Badger Meter M2000 User Manual

Part Number Construction
MAG-OG-0942-EN-01 (February 2019)
M1 - - - - - -
M1000 Meter Type
Amplifier
HARD RUBBER
150# flanges
PTFE
150# flanges
PFA
150# flanges
Meter Type- Standard LL R1
P1 PA
1/4" 002
5/16" 003
3/8" 004
1/2" 005
3/4" 007
1" 010
1-1/4" 012
1-1/2" 015
2" 020
2-1/2" 025
4" 040
5" 050
6" 060
8" 080
10" 100
Electrodes & Grounding
Alloy C with 316 Stainless Steel Grounding Rings
A
Amplifier Type
110/220V AC; Meter Mounted M
110/220V AC; Remote Mounted R
110/220V AC; Remote Mounted; Submersible S
24V DC; Meter Mounted E
24V DC; Remote Mounted F
24V DC; Remote Mounted; Submersible G
Remote Cable Length
None WW
5 ft.; Standard Ca ble AA
10 ft.; Standa rd Cable AB
15 ft.; Standa rd Cable AC
30 ft.; Standa rd Cable AF
50 ft.; Standa rd Cable AK
75 ft.; Standa rd Cable AR
100 ft.; Standard Cable BW
125 ft.; Standard Cable BE
150 ft.; Standard Cable BK
Communications/ Outputs
Standard Output S
Wiring Method
None XX
Itron - 5 ft. (MTR, A SSY)
CF
Itron - 25 ft. (MTR , ASSY)
CJ
Unit of Measure Totalizer / Flow Rate
Gallons/gallons per minute G
Gallons/cubic feet per minute B
Gallons/cubic meters per second D
Cubic Meters/gallons per minute C
Cubic Meters/cubic meters per minute T
Cubic Meters/cubic meters per hour H
Cubic Feet/gallons per minute F
Cubic Feet/cubic feet per minute J
Cubic Feet/cubic meters per hour K
Liters/gallons per minute L
Liters/liters per second N
Liters/liters per minute P
Liters/liters per hour Q
Million Gallons/gallons per minute
M
Gallons/millions gallons per day R
Acre Feet/gallons per minute A
Second-Foot Day/cu bic feet per second S
Testing & Tagging
Factory Calibrated F
3rd Party Calibrat ed 3
Factory Calibrated/Stainless Steel Tag S
3rd Party Calibrated w/ Stainless Steel Tag T
State of Kansas Certified K

M1000 for general purpose detection in rugged environments

Detector
Electrodes &
Remote Cable
Length
Communications/
Outputs
Wiring
Method
Unit of Measure
Totalizer/Flow Rate
Testing &
Tagging
C-Steel
3"
030
C-Steel
Stainless Steel
Twist Tight - 5 ft. (MTR, ASSY) Twist Tight - 10 ft. (MTR, ASSY) Twist Tight - 25 ft. (MTR, ASSY) Twist Tight - 75 ft. (MTR, ASSY) Nicor - 6 ft. (MTR, AS SY) Nicor - 25 ft. (MTR, A SSY)
Cubic Meters/cubic meters per second E
TF TH TJ TK
NG
NJ
Page 2
M2 - - - - - -
HARD RUBBER
150# flanges
HARD RUBBER
300# flanges
HARD RUBBER
150# flanges
Meter Type- Standard LL
R1 R2 R4
1/4"
002
5/16"
003
3/8"
004
1/2"
005
3/4"
0071"010
1-1/4"
012
1-1/2"
0152"020
2-1/2"
0253"030
4"
0405"0506"060
8"
080
10"
100
12"
120
14"
140
16"
160
18"
180
20"
200
22"
220
24"
240
28"
280
30"
300
32"
320
36"
360
40"
400
42"
48"
480
54"
540
Electrodes & Grounding
Alloy C with 316 Stainless Steel Grounding Rings
A
Stainless Steel with 316 Stainless Steel Grounding Rings
S
Platinum Plated with 316 Stainless Steel Grounding Rings
P
Tantalum with 316 Stainless Steel Grounding Rings
T
Platinum/Rhodium with 316 Stainless Steel Grounding Rings
R
Alloy C Electro de and Grounding Elect rode C
Stainless Steel Electrode and Grounding Electrode D
Platinum Plated Electrode and Grou nding Electrode G
Tantalum Electrode and Grou nding Electrode L
Platinum/Rhodium Electrode and Gr ounding Electrode H
Amplifier Type
110/220V AC; Meter Mou nted M
110/220V AC; Remote Mou nted R
110/220V AC; Remote Mou nted; Submersible S
24V DC; Meter Mounted E
24V DC; Remote Mounted F
24V DC; Remote Mounted; Submersible G
Remote Cable Length
NoneWW5 ft. Standard Cable
AA
10 ft. Standard Cable
AB
15 ft. Standard Cable
AC
30 ft. Standard Cable
AF
50 ft. Standard Cable
AK
75 ft. Standard Cable AR
100 ft. Standard Cable
BW
125 ft. Standard Cable
BE
150 ft. Standard Cable
BK
175 ft. Standard Cable
BR
200 ft. Standard Cable DW
225 ft. Standard Cable DE
250 ft. Standard Cable DK
275 ft. Standard Cable DR
300 ft. Standard Cable EW
325 ft. Standard Cable EE
350 ft. Standard Cable EK
375 ft. Standard Cable ER
400 ft. Standard Cable FW
425 ft. Standard Cable FE
450 ft. Standard Cable FK
475 ft. Standard Cable FR
500 ft. Standard Cable GW
Communication/Outputs
Standard Output
S
Standard Output with HART H
Standard Output with PROFIBUS DP P
Standard Output with MODBUS 485 RTU M
Wiring Method
None
XX
Itron - 25 ft. (M TR, ASSY)
CJ
Unit of Measure Totalizer/ Flow Rate
Gallons/gallons per m inute G
Gallons/cubic feet per minute B
Gallons/cubic meters per second D
Cubic Meters/gallons per minute C
Cubic Meters/cubic meters per second E
Cubic Meters/cubic meters per minute T
Cubic Meters/cubic meters per hour H
Cubic Feet/gallons per minute F
Cubic Feet/cubic feet per minute J
Cubic Feet/cubic meters per hour
K
Liters/gallons per minute L
Liters/liters per second N
Liters/liters per minute P
Liters/liters per hour Q
Million Gallons/gallon s per minute M
Gallons/millions gallon s per day R
Acre Feet/gallons per minute A
Second-Foot Day/cubic feet per second S
Testing & Tagging
Factory Calibrated F
3rd Party Calibrated 3
Factory Calibrated/St ainless Steel Tag S
3rd Party Calibrated w/ Stainless S teel Tag T
State of Kansas Cer tified K
M2000 for general purpose detection - Hard Rubber Liner
Meter Type
M2000
C-Steel
420
Detector
C-Steel
Stainless Steel
Electrodes &
Grounding
Amplifier
Remote Cable
Length
Communications/
Outputs
Wiring
Method
Unit of Measure
Totalizer/ Flow Rate
Testing &
Tagging
Twist Tight - 5 ft. (MT R, ASSY) TF Twist Tight - 10 ft. (MT R, ASSY) TH Twist Tight - 25 ft. (MT R, ASSY) TJ Twist Tight - 75 ft. (MT R, ASSY) TK Nicor - 6 ft. (MTR, A SSY) NG Nicor - 25 ft. (MT R, ASSY) NJ Itron - 5 ft. (MTR, ASSY) CF
Page 3
M2 - - - - - -
Type
grounding
Amplifier
Length
Outputs
Method
Totalizer/ Flow Rate
Testing and
Tagging
PTFE
PTFE
PTFE
PFA Stainless
Meter Type- Standard LL
P1 P2 P4
PA
1/4"
002
5/16"
003
3/8"
004
1/2"
005
3/4"
0071"010
1-1/4"
012
1-1/2"
015
2"
020
2-1/2"
025
3"
030
4"
0405"050
6"
060
8"
080
10"
100
12"
120
14"
140
16"
160
18"
180
20"
200
22"
220
24"
240
28"
280
30"
300
32"
320
36"
360
40"
400
42"
48"
480
54"
540
Electrodes & Grounding
Alloy C with 316 Stainless Steel Grounding Rings
A
Stainless Steel with 316 Stainless Steel Grounding Rings
S
Platinum Plated with 316 Stainless Steel Grounding Rings P
Tantalum with 316 Stainless Steel Grounding Rings
T
Platinum/Rhodium with 316 Stainless Steel Grounding Rings
R
Alloy C Electro de and Grounding Elect rode C
Stainless Steel Electrode and Grounding Electrode D
Platinum Plated Electrode and Grou nding Electrode G
Tantalum Electrode and Grou nding Electrode L
Platinum/Rhodium Electrode and Gr ounding Electrode H
Amplifier Type
110/220V AC; Meter Mou nted M
110/220V AC; Remote Mou nted R
110/220V AC; Remote Mou nted; Submersible S
24V DC; Meter Mounted E
24V DC; Remote Mounted F
24V DC; Remote Mounted; Submersible G
Remote Cable Length
NoneWW5 ft. Standard Cable
AA
10 ft. Standard Cable
AB
15 ft. Standard Cable
AC
30 ft. Standard Cable
AF
50 ft. Standard Cable
AK
75 ft. Standard Cable AR
100 ft. Standard Cable
BW
125 ft. Standard Cable
BE
150 ft. Standard Cable
BK
175 ft. Standard Cable
BR
200 ft. Standard Cable DW
225 ft. Standard Cable DE
250 ft. Standard Cable DK
275 ft. Standard Cable DR
300 ft. Standard Cable EW
325 ft. Standard Cable EE
350 ft. Standard Cable EK
375 ft. Standard Cable ER
400 ft. Standard Cable FW
425 ft. Standard Cable FE
450 ft. Standard Cable FK
475 ft. Standard Cable FR
500 ft. Standard Cable GW
Communications/Outputs
Standard Output
S
Standard Output with HART H
Standard Output with PROFIBUS DP P
Standard Output with MODBUS 485 RTU M
Wiring Method
None
XX
Itron - 5 ft. (MTR, ASSY)
CF
Itron - 25 ft. (M TR, ASSY)
CJ
Unit of Measure Totalizer/ Flow Rate
Gallons/gallons per m inute G
Gallons/cubic feet per minute B
Gallons/cubic meters per second D
Cubic Meters/gallons per minute C
Cubic Meters/cubic meters per second E
Cubic Meters/cubic meters per minute T
Cubic Meters/cubic meters per hour H
Cubic Feet/gallons per minute
F
Cubic Feet/cubic feet per minute J
Cubic Feet/cubic meters per hour
K
Liters/gallons per minute L
Liters/liters per second N
Liters/liters per minute P
Liters/liters per hour Q
Million Gallons/gallon s per minute M
Gallons/millions gallon s per day R
Acre Feet/gallons per minute A
Second-Foot Day/cubic feet per second S
Testing & Tagging
Factory Calibrated F
3rd Party Calibrated 3
Factory Calibrated/St ainless Steel Tag S
3rd Party Calibrated w/ Stainless S teel Tag T
State of Kansas Cer tified K
M2000 for general purpose detection- PTFE Liner
Meter
M2000
C-Steel
150# flanges
420
C-Steel
300# flanges
Detector
Stainless Steel
150# flanges
Steel 150#
Flanges
Electrodes &
Remote Cable
Communications/
Wiring
Unit of Measure
Twist Tight - 5 ft. (MT R, ASSY) TF Twist Tight - 10 ft. (MT R, ASSY) TH Twist Tight - 25 ft. (MT R, ASSY) TJ Twist Tight - 75 ft. (MT R, ASSY) TK Nicor - 6 ft. (MTR, A SSY) NG Nicor - 25 ft. (MT R, ASSY) NJ
Page 4
Loading...