, CL202ULHT, CL202CE Installation Manual

CAUTION
INSTALLATION
Save this Manual for
Models /
/
Modèles
All Beckett pumps are warranted to the user against defective material and workmanship under normal use, for a period of 1 year from the date of purchase by the original purchaser. All other Beckett products are warranted to the user against defective material and workmanship for 3 months from the date of purchase. Replacement liability in all events is limited to the replacing or repairing at Beckett’s sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc. APPLICATION: Warranty covers only properly installed and maintained units. Warranty is limited to applications pumping fresh water at temperatures of 32°-86°F (0°-30°C), with a pH range of 5 to 9. Beckett Corporation must approve other liquid applications and extreme temperature uses in advance in writing. ADMINISTRATION: Warranty claims must be made by returning the defective part, freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer Care Dept., Irving, TX. Phone authorization is required prior to returning merchandise (888-232-5388). All items returned will be inspected to determine cause of failure before warranty is approved. INSTALLATION and/or REMOVAL CHARGES: Warranty does not cover any costs associated with the installation or removal of products subject to warranty claims. DISPOSITION: Beckett will make a good-faith effort for prompt disposition regarding any item in warranty, which proves to be defective. If products were damaged in transit, please file a claim with the carrier. DISCLAIMER: Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. Seller's and manufacturer's only obligation and buyer's and user's only remedy, shall be for the manufacturer to either replace and/or repair at the manufacturer's sole discretion the Beckett product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assumes all risk and liability whatsoever in connection herewith. The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy. IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This Warranty gives buyer and user specific legal rights, and buyer and user may also have other rights that vary from state to state. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
Todas las bombas de Beckett están cubiertas por una garantía al usuario contra defectos de materiales y fabricación durante doce (12) meses a partir de la fecha de compra, siempre y cuando se le haya dado uso normal. Todos los demás productos de Beckett están cubiertos por una garantía al usuario contra defectos de materiales y manufactura durante tres (3) meses a partir de la fecha de compra. En estos casos, la responsabilidad de reemplazo se limita a la sustitución y / o reparación a discreción exclusiva de Beckett de la(s) pieza(s), que tengan defectos de materiales o manufactura. Para efectuar reclamos se requiere una pruebe de la adquisición, tal como la factura o en su defecto la nota de entrega. APLICACIÓN: la garantía sólo cubre las unidades instaladas y mantenidas correctamente. La garantía se limita al bombeo de agua fresca en temperaturas de 32° F a 86° F (0° C a 30° C) y con una escala de pH de 5 a 9. La Corporación Beckett debe aprobar por escrito el uso de otros líquidos y la operación bajo temperaturas extremas. ADMINISTRACIÓN: Los reclamos de garantía deben hacerse devolviendo la pieza defectuosa al fabricante con el flete prepagado por el comprador y / o usuario, junto con la pruebe de compra a: Beckett Corporation, Customer Care Dept., Irving, TX. Para esta devolución se requiere la previa autorización telefónica a través del número 888-232-5388. Todos los artículos que sean devueltos por el comprador o el usuario serán inspeccionado para determinar la causa de la falla antes de que el fabricante acepte la responsabilidad a que haya lugar. CARGOS POR INSTALACIÓN Y / O RETIRO: La garantía no cubre costos asociados con la instalación o el retiro de producto sujeto a reclamos de garantía. DISPOSICIÓN: La Corporación Beckett hará esfuerzo en buena fe de solucionar prontamente su reclamo por los artículos bajo garantía que resulten defectuosos. Si los productos fueron dañados en tránsito, debe presentar su reclamo a la compañía transportadora. LIMITACIÓN DE RESPONSABILIDAD: El usuario no debe confiar en declaraciones verbales sobre el producto hechas por el vendedor, el fabricante o por cualquier otra persona, porque éstos no constituyen garantías ni forman parte del contrato de venta. La única obligación del fabricante con respecto al comprador y / o usuario es reemplazar y / o reparar el producto Beckett, a su exclusiva discreción, como se ha indicado anteriormente. Ni el vendedor ni el fabricante serán responsables de ninguna lesión, perdida o daño, directo, incidental o consecuente (incluyendo, pero no limitado a daños incidentales o consecuentes por pérdidas de ganancias, ventas, daños personales o daños a propiedades o cualquier otra pérdida incidental o consecuente) que se deban a cualquier causa, tanto si se basan en garantías como en contratos, negligencias u otras malas aplicaciones, y el comprador y / o usuario aceptan que no tendrán a su disposición ningún otro recurso. Antes de utilizarlo, el comprador y / o usuario deberán determinar si el producto es adecuado para la aplicación a la que vaya a destinarse y asumen todos los riesgos y las responsabilidades relacionadas con sus utilizaciones. La garantía y los recursos escritos en este parágrafo se consideran obligaciones exclusivas y en lugar de cualquier otra garantía expresa o implícita. Se excluyen de modo expreso todas las otras garantías incluyendo sin limitación cualquier garantía implícita de COMERCIALIDAD O CONVENIENCIA PARA CUALQUIER PARTICULAR. Esta garantía da al adquiriente y / o al usuario derechos legales específicos y ambos pueden tener también otros derechos que varían de un estado a otro. Algunos no permiten la exclusión o limitación de los daños y perjuicios incidentales o consecuentes, por lo tanto puede ser que la anterior limitación de la responsabilidad no sea aplicable en su caso.
Toutes les pompes de Beckett sont garanties à l'utilisateur contre tout défaut de matière ou vice de fabrication en condition normale d’utilisation durant une période de 1 an à compter de la date d'achat par l'acheteur initial. Tous les autres produits de Beckett sont garantis à l’utilisateur contre tout défaut de matière ou vice de fabrication pour une période de trois mois à compter de la date d’achat. Peu importe les circonstances, l’obligation de remplacement se limite au remplacement ou à la réparation, laissés à l’entière discrétion de Beckett, de toute pièce présentant un défaut de matière ou un vice de fabrication. Pour toute réclamation, une preuve d'achat est exigée, qu’il s’agisse d’une facture, d’un coupon de caisse, etc. PORTÉE DE LA GARANTIE : La garantie couvre uniquement les pompes qui auront été correctement installées et entretenues. La garantie ne couvre que les pompes ayant servi au pompage de l'eau d’une température allant de 0 °C à 30 °C (32 °F à 86 °F), dont le pH se situe entre 5 et 9. Avant d’utiliser la pompe pour pomper d'autres liquides ou des liquides à des températures élevées, il faut recevoir au préalable l'autorisation écrite de Beckett Corporation ADMINISTRATION : Pour faire valoir la garantie, retourner le produit défectueux, port payé, accompagné de la preuve d'achat à l'adresse suivante : Beckett Corporation, Customer Care Dept., Irving, TX. Avant de retourner un article, une autorisation doit être obtenue au téléphone (888-232-5388). Tous les articles retournés seront vérifiés afin de déterminer la cause de la défectuosité et de vérifier s’ils sont couverts par la garantie. FRAIS D'INSTALLATION ou d’ENLÈVEMENT : La garantie ne couvre pas les frais reliés à l'installation ou à l’enlèvement des articles faisant l'objet d'une réclamation dans le cadre de la garantie. RÈGLEMENT : Beckett agira de bonne foi pour remplacer ou réparer rapidement tout article couvert par la garantie qui aura été jugé défectueux. Si un article est endommagé durant l’expédition, veuillez présenter une réclamation auprès du transporteur. EXCLUSION DE RESPONSABILITÉ : Toute déclaration orale émise par le vendeur, le fabricant, les représentants ou par toute autre partie ne fait aucunement partie de la présente garantie, ni du contrat de vente et ne peut être invoqué par l’utilisateur. En cas de défectuosité, les obligations du vendeur ou du fabricant et les droits de l’utilisateur se limiteront au remplacement ou à la réparation de l’article, et ce, à la seule discrétion du fabricant du produit, Beckett, tel que stipulé plus haut. Ni le vendeur ni le fabriquant ne peut être tenu responsables des blessures, pertes ou dommages, que ces derniers soient directs, indirects ou consécutifs (y compris, mais sans limiter la portée générale de ce qui suit, les dommages entraînés par la perte de profits, la perte de ventes, les blessures ou les dégâts matériels ou toute autre perte indirecte ou consécutive) quelle que soit la cause, que cette dernière découle de la garantie, du contrat, d’une négligence ou d’une utilisation abusive, l'acheteur et l'utilisateur reconnaissent qu’ils ne disposent d'aucun recours. Avant d'utiliser le produit, l'acheteur et l'utilisateur doivent déterminer si le produit convient à l'usage qu'ils prévoient en faire et assumer tous les risques et responsabilités en découlant. La garantie et le recours décrits dans la présente représentent la seule et unique garantie et REMPLACENT toute autre garantie ou recours, exprès ou implicites, qui sont EXCLUS en vertu des présentes, y compris, sans limitation, toute garantie implicite quant à la QUALITÉ MARCHANDE ET AU CARACTÈRE ADÉQUAT POUR UN USAGE PARTICULIER du produit. Cette garantie donne à l'acheteur et à l'utilisateur des droits spécifiques, cependant l'acheteur et l'utilisateur peuvent bénéficier de droits qui varient selon les états ou les provinces. Certains états ou provinces ne permettent pas d’exclure ou de limiter la responsabilité dans le cas de dommages indirects ou consécutifs, il est donc possible que les restrictions ou exclusions de la présente ne vous concernent pas.
BECKETT CORPORATION
3321 E. Princess Ann Rd. Norfolk, Va. 23502 www.beckettpumps.com Toll Free: 1-888-232-5388 © 2010 BECKETT CORPORATION All Rights Reserved
LIMITED WARRANTY
GARANTIA LIMITADA
GARANTIE LIMITEE
AUTOMATIC CONDENSATE REMOVAL PUMP
BOMBA AUTOMATICA PARA REMOVER CONDENSACION
POMPE DE RETRAIT DE CONDENSATS AUTOMATIQUE
Read all Instructions carefully for safe operation and installation. Do not handle the pump with wet hands or when standing in water as fatal shock could occur. Disconnect main power before handling unit for any reason!
PRECAUCIÓN
Lea todas las instrucciones cuidadosamente para operar e instalar la bomba en forma segura. No manipule la bomba con las manos húmedas o si está parado en una superficie con agua, ya que puede producirse una descarga mortal. ¡Desconecte la alimentación principal antes de manipular la unidad por cualquier motivo!
MISE EN GARDE
Lire attentivement toutes les instructions pour une installation et un fonctionnement sans danger. Ne pas manipuler la pompe avec les mains humides ou debout dans l'eau car cela pourrait mener à un choc mortel. Couper le courant avant de manipuler l'unité pour quelque raison que ce soit !
Modelos
CL201UL CL202UL
CL202ULHT
CL202CE
1)
Select a location for the pump. It should be as near as possible to the air conditioning coil. THE PUMP MUST BE LEVEL. The inlet hole must be below the coil drain.
2)
Carefully unpack the pump. Remove the cover assembly from the tank; check float assembly for free movement.
3)
Run a drain line from the evaporator coil drain to the pump inlet. Be sure inlet piping is sloped downward to allow gravity flow. Insert the line below the tank cover and be sure it does not interfere with the operation of the float.
4)
Connect outlet tubing to discharge of pump. Do not run tubing vertical more than 17’ for each unit. For good flow, slant the horizontal run downward.
INSTALACIÓN
1)
Elija una ubicación para la bomba. Debe estar lo más cerca posible del serpentín del aire acondicionado. LA BOMBA DEBE APOYAR SOBRE UNA SUPERFICIE NIVELADA. El orificio de entrada debe estar debajo del drenaje del serpentín.
2)
Saque la bomba de la caja con cuidado. Quite el conjunto de la cubierta del tanque; verifique que el conjunto del flotador se mueva libremente.
3)
Instale una línea de drenaje desde el drenaje del serpentín del evaporador hasta la entrada de la bomba. Asegúrese de que la tubería de entrada tenga pendiente hacia abajo para que el desagüe se realice por gravedad. Introduzca la línea debajo de la cubierta del tanque y asegúrese de que no interfiera con el funcionamiento del flotador.
4)
Conecte la tubería de salida para descargar la bomba. No instale la tubería en forma vertical más de 5.0m recomendada para cada unidad. Para lograr un buen desagüe, incline la tubería horizontal hacia abajo.
INSTALLATION
1)
Choisir un endroit pour la pompe qui devrait être aussi près que possible du serpentin du climatiseur. LA POMPE DOIT ÊTRE À NIVEAU. Le trou d'entrée doit être sous le serpentin.
2)
Déballer la pompe avec soin. Retirer l'assemblage de couvercle du réservoir; vérifier l'assemblage du flotteur pour s'assurer qu'il se déplace librement.
3)
Acheminer un conduit de vidange du drain du serpentin d'évaporateur à l'entrée de la pompe. S'assurer que le tuyau d'entrée soit en pente vers le bas pour permettre un écoulement gravité. Insérer le conduit sous le couvercle du réservoir et faire en sorte de ne pas entraver le mouvement du flotteur.
4)
Connecter le tuyau de sortie au refoulement de la pompe. Ne pas acheminer le tuyau verticalement pendant plus de 5.0m recommandé pour chaque unité. Pour un bon écoulement, pencher l'acheminement horizontal vers le bas
future reference.
Conserve este Manual
para usarlo como
referencia en el futuro.
Conserver ce manuel
à titre de référence.
.
Z8316 Rev. B
WIRING
WARNING
WARNING
PIPING
elevado.
Blue /
Azul
/
Bleu
Thermostat /
T
ermostato /
Thermostat
Blue /
Azul
/
Bleu
Relay / Transformer or Low Voltage
Terminal Board
Green /
Verde
/
Vert
White /
Blanco
/ Blanc
Whi
te /
Blanco
/ Blanc
TUYAUTERIE
Also refer to your Furnace Manufacture Instructions.
Run a drain line from the evaporator coil drain and furnace to the pump.
Use flexible plastic pipe, where the code permits, and insert the pipe ¾” below the pump cover. When multiple drains (main and overflow) are required it may be necessary to tee them together where they enter the pump.
CAUTION:
condensate drain from the furnace.
Locate the highest point above the pump, but no more than 17 feet, and fasten flexible tubing or 3/8” I.D. maximum pipe to the discharge to prevent excessive back flow to the unit.
Be careful not to kink it, for this will block the flow.
From this high point, slope discharge line down slightly to a point above the drain area; then turn down and extend to a point below or approximately level with the bottom of the condensate unit. If it is impossible to slope discharge line down, make an inverted “U” trap directly above the pump at the highest point.
Couple the vinyl tubing with a 3” piece of 3/8” O.D. copper tubing. Or you can use 3/8” copper tubing all the way to the drain.
This pump does not require use of a condensate neutralizer to protect the pump when used with a condensing gas furnace. However, local codes may require that it be used.
Consulte también las Instrucciones del fabricante de calderas.
Instale una línea de drenaje desde el drenaje del serpentín del evaporador y la caldera hasta la entrada de la bomba.
Use tubos de plástico flexible, cuando el código lo permita, e introduzca el tubo ¾” por debajo de la cubierta de la bomba. Cuando se requieran varios drenajes (principal y de sobre flujo), posiblemente sea necesario conectarlos en "T" en el lugar donde se introducen en la bomba.
PRECAUCIÓN:
evaporador junto con un drenaje de condensado de la caldera.
Localice el punto más elevado sobre la bomba, que no esté a más de 17 pies (5.0 m), y fije el tubo flexible o el tubo de 3/8” de diámetro interno como máximo al desagüe para evitar que haya un exceso de reflujo a la unidad.
Trate de que no quede estrangulado, ya que bloqueará el flujo.
Desde este punto elevado, incline la línea de desagüe ligeramente hacia abajo hasta un punto por encima del área de drenaje; luego dóblela hacia abajo y extiéndala hasta un punto que esté por debajo o aproximadamente al mismo nivel de la parte inferior de la unidad de condensación. Si es imposible inclinar la línea de desagüe hacia abajo, haga una trampa en “U” invertida directamente por encima de la bomba en el punto más
Una el tubo de vinilo con un trozo de 3” de tubo de cobre de 3/8” de diámetro externo. Puede usar tubo de cobre de 3/8” en todo el recorrido hasta el drenaje.
Esta bomba no requiere el uso de un neutralizador de condensado para protegerla cuando se usa con una caldera de gas de condensación. Sin embargo, es posible que los códigos locales exijan usarlo.
Se reporter aussi aux instructions du fabricant de la chaudière.
Acheminer un conduit de vidange du drain du serpentin d'évaporateur et de la chaudière à la pompe.
Utiliser un tuyau de plastique flexible si le code le permet et insérer le tuyau ¾ pouce sous le couvercle de la pompe. Lorsqu'il faut plusieurs drains (principal et de déversement), il faudra peut-être les raccorder ensemble en té à l'endroit où ils entrent dans la pompe.
MISE EN GARDE :
Trouver le point le plus élevé au-dessus de la pompe, mais pas plus de 17 pieds de hauteur et fixer le tuyau flexible ou un tuyau de 3/8 pouce de D.I. maximum au refoulement pour éviter tout reflux excessif à l'unité.
Attention de ne pas tortiller le tuyau car cela pourrait bloquer l'écoulement.
À partir de ce point, incliner le conduit de refoulement un peu vers le bas jusqu'à un point au-dessus du secteur de vidange; tourner ensuite vers le bas et prolonger le tout jusqu'à un point en-dessous ou presque à niveau avec le bas de l'unité de condensats. S'il est impossible d'orienter le conduit vers le bas, faire un siphon en "U" inversé directement au-dessus de la pompe à l'endroit le plus élevé.
Coupler le tuyau de vinyle avec une longueur de tuyau de cuivre de 3 pouce et de D.E. de 3/8 pouce On peut aussi utiliser un tuyau de cuivre de 3/8 pouce jusqu'au drain.
Cette pompe n'a pas besoin de neutralisant de condensats pour protéger la pompe utilisé avec une chaudière à gaz à condensation. Certains codes peuvent toutefois exiger leur utilisation.
Do not tee an evaporator coil drain together with a
TUBERÍA
No conecte en "T" un drenaje del serpentín del
Ne pas raccorder en té un drain à serpentin d'évaporateur et un drain de condensats de la chaudière.
17 Feet (5M)
MAX
Drain Line Línea de Drenaje Conduit de Vidange
Discharge Line
Línea de Desagüe
Conduit de refoulement
Main Drain from Coil
Drenaje principal desde el serpentín
Drain principal du serpentin
¾” (1.9cm)
ALAMBRADO
CÂBLAGE
This pump is supplied with a 3-prong grounding type attachment plug.
To reduce the risk of electric shock connect only to a properly grounded receptacle.
¡ADVERTENCIA!
Esta bomba se provee de una enchufe de tres dientes del accesorio del tipo que pone a tierra.
Para reducir el riesgo de la descarga eléctrica conecte solamente con un · correctamente puesto a tierra del receptáculo.
MISE EN GARDE
Cette pompe est fournie avec une prise fondante à trois dents d'attachement de type.
Pour réduire le risque de décharge électrique reliez seulement à un réceptacle correctement fondé.
: Turn off electrical power at the fuse box before making any line voltage connections. The wiring must comply with local codes. Use the National Electrical Code if local code is nonexistent. LINE VOLTAGE: If it is necessary to install a receptacle in the furnace/air conditioner area, connect only to a constant source of the nameplate voltage. (Example: The black and white leads in the furnace junction or switch box bringing 120 volt power to the furnace). Be sure that you do not connect into a fan or limit control circuit. LOW VOLTAGE: Connect the high-level safety switch leads to the thermostat control circuit of the furnace/air conditioner.
¡ADVERTENCIA! Apague la energía eléctrica en el tablero de fusibles antes de hacer cualquier conexión con el voltaje de la línea. Todo el alambrado debe estar en conformidad con los códigos locales. Si no existe un código local, use el Código Eléctrico Nacional. VOLTAJE DE LA LÍNEA: Si es necesario instalar un receptáculo en el área de la caldera/del aire acondicionado, conecte únicamente a una fuente constante del voltaje que indica la placa. (Ejemplo: Los conectores negros y blancos del empalme de la caldera o de la caja de interruptores que transportan una potencia de 120 voltios a la caldera). Asegúrese de no conectarlo en un ventilador ni en un circuito de controles limitadores. BAJO VOLTAJE: Conecte los cables del interruptor de seguridad de alto nivel al circuito de control del termostato de la caldera/el aire acondicionado.
MISE EN GARDE : Couper l’alimentation au niveau de la boîte à fusibles avant d’effectuer les raccordements de tension sectorielle. Tout câblage doit respecter la réglementation locale. En cas de silence, s’en reporter au Code électrique national des États-Unis. TENSION DE LIGNE : S'il faut installer une prise dans la région de la chaudière/climatiseur, connecter cette prise seulement à une source constante de tension selon la plaque signalétique. (Exemple : les fils noirs et blancs de la boîte de jonction ou de la boîte de commutateurs de la chaudière acheminant 120 volts de courant à la chaudière). S'assurer de ne pas connecter dans un ventilateur ou circuit limiteur. BASSE TENSION : Connecter le fil du commutateur de sécurité de haut niveau au circuit de commande du thermostat de la chaudière/climatiseur.
Yellow / Amarillo / Jaune
Red / Rojo / Rouge
To Safety Switch
Al Interruptor De Seguridad
À la Commande De Sécurité
Yellow / Amarillo / Jaune
Red / Rojo / Rouge
Green / Verde / Vert
Relé / Transformador o Tablero de Terminales de Bajo Voltaje
Relais / Transformateur ou Bornier Basse Tension
Loading...
+ 2 hidden pages